NICE Walky WL1024 – gate opener without control unit for gates up to 1.8 m / 180 kg
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€603.60 including VAT
| Weight |
|---|
| 4,30 kg |
Description of NICE Walky WL1024 – gate opener without control unit for gates up to 1.8 m / 180 kg
NICE WALKY WL1024 is a 24 V DC articulated-arm motor without a control unit. It is designed as the second operator for a double-leaf gate and connects to NICE WALKY WL1024C, which includes the WLA1 control unit. The WL1024 itself has no receiver, programming buttons or mains power supply.
The operator is non-reversible; in the event of a power outage, the leaf can be released with a key and operated manually. Choose the leaf length and weight together according to the application chart.
Control unit and compatible accessories
All accessories connect to the WLA1 in the WL1024C motor. Only the cable from the control unit connects to the WL1024. For a single-leaf gate, choose the WL1024C; for a double-leaf gate, use one WL1024C and one WL1024.
| What | Why | Type |
|---|---|---|
| Control of the second leaf | Powers and controls both motors; sets their travel, force and speed. | |
| Photocells | Monitors the passage; connects using two wires with no polarity. | |
| Remote control | Plug-in receiver and compatible remote control; accessories for the standalone motor are sold separately. | |
| Warning light | Indicates movement. The WLT is installed on the WL1024C and connects to its FLASH connector. | |
| Backup power during an outage | The battery connects to the WL1024C and powers both motors. | |
| Solar power | Off-grid operation is possible, subject to an assessment of power consumption and site conditions. |
Motor, control unit or complete kit
| WL1024C | WL1024 | Double-leaf kits |
|---|---|---|
Motor with WLA1![]() For one leaf or as the control motor for a double-leaf gate. | Second motor without control unit![]() This product. Connects to the WL1024C; it cannot operate the gate on its own. | Basic kit With photocells With accessories ![]() |
Double-leaf kits include the WL1024C, WL1024, OXIBD receiver and MYGO4 remote control. The photocell version also includes EPMB; the accessories kit also includes WLT. Two motors do not increase the permitted length or weight of a single leaf.
Standalone motor package contents
The standalone WL1024 includes the motor, articulated arm with fasteners, mounting brackets and release keys. It does not include WLA1 or radio controls; control is provided by the WL1024C. Anchors suitable for the specific substrate and fixed gate stops must be provided as required for the installation.
When is the WALKY WL1024 suitable?
| Configuration | Use |
|---|---|
| Full arm | Gate leaf up to 1.8 m at 100 kg; up to 180 kg at 0.8 m. The angle depends on the geometry and is limited to 110°. |
| Shortened arm | Gate leaf up to 1.6 m at 100 kg; angle limited to 90°. For other combinations of length and weight, refer to the relevant area of the chart. |
| Gate leaf height | Maximum 2 m. A solid infill and wind increase the load. |
| Gate condition | Moves smoothly by hand in both directions, with no points of increased resistance. The gate leaf stays in position when released. |
| Use | Swing gate opening inward, with sufficient space for the arm to move. |
The values 1.8 m and 180 kg are separate maximum limits. The chart shows gate leaf length in metres horizontally and weight in kilograms vertically; the intersection must fall within the permitted grey area for the selected arm length. The white area is not permitted.
Load and estimated service life
Service life is affected by gate leaf length and weight, temperature, infill and wind. Add the index for length and weight to the indices for any other applicable factors. The chart shows an estimated number of cycles with maintenance, not a guaranteed number of years.
| Characteristics of the complete automation system | Index | Service life chart | |
|---|---|---|---|
| Full arm | Shortened arm | ||
| Gate leaf under 1.2 m; over 100 kg / under 100 kg | 55% / 30% | 65% / 50% | |
| Gate leaf 1.2–1.6 m; over 80 kg / under 80 kg | 55% / 40% | 65% / 50% | |
| Gate leaf over 1.6 m; over 60 kg / under 60 kg | 55% / 40% | Not permitted | |
| Temperature above 40 °C or below 0 °C, or humidity above 80% | +15% | +15% | |
| Solid infill | +15% | +10% | |
| Windy location | +15% | +10% | |
If the weight is exactly at the boundary of a listed range, use the higher index when selecting the system. Assess whether the system is suitable if movement resistance is higher or the gate is exposed to wind.
Installing the brackets and full arm
Before starting work, disconnect the mains supply and any battery or solar power source. The operator must not be used to compensate for a poorly hung, damaged or binding gate.
Mounting surface, dimensions A/B and clearance E
| Requirement | What to observe |
|---|---|
| Mounting surface on the post | At least 80 mm-wide solid mounting surface. For a width of 80–135 mm, turn the rear mounting bracket 90° as shown. |
| Operator position | Vertical, with the arm facing up. Do not install the operator upside down with the arm facing down. |
| Front bracket | Secure it to a solid part of the gate leaf, such as the structural frame; the operator and arm must be level. |
| Clearance E | 80–299 mm: the arm must be shortened; maximum opening angle 90°. From 300 mm: full arm; maximum opening angle 110°, depending on A/B. |
| Dimensions A/B | Measure B from the hinge axis to the mounting surface. Set A for the selected angle so that the A/B point falls within the permitted area of the chart. |
| Stops | Fit fixed, sufficiently robust mechanical stops for both the open and closed positions; these are not automatically included with a standalone operator. |
- Fit solid stops in the open and closed positions, then determine the required angle and mounting dimensions A/B. Check the entire arm movement area.
- Assemble the arm and secure the rear bracket to the supporting structure using suitable anchors. Install the operator vertically and release it.
- With the gate leaf closed, extend the arm as far as it will go and check that it is mechanically secured in its end position. Position the front bracket on a solid part of the frame. The curved arm faces the gate leaf; level the arm.
- Secure the bracket temporarily at first. Move the gate through its full travel by hand and check that the arm does not hit the post or wall and that the gate leaf reaches both stops.
- Complete the installation, insert the pins and Benzing retaining rings. Level the front bracket and check the 75 mm dimension shown in the installation diagram.
- Move the gate leaf to approximately halfway along its travel, lock the operator with the key and gently move the gate by hand to engage the gear.
Shortening the arm when space is limited
Shorten the arm before finally securing the bracket. The maximum opening angle with a shortened arm is 90°, and the maximum gate leaf length is 1.6 m, according to the load chart.
- Set the open position to no more than 90° and fit a temporary stop. Measure B; use the chart for the shortened arm to determine A and the distance C between the pins.
- Set the arm to dimension C and temporarily secure the front bracket with the gate leaf closed. When the gate is open, check the position of the pins relative to the hinge as shown in diagram AA/BB.
- If the taut checking string runs as in BB, increase C by a few millimetres and repeat the test until it reaches position AA, making sure the arm does not touch any obstacle.
- Only after checking the geometry, cut the arm as shown in the original drawing, assemble it, and permanently secure the bracket and fixed stops.
Connecting the WL1024 to the WL1024C control unit
Do not connect the WL1024 to 230 V. It is powered by the WLA1 motor output on the WL1024C. Use a cable 3 × 1.5 mm², maximum 6 m: two motor wires and a protective earth conductor. The motor wires reverse polarity when the direction changes; they are not a constant +/− supply for accessories.
- Disconnect all power sources. Remove the bottom cover of the WL1024 and the four screws securing the cable-gland bracket; keep the two spacers.
- Feed the cable through the cable gland. Connect the three wires exactly as shown by the symbols on the motor terminal block, and connect the protective earth wire to the marked earth terminal. Tighten the cable gland.
- Adjust the two inner supports so that they rest against the post. Trim the edge of the cable-gland bracket as shown, then refit both spacers and the cover.
- On the WLA1, connect the second motor to its M1 motor output. Set jumpers JA/JB according to the position of the control unit and the gate-leaf overlap, as shown in the table below.
The M1/M2 designation during setup depends on the JA/JB configuration and the gate-leaf overlap. Do not select the jumpers based only on which side the WL1024 motor is on; use the corresponding diagram showing the control unit and the overlapping gate leaf.
Accessory terminals on the WLA1
These terminals are on the WL1024C, not on the standalone WL1024. Take auxiliary power from the specific terminals marked in the detail below, not from an arbitrary pair of contacts.
| Connection | Polarity and electrical specifications |
|---|---|
| Auxiliary power | + left terminal of the P.P. pair; − right terminal of the STOP pair, when the labels are oriented as shown in the diagram below. Voltage 18–31 V DC with mains or solar power, 11–14 V DC with PS424. Maximum total current draw 200 mA. Power remains available in Stand-by. |
| BlueBUS / NICE EPMB | Two wires in parallel, non-polarised. Use 2 × 0.5 mm² cable up to 20 m; for 20–40 m, use 2 × 1 mm². Set TX and RX to matching addresses, then repeat device setup. |
| P.P. – command | Normally open voltage-free NO contact. Do not use the +/− power supply for the command input. |
| STOP | NO, NC or 8.2 kΩ, depending on the safety device; the type is stored during setup. Contact is non-polarised, do not connect an external voltage. |
| ELS – electric lock | 12 V AC, 15 VA maximum; no +/−. This specification applies to the electric-lock function. |
| FLASH / NICE WLT | FLASH connector on the WL1024C power section; retain the original connector and WLT wiring. For the warning-light function, the output is 12 V DC, 21 W maximum. Do not use the P.P./STOP polarity here. |
Initial start-up of a double-leaf gate
Carry out the following steps on the WLA1 in the WL1024C after installation is complete, the wiring has been checked and the fixed stops have been fitted. Keep people and obstacles clear of the gate area. These instructions are for a board with four LEDs, L1–L4.
1. BlueBUS and STOP setup
- After switching on, the BlueBUS LED should flash regularly, about once per second. If the indicator pattern is unusual, switch off the power and check the wiring.
- Press and hold OPEN + STOP/SET for approximately 3 seconds. Release when L1 and L2 start flashing rapidly.
- When setup is complete, STOP should be lit and L1/L2 should be off. Repeat setup every time a device is added or removed, even if no devices were originally connected.
2. Limit-position setup
- Check JA/JB. Unlock both motors, move the gate leaves to halfway along their travel, then lock them again.
- Press and hold STOP/SET + CLOSE for approximately 3 seconds. Release when L3/L4 flash rapidly.
- The system should slowly close M1, slowly close M2, slowly open both leaves to the stops, then close them fully at speed.
- If the direction or sequence is incorrect, press any button immediately. After disconnecting the power, check JA/JB and the polarity of the two WL1024 motor wires; do not change the protective earth wire.
- After successful closing, L3/L4 will go out. Test a full opening and closing cycle with slow-down. Activation of a photocell or another command during setup interrupts the procedure; repeat it from the beginning.
Double-leaf gate settings on the WLA1
Nothing is programmed on the standalone WL1024. The following settings apply to the WLA1 control unit with four LEDs, L1–L4, in the WL1024C motor. During programming, the OPEN and CLOSE buttons are used to select; STOP/SET confirms. Slow-down and limit positions are determined by travel learning. The gate-leaf sequence must match the JA/JB configuration.
Level I – switching functions on and off
- Press and hold STOP/SET for approximately 3 seconds. Release when L1 starts flashing.
- Use OPEN or CLOSE to move the flashing LED to the required function.
- Briefly press STOP/SET to change its state: short flash = OFF, long flash = ON.
- Wait 10 seconds without pressing a button; programming will end and the changes will be saved. When setting additional functions, do not leave more than 10 seconds between button presses.
| LED – function | ON / OFF and factory setting |
|---|---|
| L1 – Automatic closing Closes after the set pause time. | ON: after opening, the gate closes when the pause time expires; the default is 30 s. OFF – factory setting: semi-automatic operation; a command is required to close. |
| L2 – Closing after photocell activation Shortens the wait after passage. | ON: photocell activation while opening or closing reduces the pause to 5 s. If automatic closing is disabled and the photocell is activated while the gate is closing, the programmed pause time is applied after activation. OFF – factory setting: this function is disabled. |
| L3 – Closing after power is restored Behaviour when power is restored. | ON: if the control unit detects that the gate is open after power is restored, it closes it after a 5 s pre-flash. OFF – factory setting: restoring power will not trigger closing by itself. |
| L4 – BlueBUS standby Energy-saving mode, especially when using battery or solar power. | ON: 1 minute after a manoeuvre, the BlueBUS output and LEDs switch off, except for the slowly flashing BlueBUS LED. A new command restores operation after a short delay. OFF – factory setting: normal operation without this power-down. |
Level II – parameter values
The input LED selects the parameter; the value LED indicates its setting. Bold values are the factory settings. Any change to force or speed must be followed by a functional and safety test of the entire gate.
- Press and hold STOP/SET for approximately 3 seconds; release when L1 flashes.
- Use OPEN or CLOSE to select the input LED for the desired parameter.
- Press STOP/SET again and hold it. After approximately 3 seconds, the LED for the current value lights up.
- While continuing to hold STOP/SET, select the value LED using OPEN or CLOSE. Then release STOP/SET.
- Wait 10 seconds without pressing a button, to save the setting and exit programming.
| Input LED – name and description | Setting LED – value |
|---|---|
| L1 – Pause time The wait before closing; applies when automatic closing is enabled. | L1 – 5 s L2 – 30 s L3 – 60 s L4 – 120 s |
| L2 – Step-by-step Sequence of commands from P.P. and the remote control. | L1 – open → stop → close → stop L2 – open → stop → close → open L3 – open → close → open → close L4 – condominium mode: while opening, P.P. and OPEN have no effect; CLOSE reverses movement to closing. While closing, P.P. and OPEN reverse movement to opening; CLOSE has no effect. |
| L3 – Motor speed Speed during the normal travel cycle. | L1 – slow L2 – medium L3 – fast L4 – very fast |
| L4 – Motor force Force level for both motors; it must not be used to compensate for binding or incorrect geometry. | L1 – level 1, minimum force L2 – level 2 L3 – level 3 L4 – level 4, maximum force |
Remote control
Transmitters NICE MYGO4 are programmed to the plug-in receiver NICE OXIBD in the WL1024C control motor, following its instructions. Programming the transmitter is separate from device and travel learning; the WL1024 does not have a built-in radio receiver.
Restoring WLA1 settings
On the WLA1, press and hold OPEN + CLOSE, until L1 and L2 start flashing, then release the buttons. The control board restores the factory settings. Repeat device learning and travel learning and the safety test. This procedure does not erase the receiver’s radio memory.
Backup battery and solar power
NICE PS424 is connected to the WL1024C control motor only after installation, learning and testing are complete. The WL1024 receives power from it via the WLA1. Use the designated battery connector; do not confuse its polarity with the accessory auxiliary terminals.
NICE SOLEMYO SYKCE30 is an alternative to mains power, subject to checking sunlight conditions and the number of cycles. Mains power and the solar source must not be used at the same time. The WL1024 on its own does not include a battery or solar kit.
If the second gate leaf does not work properly
| Symptom | What to check |
|---|---|
| WL1024 does not move | Check the power supply and WLA1 status in the WL1024C, that the motor terminal block is fully seated, the 3 × 1.5 mm² cable, and whether the drive is jammed. |
| The gate leaf opens instead of closing during learning | Stop the learning procedure. After disconnecting the power sources, check JA/JB and the WL1024 motor wires according to the wiring diagram. |
| The gate leaves overlap in the wrong order when closing | Check the JA/JB configuration against the actual leaf overlap and make sure the travel has been learned correctly. Repeat the learning procedure after making repairs. |
| The motor stops or reverses | First disengage the motor and check movement resistance, arm geometry and the fixed stops. Check the photocells and STOP. Do not increase the force to compensate for a mechanical fault. |
| L1/L2 or L3/L4 flash slowly | L1/L2 indicate that device learning is required; L3/L4 indicate that end-position learning is required. Continue with initial start-up. |
| Only the remote control is not working | If the gate responds to the WLA1 button, check the transmitter battery and receiver, not the wiring to the second motor. |
Manual release during a power failure
- Stop the gate and hold the leaf so that it cannot move on its own. Open the cover and insert the release key.
- Turn the key almost one full turn clockwise. The leaf can now be moved manually.
- To re-engage the drive, turn the key counterclockwise and gently move the leaf until the drive engages mechanically.
- Remove the key, turn the release disc 90° counterclockwise, and close the cover. For a double-leaf gate, release each motor separately.
Pre-use check
- With the motor released, the gate leaf must be able to be opened and closed manually with a force of less than 390 N and remain stationary when released. This is a manual movement test, not an allowable impact force on a person.
- Check the anchors, pins, retainers, covers and the full movement of the arm. Perform repeated opening, closing and stopping tests.
- Test each photocell, safety edge and STOP separately. If protection relies on force limitation, measure the impact forces and verify the safety of the complete assembly.
- Hand over the gate only after all tests have been passed. The owner must receive the operating instructions, a demonstration of how to release the drive, and a maintenance schedule. Children and other people must stay clear of the moving gate leaves.
Maintenance and regular inspection
Arrange an inspection at least every 6 months or after 20,000 cycles, whichever comes first. Disconnect all power sources before carrying out any work. Check the fastening, corrosion, play in the pins, retaining rings, arm wear, and cover seals; replace any damaged parts. Repeat the functional and safety tests after maintenance.
WL1024 technical specifications
| Parameter | Value |
|---|---|
| Type | Articulated electromechanical motor without a control unit |
| Motor power supply | 24 V DC from WLA1 in WL1024C |
| Rated current | 2 A |
| Starting current | 3 A, max. 2 s |
| Rated torque | 50 Nm |
| Angular speed at no load | 0.20–0.30 rad/s |
| Angular speed at rated torque | 0.16–0.24 rad/s |
| Operation | Max. 100 complete cycles per day; WLA1 limits operation to approximately 50 cycles/hour |
| Continuous operation | Approximately 10 minutes |
| Ingress protection rating | IP44 with the cover intact and closed |
| Temperature | −20 to +50 °C |
| Dimensions | 90 × 125 × 385 mm |
| Motor weight | 4.3 kg |
The motor is not suitable for acidic, highly saline, or explosive environments. The stated number of cycles does not guarantee suitability for every gate; load limits and the condition of the mechanism also apply.
The dimensional drawing shows a width of 85 mm; the drive unit's technical dimensions are 90 × 125 × 385 mm. Before drilling, check the actual motor and bracket, and leave the entire arm movement area unobstructed.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]