NICE Road RD400 Technical Manual
NICE Road RD400 is a drive for residential sliding gates up to 400 kg and a gate leaf length of 8 m, with mechanical limit switches. Our store recommends a maximum of 5 m and approximately 250 kg with suitable mechanics; this is not an additional manufacturer limit. Selection and duty cycle · Technical specifications.
(Is this drive right for me?)
Compare with other drives:
| Item | Meaning / procedure |
|---|---|
| Alternative drive | NICE Robus RB400 – compare the specifications and available revision on its product page. |
| Higher weight class | NICE Robus RB600 – the choice also depends on the length, friction and frequency of use. |
This product—the standalone NICE Road RD400 sliding gate drive (our code NICE-RD400-A)—includes:
- electromechanical NICE Road RD400 drive with a capacity of 400 kg and a maximum gate leaf length of 8 m, and a built-in (but removable) control unit RBA4R10 with a built-in radio receiver (if you want to operate the gate by remote control, there is no need to purchase a separate receiver).
- 2 × release keys for manual operation of the drive (required in the event of a power outage)
- drive installation components, anchor fasteners and a bracket, limit switch stops for the drive
- installation manual
Discounted kits containing the drive NICE Road RD400:
| Drive kit with accessories » | Drive kit with accessories and rack » |
|---|---|
|
Road drive for gates up to 400 kg, remote control, photocells, warning light. |
ROAD drive for gates up to 400 kg, rack, remote control, photocells, warning light. |
| Cantilever gate fabrication kit » | Track gate fabrication kit » |
5-bearing carriages, 5 m steel C-profile, end catcher, receiver, guide, drive, rack. |
Ø90 mm wheels, 3 × 3 m Zn track, bottom stops, guide, drive, rack |
The RD400 is designed for residential use. Suitability depends on the condition of the gate, its length and weight, frequency of use, and the design of the safety devices.
Relay photocells are used, for example NICE EPM. When using multiple pairs, connect the safety NC contacts in series; arrange the power supply and pairs according to their instructions. The RD400 does not have BlueBUS terminals.
The following can be adjusted: speed, force, pause time and automatic closing. See the section Programming.
Diagnostics using warning light.
Pinion module 4 is compatible with rack in our range.
Choosing the right drive is only one part of having a safe gate. After installation, a technician must check the entire automation system, including the safety functions and forces, and hand it over to the user.
Accessories compatible with the NICE Road RD400 drive
When choosing accessories, the output type, power supply and radio protocol are key. The links below lead to products in our range.
| What | Why / connection | Type |
|---|---|---|
| Warning light | Movement indication on FLASH 7–8. The antenna is connected separately. | NICE ELDC |
| Photocells | PHOTO relay safety contact. Connection with photocell testing. BlueBUS models cannot be connected directly. | NICE EPM or NICE EPMA; the specific terminals below are for EPM. |
| Key switch | Local SbS command via a volt-free C–NO contact between 1 and 2. | NICE EKS |
| Remote controls | Pairing with the built-in receiver. The first remote control paired determines the supported family; frequency alone is not enough. | NICE ON2E, NICE ON4E (O-Code), NICE FLO2RE (FloR). |
| Antenna | Improved reception of radio commands. Separate RG58 coaxial cable to the antenna input. | NICE ABFKIT or the ELDC warning light antenna. |
| Backup battery | Operation during a mains power failure for the RD400 generation described. | NICE PS124 – 1.2 Ah, built-in charging. |
| Service interface | Configuration and diagnostics via BusT4. Connect with the power supplies disconnected. | NICE IBT4N + NICE OVIEW |
| Rack | Transmits movement to the gate leaf. Module 4; fixing and load capacity depend on the rack type. | NICE LZ-1, NICE LZ-10 or steel NICE LZ-3. |
| Additional control | External module for the SbS input. Suitable power supply and a volt-free NO contact. | Keypads and readers that require a decoder cannot be connected directly to SbS. |
NICE Road RD400 at a glance
The RD400 has a built-in radio receiver. The control board described has four buttons and supports an optional battery NICE PS124. If the mains power fails, the gate can also be manually released.
RBA4R10 control unit with four buttons. Check the board and terminal markings before wiring. Click to enlarge the image.
Choosing a drive – is the NICE Road RD400 suitable for my gate?
Once released, the gate must move smoothly by hand along its entire travel. Binding, damaged carriages or wheels, and an incorrectly installed rack must be fixed before adjusting the force. Weight alone does not determine how much resistance the gate offers.
| Gate leaf length | Max. cycles/hour | Max. consecutive cycles |
|---|---|---|
| Up to 5 m | 20 | 15 |
| Over 5 m up to 7 m | 16 | 12 |
| Over 7 m up to 8 m | 14 | 9 |
| Gate leaf weight | Percentage of the cycle count above |
|---|---|
| Up to 200 kg | 85% |
| Over 200 kg up to 300 kg | 70% |
| Over 300 kg up to 400 kg | 70% |
One cycle means opening and closing. Length-based limits are multiplied by the weight percentage; round down when counting whole cycles. For example, 6 m / 350 kg: 16 × 0.70 = 11 full cycles per hour, with a maximum of 8 consecutively. The limit of 50 cycles per day and a maximum of 9 minutes of continuous operation also apply. Temperature conditions may further limit the available operation.
NICE Road RD400 drive limits
For a reasonable selection margin, our store recommends a maximum of approximately 5 m and 250 kg. This is a sales recommendation; a technician must assess the specific gate. The following table distinguishes this recommendation from the manufacturer's limits.
| Maximum | Recommended | |
|---|---|---|
| Gate leaf length | 8 m | 5 m |
| Gate leaf weight | 400 kg | 250 kg |
Service life and maintenance
The drive's service life depends on the gate mechanics, load, environment and maintenance. Carry out maintenance at least every 6 months or after no more than 10,000 movements since the last service, whichever comes first.
Installing the NICE Road RD400 drive
Install the drive on a firm, level foundation at the correct height relative to the rack. The anchoring must suit the substrate and the RD400 mounting plate. For both cantilever and track-mounted gates, prepare cable conduits, drainage, and enough space for release and servicing.
Wiring
Accessory layout according to the original RD400 manual. The number of safety devices required depends on the assessment of the specific gate.
Device layout: lowercase letters indicate devices, uppercase letters indicate cable routes. Click to enlarge the image.
List of accessories
| Item | Meaning / procedure |
|---|---|
| a / b / c | Operator / photocells / photocell posts. |
| d / e | Key switch or keypad / warning light. |
| f / g | Rack / safety contact edges. |
Wiring list
| Item | Meaning / procedure |
|---|---|
| A – power supply | 3 × 1.5 mm² up to 30 m; for a longer supply cable, the manufacturer specifies, for example, 3 × 2.5 mm² and grounding for the automation system. |
| B – warning light / antenna | 2 × 0.5 mm² up to 20 m; separate RG58 up to 20 m, with less than 5 m recommended. |
| C – EPM photocells | TX: 2 × 0.25 mm². RX: power supply and safety contact, e.g. 4 × 0.25 mm² up to 30 m. The diagram below identifies all the conductors. |
| D – key switch | 2 cables, 2 × 0.5 mm², or 1 cable, 4 × 0.5 mm², up to 50 m; for a single C–NO command, use two conductors. |
| E / F – contact edges | 2 × 0.5 mm² up to 30 m. A suitable signal transmission method is required on the moving gate leaf. |
Cables must be suitable for the environment, and their routes must separate mains voltage from control circuits. In addition to the power pair, the relay-type RX requires conductors for the safety contact.
Installation
See “At what height should I install the operator".
The rack and its stop
The gate moves by transferring the torque of the operator’s pinion into linear motion via the rack-and-pinion drive on the operator rack. The two most commonly used types of rack are:
![]() |
Nylon rack (optionally with steel reinforcement) – attached to the gate using self-tapping screws through the mounting holes. Ideal for relatively light, short gates. The steel pinion running against the nylon rack ensures quiet operation. |
![]() |
Steel rack – attached to the gate by welding on threaded brackets, which the rack is then screwed into. Used for longer and heavier gates. Friction between the steel pinion and steel rack makes operation slightly noisier. |
The key requirement is that the operator pinion module is compatible with the rack module. Operator NICE Road RD400 has tooth module 4.
After installing the rack, check the clearance and set both limit-switch stops.
- Set the clearance along the entire travel path to 1–2 mm between the rack and pinion. The weight of the gate leaf must not rest on the operator.
- Move the gate leaf by hand toward the open position, stopping 2–3 cm before the mechanical stop. Slide the limit-switch bracket until it actuates, then move it at least another 2 cm in the opening direction, as specified by the manufacturer, and secure it.
- Set the closed position in the same way, in the opposite direction. The gate’s mechanical stops must remain functional.
- Tighten the fixing points and check that the gate moves freely along its entire travel path. Only then teach the end positions.
Clearance between the rack and pinion on the RD400. Click to enlarge the image.
Distance from the mechanical stop and additional bracket movement after actuation. Click to enlarge the image.
Wiring the NICE Road RD400 operator
Electrical wiring must be carried out by a qualified technician. Before changing wires, replacing fuses or connecting modules, disconnect the mains and any battery, and verify that the system is de-energised. Secure the gate to prevent unintended movement.
...to the mains
| Item | Meaning / procedure |
|---|---|
| L | Live conductor, as indicated on the mains terminal block. |
| N | Neutral conductor. |
| PE | Protective green-and-yellow conductor to the protective terminal; the operator is Class I and must be earthed. |
This RD400 version is powered by 230 V AC, 50/60 Hz. Never connect the mains supply to low-voltage terminals 1–8. An electrician must size the protective devices, isolation and supply cable for the installation.
...to the accessories
The terminal numbers apply to the described NICE RBA4R10 as marked on the board. Terminal 1 is +24 V and terminal 4 is GND.
| Item | Meaning / procedure |
|---|---|
| ANTENNA | Integrated receiver antenna input. The coaxial cable has a separate centre conductor and shield, as indicated by the symbol on the board. |
| 1–2 / SbS | Step-by-step control via a potential-free NO contact, for example the C–NO contact of a switch NICE EKS. |
| 3–4 / STOP | NO, NC or 8.2 kΩ, depending on the wiring. The type is learned during end-position learning; a change in the learned state triggers STOP with a brief reverse movement. |
| 1–5 / PHOTO | Photocell safety NC contact. If triggered while closing, the gate reverses direction. |
| 4–6 / PHOTOTEST | Separate TX power supply during the photocell test, max. 100 mA. RX remains connected to 1–4. |
| 7–8 / FLASH | Output for one warning light NICE ELDC; switches at 0.5-second intervals while moving. |
| 1–4 / accessories | 24 V DC power supply, tolerance −30% / +50%; external devices draw no more than 100 mA. |
Connect multiple NC STOP contacts in series and multiple NO contacts in parallel. Resistive safety edges require the specified cascading connection with a single 8.2 kΩ termination resistor. Do not bypass safety inputs as a way to resolve a fault. After changing devices, repeat the learning procedure and safety tests.
Drive fuses
| Item | Meaning / procedure |
|---|---|
| F1 | T 1 A / 250 V – time-delay fuse. |
| F2 | T 2 A / 250 V – time-delay fuse. |
Location of fuses F1 and F2 in the RD400 drive. Click to enlarge the image.
Replace a fuse with one of the same type only after identifying the cause of the fault. Do not increase the rating or bypass the fuse.
Standard wiring diagram:
Wiring of one pair of EPM relay photocells without photocell testing for RD400 with an RBA4R10 board from 01/2018. Flashing light ELDC has separate FLASH and antenna connections; the EKS switch controls the SbS input via the C–NO contact. A dot indicates an electrical connection; crossings without a dot are not connected. Line colors distinguish circuits; they do not indicate wire colors. Click to enlarge the image.
| Device | Connection to RD400 / RBA4R10 |
|---|---|
| ELDC – flashing light | Two-pin FLASH to terminals 7–8. Connect the antenna separately using RG58 coaxial cable to the antenna input: connect the core and shield according to the markings. |
| EPM – TX transmitter | TX 1 (+) → RD400 1; TX 2 (−) → RD400 4. |
| EPM – RX receiver | RX 1 (+) and 4 (C) → RD400 1; RX 2 (−) → RD400 4; RX 5 (NC) → RD400 5. RX 3 (NO) is left unconnected. |
| EKS – key switch | One contact: C → RD400 1, NO → RD400 2 (SbS). NC and the second contact are not used in this wiring configuration. |
| STOP and photocell testing | STOP between 3–4 is handled according to the safety devices; the diagram does not specify a universal jumper. Terminal 6 is unused here. For wiring with photocell testing follow the procedure below. |
Drive photocells
The example is for NICE EPM: TX is the transmitter and RX is the receiver. EPM has TX 1 = +, 2 = − and RX 1 = +, 2 = −, 4 = C, 5 = NC; RX 3 (NO) is not used in the safety circuit. For other photocell models, check their own terminal numbering.
Wiring without the photocell test function
Check the total current draw of the photocells. Output 1–4 supplies a maximum of 100 mA. One EPM pair draws approximately 55 mA; two pairs without photocell testing would draw approximately 110 mA in total, exceeding this limit. Therefore, connecting the NC contacts in series alone is not sufficient to connect an additional pair. A technician must plan the power supply for multiple pairs according to their actual current draw and instructions.
Both photocells are continuously powered from terminals 1–4. Connect the receiver’s C–NC safety contact between terminals 1 and 5 of the control unit.
| Control unit | EPM photocells |
|---|---|
| RD400 1 (+24 V) | TX 1 and RX 1; also RX 4 (C). |
| RD400 4 (GND) | TX 2 and RX 2. |
| RD400 5 (PHOTO) | RX 5 (NC). |
| RX 3 (NO) | Leave unconnected. |
This wiring matches the main diagram above. After wiring, check the photocell alignment and the gate’s response when the beam is interrupted.
Wiring with the photocell test function
With photocell testing, the transmitter’s power supply is changed: TX 1 goes to RD400 6 and TX 2 to RD400 4. RX and the C–NC contact remain as in the wiring without photocell testing. The safety circuit response is tested before movement begins.
Wiring with photocell testing: TX power supply is connected to terminals 6–4. Click to enlarge the image.
| Item | Meaning / procedure |
|---|---|
| TX 1 / TX 2 | RD400 6 / RD400 4; maximum 100 mA total at the PHOTOTEST output. |
| RX 1 / RX 2 | RD400 1 / RD400 4. |
| RX 4 (C) / RX 5 (NC) | RD400 1 / RD400 5. |
The mode of the connected safety devices is detected during position learning. After changing the wiring, repeat the learning procedure and verify that movement does not start if the test fails.
Synchronizing multiple pairs is a separate photocell function. Do not change the SYNC jumper automatically when enabling photocell testing: its use must match the instructions for the specific photocells and their power supply type. EPM describes synchronization for AC power, while the RD400 supplies DC here.
Selecting the gate’s direction of travel
Determine the direction while facing the gate from the drive side. For opening to the left, set the switch to the left; for opening to the right, set it to the right.
Left-hand opening, viewed from the drive side. Click to enlarge the image.
Right-hand opening, viewed from the drive side. Click to enlarge the image.
Do not change the switch while the gate is moving. Disconnect the power before working on the open drive; after changing the direction, check the limit-position learning again.
Assessing the gate leaf length
The learning process detects the limit positions, the STOP connection and the photocell test mode. Repeat it after changing the stops or safety devices. The movement area must remain clear.
- Release the drive, move the gate to approximately halfway, then re-engage the mechanical lock. Check the direction switch.
- Switch on the power. When idle, the motor is stopped, the green OK LED flashes approximately once per second, and the warning light is off.
- Press and hold Close + Stop/Set; release the buttons when movement starts after approximately 3 seconds.
- The first movement must be closing. If the gate opens, stop the learning process with Stop/Set, disconnect the power and check the direction.
- Allow the cycle to finish closing → opening → closing. L2 and L3 flash during learning.
- When learning is complete, issue an SbS command to open the gate fully, then issue another command to close it fully. During this test cycle, check that the gate slows down approximately 30–50 cm before the limit switches and stops 2–3 cm before the mechanical stops.
If L2 and L3 are still flashing after learning is complete, the learning process was unsuccessful. Check the wiring and diagnostics, resolve the cause and repeat the learning process.
Drive programming
The Road drive allows you to program several functions, either by switching a function on or off using Level I programming., or by setting a preset parameter using Level II programming.
The control board has four buttons and four programming LEDs. On this generation, programming is accessed by holding Set for approximately 3 seconds.
| Item | Meaning / procedure |
|---|---|
| Open ▲ | Opens the gate; in the menu, moves the selection up. |
| Stop/Set | Stops the gate; holding for approximately 3 seconds opens the menu. |
| Close ▼ | Closes the gate; in the menu, moves the selection down. |
| Radio | Stores and deletes remote controls; indicated by LED L4(R). |
Control board buttons and LEDs. L4(R) belongs to the radio receiver. Click to enlarge the image.
Level I programming.
The default setting for all three Level I functions is OFF. A short flash when a function is selected means OFF; a long flash means ON.
- Hold Set for approximately 3 seconds and release it when L1 flashes.
- Use Open / Close to select the function LED.
- Briefly press Set to toggle OFF / ON. Adjust another function if needed.
- Programming ends after 10 seconds without a button press, and the changes are saved.
List of programmable on/off functions:
| Item | Meaning / procedure |
|---|---|
| L1 – deceleration length | OFF = short deceleration; ON = long deceleration. |
| L2 – speed | OFF = slow; ON = fast. |
| L3 – automatic closing | OFF = disabled; ON = enabled. The pause time is selected in Level II; the factory setting is 30 s. |
Level II programming.
Level II sets the parameter value. The parameter and its value are selected using the same LEDs in two successive steps.
- Hold Set for approximately 3 seconds and release it when L1 flashes.
- Use Open / Close to select parameter L1, L2 or L3.
- Press and hold Set. After approximately 3 seconds, the LED for the current value lights up.
- Keep holding Set and use Open / Close to select a new value; then release Set.
- The menu closes after 10 seconds without a button press.
List of programmable adjustable functions:
| Item | Meaning / procedure |
|---|---|
| L1 – motor force | L1 low; L2 medium; L3 high (factory setting). |
| L2 – SbS step sequence | L1 open–stop–close–open (factory setting); L2 open–stop–close–stop; L3 condominium mode. |
| L3 – pause time | L1 15 s; L2 30 s (factory setting); L3 60 s. Applies when automatic closing is enabled. |
Do not compensate for mechanical resistance in the gate by increasing the force. After changing the force, repeat the relevant measurements and safety tests.
Connecting additional external devices to the drive
| Item | Meaning / procedure |
|---|---|
| Accessory power supply | Between 1 (+) and 4 (GND), 24 V DC with a tolerance of −30% / +50%, maximum total current 100 mA. |
| Control contact | Separate potential-free NO contact on 1–2 (SbS). Do not apply an external voltage to the input. |
Drive special functions
Keeping the gate open
If the SbS command is held for longer than 3 seconds, the gate opens regardless of the selected step sequence. This can be used with a suitable timed contact to keep the gate open for a specified period.
Forced operation
In the event of a safety device failure, the manufacturer describes emergency operation with the control held continuously. Use it only when you have a clear view of the gate, the area is clear and no one is at risk. The fault must be repaired as soon as possible.
- Issue a command. If movement does not start because a safety device is blocking it, issue the command again within 3 seconds and hold it.
- After approximately 2 seconds, the gate will move only while the command is held.
- Releasing the control stops the gate immediately. This mode does not replace repair of the safety devices.
Troubleshooting the drive
If anything is unclear or you have any other problem, please feel free to contact our technical support team for NICE drives.
Depending on the nature of the problem
During installation (or if the drive fails), you may encounter one of the following problems:
| Item | Meaning / procedure |
|---|---|
| Remote control does not light up | Check its battery. |
| Remote control lights up, but the gate does not respond | Check that the remote control is stored correctly and uses the correct protocol; check the antenna and whether the memory is blocked. |
| OK LED is off | An electrician should check the power supply and fuses after safely disconnecting the power. |
| The command is received, but movement does not start | Note the red OK flashes or the beacon’s flash sequence; check PHOTO, STOP, and active commands. |
| Movement immediately reverses | Check for obstructions, friction, the rack, and the limit switch. Adjust the force only after checking the mechanism, then verify safety again. |
Diagnostics using beacon flashes
During normal operation, the beacon flashes at 0.5-second intervals. In the event of a fault, count the flashes in each sequence, separated by a pause of about one second. The red OK LED signals the same faults.
| Number of flashes | Meaning and checks |
|---|---|
| 2 | The photocell is blocking movement. Check for obstructions, alignment, power supply, and the safety contact. |
| 3 | Force limiter activated. Find the cause of excessive friction or an obstruction. |
| 4 | STOP activated. Check the safety device and wiring. |
| 5 | Internal parameter error. Wait at least 30 s; if the fault persists, a technician should reset the system and run the learning procedure again. |
| 6 | Duty cycle exceeded. Let the operator rest for a few minutes. |
| 7 | Internal electrical fault. A technician should disconnect all power sources for a few seconds; if the fault recurs, check the control board and motor wiring. |
| 8 | Another continuous command is already active. Check the button, relay, or timer. |
| 10 | Movement time exceeded or no motor power during the learning procedure. Check the mechanism and movement time, and make sure the control board is correctly seated in its holder. |
Diagnostics using LED flashes
This control board has an OK, not a BlueBUS LED. The STOP LED indicates the status of the safety input; settings and radio are indicated by LEDs L1, L2, L3, L4(R). Their locations are shown in the button diagram.
Horizontal LEDs: OK, STOP
| Item | Meaning / action |
|---|---|
| OK – green, once per second | Normal operation. |
| OK – 2 quick green flashes | Input change or command received. |
| OK – red flash sequence | Fault indicated by the flash code table. |
| OK – continuously green or red | Fault condition; if it recurs after disconnecting the power and checking the system, service is required. |
| OK – off | Check the power supply and fuses. |
| STOP on / off | On: input status is OK. Off: STOP activated; check the device and its learned status. |
LEDs L1–L4(R) by the buttons
| Item | Meaning / action |
|---|---|
| L1 | Off = short slowdown; on = long slowdown. |
| L2 | Off = slow speed; on = fast speed. |
| L3 | Off = automatic closing disabled; on = enabled. |
| L1 + L2 + L3 flashing | Position learning is required; follow the relevant procedure during programming. |
| L4(R) on | An unprogrammed radio code was received during normal operation. |
| L4(R) flashing | Remotes are being programmed or deleted. |
Manual release of the NICE Road RD400 operator
In the event of a power failure or fault, the RD400 can be released using the supplied key so the gate can be operated manually. First, prevent unintended movement and disconnect the power sources. If the gate leaf moves by itself or sticks after release, it needs repair.
The left side of the image shows how to release the RD400; the right side shows how to re-engage it. Click the image to enlarge it.
- Open the lock cover, insert and turn the key, then fold out the release handle as shown.
- Move the gate slowly and carefully by hand.
- To re-engage the operator, fold the handle back, turn and remove the key, then close the cover. Check that the mechanism has engaged before operating the gate automatically.
NICE Road RD400 operator specifications
| Item | Meaning / action |
|---|---|
| Application / limits | Residential sliding gates, up to 400 kg and 8 m, depending on the duty cycle. |
| Motor / power supply | Electromechanical operator with built-in control unit; RD400 mains supply: 230 V AC, 50/60 Hz. RD400/V1 is a different voltage version. |
| Max. power consumption / current | 210 W / 1.1 A. |
| Torque | Starting: 12 Nm (400 N); rated: 5 Nm (167 N). |
| Speed | No load: 0.13 or 0.25 m/s; at rated torque: 0.16 m/s. |
| Pinion | Z15, module 4, pitch 12.5 mm, pitch diameter 60 mm. |
| Operation | Max. 50 cycles per day, continuous operation for a maximum of 9 min; thereafter, limitations apply depending on length and weight. |
| Fuses / protection | F1 T 1 A / 250 V; F2 T 2 A / 250 V; Class I, protective earthing. |
| Beacon / battery | One NICE ELDC; optional NICE PS124. |
| Functions | 3 ON/OFF functions and 3 adjustable parameters. STOP and position learning. |
| Operating temperature / protection | −20 to +55 °C; IP44. |
| Dimensions / weight | 330 × 195 × 277 mm; 8 kg. |
Specifications of the NICE Road RD400 operator’s built-in radio receiver
| Item | Meaning / action |
|---|---|
| Receiver | Built-in, 4 commands, 433.92 MHz. |
| Protocols | FloR, O-Code, Smilo. The first programmed remote determines the family for subsequent remotes. |
| Memory | Up to 100 transmitters can be stored in Mode I. |
| Antenna / sensitivity | 52 Ω, RG58 or equivalent cable; sensitivity better than 0.5 µV. |
| Range | The manufacturer specifies 100–150 m; obstacles, interference and antenna placement affect the range. |
| Temperature | −20 to +55 °C. |
Storing remote controls
These instructions are for the integrated receiver on the four-button control board described. Choose a remote control with a supported protocol, such as NICE ON2E or NICE FLO2RE, depending on the family in use. Pairing does not require clearing the gate travel limits.
Mode I – entire remote control
- Hold down Radio for at least 5 s, then release it when LED L4(R) lights up.
- Within 10 s, hold down the first button on the remote control for at least 5 s, then release it.
- Three flashes of L4(R) confirm that it has been stored. The mode ends after 10 s if nothing else is stored.
T1 = SbS, T2 = pedestrian opening, T3 = open, T4 = close; a two-button remote control has only T1 and T2.
Mode II – one button
- Briefly press Radio once for SbS, twice for pedestrian opening, three times to open or four times to close.
- Check that L4(R) flashes the corresponding number of times.
- Within 10 s, hold down the desired remote-control button for at least 3 s; three flashes confirm that it has been stored.
You can compare other receivers and procedures in our NICE remote control pairing guide. If the remote control cannot be stored, also check whether the radio memory is locked.
Control unit reset
Resetting is intended to deliberately erase settings; it is not a mandatory first step. With the motor stopped, hold down Open + Close for approximately 3 s. When all the LEDs light up, release the buttons. When finished, L1, L2 and L3 flash. The limits, settings and safety tests must be taught and checked again. This procedure does not erase stored remote controls.
Backup battery and service interface
The optional battery intended for this generation of RD400 is the NICE PS124 with a capacity of 1.2 Ah and integrated charging. Connect it only after installation and programming are complete, with the mains power disconnected. Once connected, the operator is powered even when the mains supply is off. Battery life depends on the operator load and battery condition.
Service programmer NICE OVIEW connects via NICE IBT4N to BusT4. Insert the interface with all power sources disconnected.
Testing, handover and maintenance
- Check opening, closing, stopping, slow-down and both limit switches.
- Test each pair of photocells, every STOP device and the phototest, if used.
- Check the forces and carry out the measurements required for the specific gate; excessive force must not be used to compensate for a mechanical fault.
- Check the release mechanism, covers, safety devices and labels. Give the user the operating instructions and maintenance schedule.
A technician must perform maintenance at least every 6 months or after no more than 10,000 movements since the last service. The user must keep the area and photocells clean and stop using the automation if unusual noises or jerky movement occur. When cleaning the gate track, disconnect any battery as well. Watch the gate from a safe distance while it is moving. Pass through only once the gate is fully open and stationary. Children must not operate the gate or play near it.