NICE Hyppo 7100 HY7100 - operator for double-leaf folding gates


Product availability: for the question

The product may not be available, contact us for more information.


NICE Hyppo 7100 HY7100 - operator for double-leaf folding gates
NICE-HY7100
for the question
€387.33 excluding VAT
€476.42 including VAT

 pcs
Weight
13 kg

Description of NICE Hyppo 7100 HY7100 - operator for double-leaf folding gates

NICE HYPPO HY7100 – folding gate operator

The NICE HY7100 operator is designed for double-leaf folding gates. Before ordering, check the gate dimensions, weight, and construction.

NICE HYPPO HY7100 is a standalone electromechanical motor with a telescopic arm for a folding gate. The motor operates on 230 V AC and is non-reversible. It requires a separate control unit, power supply, and safety devices. In the event of a power failure, it can be released with a key.

Quick navigation
Choosing an operatorControl unit
Folding gate operationMounting dimensions
Arm installationManual release
AccessoriesWiring
ConnectionsPhotocells
First start-upSettings and remote controls
TroubleshootingMaintenance
SpecificationsPDF manual

When to choose this operator

The HY7100 is designed for a folding-gate configuration with a telescopic arm. Before choosing, check the dimensions and weight of each section, the position of the vertical hinges, resistance to movement, clearance for folding, and how the motor will be mounted.

Length of each folding gate sectionMaximum 1,500 mm per section, according to the installation diagram.
Weight and lengthThe maximum weight is 200 kg, but the permitted weight decreases as the length increases. At a length of 1.5 m, the curve falls below 150 kg.
Duty cycle30%

A length of 1.5 m and a weight of 200 kg are not a permitted combination. The graph’s horizontal axis shows section length in metres and the vertical axis shows weight in kilograms; the area above the curve marked “Ne” is not permitted. This value does not indicate the capacity of the entire passage or the combined weight of all sections. With a solid infill and wind exposure, assess the load on the entire gate. The duty-cycle percentage is not the number of opening cycles per hour.

HYPPO HY7100 and HY7124 – graph of permitted folding-gate section length and weight

How a folding gate works

In the arrangement shown, one motor moves one pair of folding sections. The motor is mounted on the first section of the folding pair; the telescopic arm connects the mechanism to the second section. A gate with two folding halves requires two motors and a suitable shared control unit. Do not confuse the number of sections with the number of motors.

Folding gate layout with HYPPO operators and telescopic arms

In the diagram:

  • 1 – photocell post
  • 2 – photocell
  • 3 – key switch or keypad
  • 4 – control unit
  • 5 – flashing light
  • 6 – antenna
  • 7 – HYPPO motor
  • 8 – power supply
  • 9 – manual release.

The drawing illustrates the assembly principle; select accessories according to the control unit installed.

Standalone motor and control unit

This listing is for a standalone HY7100 motor with telescopic arm. The control unit is not built into the motor. Select the control unit, safety devices, receiver, and remote controls to suit the specific setup. Check availability and included equipment before ordering.

ModelMotor and limit sensingSuitable current control unit
HYPPO HY7100230 V AC; built-in opening and closing limit switches.MC800 / MCA5R30

The following wiring and first start-up instructions apply to the MC800 / MCA5R30. For an existing automation system, always follow the instructions for the control board actually installed. The motor voltage and the control unit’s mains supply are separate circuits.

Earlier compatible control units: For the original A60 or A6, follow the relevant manual. The current MC800 replaces older control units; their wiring and programming must not be confused. For a single motor, we also offer the MC200, which uses a different accessory connection and does not support BlueBUS.

Installing the telescopic operator

Before starting work, disconnect the mains supply and any backup power, and secure the gate sections against unintended movement.

  • Check the strength of both sections and the hinges. The entire folding pair must move smoothly by hand along its full travel, without sticking or excessive play.
  • Install sturdy mechanical stops for the open and closed positions, suitable for the chosen configuration and the control unit’s learning procedure.
  • Assess potential pinch points at the outer and centre hinges, between the folding sections, and around the telescopic arm. The positioning of the safety devices must take the gate’s entire range of movement into account.
  • The motor, arm, cables, and manual release must not strike the frame, wall, or other section. Fasten them to a load-bearing part of the structure.

Folding section dimensions and mounting points

HY7100 and HY7124 – two sections, each up to 1,500 mm, and local mounting dimensions

Both sections shownEach up to 1,500 mm; this dimension is not the permitted length of a single rigid gate leaf.
Dimension at the centre hinge on the motor sideMax. 200 mm, in the position shown in the diagram.
Dimension at the telescopic arm mounting pointMin. 150 mm, in the position shown in the diagram.

The values 200 and 150 mm refer to specific locations in the drawing. They do not indicate the post cross-section or a universal distance from the motor to the edge. During installation, follow the geometry shown for the telescopic arm and folding sections.

Mounting plate and telescopic arm

  1. Determine whether installation is on the left or right when viewed from the inside. Check the full range of movement of both sections before fastening.
  2. Position the motor mounting plate A and front bracket B as shown in the folding-gate drawing. Here, A/B identify the mounting parts, not the dimensions in the articulated-arm table.
  3. Bolt the motor to the mounting plate. To accommodate left- or right-hand installation, the plate can be rotated 180° as shown in the installation illustration.
  4. Assemble the telescopic arm with the washers and fasteners as shown in the drawing. Lubricate the screws before assembly as instructed.
  5. With the motor released, manually test the full range of movement. Correct minor alignment deviations using the slotted holes, then fully tighten the fasteners.

HY7100 and HY7124 – mounting plate A and front fixing B for a folding gate

HYPPO – adapting the mounting plate for left- or right-hand installation

HYPPO HY7100 and HY7124 – assembling the telescopic arm

Cover and cables

The cable run to the motor on the moving section must remain protected even when the gate is fully folded. Allow sufficient cable slack and strain relief; the cable must not catch on a hinge or arm. After completing the adjustments, secure the cover and handle and check the cable glands.

HYPPO – fitting the cover and release handle

Manual release

  1. Stop the automation, disconnect the power supply and secure the folding sections against unintended movement.
  2. Slide the lock cover upwards, insert the key and turn it clockwise.
  3. Turn the handle as shown, then move the gate manually. Keep your hands clear of the hinges and the gap between the folding sections.
  4. Before automatic operation, return the handle to the vertical locked position, check that the gear is engaged, remove the key and close the lock cover.

HYPPO – releasing the drive with the key and by turning the handle

If there is no alternative entrance, arrange for external release during installation. NICE KIO with KA1 cable choose according to the specific installation; test the complete assembly before handover.

HYPPO – cable-operated release principle

Accessories for the selected control unit

The motor alone does not replace the control unit or safety devices. The positioning of photocells and safety edges must also account for the folding sections and the space between them.

ComponentSelectionWhat to look out for
Control unitMC800Separate control for one or two motors; select according to voltage and position sensing.
PhotocellsEPMB, EPM with MC800BlueBUS is polarity-free; use relay-type EPM only with a control-unit wiring configuration it supports.
Flashing lightELAC230 V AC FLASH with MC800; low-voltage ELDC is not suitable here.
Receiver and transmittersOXIBD, MYGO4SM plug-in receiver; the transmitter must match the receiver’s coding.
Key switchEKSVolt-free C–NO contact to the command input; do not apply an external voltage.
Electric lockPLA10, PLA11For a suitable locking mechanism; ELS output 12 V AC, max. 15 VA.
External releaseKIO + KA1Access to the manual release in the event of a power failure.

Wiring and electrical connection

Route and protect mains cables, motor wires and low-voltage signal cables according to the voltage and environment. The supply to the control unit comprises L, N and PE; protect it with suitable overcurrent protection and a device for complete disconnection. Secure the cables with cable glands and strain relief.

CircuitCableApplication
Supply to control unit3 × 1.5 mm²Up to 30 m; L, N and PE. For a longer supply cable, use 3 × 2.5 mm² and protective earthing for the automation system as specified in the control unit manual.
Motor4 × 1.5 mm²Up to 10 m; open, common, close and protective PE.
BlueBUS2 × 0.5 mm²Up to 20 m; for distances over 20 m and up to 40 m, use 2 × 1 mm². Polarity-free.
Flashing light2 × 1.5 mm²Up to 20 m, mains-powered FLASH.
Electric lock2 × 1 mm²Up to 10 m; output 12 V AC / max. 15 VA.
Key switch4 × 0.5 mm²Up to 50 m; alternatively, two 2 × 0.5 mm² cables.
AntennaRG58Up to 20 m; less than 5 m is recommended.

Check the cross-section and routing against the cable lengths and the manual for the installed control unit.

Motor and control unit wiring

The HY7100 has a 230 V AC motor and built-in limit switches. The control unit procedure below applies to the MC800 with an MCA5R30 board and OutSTB. For the MC200 or legacy A60, use its own manual.

Left-hand motorTerminal block Open / Common / Close (open / common / close). PE connects to a separate protective terminal.
Right-hand motorCompared with the left-hand motor, Open and Close. Do not interchange Common and PE.
One folding leafFor the MC800, use M2; leave M1 unused.
Two folding leavesM2 opens first, and M1 closes first.

HY7100 – terminal block for the left-hand 230 V motor, Open, Common, Close and PE

1 is the cable gland, 2 motor terminal block, 3 protective earth. The AC motor circuit has no DC +/− polarity. Torque is adjusted at the control unit.

MC800 – accessory terminals and polarity

3 / 4 – power supply3 = 0 V (−), 4 = Common +24 V DC (+), combined maximum 200 mA for auxiliary devices.
5 / 3 – OutSTB5 = +24 V, 3 = −; switched supply for relay photocells, max. 4 W. It switches off in Standby. Do not confuse it with OGI on the older board.
6 / 7 – BlueBUSPower and data over two wires; no +/− polarity.
1 / 2 – ELSElectric lock 12 V AC, max. 15 VA; no DC polarity.
FLASHSelf-flashing beacon 230 V AC, max. 21 W; for example, ELAC. Do not connect the low-voltage ELDC here.
4 / 13 – SbSVolt-free NO contact between Common 4 and SbS 13 for step-by-step operation; the contact is not polarised.
4 / 14 and 4 / 15Volt-free NO contact for opening (14) or closing (15).
4 / 12 – STOPLearned safety input: NO, NC or 8.2 kΩ; contacts are not polarised.
8–11 – AUXLimit switches: 8 FCA1, 9 FCA2, 10 FCC1, 11 FCC2; LP off. Relay photocells: 8 PHOTO, 9 PHOTO1, 10 PHOTO2; 11 changes to STOP; LP on. These AUX functions are mutually exclusive. Unused AUX inputs should be left unconnected.

MC800 MCA5R30 – motor wiring and accessory connection options

The diagram shows combined relay and BlueBUS wiring with Standby enabled. Power the relay TX/RX units from OutSTB as shown; for a different mode, use the relevant control unit diagram. The HY7100 microswitches are built into the motor circuit. Do not route volt-free contacts to AUX from the Open/Common/Close terminal block. AUX configuration.

Adjusting the HY7100 limit switches

  1. Disconnect the power, release the motor and manually move the leaf to the closed position against the mechanical stop.
  2. Turn the relevant cam until you hear the microswitch click. Set the other cam with the leaf open to suit the opposite direction.
  3. Return the handle to the upright, locked position.
  4. During a controlled test, check the direction of travel, stopping and seating against the stops. Disconnect the power again before making any further adjustments to the cams.
  5. Disconnect the power again after testing. Only then tighten the cam fixing screws and fit the cover.

HY7100 – opening and closing cams and microswitches

Mechanical stops are still required. Adjusting the cams in the motor is a separate operation from teaching the travel limits on the MC800.

Photocells and safety inputs

Position the photocells according to the movement of the folding leaves and the gate’s hazards. Align the TX/RX units correctly. Passage protection does not replace protection against crushing at the hinges and arms.

The MC800 supports both BlueBUS and relay photocells, including their combined use, according to the correct diagram. The AUX mode and TX/RX power supply must match the wiring and the Standby or photocell-test setting. BlueBUS EPMB, EPLB, EPSB, EPMORB, EPMOB and F210B have two wires with no polarity. The TX and RX units in one pair must have the same jumper settings; the other pair must use a different address. The PHOTO 3 address is not permitted on the MC800.

Relay EPM, EPMOR or EPMA require AUX to be configured for photocells with illuminated LP. RX contact C–NC connects between Common 4 and 8 PHOTO / 9 PHOTO1 / 10 PHOTO2. Connect the TX/RX power supply and test wiring according to the mode, including polarity 3− / 4+ and OutSTB 5+. For EPM, both TX and RX have terminal 1 = + and 2 = − for DC power; RX has 4 = COM and 5 = NC. These numbers do not automatically apply to a different photocell model. Connecting the contact without power and configuration is not enough. Relay photocell procedure.

With an MC800 setup, sensitive safety edges are required. Choose their type and position so that the system passes the impact test under all operating conditions. Connecting an edge to the STOP safety input.

Test each pair during both opening and closing, STOP, and all installed sensitive edges. Do not bypass a safety device to make the gate move.

Initial start-up and learning

Carry out these steps after the mechanical and electrical checks. Engage the motor in automatic mode and check the stops, clear travel path, and M1/M2. Be ready to stop the gate during its first movement.

Set the HY7100 limit switches. Before learning, check that the force setting on the MC800 is suitable, parameter level II/L6. The HY7100 is electromechanical; the pressure-holding function for hydraulic motors must not be activated for it.

After switching on the power, BlueBUS should flash approximately once per second, the LEDs on connected BlueBUS TX/RX photocells must flash, and the FLASH beacon must be off. If any check fails, disconnect the power supply and any backup supply, then check the wiring before continuing.

1. Device recognition

  1. Press and hold Open ▲ + Stop/Set.
  2. Release both buttons when L1/L2 start flashing rapidly, after approximately 3 seconds.
  3. Wait for the process to finish. Success: STOP is lit, L1/L2 are off. L3/L4 may flash to indicate that position learning is required.

Repeat after adding or removing a BlueBUS/STOP device. Perform learning even when no accessories are connected.

MC800 – buttons and LEDs during device learning

2. Automatic position learning

  1. Press and hold Stop/Set + Close ▼.
  2. Release the buttons when L3/L4 start flashing rapidly, after approximately 3 seconds.
  3. Watch for the following: M1 closes, M2 closes, M2 opens, M1 opens, then M1 and M2 close; each moves to its respective stop. With one motor, only M2 moves.
  4. Successful completion is indicated when L3/L4.

If either motor opens instead of closing during the initial closing movements, stop learning by pressing Open ▲ or Close ▼. Disconnect the power supply and any backup supply, then correct the direction of the relevant motor by swapping Open and Close; Common and the protective PE remain on their respective terminals. With two motors, correct M1/M2 if their sequence is wrong. Start the learning process again from the beginning. Activation of a photocell or STOP interrupts the process and L1 flashes; resolve the cause and repeat learning.

3. Testing and handover

Test full opening and closing cycles, the stops, slowdowns, coordination of the folding leaves, and manual release. Check every safety device, stopping, and reversal after encountering an obstacle. Measure the forces and assess the entire system. Do not set the force too high to compensate for a gate that is sticking. The user must receive the manual and know how to release the drive safely.

Manual and mixed learning: detailed control unit procedure. Automatic learning must be completed before mixed learning.

Settings and remote controls

Set automatic closing, pause time, step-by-step operation, slowdown, and force according to the gate. Repeat the tests after changing the force or safety functions. The full ranges, LEDs, and factory settings are listed in the control unit programming tables.

Receiver, remote control, and antenna

The motor alone does not have a built-in radio receiver. An SM receiver is fitted to the control unit. NICE OXIBD also supports bidirectional ON3EBD; OXILR use with ON3ELR. For the older OXI choose transmitters according to the stored coding. The same frequency alone does not guarantee compatibility.

Connect the coaxial cable according to the receiver: directly to the receiver for OXIBD, and according to the control unit wiring diagram for OXI. Pairing and deleting remote controls. Erasing the radio memory does not reset the board or teach the positions.

What to check when troubleshooting

SymptomWhat to check
The gate does not movePower supply, release mechanism engaged, and STOP. Check the power supply and fuses with the power disconnected.
The motor runs, but the leaf does not moveCheck that the drive is engaged and the arm is secured; return the release mechanism to the locked position.
The gate stops or reversesFirst check manual movement and the arm clearance, then the photocells, STOP, and stops. Do not increase the force without identifying the cause.
Learning does not completeMotor sequence and direction, stops, and safety devices. For the HY7100, also check the limit switch cams.
The remote control does not work, but the button doesBattery, coding, storing the transmitter in the receiver, and the antenna.
Fault after changing the photocellsCheck the addresses and cables, then repeat device recognition.

Flasher and LED flash counts: troubleshooting and repairs. Record the settings before resetting. Resetting the control board, deleting the receiver memory, and performing a new learning procedure are different operations; refer to the manual for the installed control unit.

Inspection and maintenance

Have the entire automation system inspected at least every six months; inspect it more frequently if it is used intensively or operates in harsh conditions, in accordance with the maintenance schedule. Check the end and intermediate hinges, motor mounting, telescopic arm, stops, cable routing, manual release, and all safety devices. Record the results in the maintenance log.

While the gate is moving, do not go between the folding sections or into the arm's path. Do not let children play near the gate, and keep the remote controls out of their reach. Secure the gate against movement before manually releasing it or cleaning accessible surfaces. Repeat the functional and safety tests after repairs, electrical work, or changes to the safety settings. If the gate malfunctions, take it out of service and secure it.

NICE HYPPO HY7100 technical specifications

TypeNon-reversible electromechanical motor with telescopic arm for a folding gate.
Motor voltage230 V AC
Current1.2 A
Power consumption250 W
Torque400 Nm
Rotation speed1.7 rpm
Opening time stated by the manufacturer12 s
Duty cycle30%
Position sensingOpening and closing limit switches
CapacitorBuilt-in, 10 µF
Ingress protection ratingIP43
Operating temperature−20 to +70 °C
Motor weight13 kg
Dimensions350 × 165 × 242 mm; motor body with mounting plate, as shown in the drawing.
Folding section limitsMaximum 1,500 mm; weight according to the graph. The maximum length and weight limits do not apply simultaneously.

The opening time is not guaranteed for every folding gate. It depends on the geometry, control settings, and load. For an older operator, refer to its rating plate and the corresponding manual.

HYPPO – motor and mounting plate dimensions

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Hyppo 7100 HY7100 - operator for double-leaf folding gates

Product: NICE Hyppo 7100 HY7100 - operator for double-leaf folding gates
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.