NICE Wingo WG3524 HS High-Speed Operator
NEW| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€297.34 including VAT
| Weight |
|---|
| 7,50 kg |
Description of NICE Wingo WG3524 HS High-Speed Operator
NICE WINGO WG3524HS is a fast, standalone electromechanical operator for one leaf of a residential gate. It is part of the Hi-Speed operator range and features a 24 V DC motor with a magnetic encoder. With standard installation, it opens to 90° in approximately 10 seconds, excluding acceleration and deceleration time. It is non-reversible; in the event of a power failure, it can be released with a key. The control unit and safety accessories are selected separately.
When to choose the WINGO WG3524HS
Choose based on the length and weight of one gate leaf, the number of cycles, hinge resistance, infill, and wind exposure. The gate must move smoothly by hand along its entire travel and must not move on its own after it has stopped.
| Length of one leaf | Up to 3 m, with weight according to the graph. |
|---|---|
| Weight of one leaf | Up to 200 kg for a short leaf; at 3 m, the limit is approximately 100 kg. |
| Duty cycle | Up to 30 cycles/hour at rated force; one cycle consists of opening and closing. |
| Number of motors | One motor per leaf, two motors for a double-leaf gate. |
The horizontal axis shows length in metres, and the vertical axis shows weight in kilograms. The grey area indicates the permitted range. Point A is an example of a suitable combination; point B is outside the permitted range. A solid leaf and wind can limit suitability even when the dimensions are within the specified limits.
Control unit for a 24 V motor
This operator is designed for the NICE MC824HR30 / MCA1R30 MC824H type, which supports a magnetic encoder. The control unit is powered by 230 V AC, while the motor is supplied with 24 V DC. Do not connect the motor directly to the mains. The MC824L is designed for other motors and cannot be used as a direct replacement.
The following wiring and setup instructions apply to the MC824HR30 with 12 Motor Type switches. If retaining an older control unit, follow the markings on its circuit board. Full settings are provided in the MC824HR30 combined manual.
What the standalone operator includes
Standalone motor with release keys, front and rear brackets, mounting plate, fasteners, and a pre-installed mechanical opening stop. Anchors for the specific substrate must be selected according to the material of the post or wall.
The control unit, receiver, remote controls, photocells, and warning light are not included with the standalone motor. The gate assembly needs mechanically defined open and closed positions; when opening, you can use an adjustable stop in the operator. Choose a kit for a complete setup.
Kits for one or two leaves
The kits listed include MC824HR30, OXIBD receiver and MYGO4 remote control. The version with photocells also includes a pair of EPMB; the accessory version also includes the ELDC warning light. The number of motors matches the number of leaves.
| Gate | Kit |
|---|---|
| 1 leaf | Basic |
| 1 leaf | With accessories |
| 1 leaf | With photocells |
| 2 leaves | Basic |
| 2 leaves | With accessories |
| 2 leaves | With photocells |
I. Installing the rear bracket
Disconnect the mains supply and any backup battery before starting work. Check that the gate leaf, hinges, and fixing points are secure. The cover and manual release must remain accessible throughout the product's service life.
A: motors; B: photocells; C: opening stops; D: photocell posts; E: warning light; F: control device; G: control unit. Determine the number and position of safety devices for the specific gate.
- Measure C, the offset of the hinge axis from the mounting surface, as shown in the diagram.
- Find C on the chart and read horizontally to determine B. At the recommended mounting line r.i.l., read off the achievable angle.
- From the selected point, read vertically to determine A. A and B should be similar, ideally equal. Dimensions must remain within the chart’s permitted area.
- Check clearance for the motor’s full travel and the position of the front bracket on the fixed part of the gate leaf.
The supplied rear bracket is 150 mm long. Cut it to size according to the geometry and weld it to the mounting plate; secure the plate with suitable anchors. If you need a greater offset, choose the NICE PLA6 extended rear bracket. The dimensions shown in the chart must still be observed after replacing it.
Outward opening
For outward opening, use the geometry shown in the following diagram and the extended rear bracket PLA6. Check clearance outside the passage, the correct direction of both motors, and position learning. The standard dimensions for inward opening do not apply to this installation.
II. Front bracket and dimensions
For the WG3524HS, the installation dimension is D = 850 mm and the relationship E = D − A. D is not the piston rod stroke. Weld the front bracket to the fixed part of the gate leaf; for bolted installation, use the NICE PLA8.
| A (mm) | E (mm) |
|---|---|
| 100 | 750 |
| 110 | 740 |
| 120 | 730 |
| 130 | 720 |
| 140 | 710 |
| 150 | 700 |
| 160 | 690 |
| 170 | 680 |
| 180 | 670 |
| 190 | 660 |
| 200 | 650 |
| 210 | 640 |
| 220 | 630 |
| 230 | 620 |
| 240 | 610 |
| 250 | 600 |
| 260 | 590 |
| 270 | 580 |
| 280 | 570 |
The front mounting point on the gate leaf is F = 30 mm lower than the rear mounting point. The motor must be horizontal; check its position with a spirit level before permanently securing the brackets.
- Attach the motor to the rear bracket using the supplied bolt, washer and nut. Tighten the nut, then loosen it by approximately 1/10 turn, leaving the minimum clearance required.
- Connect the front end to the bracket using the supplied parts, as shown in the diagram.
- With the motor released, manually test the gate leaf through its full travel. It must not bind or strike the post.
III. Mechanical stops
The pre-installed adjustable stop in the drive sets the open position and can replace a separate gate opening stop. Provide a fixed mechanical gate stop for the closed position. Both ends of travel must be reliably limited; do not rely on the piston rod reaching the end of its stroke when closing.
- With the power disconnected, release the drive and loosen the stop screw.
- Manually open the gate leaf to the desired position.
- Move the stop up to the pin and tighten it. Observe the dimension 90 mm max. in the detail view. This is not the motor’s total stroke, which is 470 mm.
- Manually close the gate leaf, secure the motor, and only then perform position learning.
Manual release in the event of a power failure
- Stop the gate, disconnect the power supply, and secure the leaf against moving on its own. If it has an electric lock, unlock it first.
- Slide the lock cover aside, insert the key, and turn it clockwise.
- Lift the handle and guide its movement. The leaf can now be moved manually.
- To restore normal operation, lower the handle, turn the key counterclockwise, remove it, and close the cover. Check that it is secured before operating the motor again.
If the gate is the only entrance to the property, plan access to the release mechanism during installation.
Wiring with MC824HR30
Keep the mains cable separate from the signal cables. Protect cables from water and movement, secure them in cable glands, and leave sufficient slack. The power supply must have suitable overcurrent protection and a means of complete disconnection.
| Circuit | Cable | Maximum length |
|---|---|---|
| 230 V supply to the control unit | 3 × 1.5 mm² | 30 m |
| Each motor + encoder | 3 × 1.5 mm² + 2 × 1 mm² or 5 × 1.5 mm² | 10 m |
| BlueBUS | 2 × 0.5 mm² | 20 m; over 20 m up to 40 m: 2 × 1 mm² |
| Flashing light | 2 × 0.5 mm² | 20 m |
| Key switch | 2 cables, 2 × 0.5 mm² each | 50 m |
| Electric lock | 2 × 1 mm² | 10 m |
| Antenna | RG58 | 20 m; less than 5 m recommended |
For details, including a longer mains supply cable, see the MC824HR30 wiring. Check the wire colors for the specific motor; do not connect the encoder wires to the motor output.
Connections, polarity, and photocells
| M1/M2 and ENC1/ENC2 | Each motor has its own motor and encoder connector. M2 opens first; M1 closes first. Connect a single motor to M2/ENC2. |
|---|---|
| Auxiliary power supply | The left contact in the SbS pair is + (positive), the right contact in the STOP pair is − (negative). 24 V DC −30/+50%, maximum 200 mA. |
| BlueBUS | Two-wire photocell connection, non-polarized. Each pair must have the correct address for its function. |
| STOP | Learned safety input for NO, NC, or 8.2 kΩ; select the wiring according to the device. |
| SbS / OPEN / CLOSE | Voltage-free NO commands. Do not connect an external voltage source to the control inputs. |
| FLASH | 12 V DC / 21 W, suitable for ELDC. Check the +/− markings on the specific output and flashing light. |
| ELS / OGI | ELS is 12 V AC / 15 VA, with no +/− polarity. OGI 24 V / 4 W is a programmable output; wire it according to the selected function. |
The positive and negative positions refer to the auxiliary power supply on the specified contacts; they are not instructions for bridging inputs. BlueBUS, the encoder, and voltage-free contacts do not use this +/− arrangement.
For the current setup, use, for example, EPMB photocells. Other options include EPSB, EPLB and F210B. Wireless EPMOW require an interface IBW. Wiring and addresses are covered in the BlueBUS section.
Initial setup with MC824HR30
1. Selecting the correct motor
With the power disconnected, set the following for WG3524HS: Motor Type: DIP 8 ON, all other DIP switches 1–7 and 9–12 OFF. This is not the L1–L8 function setting.
2. Device recognition
- Check the motor/encoder connectors, travel stops, and safety device operation. Switch on the power.
- Press and hold Open + Stop/Set. When L1 and L2 start flashing rapidly after about 3 seconds, release the buttons.
- Wait for the process to finish. The STOP LED must be lit and L1/L2 must be off. Repeat the learning procedure after changing a safety device.
3. Automatic position learning
- Press and hold Stop/Set + Close, until L3/L4 start flashing rapidly after about 5 seconds. Release the buttons.
- Watch the entire cycle: slow closing of M1, then M2, slow opening of M2 and M1, and finally fast closing of both leaves.
- If the direction or sequence is incorrect, stop the learning procedure using the Open or Close button and disconnect the power supply. Correct the motor direction; if the sequence is reversed, swap both the motor connectors and the corresponding encoder connectors. A single motor remains connected to M2/ENC2.
- When the procedure is completed correctly, L3/L4 go out. If PHOTO/STOP is triggered and L1 lights up, remove the cause and repeat the learning procedure.
Manual and mixed learning, slowdown positions, and precise adjustments are covered in the MC824HR30 position setup guide. Before handing over the system, carry out complete tests—not just one successful cycle.
Settings and remote controls
Set automatic closing, pause time, speed, force, and other functions according to the MC824HR30 programming guide. Do not increase the force to compensate for a gate that is difficult to move. Repeat the safety tests after making changes.
The control unit requires a radio receiver. Current kits include OXIBD and MYGO4. For two-way communication with OXIBD, ON3EBD. You can also keep OXI with compatible remote controls; OXILR requires remote controls from the ONE LR.
Other available options include INTI2, ON2E, FLO2RE and NICEWAY; choose according to the receiver and its code family. Frequency alone does not guarantee compatibility. Pair the devices according to the receiver and antenna instructions.
For OXIBD, connect the external antenna directly to the receiver’s antenna terminals. Follow the markings for the coaxial cable’s centre conductor and shielding; these are not +/− power terminals.
Adding accessories
| Warning light | ELDC for the corresponding DC output. WLT must only be connected to a voltage and function supported by its instructions; do not connect it directly to 230 V. |
|---|---|
| Photocells | EPMB and other compatible BlueBUS devices. |
| Brackets | PLA6 for the required extension of the rear mounting point; PLA8 for screw-mounted front fixing. |
| Service interface | IBT4N and OVIEW for professional setup and diagnostics. |
Operation during a power outage
The MC824HR30 supports the NICE PSS324 backup battery. The older PS324 is connected via CABLA11 and the Standby function must be disabled when using it. When choosing a replacement, always specify the exact model of both the control unit and the battery.
Make connections with both the mains supply and the battery disconnected. Runtime depends on the battery’s condition and the gate load. For details, see the MC824HR30 backup power guide; without a battery, manual release.
If the gate does not work properly
| Symptom | What to check |
|---|---|
| Motor does not move | Check the control unit’s power supply, that the release is secured, the STOP circuit, and the photocells. If it has stopped due to overload, let it cool down and remove the cause. |
| Leaves move in the wrong sequence | M2/ENC2 opens first, M1/ENC1 closes first; inspect and adjust only with the power disconnected. |
| Stops or reverses | Check for obstructions, wind, hinge resistance, photocells, stops, and the encoder connection. |
| L1/L2 or L3/L4 are flashing | Device or position learning is not yet complete; follow the instructions for the relevant stage. |
| Warning light indicates a fault | MC824HR30 diagnostic table explains the number of flashes and the corresponding response. |
Resetting is not the first step for a routine fault. Clearing the settings requires repeating the learning procedure and checking safety; radio remote controls are managed separately in the receiver.
Estimated service life
Add the relevant indices within the permitted gate dimensions. Include other factors if they occur with a probability of more than 10%. The graph shows the approximate number of cycles with regular maintenance; it is not a guarantee or a number of years.
| Characteristics of the complete automation system | Index | Service life graph |
|---|---|---|
| Gate leaf over 100 kg and up to 200 kg | 10% | |
| Length 1–2 m | 10 % | |
| Length over 2 m up to 3 m | 20 % | |
| Above 40 °C / below 0 °C or humidity above 80 % | 20 % | |
| Solid gate leaf infill | 15 % | |
| Windy conditions | 15 % |
When selecting, you must still stay within the permissible length and weight chart. The service-life index does not allow for a heavier or longer gate leaf.
Testing, safety and maintenance
Check the entire travel path, stops, manual release, photocells, STOP function and impact forces. During the manual test described in the motor manual, 390 N is the upper test limit for manual movement, not a target impact-force setting. Hand over the manual and demonstrate how to release the drive safely.
Carry out an inspection at least every 6 months, more frequently in intensive use. Check the brackets, screws, corrosion, hinges, condition and lubrication of the worm screw as instructed in the manual, cables, stops and all safety devices. Disconnect the power supply and battery before maintenance.
Do not enter the gate leaves’ path while they are moving. Keep controls out of children’s reach and do not operate the gate without a clear view of the passage. If the gate leaf has a pedestrian gate, opening it must prevent the drive from starting. In the event of a fault, take the automatic system out of service and call a service technician; do not bypass safety devices.
WG3524HS technical specifications
| Model | NICE WINGO WG3524HS |
|---|---|
| Motor | 24 V DC; not a direct 230 V supply |
| Force | Max. 1 500 N, rated 650 N |
| Speed | 0.040 m/s unloaded; approximately 10 s / 90° without acceleration or deceleration under standard installation conditions |
| Power consumption / current | Max. 120 W / 5 A; rated 72 W / 3 A |
| Cycle rate | Up to 30 cycles/h at rated force |
| Stroke | 470 mm |
| Ingress protection rating | IP44 |
| Operating temperature | −20 to +50 °C |
| Dimensions | 920 × 98 × 95 mm |
| Weight | 6 kg |
We can help you choose based on the dimensions, weight, infill, usage frequency and hinge position. Contact us with these details and a photo of the installation location.
Installation manual PDF
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]

















