NICE Hyke HK7024 HS Fast Operator
NEW| Product availability: | within 7 days | We usually dispatch goods within 7 days. |
|---|
within 7 days
€845.72 including VAT
| Weight |
|---|
| 13 kg |
Description of NICE Hyke HK7024 HS Fast Operator
NICE HYKE HK7024HS is a fast articulated non-reversible drive for one leaf of a swing gate. It has a built-in control unit; for a double-leaf gate, it is paired with HK7224HS.
The motor runs on 24 V DC. The 230 V AC mains supply is connected to the integrated HK7024HS control unit, not directly to the second motor. The articulated arm can also be installed where the hinge is set back on a wider support, provided the position and clearance comply with the installation diagram. With a standard installation, opening to 90° takes approximately 10 s.
| Quick navigation | |
|---|---|
| Choosing a drive | Accessories |
| Installation | Arm and stops |
| Wiring | Terminals |
| Initial startup | Programming |
| Diagnostics | Reset |
| Maintenance | Service life |
| Specifications | PDF manual |
Choosing a drive and leaf limits
HYKE HS has separate maximum limits for a length of 3 m and a weight of 270 kg. These limits do not apply simultaneously: the allowable combination is determined by the graph. According to the graph, a 3 m leaf can weigh approximately 175 kg, while a 1.8 m leaf can weigh approximately 260 kg. Therefore, a length of 3 m and a weight of 250 kg are not an allowable combination for a single leaf. Solid infill, wind, poor balancing or resistance to movement can lower the limit further.
The graph shows leaf length on the horizontal axis and weight on the vertical axis single leaf.
With the shortened arm, the operating range is smaller than with the full-length arm. Before choosing a drive, check that the gate moves freely, the leaf is sturdy and the arm can be positioned safely. One motor is required per leaf; two motors do not increase the permitted weight of a single leaf.
Control unit and compatible accessories
| What | Why | Type |
|---|---|---|
| Motor and control unit | One motor per leaf. For the second leaf, add HK7224HS. |
|
| Radio receiver | SM connector on the HK7024HS control unit; choose a receiver that matches the transmitter's coding. | |
| Remote control | Pair it with the installed receiver; frequency alone does not determine compatibility. | |
| Photocells | Safety devices on BlueBUS; run device learning after adding them. | |
| Warning light | Indicates movement. The FLASH output is 12 V DC / max. 21 W. | |
| Backup power supply | For the HK7024HS in the event of a mains failure, after checking the control board and connector. |
|
Installation and site check
The support must securely bear the load, and the arm must rotate freely throughout its full travel. Allow at least 210 mm of clearance width for the motor. For the installation shown, the distance from the motor axis to the opposite obstruction must be at least 300 mm; measure the additional 150 mm dimension and hinge offset according to the relevant drawing. These are not universal post dimensions. A hinge offset of up to approximately 400 mm is possible only with geometry matching the drawing and chart. Select the bracket anchors to suit the actual substrate; they are not included with the motor.
Before drilling, measure the hinge axis position, bracket position and required angle. For the full-length arm, use the original A/B dimension chart; secure the leaf bracket to a solid part of the frame. With the full-length arm, the maximum opening angle is 110° according to the installation chart. Repair the gate first if it binds, is deformed or lacks secure mechanical stops.
Full-length and shortened arms, end stops
Measure the clearance dimension E at the obstruction. Use the full-length arm for E of at least 650 mm; for E of 300–650 mm, shorten it according to the installation instructions. The shortened arm limits the permissible angle and the combination of length and weight; for this configuration, follow the chart and do not exceed the planned opening angle. Shorten the arm only at the designated points on the original arm, not by guesswork.
After securing the motor, position the arm and leaf bracket at the farthest solid point, check that the arm engages correctly at the end position, and set the mechanical opening and closing stops. With the motor released, manually move the gate through its full travel; movement must be smooth and free of collisions.
Electrical connections
The integrated control board operates both motors. On a single-leaf gate, connect the motor to M2; leave M1 unused. For a two-leaf gate, M1 operates the leaf that closes first and M2 the second; connect the corresponding encoders to ENC1/ENC2. Disconnect the mains supply and backup power before working. For the second motor, use 3 × 1.5 mm² cable for runs up to 10 m and 2 × 1 mm² encoder cable for runs up to 10 m; the actual route and cross-section must suit the installation.
Accessory power supply and polarity
| Terminals | Connection |
|---|---|
| BlueBUS | Two wires for compatible photocells; no polarity. Repeat the learning procedure after changing devices. |
| SbS (+) and STOP (−) | Auxiliary 24 V DC, maximum 200 mA between the terminals marked this way on the integrated board, as shown in the illustration. Voltage remains present in standby mode. These terminals also serve as command and safety inputs; accessory power must be wired in accordance with the contact connections. |
| STOP, SbS, OPEN, CLOSE | Voltage-free contacts; STOP can be NO, NC or an 8.2 kΩ resistor, depending on the learning procedure. No +/− polarity applies to the contact itself. |
| ENC1 / ENC2 | Encoder for the corresponding motor; refer to the manual no polarity. |
| FLASH | 12 V DC, maximum 21 W; select a warning light to suit the operating mode and current draw. Do not guess the polarity of individual unmarked leads. |
| ELS / OGI | ELS: 12 V AC lock, maximum 15 VA. OGI: 24 V DC indicator, maximum 4 W. The outputs can be assigned different functions through programming. |
Initial startup and position learning
On the HK7024HS board, set the motor type before learning the positions. On the 12-position selector of the board shown, position 12 is ON for HYKE HS; all other positions are OFF. If your board has different markings or a different version, set it according to the board actually installed.
- Check that the wiring is correct, the mechanical stops are set and there is sufficient clearance. Before applying power, move the leaf to approximately halfway along its travel.
- After switching on, BlueBUS should flash approximately once per second; the photocell LEDs should respond and FLASH should remain off.
- Press Open and Stop/Set simultaneously for approximately 3 s, until L1 and L2 start flashing rapidly. After learning, STOP must be lit and L1/L2 must be off.
- Check the HS motor selection. Press Stop/Set + Close for approximately 5 s, until L3/L4 flash rapidly. The control unit slowly closes M1, then M2, opens both, and then closes them quickly. With one motor, M1 is skipped.
- If the wrong leaf moves first or moves in the wrong direction, stop the learning procedure; with the power disconnected, correct the motor and corresponding encoder connections, then repeat the procedure. Activation of a photocell or STOP interrupts the learning procedure.
- Check the direction, slow-down, stops and all safety devices over several complete cycles. The leaf must move freely even when manually released.
Programming on the integrated control board
First level: Hold Stop/Set until L1 starts flashing, then release the button; use Open/Close to select the LED, and Stop/Set to toggle its state (rapid flashing = OFF, slow flashing = ON). When finished, wait 10 s. Do not leave more than 20 s between button presses.
| LED – function | ON / OFF state |
|---|---|
| L1 – Automatic closing | Closes after the pause time; OFF = semi-automatic operation. Factory setting: OFF. |
| L2 – Close after photocell activation | When automatic closing is enabled, photocell activation reduces the pause to 5 s. If automatic closing is disabled, photocell activation enables it with the programmed pause time. Factory setting: OFF. |
| L3 – Always close | If the gate is open, 10 s after power is restored the warning light flashes for 5 s before the gate closes. Factory setting: OFF. |
| L4 – All in standby | After one minute without movement, BlueBUS and most LEDs switch off. Factory setting: OFF. |
| L5 – ELS output as courtesy light | ON changes the electric lock output to a courtesy light. Factory setting: OFF. |
| L6 – Pre-flashing | ON activates the warning light 3 s before movement. Factory setting: OFF. |
| L7 – CLOSE as partial opening 1 | ON changes the function of the CLOSE input. Factory setting: OFF. |
| L8 – OGI as maintenance indicator | ON changes the function of the open-gate indicator. Factory setting: OFF. |
Second level: Hold Stop/Set until L1 starts flashing, then release the button; use Open/Close to select the input LED. Hold Stop/Set again; after approximately 3 s, the current value will light up. While continuing to hold Stop/Set, use Open/Close to select the value LED, then release Stop/Set and wait 10 s. Factory settings for this board are shown in bold.
| Input LED – parameter | Setting LED – value |
|---|---|
| L1 – Pause time | L1 5 s; L2 15 s; L3 30 s; L4 45 s; L5 60 s; L6 80 s; L7 120 s; L8 180 s. |
| L2 – Step-by-step mode | L1 O–S–C–S; L2 O–S–C–O; L3 O–C–O–C; L4 residential; L5 residential 2; L6 short command for pedestrian opening; L7 person present; L8 opening in semi-automatic mode and closing while holding the command. |
| L3 – Motor speed | L1 very slow; L2 slow; L3 medium; L4 fast; L5 very fast; L6 very fast; L7 fast opening/slow closing; L8 very fast opening/medium closing. |
| L4 – Relief after closing | L1 none; L2 level 1 ≈100 ms; L3 level 2; L4 level 3; L5 level 4; L6 level 5; L7 level 6; L8 level 7 ≈800 ms. |
| L5 – Motor force | L1 minimum; L2 level 2; L3 level 3; L4 level 4; L5 level 5; L6 level 6; L7 level 7; L8 maximum. |
| L6 – Pedestrian / partial opening | L1 M2 1/4; L2 M2 1/2; L3 M2 3/4; L4 full M2; L5 both leaves 1/4 of the smaller opening; L6 both 1/2; L7 both 3/4; L8 both to the smaller of the learned angles. |
| L7 – Maintenance reminder | L1 500; L2 1,000; L3 1,500; L4 2,500; L5 5,000; L6 10,000; L7 15,000; L8 20,000 manoeuvres. |
| L8 – Fault history | L1 last manoeuvre; L2–L8 second- to eighth-last manoeuvre. |
Diagnostics
On the HK7024HS, BlueBUS flashes approximately once per second during normal operation. Slow L1/L2 indicate changed or unlearned devices; slow L3/L4 indicate unlearned positions or a change to the switches after learning; relearn the positions. An unlit STOP LED indicates that a safety input has been triggered. When using a second HK7224HS motor, check these signals on the first drive, which contains the control unit.
If a fault occurs, the FLASH light repeats a group of short flashes, then repeats it after a 1-second pause. Count the flashes in one group.
| Number of FLASH flashes | What to check |
|---|---|
| 1 | BlueBUS device changed/disconnected; after fixing the issue, repeat device learning. |
| 2 | Photocell or an obstruction in its beam. |
| 3 | Increased resistance to movement or force setting; check the mechanism first. |
| 4 | STOP active or a change to a learned safety input. |
| 5 | Control unit internal parameter error; wait at least 30 s, then try the command again. If the issue persists, disconnect and restore the power supply; if it happens again, contact service. |
| 6 | Consecutive-cycle or hourly-cycle limit exceeded; wait a few minutes for the limiter to allow movement again. |
| 7 | Electrical circuit fault; wait at least 30 s, then try the command again. If the fault persists after restoring the power supply, contact service. |
| 8 | Another continuously active command is preventing movement; check the control inputs and the cause of the held command. |
| 9 | The gate was locked by a command; unlock it using the appropriate control command. |
| 10 | The encoder detected an obstruction or high friction; check the leaf's travel path. |
Restoring settings
On the integrated HK7024HS board, press and hold Open and Close, until L1 and L2 start flashing, then release the buttons. This restores the factory programming values; custom settings will be lost. After resetting, check the board wiring and indicators; if the system requests new device or position learning, perform it before operation.
Manual release and maintenance
In the event of a power failure, release the motor using the supplied key and the lever turned by 90°, then move the leaf manually. Re-engage the motor before resuming automatic operation. Carry out maintenance no later than 6 months or 20,000 manoeuvres: check for wear, bracket tightness, stops, free gate movement and safety devices.
Estimated service life
The duty index is the sum of the effects of length, weight, full or shortened arm, temperature/humidity, solid leaf and wind. The manufacturer's values are indicative and do not guarantee a specific number of cycles. First check that the length and weight combination is permitted in the HYKE HS chart above; only then use the index to estimate service life. The cycle-count chart is not a guarantee.
| Characteristics of the complete automation system | Index | Service life chart |
|---|---|---|
Technical specifications and dimensions
| Parameter | Value |
|---|---|
| Model | NICE HYKE HK7024HS |
| Application | HighSpeed articulated-arm drive with an integrated control unit for one or two leaves. |
| Motor voltage | 24 V DC |
| Power supply | 230 V AC, 50/60 Hz to the built-in control unit; motor is 24 V DC. |
| Power consumption / current draw | 300 W; 1.5 A at the mains input. |
| No-load speed | 2 rpm; 90° travel time approximately 10 s under standard installation conditions, excluding acceleration and deceleration. |
| Starting / rated torque | 500 / 120 Nm. |
| Operation | Maximum 40 cycles/h at rated torque; maximum continuous operation 7 min. |
| Operating temperature | −20 to +50 °C according to the current catalogue. |
| Ingress protection rating | IP54 with the cover intact. |
| Motor dimensions | 290 × 210 × 320 mm. |
| Motor weight only | 10.5 kg. |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]