Simplified procedure for wiring and commissioning the NICE Robus RBS gate operator
If you don’t want to read the entire manual for Robus RBS operators, you can get it up and running in just a few minutes using this simplified wiring and setup procedure.
We’ll assume your sliding gate moves smoothly back and forth and that you’ve completed the steps for installing the rack, mounting the operator, and fitting the end stops to the rack.
In other words, when the operator is released, the gate can be moved by hand, and the operator’s limit switch is activated in both the fully closed and fully open positions.
The easiest way is to get the operator itself running first, without any accessories, which you can connect one by one later. You can also connect the accessories right away if you like; it doesn’t matter when you do it, as anything can be connected or disconnected at any time. You can always restore the operator to factory settings.
Step 0. Wiring
This is probably a good time to plug in the radio receiver. You can plug it in later, too, but in principle you should only insert or remove it when the power is disconnected.
Power supply cable
Terminal L – live wire from the power supply cable
Terminal N – neutral wire from the power supply cable
Terminal with the earth symbol – earth wire from the power supply cable
Warning light
Connect the two-core cable from the warning light’s bulb-symbol terminal to the FLASH terminal on the control unit. If you’re not installing a warning light, leave the FLASH terminal unused.
Antenna
If your control unit has a radio receiver with a terminal, connect the antenna to it. If not, connect the antenna to the control unit. If you don’t have an antenna, connect the supplied wire (a temporary antenna) to the first terminal on the receiver.
Photoelectric safety sensors
Run a two-core cable from the BUS (BlueBUS) terminal on the control unit to each photocell, or connect the control unit to the first photocell and then run a cable from there to the second. Polarity doesn’t matter. Do not break any circuits on the circuit board. More about connecting photocells.
Key switch
Connect terminals NC and C on the first microswitch in the key switch to the STOP input on the control unit.
Connect terminals NO and C on the second microswitch in the key switch to the SbS (or P.P.) input on the control unit.
More about connecting a key switch.
Step 1. How to get the operator running:
- Disconnect the operator from the power supply. The easiest way is to remove the power fuse.
- Move the gate by hand to approximately halfway along its travel (so it is neither open nor closed), engage the operator, and pull the gate leaf slightly to engage the gearbox.
- Set the gate opening direction selector on the control unit. If you’re standing inside the property, looking at the gate from the inside:
- if the operator is on the left (the gate opens to the left), set the selector to the left as well;
- if the operator is on the right (the gate opens to the right), set the selector to the right.
- Reconnect the operator to the power supply.
- With the factory settings (or after a reset), the BlueBUS and L1+L2 LEDs on the control unit should be flashing. The AUX IN indicator at the upper right should also be lit, if present.
- Run the connected-device recognition procedure: press and hold the OPEN and STOP/SET buttons at the same time (the first and second buttons). When the L1+L2 LEDs start flashing faster (after about 3–4 seconds), release the buttons. The L1+L2 LEDs will continue flashing for a while, then the operator will hum and click, and L3+L4 will start flashing. The operator will then hum and click, and L3+L4 will start flashing.
- Run the gate travel recognition procedure: Press and hold STOP/SET and CLOSE together. When L3+L4 start flashing faster and the gate begins to move, release the buttons. The operator will open the gate and then close it, leaving it in the closed position. L3+L4 will go out.
- You should now be able to open and close the gate using the OPEN, STOP/SET, and CLOSE buttons. The OPEN button opens the gate, the CLOSE button closes it, and the STOP/SET button stops it.
- Congratulations—you’ve got your NICE Robus RBS sliding gate operator up and running!
If you haven’t already, you can connect the photocells, warning light, key switch, or other accessories, plug in the receiver, and pair the remote controls.