NICE Robus RBS – how to connect a switch (video doorbell, intercom) to the operator

The home video doorbell/intercom is connected to the NICE Robus RBS drive via a volt-free contact to the SBS input (on older control units, this is labelled P.P.)
After connecting to this input, you need to run the “Learning connected drive devices” procedure on the Robus. Procedure:

Learning connected drive devices

After connecting, disconnecting, or changing the wiring of additional devices connected to the BlueBUS inputs and STOP the additional-device learning phase. The drive will alert you that this procedure is required by flashing LEDs L1 and L2.

Learning additional devices on the Nice Robus RBS

  1. Press the “Open” and “Stop/Set” buttons and hold them down
  2. As soon as they start flashing rapidly L1 and L2, release the buttons
  3. Wait a few seconds for the control unit (MCU1 / MCU4) to complete the device learning process.
  4. If everything went well, the STOP LED should be lit and L1 and L2 should be off. Alternatively, L3 and L4, may flash if you have not yet completed the leaf length learning phase.