Connecting photocells to a NICE Robus or Run gate opener
Robus/Run operators use BlueBUS technology, so they are compatible only with photocells that support this technology.
Photocells always come in pairs: a transmitter (TX) and a receiver (RX). There are three types of photocell setups:
- Both photocells wired (transmitter TX and receiver RX). The most commonly used models are EPMB and EPSB, followed by EPLB and F210B, and the older, discontinued MOFB.
- One wired photocell and one battery-powered wireless photocell. The most commonly used models are EPMB and EPSB, followed by EPLB and F210B, and the older, discontinued MOFB.
- Both photocells wireless. EPMOW model paired with an IBW device.
Before connecting the photocells, disconnect the operator from the power supply. Once connected, restore power and detect the connected devices by holding the OPEN+STOP/SET buttons until LEDs L1+L2 start flashing, then release them.
The entire BlueBUS system is connected using two-core cables; the cable should be 2x0.5 mm2. If you use network cables (FTP, UTP, STP, or any other twisted pair) for the connection, the cross-sectional area of a single conductor is usually between 0.10 and 0.25 mm2. We therefore recommend doubling the wiring: instead of using two conductors, use four—two pairs. Otherwise, the cable may pass a continuity test and the photocell may flash, but still malfunction.
Wiring wired photocells
Connect the photocells in parallel to the BlueBUS input using two-core cables; polarity does not matter. You can connect both photocells directly to the control unit, or run a two-core cable from the control unit to one photocell and then another two-core cable from there to the next.
| Connecting both photocells to the control unit | Connecting from the control unit to one photocell and then to the other |
|---|---|
![]() |
![]() |
Connecting one wired and one wireless photocell
This setup uses only NICE FT210B photocells. Connect one photocell to the BUS (BlueBUS) terminal on the control unit using a two-core cable from the BlueBUS terminal; the other is battery-powered.
Connecting wireless photocells
The truth is, wireless photocells are not wired because they are wireless. Only the IBW communicator is connected; the photocells communicate with it wirelessly. For connection instructions, go to Connecting and programming the NICE IBW device with NICE EPMOW photocells.