NICE TOO TOO4524 – standalone operator for one gate leaf, 4.5 m/250 kg, intensive use


Product availability: within 7 days

We usually dispatch goods within 7 days.


NICE TOO TOO4524 – standalone operator for one gate leaf, 4.5 m/250 kg, intensive use
NICE-TOO4524
within 7 days
€266.78 excluding VAT
€328.14 including VAT

 pcs
Weight
6,00 kg

Description of NICE TOO TOO4524 – standalone operator for one gate leaf, 4.5 m/250 kg, intensive use

NICE TOO4524 is a standalone electromechanical operator for one gate leaf swing gate up to 4.5 m and up to 250 kg. The motor has 24 V DC and is non-reversible. In the event of a power failure, is released with a key. It is suitable for residential and light industrial use; control unit and safety devices are selected for the gate as a whole.

Quick navigation
Choosing an operatorControl unit
Kits and alternativesInstallation
Dimension CWiring
TestingAccessories
Manual releaseMaintenance
SpecificationsManual
Accessories – terminals and polarityPDF manual

When to choose this operator

The 4.5 m and 250 kg figures are the maximums for a single gate leaf. The suitability of a particular gate also depends on its operating resistance, hinge position, wind exposure, leaf infill and bracket geometry. Check suitability against the gate's actual dimensions and weight, and ensure it moves freely.

The 24 V motor is also suitable for more intensive use. Assess the permitted opening frequency and the load on the complete automation system based on the gate leaf, installation and control unit.

Control unit and gate equipment

GenerationCompatible control unit
CurrentMC424LR30 / MCA2R30 for one or two TOO 24 V motors.
Older, still availableMC424LR10 / MCA2R10. Use the manual for this generation.

Check the markings on the installed control board and use the manual for that generation. For the older MC424LR01, do not use procedures for the R10 or R30. Instructions for selecting the motor type, learning the travel limits and programming the current control unit are in the MC424LR30 manual.

The 24 V marking refers to the motor. Controller MC424LR30 connects to a 230 V AC mains supply and provides the relevant motor and auxiliary outputs; the wiring must comply with the exact manual for this unit.

NICE TOO – reference illustration of the standalone motor and brackets, according to the manufacturer

The motor is shown with front and rear brackets, connecting hardware and release key. Check the package contents before installation. Control unit, photocells and anchoring to the specific post are selected separately or according to the kit contents.

Kits for one or two gate leaves

The standalone motor is designed for one gate leaf. A double-leaf gate requires two operators. Our 24 V kits below include MC424LR10 and differ in the additional equipment included. The standalone 230 V alternative motor is shown in the centre.

Kits for 1 gate leafKits for 2 gate leaves

NICE TOO4524 kit for 1 gate leaf
1 × motor, 24 V DC

NICE TOO4524 kit for 1 gate leaf

MC424LR10 and 1 remote control INTI2.

Basic
No photocells or warning light.

With photocells
Additional photocells EPM.

With accessories
Additional EPM and a flashing light ELDC.

NICE TOO4524 kit for 2 leaves
2 × motors, 24 V DC

NICE TOO4524 kit for 2 leaves

MC424LR10 and 1 remote control INTI2.

Basic
Without photocells or a flashing light.

With photocells
Additional photocells EPM.

With accessories
Additional EPM and a flashing light ELDC.

Limits 4.5 m and 250 kg are assessed separately for each leaf. With two leaves, the limit for an individual motor does not increase. Add the required items to the basic kit safety devices according to the specific gate.

Mounting the brackets and positioning the operator

First determine the hinge and rear bracket positions, then check clearance throughout the gate's full range of movement. Dimensions A and B determine the achievable opening angle and force profile. The brackets must be securely fixed to a suitably engineered structure; the post dimensions alone are not enough to assess the anchoring. Before permanently fixing the brackets, check that the gate moves freely by hand without binding.

NICE TOO operator mounting dimensions A/B; use the relevant rows for TOO4524

TOO4524 mounting dimensions

Opening angleA [mm]B [mm]
90°200250
110°170170

For the specific post and bracket, see TOO4524 anchoring bracket dimensions. For an unusual hinge position or outward opening, design a suitable mounting arrangement that preserves dimensions A, B and C and keeps the motor and brackets clear of the leaf's movement.

Dimension C with the gate closed

With the leaf closed, measure the distance C < 1 300 mm. The value must be less than the stated limit; it must not equal or exceed it. Keep the selected A/B combination as well.

NICE TOO – measuring dimension C with the gate closed

Mounting and checking the movement

  1. Select one A/B combination for the specific operator and opening angle. Fix the rear bracket to a sturdy post or suitably engineered support structure, then attach the operator to it.
  2. Operator release it with the key, fully extend the piston as shown in the NICE drawing, then temporarily position the front bracket against the rigid gate frame.
  3. Level the motor and connect the piston to the front bracket. Check dimension C when closed, and check that the leaf moves freely throughout its full travel.
  4. Check that the open leaf rests against the mechanical stop. Eliminate any binding and potential collisions involving the motor, brackets or leaf.
  5. Only after a successful manual test, permanently fix the front bracket and secure the operator again. For a double-leaf gate, carry out the procedure on both leaves.

The gate must have suitable mechanical stops; the end of the piston stroke does not replace them. For a different post, adapt the anchoring method or use a suitable bracket while preserving dimensions A/B and C. Do not anchor the bracket only to the thin gate infill.

NICE TOO – manually checking gate opening and the mechanical stop

NICE TOO – mounting the rear bracket and 24 V motor

NICE TOO – testing and mounting the front bracket on the gate leaf

Wiring the 24 V motor

Disconnect both the mains and backup power supplies before opening the cover. Route the cable through the cable gland and strain relief. Connect the two motor wires and the PE protective conductor as shown in the diagram; connect PE to the designated grounding point, not to a motor output. Tighten the cable gland and close the cover.

With MC424LR30 connect one motor to M2. With a double-leaf gate, M2 opens first and closes last; M1 operates in the opposite sequence. The control unit must be set to the exact TOO4524 motor type according to the motor selection table . Check the direction of travel and safety inputs before commissioning .

Wiring the terminal block of the NICE TOO 24 V motor and the protective conductor

Test before first use

After setting up the control unit, check that the mounting is secure, the full range of movement, both end stops, the correct direction of travel, photocells, STOP, response to obstacles, and safe operating forces. Keep the movement area clear during testing. Provide the user with manual release procedure and instructions for the installed control unit.

Wiring accessories according to the MC424L board

The TOO4524 drive is a 24 V motor; the terminals below are for the control unit. For supplied kits, check the marking on the installed board. Disconnect the mains and battery before wiring. EPM relay photocells are not connected as BlueBUS devices.

MC424LR10 / MCA2R10 in TOO kits

ComponentTerminals and polarity
Auxiliary 24 V DC supply6 = 0 V (−), 7 = +24 V DC, for accessories up to a total of 200 mA. Terminal 8 = common +24 V for inputs without Stand-by all. Check the current draw of all powered devices.
EPM photocellsWithout Stand-by all and without photocell testing, power TX and RX between 7 (+) and 6 (−). Voltage-free RX contact C–NC connect between 8 (common) and 10/FOTO, or 11/FOTO1 or 13/AUX, if AUX is configured as FOTO2. The contact has no +/− polarity.
Stand-by all / photocell testThese modes are mutually exclusive. With Stand-by all power TX and RX via 5 (+) / 6 (−); the common point for safety contacts is 5. With photocell testing power TX via 5 (+) / 6 (−), up to 100 mA; power RX via 7 (+) / 6 (−), connect the RX contact from 8 to the relevant FOTO input. Connect unused tested FOTO/FOTO1/FOTO2 circuits to 5 according to the diagram for the number of pairs, not automatically to 8.
STOP and commands9/STOP is for NC or 8.2 kΩ, depending on the learned mode; the common terminal is 5 with Stand-by all 5, otherwise 8. 12/step-by-step is NO relative to 8; 13/AUX depends on the configuration. Contacts have no +/− polarity; do not apply an external voltage to the inputs.
Flashing light, indicator light, lockFlashing light 24 V DC/max. 25 W: 1 = −, 2 = +. OGI indicator light 24 V DC/max. 5 W: 3 = −, 4 = +. If 3–4 is programmed as an electric lock, it supplies 12 V AC/max. 25 VA, with no fixed +/− polarity. Check the output function before connecting.
Radio and backupThe receiver is fitted into the SMsocket; the PS124 battery fits into its dedicated socket. They are not connected to the accessory power terminals.

MC424LR30 / MCA2R30 with a control unit selected separately

ComponentTerminals and LR30 differences
Power supply and inputs6 = 0 V (−), 7 = +24 V DC for accessories, up to 200 mA; 8 = common +24 V without Stand-by all. 9/ALT is NC or 8.2 kΩ; 10/FOTO, 11/FOTO1 are NC; 12/step-by-step is NO; 13/AUX depends on the configuration. Contacts are not polarity-sensitive.
Stand-by all / photocell testWith Stand-by all, power TX/RX via 5 (+) / 6 (−) and the safety contacts, including ALT, share the common point 5. For photocell testing: TX 5 (+) / 6 (−), up to 100 mA; RX 7 (+) / 6 (−); RX contact from 8 to the PHOTO input. Unused tested inputs are connected to 5 according to the relevant wiring diagram. The modes are mutually exclusive. In Stand-by mode, output 7 drops to 21 V DC (±10 %), 2 W; check the current draw.
OutputsFlashing light 24 V DC/max. 25 W: 1 = −, 2 = +. OGI indicator light 24 V DC/max. 5 W: 3 = −, 4 = +. When the electric lock function is used, terminals 3–4 provide 12 V AC/max. 15 VA, with no fixed +/− polarity. Check the programmed function before connecting.
Radio and backupThe receiver and battery use their own connectors; with an older battery and this control board, check the correct cable and the Stand-by all setting in the MC424LR30 manual.

Photocell wiring diagrams for the specific control board

MC424LR10: Stand-by all · without Stand-by all and the photocell test · photocell test.

MC424LR10: photocell test TX to 5 and 6, RX power supply to 7 and 6, contact from 8 to the PHOTO input

MC424LR30: Stand-by all · photocell test with one pair. Complete wiring diagrams, programming and setup are provided in the separate MC424LR30 manual.

After wiring, check the contact types, carry out the appropriate programming procedure, and test the safety devices during both opening and closing.

Compatible accessories

Accessories connect to the selected control unit, not directly to the motor housing. With an older control board, the connectors, radio receiver and output power supply may differ.

What Why Type
Control unit

Controls one or two 24 V TOO motors. The manual and wiring depend on the control board actually installed.

  • Current model MC424LR30 (MCA2R30). MC424LR10 (MCA2R10) is a compatible earlier generation and is also available in our range.
Flashing light

Warns that the gate is moving. Choose the voltage and power rating to match the output of the control unit in use.

  • LED flashing light with antenna ELDC
  • Multifunction light WLT
Photocells

Monitor the area along the beam path. The gate's response is determined by the wiring, programming and safety input settings on the control unit. See safety device test.

  • Wired relay type - EPM
  • Reflective relay type - EPMOR
  • Wired relay type EPS
  • Antivandal wired relay type - EPMA
  • Wired relay type EPL
  • Wired relay type - F210
  • Wired/wireless relay type - FT210
Remote control

Remote control compatible with the receiver's protocol. The built-in MC424LR30 receiver supports Nice Opera. Two-way operation and long range require a receiver with the relevant support.

FLO2RE and FLO2R-S require a receiver that supports FloR. When replacing the control unit, also check that your existing remotes are compatible. Pairing INTI2 with MC424LR30.

Radio / Wi-Fi / GSM

Board MCA2R30 has a built-in radio receiver. Wi-Fi or GSM control is an additional interface that requires a suitable connection.

Other Wi-Fi modules Choose according to the control unit input. Zamel control uses the SUPLA app for Android and iOS.

Antenna

Improves the radio receiver's range; use an antenna with the correct frequency and connector.

  •  integrated into the flashing light ELDC
  • standalone antenna ABFKIT
Keypad

Code-operated control. Wired EDS requires a decoder MORX; the wireless version must be compatible with the installed receiver.

Key switch

Allows the gate to be operated with a key. Connect the switch contact to a suitable control input on the control unit, following its instructions.

  • surface-mounted, with standard cylinder EKS
  • surface-mounted, with European cylinder, EKSEU
  • flush-mounted, with standard cylinder EKSI
  • flush-mounted, with European cylinder EKSIEU
Card readers

Control by card or key fob. Reader ETP requires a decoder MORX and a control input on the control unit.

  • ERA Transponder Reader ETP
Electric locks

Help secure the closed gate leaf. Select the lock, power supply and timing to suit the specific control unit and gate.

Backup and solar power

Battery PS124 keeps the operator running during a power outage; for MC424LR30 requires a cable CABLA11 and disable Stand-by all. Solar kit Solemyo is a standalone power supply option: do not connect it to the mains at the same time, and Stand-by all must be enabled.

  • PS124 with CABLA11 – backup power during mains outages.
  • SYKCE30 – standalone solar power, independent of the mains.

Manual release during a power outage

Open the rubber cover, insert the supplied key and turn it 90° clockwise. Then move the gate manually. To re-engage the operator, position the gate leaf approximately halfway open and turn the key 90° counterclockwise. Before operating the motor again, check that the operator is properly engaged.

NICE TOO – manual motor release

Maintenance and safety

Have the motor and the entire automation system inspected no later than 6 months after commissioning, and regularly thereafter depending on usage. With the power disconnected, check the brackets, screws, corrosion, moving parts, stops and safety devices; after the inspection, carry out a functional test. Do not use the gate if the operator is damaged or encounters unusual resistance until the fault has been fixed.

Motor technical specifications

ParameterValue
Motor modelTOO4524
Motor voltage24 V DC
Control unit power supply MC424LR30230 V AC
Maximum length of one gate leaf4.5 m
Maximum weight of one gate leaf250 kg
Rated / maximum motor power consumption30 / 120 W
Rated / maximum current1.1 / 5 A
Rated / maximum force300 / 1,800 N
Travel speed0.014 m/s
Piston stroke500 mm
Ingress protection ratingIP54
Operating temperature−20 to +50 °C
Motor weight only5.5 kg
Motor dimensions800 × 100 × 177 mm
Operating modeContinuous operation

NICE specifications apply at an ambient temperature of 20 °C (±5 °C). The 5.5 kg weight refers to the motor only. Maximum force and power consumption are not continuous-load ratings.

NICE TOO4524 motor dimensions according to the manufacturer

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE TOO TOO4524 – standalone operator for one gate leaf, 4.5 m/250 kg, intensive use

Product: NICE TOO TOO4524 – standalone operator for one gate leaf, 4.5 m/250 kg, intensive use
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.