Operating the pedestrian gate's electric lock with a remote control

Electric lock on the entrance gate can also be operated by the remote control for the gate opener. The gate opener control units NICE Robus and NICE Run. Connect the OGI input on the gate opener control unit to the electric lock using a two-core cable 24V.

In Level II programming reprogram the OGI output (L4) to L4, L5, or L6.
The OGI output will then operate as follows:

  • L4 - Activates only on radio channel no. 2, so if your remote is paired in Mode I, it will switch on when you press the second button on the remote.
  • L5 - Activates only on radio channel no. 3, see the previous point
  • L6 - Activates only on radio channel no. 4, see the previous point

On the remote control, select the button you want to use to operate the electric lock and pair it with the receiver according to the value you selected for the OGI output. For example, if you selected L5, pair the third button on the remote.

If you don't have a Robus gate opener, you can do this with an external receiver; read on here.