Manual for a track-mounted sliding gate

Technical guide · DIY construction · track sliding gate

This guide will help you prepare the space for a track sliding gate and choose the rail, wheels, guide system and drive. You’ll also find sample drawings for openings from 2.5 to 6.5 m. The drawings are provided as a planning reference.

Track sliding gate with wheels, stop and drive

Image of a track sliding gate. Click to open it at a larger size.

Track gate: from foundations to finished assembly

A track gate carries its weight on the bottom wheels and runs along a rail laid throughout the gate’s entire travel path. When planning, first check that there is enough room for the gate to open, prepare a level base and install the wiring, then match the rail profile to the wheels, and finally choose the guide system, stops, lock and, if needed, a drive.

Main components of a track sliding gate

The gate leaf runs on a pair of bottom wheels. The wheels transfer the weight down to the rail and supporting surface. The top or side guide keeps the gate aligned laterally, but must not carry its weight.

Track system components

Running gear U-shaped rail (U16 or U20) or V-shaped rail and compatible wheels fitted in the frame’s bottom channel section.
Gate guide system Top guide between the rollers or side guide in a U/L-profile.
End positions Bottom and top stops that stop and stabilize the gate.
Optional accessories Hook lock, handles, pull handles, drives, rack rails, photocells, warning lights and NICE remote controls (remotes from other brands).

The most important compatibility requirement: the wheel groove profile and diameter must match the rail used. A wheel for U16 cannot be used on a U20 rail, and a V-groove wheel must be used on a V-shaped rail.

Clearance, rail and concrete foundation

The rail must be laid in a straight line, with no breaks between sections. The gate travels along it across the clear opening and continues into the space alongside the fence. If the wheels are positioned at the ends of the frame, the rail must extend beneath the full travel path of the wheels.

Rail / concrete foundation

Diagram of the running rail, bottom stops and drive foundation

Installation of the running gear and drive foundation.

Views showing the rail installation, drive foundation and clearance required to open the track gate

Front, side and plan views of the rail and drive foundation installation.

Legend for the foundation diagrams

ŠP Clear opening width.
DK Running rail length.
SD Bottom stop.
ZP Gate drive foundation.

The labels refer to the images above the legend. Determine the exact dimensions and installation clearances from the current drawing for the selected product.

Clearance for opening: measure the gate leaf’s entire travel path, including the frame overhang, wheel positions, stops and space for the drive. Determine the exact dimensions from the current drawing for the selected components.

Preparing the wiring and drive

Even if you initially plan to operate the gate manually, it’s a good idea to install the conduits before pouring the concrete. You can then add a drive, photocells, warning light or key switch without having to cut into the finished base.

Wiring preparation drawing: drive installation, conduits to the photocells and warning light, and a detail of the cable outlets by the drive

Wiring preparation, figures 5–7. Branch labels A–D correspond to the table below. Click to open a detailed view.

Indicative wiring for selected drives

Connection NICE ROAD 400 NICE ROBUS 400/600/1000
A - 230 V power supply 1 × 3 × 1.5 mm² 1 × 3 × 1.5 mm²
B - left photocell 1 × 2 × 0.25 mm² 1 × 2 × 0.5 mm²
C - right photocell 1 × 4 × 0.25 mm² 1 × 2 × 0.5 mm²
D - warning light 1 × 2 × 0.5 mm² + thin RG58, 50 Ω coaxial cable 1 × 2 × 0.5 mm² + thin RG58, 50 Ω coaxial cable

For a power cable longer than 30 m, the manufacturer requires a larger conductor cross-section than 3 × 1.5 mm² for NICE ROBUS RB400/RB600/RB1000 drives.

Optional rail heating: A resistance heating cable can be installed inside the rail. Since the gate area usually has a drive and a 230 V supply, the heating can be controlled by a temperature or humidity sensor, or by a simple switch.

Drive wiring diagrams

Choose the diagram that matches the drive and control unit model. Older NICE Robus RB and newer NICE Robus RBS models have different terminal blocks. Their wiring diagrams are not interchangeable. Always refer to the manual for the specific unit.

NICE Robus RB400 / RB600 / RB1000

Diagram for connecting accessories to NICE Robus RB400, RB600 and RB1000 drives, from the manufacturer’s installation manual

Diagram from the NICE ROBUS400/600/1000 installation manual, printed page 11, figure 7. Click to open a detailed view.

NICE Robus RBS400 / RBS600

NICE Robus RBS400/600 control unit component wiring diagram, including an enlarged terminal block detail, Figure 12

Wiring diagram for the individual components of the RBS400/600 control unit, Figure 12. Click to open the diagram and terminal block detail at full resolution.

NICE Robus RBS400/600 drive mains cable wiring diagram with connection detail, Figure 13

Mains cable wiring, Figure 13. Click to open a clear close-up.

The original wiring diagram is also available for the older ROAD setup: original NICE ROAD 400 diagram. Current range: NICE sliding gate operators.

Choosing a track for a tracked gate

Choose the track profile first, then select the wheels. The U-track has a rounded running surface for U-groove wheels, while the V-track has a 90° apex and takes V-groove wheels. Tracks for screw fixing are anchored to a cured, level base; the cast-in version is installed during concreting.

Standard straight tracks in the current category

Track Profile Installation Material
U16 track for screw fixing U16 screw-fixed Zn
U20 track for screw fixing U20 screw-fixed Zn
V-track for screw fixing V screw-fixed Zn
U20 track for casting into concrete U20 cast-in Zn
INOX U16 track for screw fixing U16 screw-fixed INOX
INOX U20 track for screw fixing U20 screw-fixed INOX
INOX V-track for screw fixing V screw-fixed INOX

The table covers standard U- and V-profile tracks. Curved tracks are intentionally omitted. See the full current range in the category tracks for tracked sliding gates.

Choosing wheels for a tracked gate

Once you have matched the track profile, choose wheels based on the gate weight, wheel diameter and mounting method. A gate is usually fitted with one pair of wheels, so the load capacity shown on product pages for standard models is specified per pair.

Tracked gate wheel with screw-fixing bracket

With bracket
View wheel

Recessed tracked gate wheel for screw fixing

Recessed, screw-fixed
View wheel

Recessed tracked gate wheel for welding

Recessed, weld-on
View wheel
  • The wheel with bracket is the most commonly used option and is easier to install.
  • A recessed wheel is used when you want to reduce the clearance between the gate and the ground. It is recessed into the structure's bottom profile.
  • A recessed wheel can be bolted or welded to the structure, depending on the type.

Current standard wheel options

Product Track Available diameters
IBFM wheel with screw-fixing bracket U16 Ø50, Ø60, Ø80, Ø90, Ø100
IBFM recessed wheel for screw fixing U16 Ø60, Ø80, Ø90, Ø100
IBFM recessed wheel for welding U16 Ø60, Ø80, Ø90, Ø100
IBFM wheel with screw-fixing bracket U20 Ø80, Ø100
IBFM recessed wheel for screw fixing U20 Ø80, Ø100, Ø140
IBFM wheel with screw-fixing bracket V Ø50, Ø60, Ø80, Ø90, Ø100
IBFM recessed wheel for screw fixing V Ø60, Ø80, Ø90, Ø100
IBFM recessed wheel for welding V Ø80, Ø90, Ø100

Select the diameter from the variant table on the relevant product page.All wheels for tracked gates

Choosing a tracked gate guide

The guide keeps the top of the gate aligned in its track. It does not support the weight of the gate leaf, and the rollers must not clamp the frame so tightly that the gate binds.

Top guide for a tracked sliding gate, with the gate between rollers

Top guide with the gate between rollers
View top guide

Side guide for a tracked sliding gate using a roller inside a profile

Side guide using a roller inside a U- or L-profile
View side guide
Top guide Side guide
Use when the infill does not extend above the frame's top profile. Anchor the roller bracket to a fence, wall or levelling post. Use when the infill is to extend above the frame. A U- or L-section is welded to the inside of the gate leaf, and the roller from the post runs in it.

Choose the guide system to suit the gate frame and infill.All guide systems for track gates

Stops, locking and controls

Gate stops

The bottom stop catches the frame when the gate is fully open or closed. The top stop also stabilizes the gate leaf in its end position. The gate operator stops the gate at the set end positions. Keep the mechanical stops in place as well; they will catch the gate when it is moved manually after the operator is disengaged.

See bottom and top stops for track gates.

Manual locking

A hook lock is used for a manually operated gate. With a track gate, you also need a pin or another mechanism to prevent the gate leaf from being lifted out of the lock. Choose a compatible handle or pull handle to suit the thickness of the frame and infill.

See locks, handles and pull handles for track gates.

Gate operator controls

The gate can be operated using a NICE remote control or a remote control from another brand, a key switch, push button, keypad, reader or smart module. Check the compatibility of the receiver and controls against the specific control unit, not just the operator brand.

Checks before installing the gate operator

Before installing the gate operator, move the gate manually through its full travel. It must move smoothly, without sticking or excessive resistance. Check the guides and stops. The gate operator must not be used to compensate for an error in the mechanical installation.

Track gate drawings for clear openings of 2.5 to 6.5 m

Click the image to open the drawing. Basic dimensions, profiles and weights are also listed in the text below.

The stated values are not universal load capacities for every gate with the same clear opening width.

Track gate with a clear opening width of 2.5 m

Track gate construction drawing for a 2.5 m clear opening

Click to open the complete drawing in full resolution.

  • Overall gate length 2.8 m
  • With operator 3.0 m
  • Bottom profile J80 × 40 × 2 / 3 m
  • Frame J60 × 40 × 2 / 10 m
  • Net weight 39 kg
  • Max. load per metre 250 kg/m
  • Max. infill weight 700 kg
  • Max. total weight 740 kg

Track gate with a clear opening width of 3.0 m

Track gate construction drawing for a 3.0 m clear opening

Click to open the complete drawing in full resolution.

  • Overall gate length 3.3 m
  • With operator 3.5 m
  • Bottom profile J80 × 40 × 2 / 4 m
  • Frame J60 × 40 × 2 / 13 m
  • Net weight 48 kg
  • Max. load per metre 205 kg/m
  • Max. infill weight 675 kg
  • Max. total weight 740 kg

Track gate with a clear opening width of 3.5 m

Track gate construction drawing for a 3.5 m clear opening

Click to open the complete drawing in full resolution.

  • Overall gate length 3.8 m
  • With operator 4.0 m
  • Bottom profile J80 × 40 × 2 / 4 m
  • Frame J60 × 40 × 2 / 14 m
  • Net weight 52 kg
  • Max. load per metre 235 kg/m
  • Max. infill weight 880 kg
  • Max. total weight 960 kg

Track gate with a clear opening width of 4.0 m

Track gate construction drawing for a 4.0 m clear opening

Click to open the complete drawing in full resolution.

  • Overall gate length 4.3 m
  • With operator 4.5 m
  • Bottom profile J80 × 40 × 2 / 5 m
  • Frame J60 × 40 × 2 / 16 m
  • Net weight 61 kg
  • Max. load per metre 205 kg/m
  • Max. infill weight 880 kg
  • Max. total weight 960 kg

Track gate with a clear opening width of 4.5 m

Track gate construction drawing for a 4.5 m clear opening

Click to open the complete drawing in full resolution.

  • Overall gate length 4.8 m
  • With operator 5.0 m
  • Bottom profile J80 × 40 × 2 / 5 m
  • Frame J60 × 40 × 2 / 17 m
  • Dead weight 66 kg
  • Max. load per metre 185 kg/m
  • Max. infill weight 885 kg
  • Max. total weight 960 kg

Track gate with a clear opening width of 5.0 m

Construction drawing of a track gate for a clear opening width of 5.0 m

Click to open the complete drawing in full resolution.

  • Overall gate length 5.3 m
  • With drive 5.5 m
  • Bottom profile J80 × 40 × 2 / 6 m
  • Frame J60 × 40 × 2 / 18 m
  • Dead weight 70 kg
  • Max. load per metre 165 kg/m
  • Max. infill weight 870 kg
  • Max. total weight 940 kg

Track gate with a clear opening width of 5.5 m

Construction drawing of a track gate for a clear opening width of 5.5 m

Click to open the complete drawing in full resolution.

  • Overall gate length 5.8 m
  • With drive 6.0 m
  • J80 × 40 × 2 profiles 15 m
  • J60 × 40 × 2 profiles 12 m
  • Dead weight 84 kg
  • Max. load per metre 150 kg/m
  • Max. infill weight 870 kg
  • Max. total weight 955 kg

Track gate with a clear opening width of 6.0 m

Construction drawing of a track gate for a clear opening width of 6.0 m

Click to open the complete drawing in full resolution.

  • Overall gate length 6.3 m
  • With drive 6.5 m
  • J80 × 40 × 2 profiles 16 m
  • J60 × 40 × 2 profiles 12 m
  • Dead weight 89 kg
  • Max. load per metre 130 kg/m
  • Max. infill weight 815 kg
  • Max. total weight 905 kg

Track gate with a clear opening width of 6.5 m

Construction drawing of a track gate for a clear opening width of 6.5 m

Click to open the complete drawing in full resolution.

  • Overall gate length 6.8 m
  • With drive 7.0 m
  • J80 × 40 × 2 profiles 17 m
  • J60 × 40 × 2 profiles 13 m
  • Dead weight 94 kg
  • Max. load per metre 90 kg/m
  • Max. infill weight 610 kg
  • Max. total weight 700 kg

The dimensions shown are examples. Profiles may be larger or may also be positioned diagonally. For hot-dip galvanizing, material with a 3 mm wall thickness is recommended to reduce the risk of the frame twisting.

The weight and load values do not constitute a structural assessment of a specific gate. For a heavy solid infill, an exposed location, a non-standard height or dimensions, have the frame, wheels, track, anchoring and drive checked.

Choose a component kit more easily

The ready-made kit combines the track, wheels, stops and guide components to suit the opening width. Choose based on the opening width, finish and whether the kit should also include a drive.

Standard refers to kits with zinc-coated metal components for surface protection. INOX refers to stainless-steel metal components. Non-metal parts, such as nylon rollers, vary depending on the specific kit. For kits with a drive, its type is listed directly in the table.

All nine track gate kits in our range

Kit / opening width Finish Drive included
Kit up to 3.0 m Standard No drive
Kit up to 4.5 m Standard No drive
Kit up to 6.5 m Standard No drive
Kit up to 3.0 m Standard NICE Road 400
Kit up to 4.5 m Standard NICE Robus RBS400
Kit up to 6.5 m Standard NICE Robus RBS600
Kit up to 3.0 m Stainless steel Without drive
Kit up to 4.5 m Stainless steel Without drive
Kit up to 6.5 m Stainless steel Without drive

Choose the type of rollers and guide on the product page according to the installation method and gate infill. Always check the exact contents, available options, price and stock availability for the specific kit.

Full current range: sliding gate kits.

Didn't find the answer? Call us

If you couldn't find the information you're looking for, contact us. We'll help you choose components for your specific sliding gate.

Information we need to select suitable products for you

  • the clear opening width and the total space available for opening,
  • the dimensions of the entire gate leaf and its estimated weight including infill,
  • whether the rail is to be bolted down or set in concrete,
  • a photo or sketch of the site and information about the substrate type,
  • whether the gate will be manual or powered.
Technical note: The manual is a practical aid, not a substitute for a design, structural assessment or the current installation instructions from the drive manufacturer. Safety devices and electrical installation must be designed for the specific gate and in accordance with applicable regulations.

Prepared by Eng. Ján Kubíček.

Last updated: 16. 9. 2026.

Back to the beginning of the manual