High-speed NICE Hyke HK7224 HS drive

NEW


Product availability: within 7 days

We usually dispatch goods within 7 days.


High-speed NICE Hyke HK7224 HS drive High-speed NICE Hyke HK7224 HS drive
NICE-HK7224HS
within 7 days
€495.52 excluding VAT
€609.49 including VAT

 pcs
Weight
13 kg

Description of High-speed NICE Hyke HK7224 HS drive

NICE HYKE HK7224HS is a fast articulated non-backdrivable drive for one leaf of a swing gate. It is the second motor, without a control unit; for a double-leaf gate, it must be paired with the HK7024HS. The HK7224HS on its own is not a complete drive for a single-leaf gate.

The motor runs on 24 V DC. It is powered and controlled by the built-in drive unit in the HK7024HS; the HK7224HS must not be connected directly to the 230 V mains. The articulated arm can also be fitted when the hinge is offset on a wider mounting surface, provided the position and clearance comply with the installation diagram. With a standard installation, opening to 90° takes approximately 10 seconds.

Quick navigation
Choosing a driveAccessories
InstallationArm and stops
WiringTerminals
First startupProgramming
TroubleshootingReset
MaintenanceService life
SpecificationsPDF manual

Drive selection and leaf limits

HYKE HS has separate maximum limits of 3 m in length and 270 kg in weight. These limits do not apply at the same time: the permitted combination is determined by the graph. According to the graph, a 3 m leaf can weigh approximately 175 kg; a 1.8 m leaf can weigh approximately 260 kg. Therefore, a leaf measuring 3 m and weighing 250 kg is not a permitted combination. Solid infill, wind, poor balancing or resistance to movement can further reduce the limit.

Original NICE HYKE HS graph: leaf weight by leaf length

The graph shows leaf length horizontally and weight vertically single leaf.

With a shortened arm, the operating range is smaller than with the full-length arm. Before choosing, check that the gate moves freely, the leaf is sturdy and the arm can be positioned safely. One motor is required per leaf; two motors do not increase the permitted weight of a single leaf.

Controls and compatible accessories

WhatWhyType
Motor and control unitOne motor per leaf. The drive requires the HK7024HS to control the complete double-leaf gate system.
  • Control unit integrated into the HK7024HS; the HK7224HS is not a standalone control unit.
Radio receiverSM connector on the HK7024HS control unit; select a receiver compatible with the transmitter's coding.
Remote controlPair it with the installed receiver; frequency alone does not determine compatibility.
Photoelectric cellsBlueBUS safety devices; run the learning procedure after adding them.
Warning lightIndicates movement. The FLASH output is 12 V DC / max. 21 W.
  • ELDC or WLT depending on the mode and output load.
Backup power supplyFor HK7024HS during a power failure, after checking the control board and connector.
  • PSS124. The older PS124 requires the appropriate adapter; do not connect it directly.

Installation and site inspection

The substrate must securely support the bracket, and the arm must rotate freely throughout its entire travel. Allow at least 210 mm of clearance. For the installation shown, the distance from the motor axis to the opposite obstruction must be at least 300 mm; measure the additional 150 mm dimension and hinge offset according to the relevant drawing. These are not universal post dimensions. A hinge offset of up to approximately 400 mm is possible only with geometry matching the drawing and chart. Choose the bracket anchors to suit the actual substrate; they are not included with the motor.

Original installation drawing: 300 mm from the motor axis to the obstruction for arm rotation

Original NICE HYKE HS: clearance around the articulated arm

Before drilling, measure the hinge axis position, bracket position and required angle. For the full-length arm, use the original A/B dimension chart; secure the gate-leaf bracket to a solid part of the frame. With the full-length arm, the maximum opening angle is 110° according to the installation chart. Repair the gate first if it binds, is deformed or lacks secure mechanical stops.

Original drawing of the hinge axis and installation dimension A

Original NICE chart for selecting installation dimensions A and B

Full-length and shortened arms, end stops

Measure the clearance dimension E at the obstruction. Use the full-length arm when E is at least 650 mm; when E is 300–650 mm, shorten it according to the installation instructions. The shortened arm limits the allowable angle and the combination of length and weight; for this configuration, refer to the chart and do not exceed the planned opening angle. Shorten the arm only at the designated points on the original arm; do not estimate the cut positions.

Original NICE HYKE installation of the articulated arm and bracket

After securing the motor, position the arm and gate-leaf bracket at the furthest secure point, check that the arm engages correctly in the end position, and set the mechanical opening and closing stops. With the motor released, move it manually through its full travel; movement must be smooth and free of collisions.

Electrical connections

Connect this motor to the M2 output of the HK7024HS control unit and its encoder to ENC2; terminals M1/ENC1 are for the first motor. Verify the gate-leaf sequence during learning. The control unit supplies 24 V DC; do not connect the motor directly to the mains supply. Disconnect the mains supply and backup power source before working on the system. For the second motor, use a 3 × 1.5 mm² cable up to 10 m long and a 2 × 1 mm² encoder cable up to 10 m long; the specific cable route and cross-section must suit the installation.

Original wiring diagram for the motor, encoder, BlueBUS and contacts on the HYKE

Accessory power supply and polarity

TerminalsConnection
BlueBUSTwo wires for compatible photocells; non-polarized. Repeat the learning procedure after changing devices.
SbS (+) and STOP (−)Auxiliary 24 V DC, maximum 200 mA between the terminals marked as shown on the integrated board. Voltage remains present in standby mode. These terminals also serve as command and safety inputs; the accessory power supply must be compatible with the contact wiring.
STOP, SbS, OPEN, CLOSEVoltage-free contacts; STOP can be configured as NO, NC or an 8.2 kΩ resistor, depending on the learning procedure. No +/− polarity applies to the contact itself.
ENC1 / ENC2Encoder for the corresponding motor; refer to the manual non-polarized.
FLASH12 V DC, maximum 21 W; choose a warning light to suit the operating mode and power consumption. Do not guess the polarity of individual unmarked terminals.
ELS / OGIELS: 12 V AC lock, maximum 15 VA. OGI: 24 V DC indicator, maximum 4 W. The outputs can be reassigned through programming.

Initial startup and position learning

The HK7224HS has no programming buttons or built-in control unit. The HS type, position learning and operating functions are configured on the board in the HK7024HS. The following steps apply only to this type of setup with the 12-position switch shown in the diagram.

When connecting to the HK7024HS, first have the integrated board detect BlueBUS and STOP, then set the HYKE HS switch and learn the end positions. For a double-leaf gate, the control unit must correctly identify M1 and M2. If the initial movements or sequence are incorrect, stop the learning procedure and check the motor and encoder wiring.

Programming on the integrated board

Functions can only be configured on the motor's integrated board HK7024HS. When replacing the board, check its actual markings and switch layout.

Diagnostics

On the HK7024HS, BlueBUS flashes approximately once per second during normal operation. Slow flashing of L1/L2 indicates changed or unlearned devices; slow flashing of L3/L4 indicates unlearned positions or a change to the switches after learning; relearn the positions. An unlit STOP LED indicates that the safety input has been triggered. For the second HK7224HS motor, check these indicators on the first drive, which has the control unit.

In the event of a fault, the FLASH light repeats a group of short flashes, then repeats the group after a 1-second pause. Count the flashes in one group.

Number of FLASH blinksWhat to check
1BlueBUS device changed or disconnected; after fixing the issue, repeat device learning.
2Photocell or an obstruction in its beam.
3Increased resistance to movement or force setting; check the mechanics first.
4STOP active or a change to a learned safety input.
5Control unit internal parameter error; wait at least 30 seconds, then try the command again. If the error persists, disconnect and restore the power supply; if it recurs, call for service.
6The limit for consecutive cycles or cycles per hour has been exceeded; wait a few minutes for the limiter to allow movement again.
7Electrical circuit fault; wait at least 30 seconds, then try the command again. If the fault persists after restoring the power supply, call for service.
8Another continuously active command is preventing movement; check the control inputs and identify why the command is being held.
9The gate was locked by a command; unlock it using the corresponding control command.
10The encoder detected an obstruction or excessive friction; check the gate-leaf travel path.

Restoring settings

On the HK7024HS integrated board, press and hold Open and Close, until L1 and L2 start flashing, then release the buttons. This restores the factory programming values; any custom settings will be lost. After resetting, check the wiring and board indicators; if the unit requests new device or position learning, complete it before operation.

Manual release and maintenance

If the power fails, release the motor using the supplied key and lever turned 90°, then move the gate leaf by hand. Secure the motor again before returning to automatic operation. Carry out maintenance no later than every 6 months or 20,000 cycles: check for wear, secure brackets, stops, smooth gate movement and safety devices.

Estimated service life

The duty index is the sum of the effects of length, weight, full-length or shortened arm, temperature/humidity, solid gate leaf and wind. Manufacturer values are indicative only and do not guarantee a number of cycles. First check the permitted combination of length and weight in the HYKE HS chart above; only then use the index to estimate service life. The cycle-count chart is not a guarantee.

Specifications of the complete automation systemIndexService life chart

Original table of difficulty factors for HYKE

Original NICE HYKE estimated service life chart

Technical specifications and dimensions

ParameterValue
ModelNICE HYKE HK7224HS
ApplicationHigh-speed articulated drive for one gate leaf; HK7224HS is the second motor, supplied without a control unit.
Motor voltage24 V DC
Power supply24 V DC from the HK7024HS control unit; no separate mains connection.
Power consumption / current draw140 W; up to 6 A briefly (max. 2 s).
No-load speed2 rpm; 90° movement takes approximately 10 s with standard installation, excluding start-up and slowdown.
Starting / rated torque500 / 120 Nm.
OperationMax. 40 cycles/h at rated torque; continuous operation for max. 7 min.
Operating temperature−20 to +50 °C according to the current catalogue.
Ingress protection ratingIP54 with the cover intact.
Motor dimensions290 × 210 × 320 mm.
Motor weight (motor only)9.5 kg.

Original NICE HYKE HS motor dimensions

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about High-speed NICE Hyke HK7224 HS drive

Product: High-speed NICE Hyke HK7224 HS drive
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.