Description of NICE TOO TOO4524 – standalone operator for one gate leaf, 4.5 m/250 kg, intensive use
NICE TOO4524 is a standalone electromechanical operator for one gate leaf swing gate up to 4.5 m and up to 250 kg. The motor has 24 V DC and is non-reversible. In the event of a power failure, is released with a key. It is suitable for residential and light industrial use; control unit and safety devices are selected for the gate as a whole.
When to choose this operator
The 4.5 m and 250 kg figures are the maximums for a single gate leaf. The suitability of a particular gate also depends on its operating resistance, hinge position, wind exposure, leaf infill and bracket geometry. Check suitability against the gate's actual dimensions and weight, and ensure it moves freely.
The 24 V motor is also suitable for more intensive use. Assess the permitted opening frequency and the load on the complete automation system based on the gate leaf, installation and control unit.
Control unit and gate equipment
| Generation | Compatible control unit |
|---|---|
| Current | MC424LR30 / MCA2R30 for one or two TOO 24 V motors. |
| Older, still available | MC424LR10 / MCA2R10. Use the manual for this generation. |
Check the markings on the installed control board and use the manual for that generation. For the older MC424LR01, do not use procedures for the R10 or R30. Instructions for selecting the motor type, learning the travel limits and programming the current control unit are in the MC424LR30 manual.
The 24 V marking refers to the motor. Controller MC424LR30 connects to a 230 V AC mains supply and provides the relevant motor and auxiliary outputs; the wiring must comply with the exact manual for this unit.
The motor is shown with front and rear brackets, connecting hardware and release key. Check the package contents before installation. Control unit, photocells and anchoring to the specific post are selected separately or according to the kit contents.
Kits for one or two gate leaves
The standalone motor is designed for one gate leaf. A double-leaf gate requires two operators. Our 24 V kits below include MC424LR10 and differ in the additional equipment included. The standalone 230 V alternative motor is shown in the centre.
| Kits for 1 gate leaf | Kits for 2 gate leaves |
|---|---|
NICE TOO4524 kit for 1 gate leaf MC424LR10 and 1 remote control INTI2. Basic With photocells With accessories | NICE TOO4524 kit for 2 leaves MC424LR10 and 1 remote control INTI2. Basic With photocells With accessories |
Limits 4.5 m and 250 kg are assessed separately for each leaf. With two leaves, the limit for an individual motor does not increase. Add the required items to the basic kit safety devices according to the specific gate.
Mounting the brackets and positioning the operator
First determine the hinge and rear bracket positions, then check clearance throughout the gate's full range of movement. Dimensions A and B determine the achievable opening angle and force profile. The brackets must be securely fixed to a suitably engineered structure; the post dimensions alone are not enough to assess the anchoring. Before permanently fixing the brackets, check that the gate moves freely by hand without binding.
TOO4524 mounting dimensions
| Opening angle | A [mm] | B [mm] |
|---|---|---|
| 90° | 200 | 250 |
| 110° | 170 | 170 |
For the specific post and bracket, see TOO4524 anchoring bracket dimensions. For an unusual hinge position or outward opening, design a suitable mounting arrangement that preserves dimensions A, B and C and keeps the motor and brackets clear of the leaf's movement.
Dimension C with the gate closed
With the leaf closed, measure the distance C < 1 300 mm. The value must be less than the stated limit; it must not equal or exceed it. Keep the selected A/B combination as well.
Mounting and checking the movement
- Select one A/B combination for the specific operator and opening angle. Fix the rear bracket to a sturdy post or suitably engineered support structure, then attach the operator to it.
- Operator release it with the key, fully extend the piston as shown in the NICE drawing, then temporarily position the front bracket against the rigid gate frame.
- Level the motor and connect the piston to the front bracket. Check dimension C when closed, and check that the leaf moves freely throughout its full travel.
- Check that the open leaf rests against the mechanical stop. Eliminate any binding and potential collisions involving the motor, brackets or leaf.
- Only after a successful manual test, permanently fix the front bracket and secure the operator again. For a double-leaf gate, carry out the procedure on both leaves.
The gate must have suitable mechanical stops; the end of the piston stroke does not replace them. For a different post, adapt the anchoring method or use a suitable bracket while preserving dimensions A/B and C. Do not anchor the bracket only to the thin gate infill.
Wiring the 24 V motor
Disconnect both the mains and backup power supplies before opening the cover. Route the cable through the cable gland and strain relief. Connect the two motor wires and the PE protective conductor as shown in the diagram; connect PE to the designated grounding point, not to a motor output. Tighten the cable gland and close the cover.
With MC424LR30 connect one motor to M2. With a double-leaf gate, M2 opens first and closes last; M1 operates in the opposite sequence. The control unit must be set to the exact TOO4524 motor type according to the motor selection table . Check the direction of travel and safety inputs before commissioning .
Test before first use
After setting up the control unit, check that the mounting is secure, the full range of movement, both end stops, the correct direction of travel, photocells, STOP, response to obstacles, and safe operating forces. Keep the movement area clear during testing. Provide the user with manual release procedure and instructions for the installed control unit.
Wiring accessories according to the MC424L board
The TOO4524 drive is a 24 V motor; the terminals below are for the control unit. For supplied kits, check the marking on the installed board. Disconnect the mains and battery before wiring. EPM relay photocells are not connected as BlueBUS devices.
MC424LR10 / MCA2R10 in TOO kits
| Component | Terminals and polarity |
|---|---|
| Auxiliary 24 V DC supply | 6 = 0 V (−), 7 = +24 V DC, for accessories up to a total of 200 mA. Terminal 8 = common +24 V for inputs without Stand-by all. Check the current draw of all powered devices. |
| EPM photocells | Without Stand-by all and without photocell testing, power TX and RX between 7 (+) and 6 (−). Voltage-free RX contact C–NC connect between 8 (common) and 10/FOTO, or 11/FOTO1 or 13/AUX, if AUX is configured as FOTO2. The contact has no +/− polarity. |
| Stand-by all / photocell test | These modes are mutually exclusive. With Stand-by all power TX and RX via 5 (+) / 6 (−); the common point for safety contacts is 5. With photocell testing power TX via 5 (+) / 6 (−), up to 100 mA; power RX via 7 (+) / 6 (−), connect the RX contact from 8 to the relevant FOTO input. Connect unused tested FOTO/FOTO1/FOTO2 circuits to 5 according to the diagram for the number of pairs, not automatically to 8. |
| STOP and commands | 9/STOP is for NC or 8.2 kΩ, depending on the learned mode; the common terminal is 5 with Stand-by all 5, otherwise 8. 12/step-by-step is NO relative to 8; 13/AUX depends on the configuration. Contacts have no +/− polarity; do not apply an external voltage to the inputs. |
| Flashing light, indicator light, lock | Flashing light 24 V DC/max. 25 W: 1 = −, 2 = +. OGI indicator light 24 V DC/max. 5 W: 3 = −, 4 = +. If 3–4 is programmed as an electric lock, it supplies 12 V AC/max. 25 VA, with no fixed +/− polarity. Check the output function before connecting. |
| Radio and backup | The receiver is fitted into the SMsocket; the PS124 battery fits into its dedicated socket. They are not connected to the accessory power terminals. |
MC424LR30 / MCA2R30 with a control unit selected separately
| Component | Terminals and LR30 differences |
|---|---|
| Power supply and inputs | 6 = 0 V (−), 7 = +24 V DC for accessories, up to 200 mA; 8 = common +24 V without Stand-by all. 9/ALT is NC or 8.2 kΩ; 10/FOTO, 11/FOTO1 are NC; 12/step-by-step is NO; 13/AUX depends on the configuration. Contacts are not polarity-sensitive. |
| Stand-by all / photocell test | With Stand-by all, power TX/RX via 5 (+) / 6 (−) and the safety contacts, including ALT, share the common point 5. For photocell testing: TX 5 (+) / 6 (−), up to 100 mA; RX 7 (+) / 6 (−); RX contact from 8 to the PHOTO input. Unused tested inputs are connected to 5 according to the relevant wiring diagram. The modes are mutually exclusive. In Stand-by mode, output 7 drops to 21 V DC (±10 %), 2 W; check the current draw. |
| Outputs | Flashing light 24 V DC/max. 25 W: 1 = −, 2 = +. OGI indicator light 24 V DC/max. 5 W: 3 = −, 4 = +. When the electric lock function is used, terminals 3–4 provide 12 V AC/max. 15 VA, with no fixed +/− polarity. Check the programmed function before connecting. |
| Radio and backup | The receiver and battery use their own connectors; with an older battery and this control board, check the correct cable and the Stand-by all setting in the MC424LR30 manual. |
Photocell wiring diagrams for the specific control board
MC424LR10: Stand-by all · without Stand-by all and the photocell test · photocell test.
MC424LR30: Stand-by all · photocell test with one pair. Complete wiring diagrams, programming and setup are provided in the separate MC424LR30 manual.
After wiring, check the contact types, carry out the appropriate programming procedure, and test the safety devices during both opening and closing.
Compatible accessories
Accessories connect to the selected control unit, not directly to the motor housing. With an older control board, the connectors, radio receiver and output power supply may differ.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two 24 V TOO motors. The manual and wiring depend on the control board actually installed. | |
| Flashing light | Warns that the gate is moving. Choose the voltage and power rating to match the output of the control unit in use. | |
| Photocells | Monitor the area along the beam path. The gate's response is determined by the wiring, programming and safety input settings on the control unit. See safety device test. | |
| Remote control | Remote control compatible with the receiver's protocol. The built-in MC424LR30 receiver supports Nice Opera. Two-way operation and long range require a receiver with the relevant support. |
FLO2RE and FLO2R-S require a receiver that supports FloR. When replacing the control unit, also check that your existing remotes are compatible. Pairing INTI2 with MC424LR30. |
| Radio / Wi-Fi / GSM | Board MCA2R30 has a built-in radio receiver. Wi-Fi or GSM control is an additional interface that requires a suitable connection. |
Other Wi-Fi modules Choose according to the control unit input. Zamel control uses the SUPLA app for Android and iOS. |
| Antenna | Improves the radio receiver's range; use an antenna with the correct frequency and connector. | |
| Keypad | Code-operated control. Wired EDS requires a decoder MORX; the wireless version must be compatible with the installed receiver. | |
| Key switch | Allows the gate to be operated with a key. Connect the switch contact to a suitable control input on the control unit, following its instructions. | |
| Card readers | Control by card or key fob. Reader ETP requires a decoder MORX and a control input on the control unit. |
|
| Electric locks | Help secure the closed gate leaf. Select the lock, power supply and timing to suit the specific control unit and gate. |
|
| Backup and solar power | Battery PS124 keeps the operator running during a power outage; for MC424LR30 requires a cable CABLA11 and disable Stand-by all. Solar kit Solemyo is a standalone power supply option: do not connect it to the mains at the same time, and Stand-by all must be enabled. |
Manual release during a power outage
Open the rubber cover, insert the supplied key and turn it 90° clockwise. Then move the gate manually. To re-engage the operator, position the gate leaf approximately halfway open and turn the key 90° counterclockwise. Before operating the motor again, check that the operator is properly engaged.
Maintenance and safety
Have the motor and the entire automation system inspected no later than 6 months after commissioning, and regularly thereafter depending on usage. With the power disconnected, check the brackets, screws, corrosion, moving parts, stops and safety devices; after the inspection, carry out a functional test. Do not use the gate if the operator is damaged or encounters unusual resistance until the fault has been fixed.
Motor technical specifications
| Parameter | Value |
|---|---|
| Motor model | TOO4524 |
| Motor voltage | 24 V DC |
| Control unit power supply MC424LR30 | 230 V AC |
| Maximum length of one gate leaf | 4.5 m |
| Maximum weight of one gate leaf | 250 kg |
| Rated / maximum motor power consumption | 30 / 120 W |
| Rated / maximum current | 1.1 / 5 A |
| Rated / maximum force | 300 / 1,800 N |
| Travel speed | 0.014 m/s |
| Piston stroke | 500 mm |
| Ingress protection rating | IP54 |
| Operating temperature | −20 to +50 °C |
| Motor weight only | 5.5 kg |
| Motor dimensions | 800 × 100 × 177 mm |
| Operating mode | Continuous operation |
NICE specifications apply at an ambient temperature of 20 °C (±5 °C). The 5.5 kg weight refers to the motor only. Maximum force and power consumption are not continuous-load ratings.