NICE Toona TO5024HS – fast standalone 24 V swing gate operator
NEW| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€383.78 including VAT
| Weight |
|---|
| 9,55 kg |
Description of NICE Toona TO5024HS – fast standalone 24 V swing gate operator
NICE Toona TO5024HS is a fast standalone 24 V DC motor for one gate leaf. The figures of up to 5 m and up to 400 kg are separate maximum values; determine the permitted combination from the TO5024HS curve.
NICE specifies an opening time of approximately 16 seconds for a 90° opening with standard installation, excluding acceleration and deceleration. The actual time depends on the geometry, gate leaf and control unit settings. 24 V is the motorvoltage; for the current MC824HR30/MCA1R30 follow the manual for this board.
| Quick navigation | |
|---|---|
| Package contents | Limits |
| Service life | Installation |
| Wiring | Stop |
| Accessories | Control unit |
| Release | Specifications |
| Maintenance | PDF manual |
| Accessories – terminals and polarity | |
- Fast HS version: 0.025 m/s unloaded; 0.018 m/s under load.
- One gate leaf, up to 5 m and 400 kg, only in a combination permitted by the TO5024HS graph.
- Internal opening stop, manual release and separate encoder wires.
What is included with the standalone operator
| NICE-specified component | Purpose |
|---|---|
| TO5024HS operator | Drives one gate leaf. |
| Front and rear brackets with mounting plate | Fixing to the gate leaf and post. |
| Fasteners and release keys | Mounting the operator on the brackets and manual operation in the event of a power failure. |
The exact number of parts depends on the supplied version; check the package contents against Figure 1 in the NICE manual. Anchor bolts and plugs for fixing to the post or wall are supplied separately according to the substrate. Choose the control unit and safety accessories to suit the specific setup.
Operating range
TO5024HS: the 400 kg limit applies approximately to a gate leaf up to 2 m; at 5 m, the graph shows approximately 190 kg. Also assess resistance to movement, the gate leaf infill and wind exposure. The graph shows the operating limit; it is not a service-life guarantee.
Service life according to load
For each gate leaf, add the relevant indices for weight, length and environmental conditions. Read the approximate number of cycles from the original graph. This is the manufacturer's estimate, not a service-life guarantee.
| Characteristics of the complete automation system | Index | Service-life graph |
|---|---|---|
Weight up to 300 kg | 0% | |
Over 300 kg and up to 400 kg | 10% | |
Length 2–3 m | 0% | |
Length over 3 m and up to 4 m | 10% | |
Length over 4 m and up to 5 m | 20% | |
Temperature above 40 °C, below 0 °C, or humidity above 80% | 20% | |
Solid gate leaf infill | 15% | |
Wind-exposed area | 15% |
| NICE graph |
|---|
Choosing the control unit
Current model: MC824HR30/MCA1R30. For an older setup, check the board identification; the manual for the new board does not automatically apply to the older one. The motor is also sold separately, so check the contents of the specific kit.
If you are unsure which board or mounting geometry to choose, contact technical support.
I. Installing the rear mounting bracket
Bracket fixing: For a typical steel structure, a 120 × 120 mm post is recommended as a general guideline. A 100 × 100 mm profile may be used after assessing the material, wall thickness, height, foundation, anchoring and wind load. The post dimensions alone do not confirm that the installation is strong enough.
Measure the hinge offset C, then use the original installation graph to determine B, the opening angle and A. A and B should be similar; values of B below the line t are not recommended by NICE. If the post or hinge offset does not allow the geometry to be maintained, adjust the bracket or use the extended PLA6 rear bracket. An extended rear bracket is required for outward opening; determine the dimensions based on the actual gate. Before welding, measure the supplied brackets and check the gate leaf's full range of movement.
Before installation, check that the gate leaf is sturdy, moves smoothly by hand and provides access to the operator release.
- Measure hinge offset C according to the gate drawing.
- On the graph, draw a horizontal line from C and read off B.
- The intersection with the recommended r.i.l. line indicates the permissible angle; read off A on the vertical axis.
- Before welding the bracket, check A, B and the gate leaf’s full range of movement. NICE does not recommend B values below the t line.
The supplied rear bracket for the Toona 4–5 series is 150 mm long. If its length needs adjusting, test the geometry, then shorten it and securely join it to the mounting plate according to the NICE drawing.
II. Installing the front mounting bracket
Position the front bracket according to the fixed dimension D = 880 mm and the E table for the selected A value. The original NICE drawing for Toona 4–5 specifies a height difference of F = 34 mm. Before final fastening, measure the brackets actually supplied and check that the gate leaf moves freely.
| A (mm) | E (mm) |
|---|---|
| 100 | 780 |
| 110 | 770 |
| 120 | 760 |
| 130 | 750 |
| 140 | 740 |
| 150 | 730 |
| 160 | 720 |
| 170 | 710 |
| 180 | 700 |
| 190 | 690 |
| 200 | 680 |
| 210 | 670 |
| 220 | 660 |
| 230 | 650 |
| 240 | 640 |
| 250 | 630 |
| 260 | 620 |
| 270 | 610 |
| 280 | 600 |
Fasten the rear bracket to the fixed post and the front bracket to the solid part of the gate leaf. Before final welding, check the gate leaf’s full range of movement and ensure the drive moves freely.
III. Mounting the drive on the rear bracket
- Attach the motor to the rear bracket using the supplied pin or a bolt, washer and nut, as shown in the NICE drawing.
- Tighten the nut, then loosen it by approximately 1/10 of a turn to leave minimal clearance for movement at the joint.
IV. Mounting the drive on the front bracket
Temporarily attach the front bracket to the solid part of the gate leaf, check its full range of movement, and only then complete the fastening. Connect the motor to the bracket using the supplied pin and washer, as shown in the NICE drawing.
V. Setting the mechanical opening stop
The TO5024HS has an internal opening stop. When setting it, observe the range shown in the NICE drawing as 100 mm max. Set the closed position and determine whether external stops are needed based on the specific gate.
- Release the drive according to the manual release procedure.
- Loosen the opening-stop screw and move the gate leaf by hand to the required open position.
- Move the stop up against the pin and tighten the screw as shown in the drawing.
- Close the gate leaf by hand and re-engage the drive.
Motor wiring and connections
Disconnect the power supply before wiring. 24 V DC is the motor voltage; the control unit’s power supply and accessory outputs must be considered separately. The motor has a separate pair of motor wires and a pair of encoder wires. For the 4–5 series drive, the terminals are labelled as shown in the illustration; for the 6–7 series, use its separate illustration. Determine the connections on the control board solely from the actual board in the assembly. For a gate that opens outward, NICE specifies reversing the motor supply polarity; do not connect the encoder as the motor power supply.
After wiring, check the direction of movement, stopping positions and safety devices according to the manual for the specific control unit.
Checks before first operation
Before switching on, release the gate leaf and make sure it moves smoothly through its full travel without catching, and that the brackets and post remain secure.
- After wiring according to the actual control unit, check the direction of movement and set the positions as instructed in its manual. Force settings are configured in the control unit, not in the motor itself.
- Test the opening stop, safety photocells, any safety edges, the STOP control and the manual release. Check that operating forces are safe; if there is a pedestrian gate in the leaf, also check that the drive is disabled when it is open.
- Give the customer the release procedure and the manual for the control unit actually installed.
Connecting accessories to the MC824HR30
The following terminals are for the MC824HR30/MCA1R30 control unit in an assembly with a TO5024HS motor, not for the motor itself. Disconnect the mains power and backup battery before working. For a different board, use its own wiring diagram.
| Accessory | Terminals, voltage and polarity |
|---|---|
| BlueBUS photocells | Connect compatible photocells, such as EPMB, using two wires to BlueBUS. There is no distinction between + and −. Set the address and repeat the learning procedure after changing devices. |
| STOP and commands | Input STOP accepts a voltage-free NO or NC contact, or a resistive element 8.2 kΩ; its state is learned. SbS, Open and Close accept a voltage-free NO contact on the corresponding pair of terminals. The contacts have no +/− polarity; do not apply an external voltage to the input. |
| Auxiliary power supply | Right terminal of the STOP pair = −, left terminal of the SbS pair = +, when viewed in the orientation shown in the image below (labels above the terminals). Power supply for a compatible reader or module: 24 V DC (−30% to +50%), 200 mA maximum, including in Stand-by mode. Wire the module's command relay separately as a voltage-free contact; check the module's permitted voltage range and current draw. |
| Flashing light, lock, indicator light | FLASH: 12 V DC, 21 W maximum; ELS: 12 V AC, 15 VA maximum, no fixed +/− polarity; OGI: 24 V DC, 4 W maximum. For FLASH/OGI, the diagram does not specify the +/− order on the pair of terminals, so do not guess it; for a polarity-sensitive product, check the markings on both the board and the product. The function of the outputs may change depending on the programming. |
| Radio and backup power | The plug-in receiver fits into the SM, and the backup battery goes into its own connector, depending on the board installed. They do not connect to BlueBUS or to the motor terminals. |
For detailed terminal locations, learning procedures and safety device testing, see the the MC824HR30 control unit's own manual.
Accessories by control unit
Choose accessories based on the interface of the control unit and receiver actually installed. Wireless and command devices may require additional equipment or configuration.
| What | Why | Type |
|---|---|---|
| Control unit | Controls a 24 V motor; follow the procedures for the board actually installed. | |
| Receiver | Choose a radio receiver to match the transmitter's coding. | |
| Transmitter | Choose one to match the receiver: two-way BD and LR modes require a compatible receiver. |
|
| Photocells | Use depends on the BlueBUS interface and, for wireless types, on additional equipment. | |
| Flashing light | The voltage and power consumption must match the output of the control unit actually installed. |
Manual drive release
Release or re-engage the drive only when the gate leaf is stationary. If the gate has an electric lock, unlock it first. In the event of a fault, disconnect the power supply.
- Slide the protective cover aside, insert the supplied key and turn it clockwise.
- Lift the release lever and move the gate leaf manually.
- To re-engage the drive, lower the lever, turn the key anticlockwise, remove it and close the cover.
Before restarting, check that the drive is engaged and that no one is in the gate's path.
Inspection and maintenance
Service the unit at least every 6 months. After disconnecting the power supply, check the mounting, wear, corrosion and lubrication of the screw and nut. After switching on, test the movement, release mechanism and safety devices.
Technical specifications
Specification 75 cycles/hour applies according to NICE at the rated force. The speed of 0.025 m/s is unloaded; under load, the manufacturer specifies 0.018 m/s.
| Parameter | Value |
|---|---|
Model | TO5024HS |
Drive motor | 24 V DC |
Maximum / rated current draw | 5 A / 2.5 A |
Maximum / rated power consumption | 120 W / 60 W |
Stroke | 505 mm |
Unloaded speed | 0.025 m/s |
Speed under load | 0.018 m/s |
Maximum / rated force | 1,800 N / 600 N |
Cycles per hour at rated force | 75 |
Protection rating | IP44 |
Operating temperature | −20 to +50 °C |
Insulation class | F |
Estimated service life according to NICE | 80,000 to 250,000 operating cycles |
Dimensions L × W × H | 965 × 115 × 105 mm |
Motor weight | 7.5 kg |
The motor weight shown in the table is NICE's figure excluding packaging. The weight for the selected variant includes packaging and is used to calculate shipping costs.
Slovak-Czech NICE Toona installation manual. For programming, position learning and radio setup, refer to the manual for the control unit actually installed.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]