NICE Walky WL1024C – gate operator with control unit for gates up to 1.8 m/180 kg
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€352.28 including VAT
| Weight |
|---|
| 4,80 kg |
Description of NICE Walky WL1024C – gate operator with control unit for gates up to 1.8 m/180 kg
NICE WALKY WL1024C is an articulated-arm operator for one leaf of a swing gate with an integrated WLA1 control unit. The motor runs on 24 V DC, the complete WL1024C is powered from a 230 V AC. For a double-leaf gate, connect a second WL1024 motor without a control unit.
The operator is irreversible and can be released with a key in the event of a power failure. The values 1.8 m and 180 kg are separate maximum limits; suitability for a specific gate is determined by the combined length-and-weight graph.
| Quick navigation | |
|---|---|
| Selection and limits | Accessories |
| Kits | Installation |
| Wiring | Terminals and polarity |
| Photocells | Initial setup |
| Settings | Remote controls |
| Faults | Manual release |
| Reset | Maintenance |
| Specifications | PDF manual |
Control unit and compatible accessories
The WLA1 is included with the WL1024C. A standalone WLA1 serves as a replacement unit. The WL1024 is a second motor without its own controller; no second control unit is needed. The following procedures apply to the WLA1 with four LEDs L1–L4; check the markings and controls on the installed board before working on it.
| What | Why | Type |
|---|---|---|
| Second motor | For the second leaf; separate motor cable. | |
| Photocells | Passageway protection, polarity-free BlueBUS. | |
| Warning light | Signals that the gate is moving; FLASH connector and flashing-light function. | |
| Radio receiver and remote control | SM plug-in receiver and compatible coding; selection and pairing. | |
| Backup battery | Gate operation during a power outage; dedicated connector. | |
| Solar power supply | For locations without mains power; do not connect to the mains power supply. |
Kits for one or two leaves
A standalone WL1024C operates one leaf. For a double-leaf gate, it also controls a second NICE WL1024 motor without its own control unit. Choose the number of motors and accessories according to the specific kit. Two motors do not increase the limit for a single leaf.
| 1 leaf | Standalone operator | 2 leaves |
|---|---|---|
| Basic kit With photocells With accessories ![]() | Standalone WL1024C![]() One motor with WLA1 control unit; accessories must be added. | Basic kit With photocells With accessories ![]() |
When to choose the WALKY WL1024C
Suitable for lighter swing gates with enough clearance for the articulated arm. The leaf must move smoothly and remain stationary when released. The operator will not fix damaged hinges, friction, or wind acting on a solid infill.
| Condition | Single-leaf limit |
|---|---|
| Full arm | Maximum length 1.8 m at a maximum weight of 100 kg; opens up to 110°, depending on the geometry. |
| Maximum weight | 180 kg at a length of 0.8 m with the full arm. Longer leaves must comply with the combined chart. |
| Shortened arm | Maximum length 1.6 m at a maximum weight of 100 kg; opens up to 90°. |
| Leaf height | Maximum 2 m with either the full or shortened arm. |
| Operation | Maximum 100 complete cycles per day; the control unit limits operation to approximately 50 cycles per hour. Approximately 10 minutes of continuous operation, followed by a required break. |

WALKY operating chart: leaf length in m on the horizontal axis, weight in kg on the vertical axis; shaded areas for the full and shortened arms
The intersection of the weight and length values must fall within the relevant shaded area. Infill area, wind, hinge dimensions, and installation dimensions must also be taken into account. If you need help checking your selection, contact us with the gate dimensions, weight, and photos.
Estimated service life
Determine the load index from the combined length and weight range, then add the effects of the environment. The chart gives an estimated number of cycles, not a guarantee or a number of years.
If the weight falls exactly on the boundary between ranges, use the higher of the two adjacent indices when assessing the safety margin. The service life index does not replace the operator suitability chart.
Installing the operator and articulated arm
Disconnect both the mains supply and the battery before working on the unit. At both the open and closed positions, rigid mechanical stopsare required; they are not automatically included with the operator.
Arm clearance and dimensions A / B / E
| Dimension | Condition |
|---|---|
| Pillar width | At least 80 mm. For a width of 80–135 mm, install the rear bracket rotated 90°, as shown. This refers to the width of the mounting area, not the overall pillar cross-section. |
| Clearance E | 80–299 mm: the arm must be shortened; maximum opening angle 90°. 300 mm or more: use the full arm; opening angle up to 110°, depending on the geometry. |
| A and B with the full arm | Measure the hinge and bracket positions according to the drawing. Point A/B must fall within the shaded area of the chart for the required opening angle. |
| Positioning | Install the motor vertically, with the arm at the top of the leaf. Do not install the operator upside down with the arm pointing downwards. |

WALKY: measuring clearance E behind the articulated arm

WALKY with full arm: dimensions A and B in mm and chart for 90–110° opening
Mounting the brackets and full arm
- Assemble the arm and rear bracket according to the drawing. The bent section of the arm faces the gate; the pins and retaining rings must be correctly seated.
- Mark the motor position according to dimensions A/B. Anchor the rear bracket to a load-bearing substrate; select suitable anchors and check the strength of the structure.
- Install the motor vertically. With the motor released and the gate closed, determine the position of the front bracket on the leaf; follow the height arrangement, including the 75 mm check dimension shown in the drawing.
- Fasten the front bracket to the solid frame of the leaf. First, allow for its position to be adjusted. Manually check the full travel, free movement of the arm, and contact with both stops.
- Once the closed leaf has been adjusted, permanently fasten the bracket with all three screws. Secure the arm with the pin and retaining ring.

WALKY: arm assembly, rear bracket, and position of dimension B

WALKY: pillar mounting, leaf bracket height, and final securing of the arm

WALKY on a pillar 80–135 mm wide: rear bracket rotated 90°
Installing with the shortened arm
Shortening the arm is an installation modification required when clearance E is under 300 mm. First, check the limits of the shortened arm and the geometry. Dimension C is the distance between the arm pivot-pin axes; determine it from the A/B intersection on the chart. Do not cut the shortened section by guesswork.
- Use dimensions A/B to select C from the chart; the maximum opening angle is 90°.
- Before cutting, assemble the arm in the test position. With the gate both closed and open, use a string as shown in illustration AA/BB to check the bracket position and hinge axis.
- Only after confirming the full travel, adjust the length according to the drawing, remove any sharp edges, and complete the fastening.
- Recheck the stops and free movement, and make sure the arm does not collide with the pillar or gate leaf.

WALKY: dimensions A, B, and C and chart for the shortened arm with opening up to 90°

WALKY: setting C and checking the hinge axis in positions AA and BB

WALKY: shortening and completing arm installation after checking the geometry
WLA1 control unit wiring
The WL1024C motor includes the WLA1 control unit and a mains power supply module. Separate the mains and signal cables; use cable glands, seals, and all cover screws. The cables must not obstruct the cover or cover the LEDs.
Wiring and maximum cable lengths
| Cable run | Cable / maximum length |
|---|---|
| 230 V AC mains | 3 × 1.5 mm² / 30 m. For lengths over 30 m, use 3 × 2.5 mm² and protective earthing at the automation system. |
| ELS electric lock | 2 × 1 mm² / 6 m. |
| BlueBUS | 2 × 0.5 mm² / 20 m; for 20–40 m, use 2 × 1 mm². |
| Key switch | Two cable runs, 2 × 0.5 mm² / 50 m; one 4 × 0.5 mm² cable run is also possible. |
| Second WL1024 motor | 3 × 1.5 mm² / 6 m. |
| Antenna | RG58 / max. 20 m; less than 5 m recommended. |
Mains power supply and earthing
Connect the live wire L and the neutral wire N as shown on the power supply module label. The protective conductor PE must be connected to the marked earthing terminal. The isolator must allow the entire automation system to be safely disconnected; disconnect the battery separately.

WALKY: access to the mains module and protective earth
WLA1 board orientation

WLA1: connectors, JA/JB jumpers, buttons, and LEDs; numbers correspond to the table
| Number in the illustration | Component |
|---|---|
| 1 / 2 / 3 | Battery or Solemyo connector / fuse / motor connector. |
| 4 / 5 / 6 / 7 | L1 / L2 / L3 / L4 programming LEDs. |
| 8 / 9 | SM receiver socket / BusT4 interface. |
| 10 / 11 | JA / JB jumpers for gate configuration. |
| 12 / 13 / 14 | P.P. / STOP / BlueBUS LEDs. |
Accessory terminals and polarity
| Terminal / connector | Use |
|---|---|
| BlueBUS | Two-wire power supply and communication for compatible devices, no polarity. Not a general-purpose 24 V output. |
| P.P. | Volt-free NO contact for step-by-step operation; the contact itself has no polarity. |
| STOP | Learned safety input, NO, NC, or 8.2 kΩ. A change in the idle state stops movement and causes a brief reversal. |
| Auxiliary + / − | The plus (+) is the marked left-hand P.P. terminal, and the minus (−) is the marked left-hand STOP terminal, as oriented in the detail below. With mains or Solemyo power: 18–31 V DC; with PS424: approximately 11–14 V DC, up to 200 mA total. Remains active in standby. |
| ELS | Factory-fitted electric lock 12 V AC, max. 15 VA; AC voltage has no plus/minus polarity. A different operating mode requires Oview configuration. |
| FLASH on the power supply module | WLT or 12 V DC lamp up to 21 W; dedicated connector and flashing-light function. Do not confuse with ELS or the auxiliary power supply. |
| SM / BusT4 | Plug-in receiver / service interface; not accessory power terminals. |
| Antenna | Coaxial cable signal and shield; not a power +/− connection. |

WLA1: detail of the P.P., STOP, BlueBUS, ELS, and second motor terminals

WLA1: auxiliary plus at P.P. and minus at STOP; orientation as shown in the detail
Second WL1024 motor
Motor without a control unit NICE WL1024 connect to the designated three-pole motor terminal block. The two outer wires are motor wires; the center terminal, marked with the earth symbol, is PE, not negative. The polarity at the motor output changes depending on the direction; it is not a power source for accessories. The integrated motor connects via its own connector, which has only one correct orientation. Before learning, set JA/JB according to the complete system.
BlueBUS photocells and addresses
NICE EPMB connect in parallel to BlueBUS using two wires with no polarity. TX and RX of each pair must have the same jumpers; each pair must have a different address. After each change, repeat device learning. Relay photocells must not be connected directly to BlueBUS.
| Address | Function on WALKY |
|---|---|
| FOTO / FOTO II | Pairs active during closing; they stop and reverse movement. |
| FOTO 1 / FOTO 1 II | Pairs active during both opening and closing. |
| FOTO 2 / FOTO 2 II | Pairs active during opening; they stop and reverse movement. |
| FA1 / FA2 | Opening command; not a substitute for a safety pair. On supported TX and RX units, remove jumper A. |
| BlueBUS capacity | Maximum 15 units: up to 6 safety pairs, 2 pairs with an opening function, and 4 supported command devices. |
Set the exact jumper positions according to the EPMB photocell instructions for the selected address. Choose the pair position according to the area being protected; after learning, check each pair's response during actual opening and closing.

WALKY: positions of the FOTO, FOTO II, FOTO 1, FOTO 1 II, FOTO 2 and FOTO 2 II pairs
FOTO 3 is not a valid address on the WLA1. Do not transfer the addressing from another drive.
STOP safety input
Connect NO contacts in parallel and NC contacts in series. Two supported 8.2 kΩ resistive devices can be connected in parallel; for more than two, use the specified cascaded wiring with a single terminating resistor. Plan mixed NO/NC/resistive wiring according to the instructions. The control unit stores the idle state during learning; after any change, it must be taught again and tested. Do not use a resistor to disable the required gate protection.
WLT warning light and ELS output
NICE WLT can be fitted on top of the WL1024C and connected to the designated connector Power module FLASH. In flashing-light mode, it should flash 0.5 s on / 0.5 s off while the gate is moving. WLT also functions as a courtesy or dusk light; select the required function according to its instructions.
If WLT is installed separately, away from the drive, connect it to ELS, whose function must be changed via Oview. The factory-set ELS is an output for a lock, not a warning light. Do not reverse the WLT connector or determine polarity based on P.P./STOP.
| Selected function | Output electrical limit |
|---|---|
| Electric lock | 12 V AC / max. 15 VA, non-polarized. |
| Flashing light | WLT or 12 V DC lamp / max. 21 W. |
| Other lamp or relay | With a 24 V DC supply, −30% / +30%, max. 4 W; with PS424, 12 V DC −10% / +25%, max. 4 W. Check the settings and compatibility before connecting. |
PS424 backup battery
NICE PS424 is not automatically included with the motor. Connect it to the designated connector only after installation, learning and testing are complete. In the event of a power failure, the auxiliary output voltage drops. The number of operations depends on the gate, power consumption and battery condition.

WALKY: plug-in SM receiver and installation of the PS424 backup battery
Solemyo and service interface
NICE Solemyo uses the same designated connector as the backup power supply. When using Solemyo, the mains power supply must not be connected at the same time. Configure power consumption reduction and the solar kit according to the system. Oview connects to BusT4 and enables additional settings and diagnostics. The BlueBUS Stand-by setting via L4 is not the same as the Stand-by All function via Oview.
Initial startup and learning
Keep people out of the gate area. After switching on, BlueBUS should flash once per second, the TX/RX photocells should indicate operation, and the warning light should be off when idle. If the status is incorrect, disconnect the power and check the wiring. Learning is not a safety test.
1. BlueBUS and STOP learning
- Press and hold OPEN + STOP/SET for approximately 3 s.
- Release when L1 and L2 flash rapidly.
- Wait for the process to finish. The STOP LED should be on and L1/L2 should be off; L3/L4 may start flashing to prompt position learning.
Perform learning even with no accessories connected. Repeat it each time a device is added or removed.
2. JA / JB according to the configuration and leaf sequence
Before learning, select the exact configuration shown in the diagram: motor with control unit position, one or two leaves, and any leaf overlap. The black block indicates the control unit; the arrow indicates the overlapping leaf. Set the JA/JB jumpers exactly as shown in the corresponding row; do not choose a position based only on the label “left-hand motor” without checking the diagram orientation.

WALKY: eight gate configurations and the corresponding JA and JB jumper positions
3. Mechanical stop learning
- Check that fixed stops are in place for both opening and closing. Unlock the motors, move the leaves to approximately the midpoint of their travel, then lock them again.
- Press and hold STOP/SET + CLOSE for approximately 3 s; release when L3/L4 flash rapidly.
- Watch the sequence: slow closing of M1, slow closing of M2, slow opening of M2 and M1, then full-speed closing of both. With one motor, the corresponding single-leaf sequence is performed.
- If the first movement is not towards closing, or M1 does not start closing first, stop by pressing any button. With the power disconnected, check JA/JB and, if necessary, the polarity of the WL1024 motor wires.
- Successful completion is confirmed when L3/L4 go out. If a photocell, command or other device is activated, learning is interrupted and the entire process must be repeated.
Then perform several full opening and closing cycles. Check startup, normal speed, deceleration, stopping at the stops and safety tests.
WLA1 programming – four LEDs, L1 to L4
OPEN opens, CLOSE closes and STOP/SET stops; during settings, OPEN/CLOSE select the LEDs. Changing the force or speed requires retesting the movement and impact forces. Do not compensate for hinge faults by increasing the force.
Level I – ON / OFF functions
- Press and hold STOP/SET for approximately 3 s, then release when L1 flashes.
- Use OPEN/CLOSE to select the function LED.
- Press SET briefly. A short flash indicates OFF; a long flash indicates ON.
- If no button is pressed for 10 s, the mode exits and the changes are saved.
| LED – function | Operation and factory setting |
|---|---|
| L1 – Automatic closing | ON: after opening, the gate closes after the time set in II/L1. OFF: waits for a command. Factory setting: OFF. |
| L2 – Close after photocell activation | ON: if a photocell is activated during opening or closing, the pause is reduced to 5 s. If automatic closing is off and a photocell is activated during closing, closing after the programmed pause is activated. OFF: this function is not used. Factory setting: OFF. |
| L3 – Always close | ON: if power returns while the gate is open, it closes after a 5 s pre-flashing period. OFF: when mains power returns, the gate remains in its original state. Factory setting: OFF. |
| L4 – BlueBUS Stand-by | ON: one minute after movement, BlueBUS and the standard LEDs switch off; BlueBUS flashes slowly. A new command restores operation after a short delay. OFF: this energy-saving mode is disabled. Factory setting: OFF. |
Level II – adjustable parameters
- Press and hold SET for approximately 3 s, release when L1 flashes, then use OPEN/CLOSE to select the parameter’s input LED.
- Press and hold SET and wait approximately 3 s for the current value LED to light up.
- While continuing to hold SET, select the value using OPEN/CLOSE.
- Release SET and wait 10 s. Bold values are the factory settings.
| Input LED – name and description | LED settings – value |
|---|---|
| L1 – Pause time Effective when automatic closing is ON. | L1 – 5 s L2 – 30 s L3 – 60 s L4 – 120 s |
| L2 – Step-by-step (P.P.) Sequence of commands from the input and radio control. | L1 – Open – stop – close – stop L2 – Open – stop – close – open L3 – Open – close – open – close L4 – Condominium mode |
| L3 – Motor speed Normal movement speed. After changing the setting, check movement and safety. | L1 – Slow L2 – Medium L3 – Fast L4 – Very fast |
| L4 – Motor force Sets both motors; after changing the setting, measure impact forces. | L1 – Level 1 – minimum L2 – Level 2 L3 – Level 3 L4 – Level 4 – maximum |
In condominium mode II/L2 → L4, P.P. and Open commands are ignored while opening; Close reverses the movement. While closing, P.P. and Open reverse the movement to opening; Close is ignored. Do not confuse the parameter input LED with the LED for the selected value.
Receiver and remote controls
The radio receiver is plugged into the socket SM with the mains and battery disconnected. Before pairing, check the type of receiver installed and the remote control’s coding. The equipment supplied with a standalone motor may differ from that supplied with a complete kit.
For NICE OXIBD select a compatible remote control, such as NICE MYGO4. An existing SMXI or OXI may use different coding. Matching frequency of 433.92 MHz is not enough.
| Mode | Commands |
|---|---|
| Mode 1 | Output 1 – step-by-step; 2 – partial opening 1; 3 – open; 4 – close. |
| Mode 2 | A single button is assigned to the selected supported command. Advanced commands require a compatible receiver. |
Pairing, deleting a button, and clearing the radio memory must be carried out according to the instructions for the installed OXIBD receiver. Resetting WLA1 does not replace clearing the plug-in receiver’s radio memory. Connect the OXIBD antenna according to its antenna connector.
Troubleshooting – what to check when a fault occurs
The warning light repeats a short series of flashes after a 1-second pause. Count the flashes in one series before looking for the cause. Do not bypass a safety device to disable it.
| Flashes | Cause and solution |
|---|---|
| 1 | BlueBUS does not match the learned configuration. Check the cables, devices, and addresses; after changing them, repeat the learning procedure. |
| 2 | Photocell is blocking movement: remove the obstruction, clean and align the optics. |
| 3 | Increased resistance or force limit triggered: check the hinges, arm, and clear travel path; test the forces. |
| 4 | STOP status has changed: check the safety device and wiring. |
| 5 | Internal parameter error: wait at least 30 s, then try a command; if the error persists, disconnect the power and contact a qualified service technician. |
| 6 | Movement limit exceeded: wait a few minutes for the operating limit to reset. |
| 7 | Electrical fault: wait at least 30 s; if it persists, disconnect all power sources and check the control board and cables. |
| 8 | A continuous command is blocking another command: check for a stuck switch or P.P. timer contact. |
| 9 | Automation electronically locked: an unlock command is required; this is not a manual key release. |
| LED at rest | Meaning |
|---|---|
| BlueBUS flashes once per second | Normal operation; 2 quick flashes confirm an input change or a received command. |
| BlueBUS off / continuously lit | Check the power supply, fuse, and control unit; the indicator changes in standby. |
| STOP is lit | The learned safety input is in its normal state. |
| STOP is off | Check the safety input; its status does not match the learned configuration. |
| L1 + L2 flash slowly | Devices need to be learned. |
| L3 + L4 flash slowly | The limit positions need to be learned. |
Emergency movement in hold-to-run mode
If a safety device fails, first use the manual release. Use hold-to-run mode only when you have a clear view of the gate: issue a command, repeat it within 3 s and hold it; after about 2 s, the gate moves only while the command is held. The area must be clear and the entire gate must be visible. This does not replace repair of the safety device.
Manual release during a power outage
Release the gate only when it is stationary. In the event of a mechanical fault, dangerous movement, or strong wind, secure the gate leaf first.
- Lift the release cover and insert the key.
- Turn the key almost a full turn clockwise. You can move the gate leaf by hand.
- To re-engage the mechanism, turn the key counterclockwise and gently move the gate leaf until the mechanism engages.
- Remove the key. Turn the release disk 90° counterclockwise to cover the opening, then close the cover.

WALKY: A – release with the key; B – re-engage the drive
Clearing the WLA1 memory
A reset restores the factory settings and erases the unit’s learned data. With the gate stationary, hold down OPEN + CLOSE, until L1 and L2 start flashing. Then repeat the learning procedure for the devices and mechanical stops, and repeat the safety tests. The memory of the plug-in radio receiver is cleared using a separate receiver procedure.
Tests before handing over the gate
- With the drive disengaged, check the entire gate leaf: it must move smoothly by hand with a force of less than 390 N and remain stationary when released. This test does not measure motor torque or the permissible impact force.
- Check the anchors, brackets, screws, pins, retaining devices and both mechanical stops. Engage the motors.
- Test opening, closing and STOP from all control devices, including the leaf sequence and overlap.
- Test each photocell and safety edge separately in both directions of travel; verify the gate’s actual response.
- Measure impact forces with a force meter. Repeat the test after changing the force, speed or geometry.
- After successful testing, hand over the labelled gate with the release instructions and maintenance schedule. Do not walk between moving gate leaves.
Maintenance and safe use
Carry out an inspection at least every 6 months or 20,000 operating cycles, whichever comes first. Before servicing, disconnect the mains and the PS424 or Solemyo. Check for corrosion, secure fastening, joint play, pins, stops, cables and the release mechanism. Clean and test the photocells; repeat the safety tests after maintenance.
Do not compensate for a motor fault by increasing the force. If a fault occurs, stop using automatic operation and call for service. Take the motor, electronics and battery to an appropriate collection point, not to household waste.
WALKY WL1024C technical specifications
| Parameter | Value |
|---|---|
| Motor / control unit | 24 V DC / integrated WLA1. |
| WL1024C mains power supply | 230 V AC, +10% / −15%, 50/60 Hz. |
| Rated mains input | 120 W. |
| Speed | No-load: 0.20–0.30 rad/s; at rated torque: 0.16–0.24 rad/s. Not metres per second. |
| Gate leaf limits | Up to 1.8 m / 180 kg, according to the combined chart; max. height 2 m. |
| Operation | 100 complete cycles/day; approximately 50 cycles/hour and continuous operation for approximately 10 minutes. |
| BlueBUS | Up to 15 units; polarity-free connection. |
| Auxiliary power supply | Up to 200 mA; P.P./STOP voltage and polarity. |
| Protection rating / temperature | IP44 with the cover intact and closed; −20 to +50 °C. Performance decreases in cold weather. |
| Dimensions / weight | Approx. 90 × 125 × 385 mm / 4.8 kg. |
| Backup / solar power | NICE PS424 / NICE Solemyo depending on the selected power supply. |

WALKY dimensions and articulated arm position; drawing dimensions in mm
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]