NICE TITAN TTN6024HS - standalone operator for swing gates with a leaf up to 6 m / 450 kg


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE TITAN TTN6024HS - standalone operator for swing gates with a leaf up to 6 m / 450 kg NICE TITAN TTN6024HS - standalone operator for swing gates with a leaf up to 6 m / 450 kg
NICE-TTN6024HS
within 3 days
€330.37 excluding VAT
€406.36 including VAT

 pcs
Weight
12 kg

Description of NICE TITAN TTN6024HS - standalone operator for swing gates with a leaf up to 6 m / 450 kg

NICE TITAN TTN6024HS is a standalone fast linear actuator for one gate leaf. The motor has 24 V DC and a magnetic encoder; it does not include a control unit. It connects to NICE MC824HR30. A double-leaf gate requires two motors and one suitably wired control unit.

This is a non-reversible drive with convenient key-operated release at the top. Opening to 90° takes approximately 19 seconds in a typical installation, excluding start-up and slow-down; the actual time depends on the installation dimensions, settings and load. The 6 m and 450 kg limits must be assessed together according to the application chart.

Quick navigation
Control unit and accessoriesGate kits
Package contentsSelection and limits
Bracket installationMotor and encoder
Accessory polarityInitial start-up
Settings and remotesBattery and solar power
TroubleshootingManual release
Safety testMaintenance
Specifications and dimensionsPDF manual

Control unit and compatible accessories

The magnetic encoder helps the control unit track the position of the gate leaf and detect obstacles. Automatic position learning, slow-down in both directions, three-button operation and force adjustment are provided by the MC824HR30 with MCA1R30 board. The control unit uses dual obstacle-detection technology. Safety must be verified on the complete gate.

WhatWhyType
Control unitControls one or two TTN6024HS motors and their magnetic encoders.
PhotocellsPassage protection. BlueBUS is the accessory connection on the control unit, not the motor power cable.
Warning lightMovement signal from the FLASH output.
Receiver and remote controlPlug-in receiver in the control unit and a compatible transmitter; these are not included with the standalone motor.
Electric lockRequired for gate leaves longer than 3 m. Choose a vertical or horizontal version to suit the gate.
Backup power supplyOperation during a power cut; select according to the connector and control unit version.
Solar kitAlternative power supply, subject to an assessment of consumption, number of cycles and sunlight conditions.

TTN6024HS uses the MC824H, currently the MC824HR30; MC824L is not a substitute for it. Use the exact designation MC824HR30 and the settings for the non-reversible TTN6024HS motor.

Kits for one or two gate leaves

All listed TITAN kits include the MC824HR30, OXIBD receiver and MYGO4 remote control. Versions with photocells add EPMB; versions with accessories also include the ELDC warning light. The limits always apply to one gate leaf and one motor.

One gate leafStandalone motorTwo gate leaves
Basic kit
With photocells
With accessories

TITAN TTN6024HS kit for one gate leaf
1 × TTN6024HS
24 V DC
Magnetic encoder
Without control unit

NICE TITAN TTN6024HS motor only
Basic kit
With photocells
With accessories

TITAN TTN6024HS kit for two leaves

What’s included with the standalone operator

The package contains one TTN6024HS motor, a front and rear mounting bracket, and release keys. The control unit, receiver, remote controls, photocells, warning light, and backup battery are available separately or as part of the relevant kit. Fixings for the supporting structure must be suitable for the specific gate.

Leaf length, weight, and suitability

To select a motor, you need to know the leaf’s length and weight, the resistance to movement, the hinge positions, and the effects of wind. The leaf must be rigid, correctly hinged, and move smoothly by hand along its entire travel.

ParameterStandalone limit
Length of one leafMaximum 6 m
Weight of one leafMaximum 450 kg; the permitted weight decreases as the leaf gets longer

The 6 m and 450 kg limits do not apply simultaneously. In the graph below, TTN6024HS is represented by the darker area marked with this model. The horizontal axis shows leaf length in metres and the vertical axis shows its weight in kilograms; the combination must fall within the permitted area.

TITAN: the darker area of the graph applies to TTN6024HS, and the lighter area to TTN3724HS

An electric lock is required for a leaf longer than 3 m, for example NICE PLA10 or NICE PLA11. Choose its orientation to suit the gate; wiring to ELS is shown in the output table.

The leaf’s height and shape, solid infill, strong winds, and resistance to movement can significantly reduce the permitted load. Before choosing a long or heavy leaf, contact us and provide its dimensions, weight, infill type, and expected operating frequency. Using two motors does not change the limit for an individual leaf.

Motor installation and bracket fixing

Disconnect all power sources, including the battery, before starting work. Neither the motor nor the front bracket must bear against weak gate infill; the fixings must transfer the forces to the supporting structure.

Dimensions A/B, clearance, and stops

RequirementWhat to observe
Geometry for 100°A = 200 mm, B = 280 mm as shown in the drawing.
Geometry for 115°A = 280 mm, B = 280 mm. A/B are distances from the hinge axis, as shown in the illustration; they are not the dimensions of the post cross-section.
FixingFix the rear bracket to a solid base and the front bracket to the load-bearing gate frame. The motor must be level, and the pins must rotate freely.
Stroke680 mm; installation length L from 1,030 to 1,710 mm, depending on the piston position. Check the full movement to ensure the geometry does not force the motor beyond its stroke.
Height for low-level installationAt least 110 mm above ground. Allow sufficient clearance for access, manual release, and protection from water and dirt.
StopsProvide a firm mechanical stop for the gate in both the open and closed positions. Learning the positions does not replace correct mechanical setup and robust stops.
ClearanceCheck the full travel of the motor and leaf, ensure the cover can be opened, and allow access to the release key.

TITAN: meaning of mounting dimensions A and B at the brackets

Bracket installation procedure

  1. Determine the positions of the front and rear brackets according to the geometry and the required opening angle. Fix the rear bracket, check that it is level, and hang the motor on it.
  2. Release the motor using the key. Fully extend the piston and temporarily position the front bracket on the leaf as shown in the installation drawing.
  3. Align the motor, connect the piston to the front bracket, and secure it with the pin. Move the leaf through its full travel by hand and check that it reaches the open stop without catching.
  4. Disconnect the piston from the front bracket, permanently fix the bracket, and reconnect the motor. During welding, the motor must be disconnected from the power supply and protected from welding current and heat.
  5. Check the pins, fixings, and full manual movement. Before programming, move the leaf to approximately the midpoint of its travel and lock the motor.

TITAN: bracket position, motor alignment, and rear bracket fixing

TITAN: extending the piston and connecting it to the front bracket

Motor and magnetic encoder wiring

The motor operates on 24 V DC and must not be connected directly to 230 V. The mains supply must be connected to the control unit. The motor has two terminals marked MOTOR and two marked ENCODER; connect the protective conductor to the separate earth lug.

CableConnection and length
Motor3 × 1.5 mm², maximum 10 m: two motor wires and PE. Connect MOTOR to the corresponding M1 or M2 output on the control unit.
Encoder2 × 1 mm², maximum 10 m. Connect ENCODER to the corresponding ENC input for the same motor. ENC polarity does not matter.
Combined cableThe motor and encoder cables can be replaced with a single cable 5 × 1.5 mm² of the specified length. The protective conductor must remain dedicated to PE.
Single leafConnect the motor to M2 and its encoder to the corresponding ENC input for motor 2. M1 remains unused.
Two leavesM2 operates the leaf that opens first; M1 operates the leaf that closes first. Each motor must be paired with its own correctly assigned encoder.

  1. With the power off, remove the motor cover and loosen the cable gland.
  2. Feed the cable through, connect the MOTOR and ENCODER terminals as shown in the illustration, and connect PE to the earth lug. Do not mix up the motor wires and encoder wires.
  3. Tighten the cable gland, check the strain relief and seal, and refit the cover. The cable must have sufficient slack as the motor moves and must not snag.
  4. On the MC824HR30, check the corresponding M/ENC terminals and select the exact motor model before learning the travel limits.

TITAN TTN6024HS: ENCODER, MOTOR and protective earth terminals

The motor terminals do not have fixed +/− polarity: the control unit switches polarity according to the direction of travel. For movement in the opposite direction, check the pair of motor wires after disconnecting the power sources; PE remains unchanged. The full board orientation and wiring diagram are in the MC824HR30 wiring diagram.

Accessory wiring and polarity

Accessories connect to the MC824HR30. The TITAN motor cable is not BlueBUS. For auxiliary power, follow the STOP and SbS labels and the detail below.

ConnectionPolarity and electrical specifications
Auxiliary power supply+ left terminal of the SbS pair; − right terminal of the STOP pair when the labels are oriented as shown in the image. 24 V DC, −30% / +50%, 200 mA max.. Voltage remains present in Stand-by.
BlueBUS / NICE EPMBTwo-wire parallel connection, no polarity. 2 × 0.5 mm² up to 20 m; for 20–40 m, 2 × 1 mm². Set the photocell addresses and repeat device learning.
SbS, OPEN, CLOSEVoltage-free NO switching contacts. No +/−; do not connect an external voltage.
STOPNO, NC or 8.2 kΩ, depending on the connected safety device. The input type is detected during learning; the contact has no polarity.
FLASH / NICE ELDCWarning light output 12 V DC, 21 W max.. Connect the ELDC to its FLASH pair, separate from the AEREAL antenna terminals. The ELDC power supply pair is not marked +/− in the diagram; do not apply the auxiliary output SbS/STOP marking here.
ELS / electric lock12 V AC, 15 VA max.; no +/−. Choose PLA10 or PLA11 according to the lock’s mechanical position.

MC824HR30: right STOP minus and left SbS plus for auxiliary power

ELDC: FLASH power supply pair and separate AEREAL antenna terminals

For wiring of the other inputs and outputs, see the complete MC824HR30 terminal table. Do not bypass safety devices just to get the gate moving.

Initial startup with the MC824HR30

Before switching on, complete the brackets, stops, motor and encoder wiring, and safety devices. Keep the entire gate area clear during travel learning.

StepAction on the control unit
1. Check the wiringCheck the motor and its ENC, protective conductors, photocells and STOP. For a single leaf, use M2.
2. Motor selectionSet the exact type TTN6024HS on the Motor Type selector, according to the table and original selector image. Make this selection before learning the end positions.
3. Device learningScan the connected BlueBUS and STOP devices according to the MC824HR30 initial startup procedure. Repeat after adding or removing devices.
4. Position learningRelease the mechanism, move the leaves to a suitable starting position, then re-engage it. Use the position-learning procedure for the selected mode. If the direction or learning sequence is incorrect, stop learning immediately.
5. System testCheck full opening and closing, the leaf overlap sequence, slow-down, and all safety devices. Hand over the gate only after these checks.

Programming and remote controls

The TITAN TTN6024HS has no built-in adjustment buttons. Adjustments are made using the three buttons on the MC824HR30: OPEN, STOP/SET and CLOSE. Automatic closing, pause time, force, speed, slow-down and leaf delay are adjusted on the control unit to suit the specific gate.

SettingProcedure
Levels I and IIThe complete MC824HR30 programming tables show the ranges, LED values and factory settings.
Force and slow-downIncreasing the force does not fix a gate that is binding. After making adjustments, repeat the operation and safety tests.
Remote controls NICE MYGO4Pair them with the NICE OXIBD receiver according to the radio-control procedure. Learning a transmitter is separate from learning the travel limits.
Deletion or resetFollow the procedure for the specific control unit or receiver. Resetting the board and erasing the radio memory are separate operations.

Operation during a power cut

If there is no battery, release the gate using the key. For automatic backup with the current control unit, use NICE PSS324. Connect the battery to the designated control-unit connector only after installation, learning and testing are complete; it is not included with the motor alone.

When using NICE PS124 or the older PS324 with the MC824HR30 an adapter NICE CABLA11 and it must be on the board Standby disabled (level I, L4 = OFF). The reduction alone is not enough without the correct settings. Details are in the MC824HR30 backup power supply wiring.

SOLEMYO solar power supply

NICE SOLEMYO SYKCE30 allows a suitable system to be powered off-grid, taking into account the daily number of cycles, accessory consumption and sunlight conditions. For SOLEMYO, you need to enable Standby. Mains and solar power must not be connected at the same time. This setting differs from using PS124/PS324 with CABLA11.

Troubleshooting

SymptomWhat to check
The motor does not moveThe control unit’s power supply and indicators, a jammed gearbox, the MOTOR connection and the corresponding ENC. Use the MC824HR30 diagnostics.
It moves in the wrong direction during learningStop the learning process. After disconnecting all power sources, check the motor wires and selected model; leave the protective conductor connected to PE.
It stops or reversesFirst, check the mechanics, geometry and stops manually. Then check the safety inputs and the corresponding encoder. Increasing the force will not solve mechanical resistance.
The leaves overlap incorrectlyM1/M2 assignment, their ENC connections and the opening/closing delay according to the overlap. Repeat the required learning process.
The button works, but the remote control does notCheck the transmitter, battery and radio receiver memory as described in pairing remote controls.
It does not work during a power outageCheck the battery condition and connection; with PS124/PS324, also check CABLA11 and Standby OFF. Check the backup conditions.

Manual release and re-engagement

  1. Stop movement and secure the gate leaf against moving on its own. Remove the rubber release cover.
  2. Insert the key and turn it 90° clockwise. The gate leaf can now be opened or closed manually.
  3. Before returning to automatic operation, move the gate leaf approximately halfway along its travel and turn the key 90° counterclockwise and cover the opening.
  4. For a double-leaf gate, release or re-engage each motor separately.

TITAN TTN6024HS: lifting the cover and releasing with the key

TITAN TTN6024HS: re-engaging the motor

Safety testing and handover

  1. When released, the gate leaf must be able to be opened and closed manually with a force of no more than 390 N. This is a test of mechanical movement, not an allowable impact force on a person.
  2. Re-engage the motors and test opening, closing and stopping. Check the stops, overlap between the leaves and attainment of the end positions.
  3. Test photocells, STOP, safety edges and other protective devices individually. If protection relies on force limitation, measure impact forces and verify the safety of the system.
  4. The control unit sets the motor force; the maximum motor force listed in the technical table is not a safe contact force for a person.
  5. Hand over the gate only after successful testing and instructing the owner on operation, release and maintenance. Children must not play with the controls or in the gate’s travel area.

Regular maintenance

Arrange an inspection at least every 6 months. With the power disconnected, check that the brackets and screws are secure, and inspect for corrosion, wear on pins and moving parts, and damage to cables, grommets and seals. Replace damaged parts; after restoring power, repeat the functional and safety tests on the entire gate. Do not try to fix a mechanical fault by increasing the force.

TTN6024HS technical specifications

ParameterValue
DesignNon-reversible linear actuator with magnetic encoder
Motor power supply24 V DC from a compatible control unit
Control unitMC824H; current MC824HR30 separately
Individual leaf limits6 m / 450 kg; combination according to the chart
Piston speed0.027 m/s = 2.7 cm/s
Maximum current / power consumption7 A / 150 W
Force1,900 N
Stroke680 mm
Duty cycleContinuous duty cycle according to the manufacturer; suitability for operation must be assessed for the complete gate and control system
Protection ratingIP54
Operating temperature−20 to +55 °C
Body dimensions1,080 × 105 × 170 mm
Installation length L1,030–1,710 mm depending on piston extension
Motor weight9 kg

The installation length L shown in the drawing and the body dimensions are different measurements. When assessing the available space, allow for the brackets, gate leaf movement and access to the cover.

TITAN TTN6024HS: installation length L, width W and height H

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE TITAN TTN6024HS - standalone operator for swing gates with a leaf up to 6 m / 450 kg

Product: NICE TITAN TTN6024HS - standalone operator for swing gates with a leaf up to 6 m / 450 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.