NICE TOO TOO3024 - standalone operator for one leaf, 3 m/300 kg, intensive use
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€139.26 including VAT
| Weight |
|---|
| 6,00 kg |
Description of NICE TOO TOO3024 - standalone operator for one leaf, 3 m/300 kg, intensive use
NICE TOO3024 is a standalone electromechanical operator for one gate leaf swing gate up to 3 m and up to 300 kg. The motor has 24 V DC and is non-reversible. In the event of a power outage, it is released using a key. It is suitable for both residential and light industrial use; control unit and safety devices are selected according to the complete gate.
When to choose this operator
The 3 m and 300 kg figures are the maximums for a single gate leaf. The suitability of a specific gate also depends on resistance to movement, hinge position, wind exposure, leaf infill and bracket geometry. Check the selection against the gate's actual dimensions, weight and freedom of movement.
The 24 V motor is also suitable for more intensive use. Assess the permitted opening frequency and the load on the complete automation system based on the gate leaf, installation and control unit.
Control unit and gate equipment
| Generation | Compatible control unit |
|---|---|
| Current | MC424LR30 / MCA2R30 for one or two TOO 24 V motors. |
| Older, still available | MC424LR10 / MCA2R10. Use the manual for this generation. |
Check the marking on the installed control board and use the manual for that generation. For the older MC424LR01, do not use procedures for the R10 or R30. For motor type selection, travel learning and programming of the current control unit, see the MC424LR30 manual.
The 24 V marking applies to the motor. Control unit MC424LR30 connects to a 230 V AC mains supply and provides the relevant motor and auxiliary outputs; wiring must comply with its specific manual.
The motor is shown with front and rear brackets, connecting parts and release key. Check the supplied package before installation. Control unit, photocells and the fixings for the specific post are selected separately or according to the kit contents.
Kits for one or two gate leaves
The standalone motor is designed for one gate leaf. A double-leaf gate requires two operators. Our 24 V kits below include MC424LR10 and differ in the additional equipment included. A standalone 230 V alternative motor is shown in the middle.
| Kits for 1 gate leaf | Kits for 2 gate leaves |
|---|---|
NICE TOO3024 kit for 1 gate leaf MC424LR10 and 1 remote control INTI2. Basic With photocells With accessories | NICE TOO3024 kit for 2 leaves MC424LR10 and 1 remote control INTI2. Basic With photocells With accessories |
Limits 3 m and 300 kg are assessed separately for each leaf. With two leaves, the limit for one motor does not increase. Add the necessary items to the basic kit safety devices according to the specific gate.
Mounting the brackets and positioning the operator
First determine the position of the hinge and rear bracket, then check clearance for the gate’s full range of movement. Dimensions A and B determine the achievable opening angle and force profile. The brackets must be securely fastened to a suitably assessed structure; the post dimensions alone are not enough to assess the anchoring. Before permanently fastening the brackets, check that the gate moves freely by hand without catching.
TOO3024 mounting dimensions
| Opening angle | A [mm] | B [mm] |
|---|---|---|
| 90° | 95 | 270 |
| 90° | 195 | 200 |
| 110° | 150 | 150 |
For the specific post and bracket, see TOO3024 mounting bracket dimensions. For an unusual hinge position or outward opening, design a suitable mounting arrangement that preserves dimensions A, B and C and keeps the motor and brackets clear of the leaf’s movement.
Dimension C with the gate closed
With the leaf closed, measure the distance C < 1 100 mm. The value must be less than the stated limit; it must not equal or exceed it. Also maintain the selected A/B combination.
Mounting and checking the movement
- Select one A/B combination for the specific operator and angle. Secure the rear bracket to a sturdy post or suitably designed supporting structure, then attach the operator to it.
- Operator unlock it with the key, fully extend the piston as shown in the NICE drawing, and temporarily position the front bracket on the sturdy gate frame.
- Level the motor horizontally and connect the piston to the front bracket. Check dimension C when closed, and check that the leaf moves freely throughout its full travel.
- Check that the open leaf comes to rest against the mechanical stop. Eliminate any catching or collisions involving the motor, brackets or leaf.
- Only after a successful manual test should you permanently secure the front bracket and relock the operator. For a double-leaf gate, repeat the procedure for both leaves.
The gate must have suitable mechanical stops for both the open and closed positions mechanical stops; the end of the piston’s travel does not replace them. For a different post, adapt the anchoring method or use a suitable bracket so that dimensions A/B and C are maintained. Do not fasten the bracket to the thin gate infill alone.
Connecting the 24 V motor
Disconnect both the mains and backup power supplies before opening the cover. Route the cable through the cable gland and strain relief. Connect the two motor wires and the PE protective conductor as shown in the diagram; PE must be connected to the designated earthing point, not to a motor output. Tighten the cable gland and close the cover.
With MC424LR30 one motor connects to M2. With two leaves, M2 opens first and closes last; M1 operates in the opposite order. The control unit must be set to the exact TOO3024 type according to motor selection tables . Check the direction of travel and safety inputs before putting it into operation .
Test before first use
After configuring the control unit, check that it is securely mounted, the full travel, both stops, the correct direction of travel, photocells, STOP, response to obstacles, and safety forces. Keep the travel area clear during testing. Give the user manual release procedure and instructions for the installed control unit.
Connecting accessories according to the MC424L board
The TOO3024 drive is a 24 V motor; the terminals below are for the control unit. For supplied kits, check the model of the installed board. Disconnect the mains supply and battery before wiring. EPM relay photocells do not connect as BlueBUS devices.
MC424LR10 / MCA2R10 in TOO kits
| Component | Terminals and polarity |
|---|---|
| Auxiliary 24 V DC | 6 = 0 V (−), 7 = +24 V DC, for accessories up to a total of 200 mA. Terminal 8 = common +24 V for inputs without Stand-by all. Check the current draw of all powered devices. |
| EPM photocells | Without Stand-by all and without photocell testing, power TX and RX between 7 (+) and 6 (−). RX volt-free contact C–NC connect between 8 (common) and 10/FOTO, or 11/FOTO1 or 13/AUX, if AUX is configured as FOTO2. The contact has no +/− polarity. |
| Stand-by all / photocell test | These modes are mutually exclusive. With Stand-by all power TX and RX via 5 (+) / 6 (−); the common point for the safety contacts is 5. With photocell testing, power TX via 5 (+) / 6 (−), up to 100 mA; power RX via 7 (+) / 6 (−), connect the RX contact from 8 to the relevant FOTO input. Connect unused monitored FOTO/FOTO1/FOTO2 inputs to 5 according to the diagram for the number of pairs, not automatically to 8. |
| STOP and command inputs | 9/STOP is for NC or 8.2 kΩ, depending on the learned mode; the common terminal is 5, with Stand-by all; otherwise, 8. 12/step-by-step is NO relative to 8; 13/AUX depends on the configuration. The contacts are not polarized; do not apply an external voltage to the inputs. |
| Flashing light, indicator light, lock | Flashing light 24 V DC/max. 25 W: 1 = −, 2 = +. OGI indicator light 24 V DC/max. 5 W: 3 = −, 4 = +. If 3–4 is programmed as an electric lock, it supplies 12 V AC/max. 25 VA, with no fixed +/− polarity. Check the output function before connecting. |
| Radio receiver and backup | The receiver plugs into the SMconnector; the PS124 battery plugs into its dedicated connector. They do not connect to the accessory power terminals. |
MC424LR30 / MCA2R30 with a separately selected control unit
| Component | Terminals and LR30 differences |
|---|---|
| Power supply and inputs | 6 = 0 V (−), 7 = +24 V DC for accessories, max. 200 mA; 8 = common +24 V without Stand-by all. 9/ALT is NC or 8.2 kΩ; 10/FOTO, 11/FOTO1 are NC; 12/step-by-step NO; 13/AUX depending on the configuration. The contacts are not polarized. |
| Stand-by all / photocell test | With Stand-by all, power TX/RX via 5 (+) / 6 (−) and the safety contacts, including ALT, share the common point 5. With photocell testing: TX 5 (+) / 6 (−), maximum 100 mA; RX 7 (+) / 6 (−); RX contact from 8 to the PHOTO input. Unused tested inputs are connected to 5 according to the relevant diagram. The modes are mutually exclusive. In Stand-by, output 7 drops to 21 V DC (±10 %), 2 W; check the current draw. |
| Outputs | Flashing light 24 V DC/max. 25 W: 1 = −, 2 = +. OGI indicator light 24 V DC/max. 5 W: 3 = −, 4 = +. When using the electric lock function, terminals 3–4 supply 12 V AC/max. 25 VA, with no fixed +/− polarity. Check the programmed function before connecting. |
| Radio and backup | The receiver and battery use their own connectors; with an older battery and this control board, check that the cable and Stand-by all setting are correct according to the MC424LR30 manual. |
Photocell wiring diagrams for the specific control board
MC424LR10: Stand-by all · without Stand-by all and photocell testing · photocell testing.
MC424LR30: Stand-by all · photocell test with one pair. Complete wiring diagrams, setup and configuration are provided in the separate MC424LR30 manual.
After wiring, check the contact types, carry out the relevant setup procedure, and test the safety devices during both opening and closing.
Compatible accessories
Accessories connect to the selected control unit, not directly to the motor housing. Connectors, the radio receiver, and output power may differ on older control boards.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two 24 V TOO motors. Manual and wiring depend on the control board actually installed. | |
| Flashing light | Alerts you when the gate is moving. Choose the voltage and power rating to match the output of the control unit used. | |
| Photocells | Monitor the area along the beam path. The gate response is determined by the wiring, setup procedure, and safety input configuration of the control unit. See safety device test. | |
| Transmitter | Remote control compatible with the receiver protocol. The built-in MC424LR30 receiver supports Nice Opera. Two-way communication and extended range require a receiver with the relevant support. |
FLO2RE and FLO2R-S require a receiver that supports FloR. When replacing the control unit, also check that your existing remote controls are compatible. Pairing INTI2 with MC424LR30. |
| Radio / Wi-Fi / GSM | Board MCA2R30 has a built-in radio receiver. Wi-Fi or GSM control is an additional interface that requires a suitable connection. |
Other Wi-Fi modules should be selected according to the control unit's input. Zamel control uses the SUPLA app for Android and iOS. |
| Antenna | Improves the radio receiver's range; use an antenna with the correct frequency and connector. | |
| Keypad | Code-based access control. Wired EDS requires a decoder MORX; the wireless version must be compatible with the installed receiver. | |
| Key switch | Allows you to operate the gate with a key. Connect the switch contact to a suitable control input on the control unit, following its instructions. | |
| Card readers | Access control with a card or key fob. Reader ETP requires a decoder MORX and a control input on the control unit. |
|
| Electric locks | Help secure the gate leaf in the closed position. The lock, power supply and timing must be selected to suit the specific control unit and gate. |
|
| Backup and solar power | Battery PS124 keeps the operator running during a power outage; with the MC424LR30 requires a cable CABLA11 and switch-off Stand-by all. Solar kit Solemyo is a standalone power supply option: the mains supply must not be connected at the same time, and Stand-by all must be enabled. |
Manual release in the event of a power failure
Open the rubber cover, insert the supplied key and turn it 90° clockwise. You can then move the gate manually. To re-engage the operator, move the gate leaf to approximately halfway open and turn the key 90° counterclockwise. Before operating the motor again, check that the operator is properly engaged.
Maintenance and safety
Have the motor and the entire automation system inspected no later than 6 months after commissioning, and regularly thereafter depending on usage. With the power disconnected, check the brackets, screws, corrosion, moving parts, stops and safety devices; perform a function test after the inspection. If the operator is damaged or encounters unusual resistance, do not use the gate until the fault has been fixed.
Motor technical specifications
| Parameter | Value |
|---|---|
| Motor model | TOO3024 |
| Motor voltage | 24 V DC |
| Control unit power supply MC424LR30 | 230 V AC |
| Maximum length of one gate leaf | 3 m |
| Maximum weight of one gate leaf | 300 kg |
| Rated / maximum motor power input | 30 / 120 W |
| Rated / maximum current | 1.1 / 5 A |
| Rated / maximum force | 300 / 1,800 N |
| Travel speed | 0.014 m/s |
| Piston stroke | 400 mm |
| Ingress protection rating | IP54 |
| Operating temperature | −20 to +50 °C |
| Motor weight only | 5.5 kg |
| Motor dimensions | 700 × 100 × 177 mm |
| Operating mode | Continuous operation |
NICE specifications apply at an ambient temperature of 20 °C (±5 °C). The 5.5 kg weight refers to the motor only. Maximum force and power input are not continuous-duty ratings.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]