NICE TITAN TTN3724HS - standalone operator for swing gates with a leaf up to 3.7 m/450 kg


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE TITAN TTN3724HS - standalone operator for swing gates with a leaf up to 3.7 m/450 kg NICE TITAN TTN3724HS - standalone operator for swing gates with a leaf up to 3.7 m/450 kg
NICE-TTN3724HS
within 3 days
€270.42 excluding VAT
€332.62 including VAT

 pcs
Weight
12 kg

Description of NICE TITAN TTN3724HS - standalone operator for swing gates with a leaf up to 3.7 m/450 kg

For the swing gate operator NICE Titan TTN3724HS with control unit version R30 (MC824HR30) to connect a backup power supply PS124 or PS324 a cable adapter must be used CABLA11.

NICE TITAN TTN3724HS is a standalone, high-speed linear actuator for one gate leaf. The motor has 24 V DC and a magnetic encoder; it does not include a control unit. It connects to NICE MC824HR30. A double-leaf gate requires two motors and one correctly wired control unit.

This is a irreversible drive with convenient key-operated release at the top. Opening to 90° takes approximately about 12 seconds in a typical installation, excluding acceleration and deceleration; the actual time depends on the installation dimensions, settings and load. The 3.7 m and 450 kg limits must be assessed together using the application chart.

Quick navigation
Controls and accessoriesGate kits
Package contentsSelection and limits
Bracket installationMotor and encoder
Accessory polarityInitial startup
Settings and controlsBattery and solar power
TroubleshootingRelease
Safety testMaintenance
Specifications and dimensionsPDF manual

Control unit and compatible accessories

The magnetic encoder helps the control unit track the leaf's position and detect obstacles. Automatic position learning, deceleration in both directions, three-button control and force adjustment are provided by the MC824HR30 with MCA1R30 board. The control unit uses dual obstacle-detection technology. Safety must be verified on the complete gate.

WhatWhyType
Control unitControls one or two TTN3724HS motors and their magnetic encoders.
PhotocellsPassageway protection. BlueBUS is the accessory connection on the control unit, not a motor power cable.
Warning lightMovement indication from the FLASH output.
Receiver and remote controlPlug-in receiver for the control unit and a compatible transmitter; not included with the standalone motor.
Electric lockAdditional leaf locking, depending on the gate mechanism; vertical or horizontal version.
Backup powerOperation during a power outage; select according to the connector and control-unit version.
Solar kitAlternative power supply, subject to an assessment of consumption, number of cycles and sunlight conditions.

For the TTN3724HS, use the MC824H designed for its encoder. The MC824L and control units designed for a different encoder type are not substitutes for this control unit.

Kits for one or two leaves

All listed TITAN kits include the MC824HR30, OXIBD receiver and MYGO4 remote control. Versions with photocells also include the EPMB; versions with accessories also include the ELDC warning light. The limits always apply to one leaf and one motor.

One leafStandalone motorTwo leaves
Basic kit
With photocells
With accessories
NICE TITAN TTN3724HS single-leaf kit
One motor + control unit.
TITAN TTN3724HS
NICE TITAN TTN3724HS standalone motor
This product. Without the control unit, photocells or radio control.
Basic kit
With photocells
With accessories
NICE TITAN TTN3724HS double-leaf kit
Two motors + one control unit.

What’s included with the standalone operator

The package contains one TTN3724HS motor, front and rear mounting brackets, and release keys. The control unit, receiver, remotes, photocells, warning light and backup battery are selected separately or as part of the relevant kit. The fixings used in the load-bearing substrate must be suitable for the specific gate.

Leaf length, weight and suitability

To select a motor, you need to know the leaf’s length and weight, resistance to movement, hinge position and exposure to wind. The leaf must be rigid, correctly hinged and move smoothly by hand along its entire travel.

Length of one leafWeight according to the graph
Up to 2.7 mMaximum 450 kg
3.1 mApproximately 335 kg
3.7 mMaximum 225 kg

Between the points shown, the graph curve determines the limit. Therefore, the motor is not suitable for a 3.7 m leaf weighing 450 kg. Solid infill, wind or greater resistance to movement may require a different setup, even at a lower weight.

TITAN TTN3724HS: graph of permitted leaf length and weight

Motor installation and bracket fixing

Before starting work, disconnect all power sources, including the battery. The motor and front bracket must not bear against weak gate infill; the fixings must transfer forces to the supporting structure.

Dimensions A/B, clearance and stops

RequirementWhat to observe
Geometry for 110°For the TTN3724HS, the specified dimensions are A = 180 mm and B = 180 mm. A/B are dimensions shown in the drawing, not the dimensions of the post cross-section.
FixingFix the rear bracket to a solid substrate and the front bracket to the load-bearing frame of the leaf. The motor must be level, and the pins must rotate freely.
Stroke510 mm; installation length L from 860 to 1 370 mm, depending on piston position. Check the full travel to ensure that the geometry does not force the motor beyond its stroke.
Height for low-level installationAt least 110 mm above ground level. Allow clearance for access, manual release and protection from water or dirt.
StopsProvide a firm mechanical stop for the gate in both the open and closed positions. Learning the positions does not replace proper mechanics and durable stops.
ClearanceCheck the full travel path of the motor and leaf, that the cover can be opened, and that the release key is accessible.

TITAN: what mounting dimensions A and B mean for the brackets

Bracket installation procedure

  1. Determine the positions of the front and rear brackets according to the geometry and required opening angle. Fix the rear bracket, check that it is level, and hang the motor on it.
  2. Release the motor using the key. Fully extend the piston and temporarily position the front bracket on the leaf as shown in the installation drawing.
  3. Level the motor, connect the piston to the front bracket and secure it with the pin. Move the leaf manually through its full travel and check that it reaches the open stop without binding.
  4. Disconnect the piston from the front bracket, permanently fix the bracket, and reconnect the motor. During welding, the motor must be disconnected from the power supply and protected from welding current and heat.
  5. Check the pins, fixings and full manual travel. Before position learning, move the leaf approximately halfway along its travel and lock the motor.

TITAN: bracket position, motor alignment and rear bracket fixing

TITAN: extending the piston and connecting it to the front bracket

Connecting the motor and magnetic encoder

The motor operates on 24 V DC and must not be connected directly to 230 V. Mains power is connected to the control unit. The motor has two terminals labelled MOTOR and two labelled ENCODER; the protective conductor connects to a separate earthing lug.

CableConnection and length
Motor3 × 1.5 mm², maximum 10 m: two motor wires and PE. Connect MOTOR to the corresponding M1 or M2 output on the control unit.
Encoder2 × 1 mm², maximum 10 m. Connect ENCODER to the corresponding ENC input for the same motor. ENC polarity is not important.
Combined cableThe motor and encoder cables can be replaced with a single 5 × 1.5 mm² cable of the specified length. The protective conductor must remain dedicated to PE.
Single leafConnect the motor to M2 and its encoder to the corresponding ENC input for motor 2. M1 remains unused.
Two leavesM1 and M2 must be assigned to the correct encoders, with the movement sequence set according to the overlap of the leaves.

  1. With the power off, remove the motor cover and loosen the cable gland.
  2. Feed the cable through, connect the MOTOR and ENCODER terminals as shown, and connect PE to the earthing lug. Do not confuse the motor wires with the encoder wires.
  3. Tighten the cable gland, check strain relief and sealing, and refit the cover. Allow enough cable slack for motor movement and make sure the cable cannot snag.
  4. On the MC824HR30, check the matching M/ENC connections and select the exact motor model before learning the travel.

TITAN TTN3724HS: ENCODER and MOTOR terminals and protective earthing

The motor terminals do not have fixed +/− polarity: the control unit reverses polarity according to the direction of travel. If the motor runs in the wrong direction, check the pair of motor wires after disconnecting all power sources; do not change PE. For the complete board layout and wiring diagram, see the MC824HR30 wiring.

Connecting accessories and checking their polarity

Accessories connect to the MC824HR30. The TITAN motor cable is not BlueBUS. For the auxiliary power supply, follow the STOP and SbS labels and the detail below.

ConnectionPolarity and electrical specifications
Auxiliary power supply+ left terminal of the SbS pair; − right terminal of the STOP pair when the labels are oriented as shown in the image. 24 V DC, −30% / +50%, maximum 200 mA. Voltage remains present even in Standby.
BlueBUS / NICE EPMBParallel connection using two wires, with no polarity. 2 × 0.5 mm² up to 20 m; 2 × 1 mm² for 20–40 m. Set the photocell addresses and repeat device learning.
SbS, OPEN, CLOSEVolt-free NO switching contacts. No +/−; do not connect an external voltage.
STOPNO, NC or 8.2 kΩ, depending on the connected safety device. The input type is detected during learning; the contact is non-polarized.
FLASH / NICE ELDCOutput for the warning light 12 V DC, max. 21 W. Use the ELDC input and wiring method specified for the power supply in use; do not route the auxiliary SbS/STOP output polarity here.
ELS / electric lock12 V AC, max. 15 VA; no +/−. Choose PLA10 or PLA11 according to the mechanical position of the lock.

MC824HR30: STOP on the right is negative and SbS on the left is positive for auxiliary power

For wiring the other inputs and outputs, see the complete MC824HR30 terminal table. Do not bypass safety devices just to get the gate moving.

Initial start-up with the MC824HR30

Before switching on, complete the brackets, stops, motor and encoder wiring, and safety devices. Keep the entire gate area clear during the learned movements.

StepWhat to do on the control unit
1. Wiring checkCheck the motor and its ENC, protective conductors, photocells and STOP. For a single leaf, use M2.
2. Motor selectionSet the exact type TTN3724HS on the Motor Type selector according to the table and the original selector illustration. Make this selection before learning the end positions.
3. Device learningLearn the connected BlueBUS and STOP devices according to the MC824HR30 initial start-up procedure. Repeat after adding or removing devices.
4. Position learningRelease the mechanism, move the leaves to a suitable starting position, then re-engage it. Use the position learning procedure for the selected mode. If the direction or sequence is incorrect, stop learning immediately.
5. System testCheck full opening and closing, the leaf overlap sequence, deceleration, and all safety devices. Only then hand over the gate.

Programming and remote control

The TITAN TTN3724HS has no onboard setup buttons. It is configured using the three buttons on the MC824HR30: OPEN, STOP/SET and CLOSE. Automatic closing, pause time, force, speed, deceleration and leaf delay are adjusted on the control unit to suit the specific gate.

SettingProcedure
Levels I and IIThe full MC824HR30 programming tables show the ranges, LED values and factory settings.
Force and decelerationChanging the force setting does not fix a gate that is sticking. Repeat the functional and safety tests after making adjustments.
Remote controls NICE MYGO4Pair them with the receiver NICE OXIBD following the radio control procedure. Transmitter learning is separate from travel learning.
Erasing or resettingFollow the procedure for the specific control unit or receiver. Resetting the board and erasing the radio memory are different operations.

Operation during a power failure

Without a battery, release the gate using the key. For automatic backup of the current control unit, use NICE PSS324. Connect the battery to the designated control-unit connector only after installation, learning and testing are complete; it is not included with the motor alone.

When using NICE PS124 or the older PS324 with the MC824HR30 adapter NICE CABLA11 and the board must have Standby switched off (Level I, L4 = OFF). The adapter alone is not enough without the correct setting. Details are in the MC824HR30 backup power wiring.

SOLEMYO solar power supply

NICE SOLEMYO SYKCE30 provides off-grid power for a suitable system, subject to an assessment of daily cycle count, accessory consumption and sunlight conditions. For SOLEMYO, you need to switch Standby on. Mains and solar power must not be connected at the same time. This setting differs from using PS124/PS324 with CABLA11.

Troubleshooting

SymptomWhat to check
Motor does not moveControl-unit power and indicators, whether the drive is locked, the MOTOR supply and the corresponding ENC. Use the MC824HR30 diagnostics.
It moves in the opposite direction during learningStop the learning procedure. With all power sources disconnected, check the motor wires and the selected model; leave the protective earth wire connected to PE.
It stops or reversesFirst, check the mechanics, geometry and stops manually. Then check the safety inputs and the relevant encoder. Increasing the force will not solve mechanical resistance.
The gate leaves overlap incorrectlyCheck the M1/M2 assignment, their ENC connections, and the opening/closing delay based on the overlap. Repeat the required learning procedure.
The button works, but the remote control does notCheck the transmitter, battery and radio receiver memory as described under pairing remote controls.
It does not work during a power outageCheck the battery condition and connection; for PS124/PS324, also check CABLA11 and Stand-by OFF. Check the backup power requirements.

Manual release and relocking

  1. Stop the movement and secure the gate leaf to prevent it from moving on its own. Remove the rubber release cover.
  2. Insert the key and turn it 90° clockwise. The gate leaf can now be opened or closed manually.
  3. Before returning to automatic operation, move the gate leaf approximately halfway along its travel, then turn the key 90° counterclockwise and cover the opening.
  4. For a double-leaf gate, release or relock each motor separately.

TITAN TTN3724HS: flip open the cover and release the motor with the key

TITAN TTN3724HS: relocking the motor

Safety checks and handover

  1. When released, the gate leaf must be able to be opened and closed manually with a force of no more than 390 N. This is a test of mechanical movement, not a permissible impact force on a person.
  2. Relock the motors and test opening, closing and stopping. Check the stops, overlap between the gate leaves and that the end positions are reached.
  3. Test the photocells, STOP, safety edges and other protective devices individually. If protection is provided by force limitation, measure the impact forces and verify that the system is safe.
  4. The control unit sets the motor force; the maximum motor force listed in the technical table is not a safe contact force for a person.
  5. Hand over the gate only after successful testing and instructing the owner on operation, release and maintenance. Children must not play with the controls or in the gate's path.

Regular maintenance

Arrange an inspection at least every 6 months. With the power disconnected, check that the brackets and screws are secure; inspect for corrosion and wear on pins and moving parts, and check the cables, cable glands and seals. Replace any damaged parts; once power is restored, repeat the functional and safety checks on the entire gate. Do not try to fix a mechanical fault by increasing the force.

TTN3724HS technical specifications

ParameterValue
TypeNon-reversible linear actuator with magnetic encoder
Motor power supply24 V DC
Control unitMC824H; current model: MC824HR30 separately
Maximum gate-leaf length / weight3.7 m / 450 kg as separate maximum values according to the graph
Maximum piston speed3.2 cm/s = 0.032 m/s
Stroke510 mm
No-load current1.5 A
Rated / maximum current2.5 A / 6 A
Rated / maximum power consumption60 W / 150 W
Rated / maximum force300 N / 2,200 N
Duty cycleContinuous duty cycle according to the manufacturer; suitability for operation depends on the complete gate and control system
Ingress protection ratingIP54
Operating temperature−20 to +55 °C
Body dimensions910 × 105 × 170 mm
Installation length L860–1,370 mm depending on piston extension
Motor weight8 kg

The installation length L shown in the drawing and the body dimensions are different measurements. When assessing the available space, also allow for the brackets, gate-leaf movement and access to the cover.

TITAN TTN3724HS: installation length L, width W and height H

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE TITAN TTN3724HS - standalone operator for swing gates with a leaf up to 3.7 m/450 kg

Product: NICE TITAN TTN3724HS - standalone operator for swing gates with a leaf up to 3.7 m/450 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.