NICE SNA4 - replacement control unit for NICE Spinbus SN6041 operators
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
for the question
€185.83 including VAT
| Weight |
|---|
| 0,50 kg |
Description of NICE SNA4 - replacement control unit for NICE Spinbus SN6041 operators
NICE SNA4 control unit is compatible with garage door operators NICE Spinbus SN6041. Includes a connector type SM for connecting radio signal receiver (SMXI, OXI,...) from remote controls (Flor, Era Flor, Era One, Era Inti,...).
Supports the technology BlueBus, which makes it easy to connect additional devices (photocells, warning light, card readers, key switches, etc.) using only a two-core cable, with no need to observe polarity.
Thanks to the 24V technology, it is also suitable for the NICE Solemyo solar system, which provides power even in locations without access to an electricity supply. It is also possible to power the control unit from the NICE PS124 backup battery, which allows several garage door opening and closing cycles for a few hours after a power failure. When standby mode is enabled, the control unit with a connected control signal receiver uses only 2 W (when powered by the PS124 battery, or the Solemyo solar system, power consumption is only 0.1 W).
Supports NICE Opera technology. Diagnostics using warning light.
Once the gate leaf length has been assessed, the acceleration and deceleration intervals for opening and closing are set automatically. You can also adjust the force, speed etc. See drive control unit programming. Obstacle detection throughout the gate leaf's movement ensures safe operation of the motors.
NICE SNA4 control unit is suitable for Slovakia's climate and meets all European safety standards.
Accessories compatible with the NICE SNA4 control unit
We recommend purchasing these compatible optional accessories for the control unit:
| What | Why | Type |
|---|---|---|
| Warning light | The warning light flashes to signal gate movement—ideal for driveways with limited visibility. It also has a built-in antenna for extended remote-control range. | |
| Photocells | When closing, they detect obstacles and stop the gate—preventing it from hitting cars or people. | - MoonBUS (MOFB) |
| Transmitter |
For remote control of the gate. |
- FloR (Flo2R-s, Flo4R-s) |
| Receiver | Required for remote operation of the gate. | - OXI - SMXI |
| Antenna | For improved remote-control range. | - integrated into the warning light LUCYB, MLBT - ABFKIT antenna only, or ABF |
| Keypad | If you forget your remote control, or if many vehicles or people visit and you don't want to give everyone a remote control or have to open the gate yourself. | - MOTXR |
Manual for the NICE SNA4 control unit and NICE Spinbus SN6041 operator
Download the manual for the NICE SNA4 control unit and NICE Spinbus SN6041 operator here:
Manual for the NICE SNA4 control unit and NICE Spinbus SN6041 operator
Wiring the NICE SNA4 control unit for the NICE Spinbus SN6041 operator
...to the mains
Simply plug the operator into a socket.
...accessory devices
Warning: Before connecting, disconnecting or changing the wiring of accessory devices, remember to disconnect the power supply at the circuit breaker, by removing the power fuse, or by disconnecting the backup battery.
NICE SNA4 control unit for the operator NICE Spinbus SN6041 provides the following inputs and outputs for accessory devices:
| Input/output | Description | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Programmable output whose operation can be set by programming level II, option L4; see Level II programming, L4 – Output indicator. It can be programmed for the following devices:
|
|||||||||||||
| Input for parallel connection of compatible devices using BlueBUS a two-core cable that carries both the power supply and the communication signal. | |||||||||||||
| STOP (Stop) |
Input for devices that stop the gate's movement. The following devices can be connected:
|
||||||||||||
| Input for devices that operate the gate step by step (see Step-by-step gate movement). Normally open devices (NO) can be connected. | |||||||||||||
| OPEN (Open) |
Input for devices that control the gate-opening movement (see Gate opening). Normally open (NO) devices can be connected. | ||||||||||||
| AERIAL (Antenna) |
input for the radio receiver antenna. The antenna is usually built into the warning beacon, for example the NICE LUCYB, NICE MLBT, or you can use a separate external antenna, such as the NICE ABFKIT. |
Gate-opener fuses
![]() |
In the gate opener there are two fuses:
|
Standard wiring diagram:
Wiring
Route the cables to the control unit and connect them as follows:
| 1. Press the white cover in and turn it | 2. Thread the cables through the opening, pass the antenna cable through the side eyelet, and connect all the cables. |
|---|---|
![]() |
![]() |
Gate-opener photocells
Highly user-friendly BlueBUS technology allows you to power and control up to 6 pairs of photocells using a two-core cable.
WIRING MULTIPLE PAIRS OF PHOTOCELLS NICE MOFB TO THE DATA NETWORK NICE BLUEBUS
Position the photocells around the gate or door according to the example layouts for the complete wiring, and set the jumpers according to the jumper table for the NICE MOFB photocells of the gate opener. To prevent interference between pairs positioned close to one another, make sure to follow these example layouts, and observe the orientation of the transmitters TX and receivers RX. Wire the photocells in parallel as shown (polarity does not need to be observed):
Example photocell wiring layout
| Sectional garage door | Up-and-over garage door |
|---|---|
![]() |
![]() |
If you want the photocells to operate as gate openers (see FA1 and FA2 in the figure), i.e. when a vehicle drives between their optical axes, causing the gate to open, you need to disconnect link A on both the transmitter TX and receiver RX, see figure:
Jumper table for NICE MOFB gate-opener photocells
![]() |
Connecting multiple pairs of photocells to the BlueBUS system is done by setting different jumper combinations, with each connected pair requiring a unique jumper combination. Make sure that no two pairs in the same BlueBUS data network have the same combination. For each pair of photocells, set the transmitter TX and receiver RX jumpers to the same value. If a jumper setting uses only one jumper, always place the other one in the unused-jumper compartment, as shown in the figure on the left. |
| Photocell pair designation | Jumper setting using a jumper combination |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| FOTO 2 II | ![]() |
|
FOTO 3 WARNING: UNPERMITTED CONFIGURATION! |
![]() |
|
FA1 |
![]() |
|
FA2 |
![]() |
If the photocell needs to be replaced for any reason, simply set it to the same jumper as the original one; there is no need to perform the device-learning procedure.
Radio receiver for gate operators
![]() |
SNA4 control unit NICE Spinbus SN6041 operator features an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for receiving commands transmitted from remote controls, and is therefore required to operate the sliding gate remotely with a remote control. |
Pairing remote controls with the operator
Visit our guide to pairing a remote control with the operator, or click:
Learning the connected operator devices
After connecting, disconnecting or changing the wiring of any accessories at the BlueBUS inputs and STOP the accessory learning procedure. The operator will alert you when this procedure is required by flashing LEDs L1 and L2.
![]() |
|
Gate leaf length learning
For the gate to operate correctly (in particular, to calculate acceleration and deceleration distances and partial opening), the operator must determine the length of the gate leaf itself. During this procedure, the operator moves the gate from one end stop to the other and determines the gate length.
Programming the operator
The SNA4 control unit for the Spinbus SN6041 operator lets you program several functions, either by enabling or disabling a function using Level I programming., or by setting a default parameter using Level II programming.
The SNA4 control unit has three buttons for operating and programming the operator:
![]() |
Button | Use |
|---|---|---|
| Open | The button allows you to command the gate opener to open the gate. It is also used during programming to move the value of the parameter being programmed up. | |
| Stop/Set | The button allows you to command the gate opener to stop the gate. Press and hold for 5 seconds to enter Level I programming. Press and hold again to enter Level II programming. for the current LED. | |
| Close | The button allows you to command the gate opener to close the gate. It is also used during programming to move the value of the parameter being programmed down. |
Level I Programming
In Level I, programming turns the selected function on or off. When a function is enabled, the corresponding LED on the control unit lights up. All functions are disabled by default.
To enter Level I programming, press and hold the “Stop/Set” button for about 5 seconds, until LED L1 starts flashing. Then use the “Open” and “Close” buttons to move the current LED up or down. You have 10 seconds for each operation; otherwise, the gate opener will exit programming mode. When the flashing LED is above the LED for the function you want to enable or disable, press the “Stop/Set” button once to make it flash faster (function enabled) or slower (function disabled), then leave it as it is and let the gate opener exit programming mode within 10 seconds. If everything went correctly, the LED for the selected function will remain lit.
List of functions that can be enabled or disabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing |
After a set period (adjusted in “Level II Programming – Pause duration”), the gate starts closing automatically after it has been opened. When this function is disabled, the gate can only be operated by a command from the gate remote control or similar. |
| L2 | Close after photocells are cleared |
This function keeps the gate open only for the time needed for a vehicle to pass through. Once the photocells are cleared (the vehicle has passed through), the gate starts closing automatically after 5 seconds. This function behaves in one of two ways, depending on whether automatic closing is enabled (see the previous function). Automatic closing enabled – the gate stops when the photocells are cleared and starts closing after 5 seconds. This means it does not have to open fully. |
| L3 | Motor force |
This function affects the motor’s sensitivity to obstacles. If this function is disabled, the gate opener is less sensitive, which is suitable for larger and heavier gates.. If your gate is small and lightweight, you can enable this function.. |
| L4 | Standby mode |
This function minimizes electricity consumption. It is especially useful when powered by a backup battery (e.g. NICE PS124). When this function is enabled, one minute after the gate’s last movement, the control unit switches off the BlueBUS input (and therefore all devices connected to it), as well as all LEDs except the BlueBUS LED, which will flash slowly. In this state, if a command is received, the control unit first restarts and only then carries it out. |
Level II Programming
In Level II, programming sets values for the functions (these functions differ from those in ).).
Forget about Level I programming. To enter Level II programming, press and hold the “Stop/Set” button for about 5 seconds, until LED L1. starts flashing. Then use the “Open” and “Close” buttons to move the current LED up or down. You have 10 seconds for each operation; otherwise, the gate opener will exit programming mode. When the flashing LED is above the LED for the function whose parameter you want to set, press and hold the “Stop/Set” button to enter the settings for that LED. The LED that remains lit (while you continue holding “Stop/Set”) indicates the current parameter value. You can increase or decrease this value using the “Open” or "Close” button (while continuing to hold “Stop/Set”), then release the “Stop/Set” button and leave it as it is, allowing the gate opener to exit programming mode within 10 seconds. To check that everything went correctly, repeat the procedure without changing the parameter value.
List of functions with adjustable settings:
|
Input LED — Name |
Setting LED — Value |
|---|---|
| L1 — Pause duration If the value is “Automatic closing“ in Level I programming. |
L1 — 10 seconds L2 — 20 seconds L3 — 40 seconds L4 — 80 seconds |
|
Sets the gate movement sequence triggered by repeatedly pressing, for example, a button on the gate remote, or by activating the STEP-BY-STEP input (also referred to as P.P., or Step-by-step). |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Condominium L4 — Hold-to-run |
|
Sets the gate speed during normal operation (excluding gate acceleration and deceleration). |
L1 — Very slow (55%) L2 — Slow (70%) L3 — Medium (85%)) L4 — Fast (100%) |
|
Sets when a signal should be sent to the FLASH output . |
L1 — Gate-open indicator L2 — Flashing warning light L3 — Electromechanical lock L4 — Electromagnetic lock |
Connecting additional external devices to the operator
![]() |
If you need to connect additional devices to the operator that require an external power supply (e.g. indicator lighting, key switch, magnetic cards, etc.), connect the device as shown in the diagram. The supplied voltage is 24Vdc -30% to +50%, with a maximum current of 100mA. |
Special operator functions
Gate held open
If a command to the STEP-BY-STEP input (also referred to as P.P. or Step-by-step) lasts longer than 3 seconds, the control unit will keep the gate open for as long as the command is active. This function is particularly useful when used with a timer.
Forced operation
If a safety device fails, or an obstruction that cannot be removed gets into the beam of the photocells and the gate will not move for safety reasons, you can activate the “Hold-to-run” mode, either permanently in Level II programming. by setting L2 — Step-by-step mode to L4 — Hold-to-run, or temporarily:
- Send a command to the gate (using aremote control,, key switch, etc.)
- If there is a problem, the gate will not move and the warning light will probably indicate a fault.
- Therefore, within 3 seconds of the previous command, send the command again and hold it.
- The gate will move while you hold the command and stop when you release it.
Troubleshooting the operator
If anything is unclear or you have any other issue, feel free to contact our technical support team for NICE operators.
Depending on the nature of the problem
During installation (or if the operator fails), you may encounter one of the following problems:
|
Problem |
Possible solution |
|---|---|
|
The gate does not respond to the remote control command, and the LED on the remote control does not light up. |
Check whether the batteries in the operator remote control are working; if not, replace them. Refer to the manual for the specific remote control for instructions. |
|
The gate does not respond to the remote control command, but the LED on the remote control lights up. |
Check whether the remote control has been stored in the memory of the receiver; if it has, try working correctly, or try remote control programming it again. |
|
The gate does not move and the BlueBUS LED does not flash.
|
Check whether the operator is receiving 230V power. If so, test both fuses and, if necessary, replace them with new ones of the same rating. |
|
The gate does not move and the warning light does not flash. |
Check whether the operator has registered the command at all. When a command is sent using the remote control, the BlueBUS LED should flash quickly twice. If the command is sent by another device via the STEP-BY-STEP input the corresponding indicator should light up STEP-BY-STEP LED. |
|
The gate does not move and the warning light flashes several times. |
Count the number of flashes and see Diagnostics using the warning light flashes. |
|
The gate starts moving, but stops immediately and starts moving in the opposite direction. |
The programmed motor force is probably too low for your gate. Check that there are no obstacles preventing the gate from moving, and increase the drive force if necessary. |
|
The gate starts, but the warning light does not work. |
Check whether there is voltage at the FLASH output during gate operation (the voltage level is not important, approx. 10-30Vdc). If there is voltage at the output, the problem is likely with the warning light (or another device); try replacing it with a similar one to see if it works. If there is no voltage at the output, the FLASH output may be overloaded. Check whether the wiring has short-circuited. |
Diagnostics using the warning light flashes
During gate operation warning light flashes regularly once every second. If a problem occurs, the warning light signals an error with two successive series of faster flashes.
|
Flash sequence |
Error |
Solution |
|---|---|---|
|
1 flash 1-second pause 1 flash |
BlueBUS error
|
The devices connected to the BlueBUS input do not match those detected during the device detection phase.. Repeat the detection phase. If that does not help, try once more; otherwise, use the process of elimination to find the faulty device and replace it (purchase, claim under warranty, or repair it). |
|
2 flashes 1-second pause 2 flashes |
Photocell activation |
The photocellsare being triggered, which is normal if their beam is interrupted while the gate is closing. If the beam was not interrupted, the photocells may be dirty, exposed to bright light, or faulty. |
|
3 flashes 1-second pause 3 flashes |
Motor force limiter activated
|
During movement, the gate detects increased friction—you may need to adjust the gate. Try moving it by hand and readjusting it. Otherwise, it usually helps to increase the motor force. |
|
4 flashes 1-second pause 4 flashes |
STOP input activated
|
A command was sent to the STOP input, so if this behavior was unexpected, check the devices connected to it. |
|
5 flashes 1-second pause 5 flashes |
Internal control unit error |
Wait 30 seconds and try again. If the problem persists, try resetting the reset. Otherwise, the control unit will probably need to be repaired or replaced. |
|
6 flashes 1-second pause 6 flashes |
The hourly operation limit has been reached. |
Wait a few minutes for the cycle limiter value to drop below the limit. |
|
7 flashes 1-second pause 7 flashes |
Internal electronic circuit error. |
Disconnect the entire drive for a few seconds, then try again. If the problem persists, try resetting the reset. Otherwise, the control unit will probably need to be repaired or replaced. |
|
8 flashes 1-second pause 8 flashes |
Continuous command active.
|
A command is being continuously sent to the drive—check the devices connected to the OPEN input. If you have a timer connected, it is probably the cause.
|
Diagnostics using LED flashes
On the SNA4 control unit of the NICE Spinbus SN6041 drive, there are two sets of LEDs, each of which indicates normal control unit operation or diagnoses faults through flashing or steady illumination, as shown in the following tables.
Horizontal BLUEBUS, STOP, PP, OPEN LEDs
|
Indicator |
Status |
Solution |
|---|---|---|
|
BlueBUS LED |
||
|
Off |
Error
|
Check the mains power connection. If it is OK, check fuses F1 and F2 and replace them, if necessary, with new fuses of the same rating. |
|
On |
Serious error
|
Try disconnecting the control unit, and if necessary, all inputs. If that does not help, reset it and if that still does not help, the control unit will probably need to be replaced. |
|
Flashing at one-second intervals |
Everything is OK |
The control unit is operating normally. |
|
2 quick flashes |
Input status changed |
Normal operation—the status of the STEP-BY-STEP input has changed STEP-BY-STEP, STOP, OPEN, have been activated photocells, or the drive received a command from the remote control. |
|
Series of flashes separated by a one-second pause |
More options |
The number of flashes in a series corresponds to error diagnostics by means of the warning light. |
|
STOP LED (Stop) |
||
|
Off |
The STOP input has been activated |
Check the devices connected to the STOP input. |
|
On |
Everything is OK |
The STOP input is not active. |
|
STEP-BY-STEP LED (also labelled P.P., Step-by-step) |
||
|
Off |
Everything is OK |
STEP-BY-STEP input is not active. |
|
On |
The STEP-BY-STEP input has been activated |
Normal operation of the control unit if an active device was connected to the STEP-BY-STEP input. |
|
OPEN LED (Open) |
||
|
Off |
Everything is OK |
The OPEN input is not active.
|
|
On |
The OPEN input has been activated |
Normal operation of the control unit if an active device was connected to the OPEN input. |
Vertical LEDs L1–L4
|
Indicator |
Solution |
|---|---|
|
LED 1 |
|
|
Off |
During normal operation, indicates that the Automatic closing function is not enabled. |
|
On |
During normal operation, indicates that the Automatic closing function is enabled. |
|
Flashing |
|
|
LED 2 |
|
|
Off |
During normal operation, indicates that the Close after photocell interruption function is not enabled. |
|
On |
During normal operation, indicates that the Close after photocell interruption function is enabled. |
|
Flashing |
|
|
LED 3 |
|
|
Off |
During normal operation, indicates that the Motor force function is not enabled. |
|
On |
During normal operation, indicates that the Motor force function is enabled. |
|
Flashing |
|
|
LED 4 |
|
|
Off |
During normal operation, indicates that the Standby mode function is not enabled. |
|
On |
During normal operation, indicates that the Standby mode function is enabled. |
|
Flashing |
|
Installing the backup battery on the NICE Spinbus SN6041 drive
NICE PS124 backup battery is not included as standard with the drive, but it can be ordered separately. It is used in the event of a power outage, when it will power the gate drive. The battery is continuously recharged from the mains supply.
Resetting the control unit
1. Press and hold the first and third buttons simultaneously first (Open) a third (Close) button.
2. When all LEDs light up, release.
3. Wait until the control unit resets.
Technical specifications of the NICE SNA4 control unit for the NICE Spinbus SN6041 drive
| Model | NICE SNA4 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Description | Control unit for gear motor NICE Spinbus SN6041 for automatic operation of garage doors in private settings. | ||||||||||
| Backup power supply | can be purchased and installed NICE PS124 backup battery | ||||||||||
| Lighting | No, the bulb is on the operator. | ||||||||||
| Flashing light output |
Depending on the programmed output:
|
||||||||||
| BlueBUS output | one output for 6 BlueBUS devices | ||||||||||
| STOP input | for normally open, normally closed and 8.2KΩ constant-resistance devices | ||||||||||
| STEP-BY-STEP input (P.P., step-by-step) | normally open (closing triggers the “Step-by-step") | ||||||||||
| Radio receiver | without a receiver; “SM” connector for receivers NICE SMXI, NICE OXI etc. | ||||||||||
| Antenna input | 52Ω for RG-58 coaxial cable (or similar) | ||||||||||
| Programming functions | 4 on/off functions (Level I programming) 4 adjustable functions (Level II programming) |
||||||||||
| Self-learning functions |
|
||||||||||
| Operating temperature | -20°C to +50°C | ||||||||||
| Use in saline, acidic and potentially explosive environments | no | ||||||||||
| Protection rating | IP00 |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]