Simplified procedure for connecting and starting NICE Road gate operators
If you don’t feel like reading the entire manual for Road operators, you can get your NICE Road operator up and running in just a few minutes using this simplified wiring and setup procedure.
We assume your sliding gate moves freely and that you have completed the steps for installing the rack, installing the operator, and fitting the rack end stops.
In other words, the operator is disengaged, the gate can be moved manually, and the operator’s limit switch activates in both the closed and open positions.
The easiest way is to get the operator itself moving first, without any accessories, which you can connect one by one later. But feel free to connect the accessories straight away; it doesn’t matter when you do it, as anything can be connected or disconnected at any time. You can always restore the operator to its factory settings.
Step 0. Wiring
Power supply cable
Terminal L – live wire from the power supply cable
Terminal N – neutral wire from the power supply cable
Terminal marked with the earth symbol – earth wire from the power supply cable
Warning light
Connect the two-core cable from the warning light, from the terminal marked with the light-bulb symbol, to terminals 7–8 on the control unit. If you are not installing a warning light, leave terminals 7–8 unconnected.
Antenna
The antenna terminal, marked with the antenna symbol, is at the top right. If you have an antenna, either a separate one or one built into the warning light, connect it to this terminal. If you don’t have an antenna, you can connect a short piece of wire to the hole marked with the tree-shaped symbol. You can also leave the terminal unconnected for now.
Photocells
If you don’t have photocells, bridge inputs 1 and 5 on the control unit. If you do, connect them as follows:
Connect terminal 1 from each photocell to terminal 1 on the control unit.
Connect terminal 2 from each photocell to terminal 4 on the control unit.
Connect terminal 4 on the RX photocell to terminal 1 on the control unit.
Connect terminal 5 on the RX photocell to terminal 5 on the control unit.
Do not interrupt any circuits on the photocell circuit board. More about wiring photocells.
Step 1. How to get the operator moving:
- Disconnect the operator from the power supply. The easiest way is to remove the power fuse.
- Manually move the gate to roughly the middle of its travel (so it is neither open nor closed), engage the operator, then pull the gate leaf slightly so the gearbox engages.
- Set the gate opening direction selector switch on the control unit. If you are standing inside the property, facing the gate from the inside:
- if the operator is on the left (the gate opens to the left), set the switch to the left as well;
- if the operator is on the right (the gate opens to the right), set the switch to the right.
- Restore power to the operator.
- With the factory settings (or after a reset), LEDs L1+L2+L3 on the control unit should flash together.
- Press the OPEN button once, without holding it down, then L2+L3 will start flashing. The control unit will read the input status and begin measuring the gate leaf’s travel. The gate will close, open, and close again. LED L4 will then keep flashing; wait for it to go out (about 10 seconds).
- Congratulations—you’ve got your NICE Road sliding gate operator up and running! You should now be able to operate the gate using the OPEN, STOP/SET, and CLOSE buttons. The OPEN button opens the gate, CLOSE closes it, and STOP/SET stops it.
If you haven’t already, you can connect the photocells, warning light, key switch, or other accessories, and pair the remote controls.