NICE Toona TO6024HS – fast 24 V swing gate operator
NEW| Product availability: | within 7 days | We usually dispatch goods within 7 days. |
|---|
within 7 days
€645.68 including VAT
| Weight |
|---|
| 12 kg |
Description of NICE Toona TO6024HS – fast 24 V swing gate operator
NICE Toona TO6024HS is a fast standalone operator for one gate leaf, with a 24 V DC and a magnetic encoder. The maximum values 6 m and 1,450 kg must be assessed using the combined load curve.
NICE specifies an opening time of approximately 30 seconds with standard installation, excluding acceleration and deceleration. The actual time depends on the geometry, gate leaf and control unit settings. The operator is sold separately; choose the accessories and control unit separately.
| Quick navigation | |
|---|---|
| Package contents | Accessories |
| Kits | Limits |
| Service life | Installation |
| Wiring | Stops |
| Testing | Manual release |
| Specifications | Maintenance |
| Manual | |
| Accessories – terminals and polarity | PDF manual |
What's included with the operator
In the lower part of the original image labelled Toona 6–7 are the motor, front bracket, rear bracket with plate, mounting hardware and keys for manual release. The exact number of small parts depends on the version of the package supplied; the control unit and safety accessories are selected separately.
Wiring accessories to the MC824HR30 control unit
The following terminals belong to the MC824HR30/MCA1R30 control unit in an assembly with the TO6024HS motor, not to the motor itself. Disconnect the mains and backup battery before working. If using a different board, follow its own wiring diagram.
| Accessories | Terminals, voltage and polarity |
|---|---|
| BlueBUS photocells | Connect compatible photocells, such as EPMB, using two wires, to BlueBUS. + and − are not polarity-sensitive. Set the address and repeat the learning procedure after changing devices. |
| STOP and command inputs | The STOP input accepts a volt-free NO or NC contact, or a resistor device 8.2 kΩ; its status is learned. SbS, Open and Close inputs accept a volt-free NO contact on the corresponding terminal pair. Contacts have no +/− polarity; do not apply an external voltage to the input. |
| Auxiliary power supply | Right terminal of the STOP pair = −; left terminal of the SbS pair = +, as viewed in the image below (labels above the terminals). Power supply for a compatible reader or module: 24 V DC (−30% to +50%), 200 mA maximum, including in Stand-by mode. Wire the module's command relay separately as a volt-free contact; check the permitted voltage range and current draw of the module. |
| Flashing light, lock, indicator | FLASH: 12 V DC, 21 W maximum; ELS: 12 V AC, 15 VA maximum, with no fixed +/− polarity; OGI: 24 V DC, 4 W maximum. For FLASH/OGI, the diagram does not specify the +/− order on the terminal pair, so do not guess; for a polarised product, check the markings on both the board and the product. Outputs may have different functions depending on the programming. |
| Radio receiver and backup power | The plug-in receiver fits into the SM, and the backup battery connects to its dedicated connector, depending on the board installed. They do not connect to BlueBUS or to the motor terminals. |
For detailed terminal locations, the learning procedure and testing of safety devices, see the MC824HR30 control unit's own manual.
Control unit and accessories
The standalone motor requires a compatible control unit. The current MC824HR30/MCA1R30 controls one or two 24 V motors and has its own manual; for the older MC824HR10/MCA1R10, use the manual for its board. Check the contents of the selected kit for the exact configuration.
| What | Why | Type |
|---|---|---|
| Control unit | Controls a 24 V motor; select the manual for the board actually installed. | |
| Receiver | Choose the radio receiver to match the transmitter's coding and the board. | |
| Transmitter | Choose one compatible with the receiver; BD and LR modes require the corresponding receiver. |
|
| Photocells | Selection based on the BlueBUS inputs, power supply, and features of the specific control unit. | |
| Flashing light | The voltage, power consumption, and flashing mode must match the control unit output. |
Kits with the TO6024HS operator
Separate kits are available for both single- and double-leaf gates. Before ordering, check the specific product page for the actual kit contents and control board.
| Single-leaf gate | Double-leaf gate |
|---|---|
| Kit with accessories Kit with photocells Basic kit | Basic kit Kit with accessories Kit with photocells |
Operating range for one leaf
Length and weight are interdependent limits. Curve TO6024HS handles approximately 1,450 kg at 3 m and approximately 700 kg at 6 m. Use only the curve for your model and take account of movement resistance, solid infill, and wind; the maximum figures cannot automatically be combined.
Service life based on load
For one leaf, add the relevant weight, length, and environmental indices. Then compare the total with the NICE chart. The chart does not show values above 100%. This is an indicative service-life estimate of 80,000 to 250,000 operating cycles, depending on the load, not a guarantee.
| Automation system characteristics | Index | Service-life chart |
|---|---|---|
| Weight up to 400 kg | 0% | |
| Over 400 up to 500 kg | 10% | |
| Over 500 kg | 20% | |
| Length 2–3 m | 0% | |
| Length 3–4 m | 0% | |
| Length over 4 up to 5 m | 10% | |
| Length over 5 up to 6 m | 20% | |
| Temperature above 40 °C, below 0 °C, or humidity above 80% | 20% | |
| Solid leaf infill | 15% | |
| Windy area | 15% |
| NICE chart |
|---|
Installing the operator and brackets
Before installation, check that the gate is sturdy, the leaf moves smoothly by hand, there is room for manual release, and there is a suitable mounting point on the rigid part of the leaf.
Rear bracket mounting and the A/B/C chart
Post and brackets: As a general guide, we recommend a sturdy steel post 120 × 120 mm. For 100 × 100 mm assess the wall thickness, anchoring, foundation, hinge offset, and wind load separately. The cross-section alone does not guarantee strength.
Measure the hinge offset C. On the original TO6024HS/TO7024 chart, draw a horizontal line from C and read off B; the intersection with the recommended line r.i.l. determines the angle and A vertically. Dimensions A and B should be similar. B values below line t are not recommended by NICE.
If the post profile or hinge position makes it impossible to follow the chart, the rear bracket must be modified or a suitable extended mounting bracket for Toona 6–7. An extended rear bracket is required when opening outwards. Choose the dimensions to suit the actual gate and check the full range of movement before making the final weld.
After checking the geometry, securely fasten the rear bracket to the mounting plate and post. Choose the post fasteners to suit the substrate. Fasten the front bracket to the rigid part of the leaf; the motor must have the required small amount of play at the pins to prevent it from binding.
Dimension D = 1,070 mm. After determining A from the chart, read off E in the NICE table; the height difference between the front and rear brackets is F = 50 mm.
| A (mm) | E (mm) |
|---|---|
| 180 | 890 |
| 190 | 880 |
| 200 | 870 |
| 210 | 860 |
| 220 | 850 |
| 230 | 840 |
| 240 | 830 |
| 250 | 820 |
| 260 | 810 |
| 270 | 800 |
| 280 | 790 |
For the rear pin, NICE specifies tightening the nut and then loosening it by 1/10 of a turn, so that minimal clearance remains between the parts. Tighten the front mounting according to the manufacturer's drawing.
Motor wiring and connection
Before opening the cover and connecting the wires, disconnect the power supply. The drive has separate terminals for the encoder and 24 V DC motor; do not mix them up. Connect the wires and protective earth according to the original NICE diagram and the instructions for the control unit actually installed. The 24 V marking refers to the motor voltage, not automatically to the control unit's mains supply.
When opening outward, NICE specifies reversing the motor supply polarity. At the same time, the mounting geometrymust be designed correctly; changing the wires alone is not enough. Then check the direction of travel, stop positions and safety devices according to the instructions for the installed control board.
Internal opening and closing stops
On the Toona 6–7 series, the mechanical stops are adjusted for both opening and closing.. Disengage the motor, move the gate leaf so that the stop screw is accessible, loosen it, manually set the required open position, move the stop up to the pin and tighten it. Repeat the same procedure in the required closed position, then re-engage the motor. Check the final positions and the safety of the entire gate during testing.
Test before first use
After installation and stop adjustment, test the entire gate, not just the motor startup. With the drive disengaged, NICE specifies manually moving the gate leaf with a force of no more than 390 N.
- Check that the gate moves smoothly by hand throughout its full range, that the brackets are secure and that manual release works safely.
- Send repeated open, stop and close commands; check the direction, run-on, stops and, for two-leaf gates, the sequence according to the control unit instructions.
- Test the photocells, safety edges and any other installed protective devices individually. Measure the operating forces in accordance with applicable requirements; the gate may be used only after passing the test.
Manual drive release
Engage or disengage the drive only when the gate leaf is stationary. If an electric lock is installed, unlock it first. In the event of a fault, disconnect the power supply.
- Slide open the release lock cover.
- Insert the supplied key and turn it clockwise.
- Raise the lever and move the gate leaf by hand. To re-engage the drive, lower the lever, turn the key back, remove it and close the cover.
Inspection and maintenance
Carry out maintenance at least every 6 months. After disconnecting the power supply, check the mounting, corrosion, wear, bolted joints and lubrication of the screw and nut. After switching the power back on, test the movement, manual release and all safety devices.
Technical specifications
| Parameter | Value |
|---|---|
| Model | TO6024HS |
| Motor voltage | 24 V DC |
| Maximum / rated current | 5 A / 2.5 A |
| Maximum / rated power input | 120 W / 60 W |
| Stroke | 584 mm |
| No-load speed | 0.016 m/s |
| Maximum / rated force | 2,200 N / 1,200 N |
| Cycles per hour at rated force | 41 |
| Protection rating | IP44 |
| Operating temperature | −20 to +50 °C |
| Insulation class | F |
| Estimated service life | 80,000 to 250,000 cycles, depending on load |
| Dimensions L × W × H | 1,200 × 128 × 150 mm |
| Motor weight | 15 kg |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]