Simplified procedure for wiring and starting NICE Robus and Run gate operators
If you don’t feel like reading the entire manual for Robus operators, you can get a NICE Robus or Run operator up and running in just a few minutes by following these simplified wiring and startup instructions.
We assume that the sliding gate moves freely along its track and that you have completed the steps for installing the rack, installing the operator, and fitting the end stops to the rack.
In other words, with the operator released, you can move the gate by hand, and the operator’s limit switch is activated in both the open and closed positions.
The simplest approach is to get the operator itself running first, without any accessories, which you can connect later, one at a time. But you can connect the accessories straight away if you like; it doesn’t matter when you do it, and anything can be connected or disconnected at any time. You can always restore the operator to factory settings.
Step 0. Wiring
This is probably a good time to plug in the radio receiver. You can plug it in later too, but in general, only insert or remove it when the power is disconnected.
Power supply cable
Terminal L – live wire from the power supply cable
Terminal N – neutral wire from the power supply cable
Terminal marked with the earth symbol – earth wire from the power supply cable
Warning light
Connect the two-core cable from the warning light, from the terminal marked with the bulb symbol, to the FLASH terminal on the control unit. If you are not installing a warning light, leave the FLASH terminal unconnected.
Antenna
If your control unit has a radio receiver with a terminal, connect the antenna to the receiver. If not, connect the antenna to the control unit. If you don’t have an antenna, connect the wire supplied with the receiver to its first terminal (a temporary antenna).
Photocells
Run a two-core cable from the BUS (BlueBUS) terminal on the control unit to each photocell, or run it from the control unit to the first photocell and then on to the second. Polarity does not matter. Do not break any circuits on the circuit board. More about connecting photocells.
Key switch
Connect terminals NC and C on the first microswitch in the key switch to the STOP input on the control unit.
Connect terminals NO and C on the second microswitch in the key switch to the SbS (or P.P.) input on the control unit.
More about connecting a key switch.
Step 1. How to get the operator running:
- Disconnect the operator from the power supply. The easiest way is to remove the power fuse.
- Move the gate by hand to roughly halfway along its travel (so it is neither open nor closed), engage the operator, then pull the gate slightly so the gearbox engages.
- Set the gate opening direction selector on the control unit. If you are standing inside your property, facing the gate from the inside:
- if the operator is on the left (the gate opens to the left), set the selector to the left as well;
- if the operator is on the right (the gate opens to the right), set the selector to the right.
- Restore power to the operator.
- With the factory settings (or after a reset), the BlueBUS and L1+L2 LEDs on the control unit should be flashing. The AUX IN indicator at the top right should also be lit, if present.
- Run the connected-device setup: press and hold OPEN+STOP/SET (the first and second buttons) at the same time. When the L1+L2 LEDs start flashing faster (after about 3–4 seconds), release the buttons. The L1+L2 LEDs will continue flashing for a short time. The operator will then hum and click, and L3+L4 will start flashing.
- Run the gate travel setup: Press and hold STOP/SET+CLOSE together. When L3+L4 start flashing faster and the gate starts moving, release the buttons. The operator will open the gate and then close it, leaving the gate closed. L3+L4 will go out.
- You should now be able to operate the gate using the OPEN, STOP/SET, and CLOSE buttons. OPEN opens the gate, CLOSE closes it, and STOP/SET stops it.
- Congratulations—you’ve got your NICE Robus or Run sliding gate operator up and running!
If you haven’t already, you can connect the photocells, warning light, key switch, or other accessories, plug in the receiver, and pair the remote controls.