Wiring a key switch to NICE Robus and Run sliding gate operators
The key switch has two positions. You can turn the key either right or left; a spring inside the switch returns the key to the center. The switch contains two microswitches, each with three terminals: NC, C and NO. You can wire just one side of the key switch, both sides, or leave it unwired altogether. It does not affect the operator's functionality; it is an optional accessory. You can wire each side of the key switch to either the STOP, SbS (Step by Step, step-by-step operation; formerly P.P., Italian passo-passo, meaning step by step), OPEN or CLOSE terminal.
Possible wiring configurations and functions:
- STOP input is wired to the microswitch in the key switch at terminals NC and C. Turning the key in this direction only stops (halts) the gate.
- SbS (P.P.) input is wired to the microswitch at terminals NO and C. Repeatedly turning the key in this direction makes the gate open, close and stop, depending on how it is programmed. The factory setting is as follows: with the gate closed, turning the key once starts opening it; turning it again stops it; turning it once more starts closing it; and the next turn does not stop it but immediately starts opening it again. If the gate opens fully, turning the key closes it. This behavior is the same as repeatedly pressing the remote control.
- OPEN input It is wired and works just like SbS, except that it only opens the gate, stops it, and opens it again. Once the gate is open, it stops responding.
- CLOSE input is the opposite of the OPEN input, so it only closes the gate, stops it, and closes it again. When the gate is closed, it does not respond. This input can be reprogrammed for partial opening (pedestrian access) in the settings.
Key switch wiring summary
The original manual shows wiring to the STOP and SbS terminals: run a two-core cable from terminals NC and C on one microswitch to the STOP input on the control unit, and from terminals NO and C on the other microswitch to the SbS input on the control unit. This way, turning the key one way opens, closes or stops the gate, while turning it the other way only stops it. You can, however, wire the key switch in any way you like.
Remember to disconnect the operator from the power supply before making any wiring changes. After changing the wiring and restoring power, run a device check by holding down the OPEN+STOP/SET buttons until the L1+L2 LEDs start flashing, then release them.