NICE Ten TN2020L - operator for up-and-over garage doors
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
for the question
€327.71 including VAT
| Weight |
|---|
| 7,20 kg |
Description of NICE Ten TN2020L - operator for up-and-over garage doors
NICE TEN TN2020L – operator for an up-and-over garage door
The NICE TN2020L operator is designed for up-and-over garage doors. Before ordering, check the door’s dimensions, weight and construction.
The TN2020L does not have its own control unit. It is a second 24 V DC motor with auxiliary LED lighting for a two-motor setup, controlled by NICE TN2010L. The TN2020L alone must not be connected directly to the 230 V mains. The operator is non-reversible; in the event of a power failure, it allows manual release using the handle.
When to choose this operator
The TEN is designed for properly balanced up-and-over garage doors with counterweights or springs, with or without an overhang. The motor is mounted on the door structure and transmits movement via shafts and telescopic arms. This is not a ceiling-mounted operator with a guide rail for a sectional door.
The TN2020L is an auxiliary motor, not a standalone replacement for the TN2010L. The accessories, receiver, safety inputs and settings for the two-motor setup are all handled by the main TN2010L unit. If you already have a different main unit, check the exact combination and consult its own manual.
| Setup according to the included installation manual | Approximate door dimensions |
|---|---|
| 1 × TN2010L + 1 × TN2020L | Maximum height 2.6 m, maximum width 5.4 m; area up to 14 m². |
Dimensions alone are not enough: what matters is the balance, resistance throughout the door’s travel and the number of cycles. The installation limits stated above apply to configurations set up according to the included manual. Larger doors must be assessed individually based on the specific motor and control unit. Adding a second motor does not replace repairing damaged springs, cables or guides.
Number of cycles and force required to move the door
| Setup | Force required to move | Max. cycles/hour | Max. consecutive cycles |
|---|---|---|---|
| TN2010L + TN2020L | Up to 150 N | 30 | 19 |
| TN2010L + TN2020L | Over 150–250 N | 28 | 16 |
| TN2010L + TN2020L | Over 250–350 N | 25 | 14 |
A cycle means one complete opening and closing; one movement is travel in a single direction. These are maximum operating limits, not a recommendation to increase door resistance. When preparing the door for private use, the force required to move it manually must not exceed 150 N; the manual movement test during commissioning has a separate limit of 225 N. The control unit limits operation according to load and duration to prevent overheating.
Motor and control unit setup
| Setup component | Role in door automation |
|---|---|
| NICE TN2010L | Main motor with integrated control unit, absolute encoder and BlueBUS. Controls the safety devices, receiver and connected second motor. The plug-in receiver is selected separately. |
| NICE TN2020L | Second 24 V DC motor without a control unit. In a two-motor installation, it is connected to the main TN2010L unit; it cannot control the door on its own. |
Standalone motor and required installation equipment
This product page is for the TN2020L. A complete automation system also requires a support bracket, suitable shafts, telescopic arms, controls and safety devices. Their selection depends on the door construction and the number of motors. Before ordering, check what is included and which accessories are required.
Installation component labels:
- A – TEN motor
- B – M6 nuts
- C – M8 nuts
- D – M6 × 14 threaded pins
- E – Ø8 washers
- F – M8 × 110 screws
- G – release rod.
| What | Why | Type |
|---|---|---|
| Support bracket | Motor support bracket, length 1 250 / 2 000 mm. | |
| Shafts | Square-section shafts, 20 × 20 mm, length 1 500 / 200 mm. | |
| Telescopic arms | A pair of straight / curved telescopic arms. Curved arms help when space is limited near the door’s support arm. | |
| Shaft guide | Guide for a pair of drive shafts. | |
| External release | Release from outside using a cable or key lock. OTA12 is not used with side-mounted motors. |
Gate installation and inspection
Install the motor inside the garage. IP44 protection does not permit outdoor installation. Disconnect the mains and any backup battery before carrying out any work.
- Check the condition and balance of the gate, springs, cables, guides and supporting components. The gate must move smoothly by hand along its entire travel and must not drop under its own weight.
- Remove any unnecessary cables and disable the existing lock if it would obstruct motorised operation.
- Select a sturdy bracket and shafts to suit the gate width. Before final tightening, check the full travel of the shafts and telescopic arms; they must not collide with the guide, frame or counterweight.
- Assess potential crushing points around the arms, top edge and bottom edge. If the gate has a wicket door, its opening must be safely monitored.
- The manual release must be reachable at a height of 1.8 m. Install the fixed control within sight of the gate, away from moving parts, at least 1.5 m above floor level.
- If there is no other entrance to the garage, install an external release before handing over the system. The moving gate must not extend onto a public footpath or roadway.
Diagram:
- 1 – TEN
- 2 – 20 × 20 mm square shaft
- 3 – support bracket
- 4 – telescopic arm
- 5 – photocells
- 6 – photocells on stands
- 7 – safety edge
- 8 – low-voltage warning light with antenna
- 9 – control.
This shows the general layout; safety devices must be selected for the actual gate.
Motor dimensions and cable routing
The drawing shows a height of 512 mm, a width of 150 mm, a maximum depth of 160 mm and a shaft output of 20 × 20 mm. Before mounting, also allow room for the cover, release mechanism and gate movement. The technical specification lists a body depth of 158 mm; allow for the 160 mm outline shown in the drawing when planning the space.
With the cover open, make only the cable entries needed and fit suitable cable glands. Keep the mains supply cable separate from low-voltage cables, secure cables against tension and leave enough slack for gate movement. There must be no water or condensation in the conduits or at the entry points. After adjustment, install the cover and check clearance throughout the full travel.
Manual release and re-engagement
Release the gate only when it is stopped, and first secure it against falling. An unbalanced gate or damaged spring may cause sudden movement when released. For a two-motor system, release both motors.
- Stop the gate and disconnect all power supplies.
- Turn the motor handle counterclockwise as shown. Then move the gate by hand without forcing it.
- To re-engage the drive, turn the handle clockwise to the vertical position.
- Move the gate slightly by hand until the gears engage. Only then restore power and check the controls.
For external release, use a suitably installed NICE OTA11 or NICE OTA12. For a two-motor system, the solution must allow both drives to be released safely.
Wiring
| TN2010L main circuit | Cable type and length as specified in the manual |
|---|---|
| Mains power supply | 3 × 1.5 mm², maximum 30 m. For runs over 30 m, use a larger cross-section, such as 3 × 2.5 mm², as determined by the power supply and protection design. |
| 12 V warning light | 2 × 1 mm², maximum 20 m. |
| Antenna | RG58 coaxial cable, maximum 20 m; recommended length under 5 m. |
| BlueBUS photocells | 2 × 0.5 mm², maximum 20 m. |
| Key switch | Maximum 20 m; number of cores depends on the contacts used. The manual allows a shared 4 × 0.5 mm² cable. |
| Contact safety edge | 2 × 0.25 mm², maximum 20 m; an optical safety edge requires wiring according to its three signals. |
Cables must be suitable for the environment and moving installation. Plan the cable route, protection and supply; the specified cross-section alone is not sufficient. Between the motors there are two separate circuits – motor and courtesy light; select the cable according to the supplied system and the diagram below.
Control unit and wiring
TN2010L has built-in control; TN2020L does not. The terminals and procedures below apply to the TN2010L control unit shown in the diagram, with three buttons and eight LEDs, L1–L8. When replacing the NICE TNA2 board or if using a different version, follow the instructions for the version actually installed.
On the board:
- a – terminals
- b – buttons
- c – LEDs L1–L8
- d – input LEDs
- e – courtesy light
- f – fuse F2
- g – SM receiver socket
- h – BusT4
- i – Aerial terminal
- l – battery connector.
Mains and low-voltage accessories
| Circuit / terminals | Wiring and limits |
|---|---|
| TN2010L: 1 / 2 / 3 | Mains 230 V AC, 50/60 Hz: 1 = L (live), 2 = N (neutral conductor), 3 = PE (protective conductor). AC has no positive/negative polarity. The supply must have suitable isolation and protection. |
| Auxiliary power supply | Right STOP contact = GND (−), left SbS contact = 24 V DC (+), in the same orientation as the image. Voltage 24 V DC −30/+50 %, maximum 100 mA total. Remains active in Stand-by. |
| BlueBUS | Parallel two-wire connection for compatible devices, e.g. NICE EPMB. No polarity; this is not a universal 24 V auxiliary output. Maximum 12 BlueBUS load units. |
| SbS / Open / Close | Command pairs for volt-free NO contacts: step-by-step / open / close. Switch the relevant contact pair; do not connect an external power supply. An NO contact has no polarity. |
| Stop | Learned safety input: NO, NC, 8.2 kΩ or compatible optical safety edge; see detailed STOP wiring. |
| Flash | Factory-configured output for a 12 V DC warning light, max. 21 W, e.g. NICE ELDC. Do not connect a 230 V ELAC here. Follow the markings on the installed board for the exact output terminals; do not infer their positions from the auxiliary power supply. |
| Aerial / receiver | Coaxial cable: centre conductor = signal, braid = shield. These are not power supply +/− terminals. With NICE OXIBD connect the external aerial directly to its aerial terminals. |
The positive and negative markings above refer to individual contacts, not the entire two-pole terminal blocks. Connect powered accessories with their + to SbS (+) and − to STOP (−), only if they are compatible with the specified voltage and total current draw. Do not power the TN2020L motor or warning light from this 100 mA output.
The diagram shows alternative wiring configurations for safety devices; it does not mean that all STOP options should be connected at once. For the warning light NICE ELDC connect the power supply to its designated low-voltage input and wire the aerial separately. Set the flashing mode according to the warning light manual for an output that already provides a flashing voltage.
Connecting the TN2010L and TN2020L
The 230 V mains supply is connected only to the main TN2010L. The TN2020L receives motor power from the main unit. It has its own terminals for the motor and light, not a second control unit or its own safety inputs.
| Connections shown in the image | Requirements |
|---|---|
| A – second motor | Connect the TN2010L second-motor output to the TN2020L motor terminals. For both terminal pairs shown left −, right +; maintain − → − and + → +. |
| B – auxiliary light for the second motor | Run a separate cable from the second-motor light output to the TN2020L light terminals. Again, the image shows left −, right +; do not connect to the motor terminals or the 100 mA auxiliary output. |
| Settings on the main TN2010L | Level I, L8 ON = two motors; with one TN2010L, it must remain L8 OFF. |
Read the terminal polarity with the original diagram in the same orientation, and always check against the actual terminal markings. Do not enable two-motor mode when only one motor is installed – it can cause incorrect operation and damage. After changing the configuration, repeat the learning procedure, force calibration and safety tests.
BlueBUS photocells and addressing
NICE EPMB connect using two wires to the BlueBUS terminals on the main TN2010L. Both the TX and RX of one pair must have the same jumpers; the next pair must use a different address. BlueBUS devices are non-polarised and are connected in parallel. Standard relay-type EPM photocells must not be connected to BlueBUS.
| Address | Function with TEN |
|---|---|
| PHOTO / PHOTO II | Monitors closing; height approximately 50 / 100 cm. |
| PHOTO 1 / PHOTO 1 II | Monitors opening and closing; height approximately 50 / 100 cm. |
| PHOTO 2 / PHOTO 2 II | Monitors opening. |
| PHOTO 3 | One photocell safety device protecting the entire automation system, according to the proposed configuration. |
| FA1 / FA2 | Opening command photocell; use only with a compatible type of photocell and in accordance with its instructions. It is not a substitute for the required safety protection. |
When replacing photocells, check that the jumpers have the same function in the instructions for the replacement photocells. After adding or removing any device, perform device recognition and test the response in both directions again. Do not test movement with the safety protection bypassed. EPMB jumper settings.
Sensitive safety edge and STOP input
STOP triggers a stop followed by a brief reverse movement. During setup, the control unit memorises the type of connected device and triggers a protective response when its state changes. Multiple NO contacts can be connected in parallel; NC contacts in series. Resistive safety edges must be connected as specified in their instructions; when cascaded, use a single end-of-line resistor 8.2 kΩ.
| OSE optical edge | Specific contact when viewing the image in the indicated orientation |
|---|---|
| Power supply + | Right contact OPEN = +12 V DC, maximum 40 mA. Connect the positive power supply wire of a compatible optical safety edge here. |
| Power supply − | Right contact STOP = GND (−). |
| Signal | Left contact STOP = SIGNAL. This is not the positive power supply terminal. |
When connecting an OSE edge, the OPEN contact is used to power the edge—do not use it for an arbitrary push-button connection. NO/NC contacts and resistive safety edges have no power polarity; optical safety edges do. For the required safety category, choose a suitable optical or 8.2 kΩ device and test the complete gate.
Initial startup and device recognition
All the following buttons and LEDs are on the main TN2010L. This procedure is not performed separately on the TN2020L. Before startup, complete the installation and safety protections, and set L8 according to the number of motors.
- After switching on, check the BlueBUS LED: following the initial rapid flashing, it should flash regularly about once per second. The LEDs on the connected TX/RX units should indicate operation; the warning light and auxiliary light should remain off when idle.
- If the indicators are incorrect or a fault is suspected, disconnect the power and check the wiring. Do not proceed with the learning procedure blindly.
- Press and hold ▲ + STOP/SET. Release them when L1 and L2 start flashing rapidly, after about 3 seconds.
- Wait for the procedure to finish. The STOP LED should remain lit and L1/L2 should go out; L3/L4 may flash to indicate that position learning is required.
Recognition is performed even when no devices are connected and again after any change to BlueBUS or STOP.
Position learning and automatic force measurement
First check that the direction of movement is correct and that the area is clear. If the direction is reversed, use direction programming; do not swap the motor wires at random. While the gate is moving, any of the three control-board buttons stops the motor.
Quick procedure – fully open and fully closed positions
- Hold STOP/SET + ▼ for about 3 seconds, until L1 starts flashing, then release the buttons.
- Use ▲ / ▼ to set the required fully open position FCA.
- Hold STOP/SET for 5 seconds and wait for L8 to start flashing; then release the button.
- Use ▲ / ▼ to set the fully closed position FCC.
- Confirm by holding STOP/SET for 2 seconds then release. L1/L8 go out. The control unit calculates the other positions.
- The auxiliary light starts flashing about once per second. Send an SbS or OPEN command: the system will perform two complete automatic force-measurement cycles.
Full setup of individual positions
Enter the procedure in the same way by holding STOP/SET + ▼ for about 3 seconds. Set each position using ▲ / ▼ and confirm each position to be stored with STOP/SET for 2 seconds. An optional position can be skipped by pressing STOP/SET twice in quick succession.
| Sequence / LED | Position and function |
|---|---|
| 1 – L1 / FCA | Fully open position; required. |
| 2 – L2 / RA | Start of deceleration when opening; optional. |
| 3 – L4 / RI | Intermediate deceleration when closing. The gate starts slowing down about 50 cm before this point and returns to the set speed after passing it; optional. |
| 4 – L5 / AP | Partial opening; optional. |
| 5 – L7 / RC | Start of deceleration when closing; optional. |
| 6 – L8 / FCC | Fully closed position; required. |
After FCC, release STOP/SET and send a command to start the two complete force-measurement cycles. The process must finish automatically without interruption. If interrupted, the process remains incomplete even after a power failure and must be started again. Changing the positions, opening/closing speed or direction of rotation triggers a new force-measurement requirement.
The encoder operates within the permitted range of 5–95%. If L1 or L8 flashes by itself while idle, this may indicate that the range has been exceeded; it does not automatically mean there is a photocell fault. Correct the issue without bypassing the safety protection.
Safety tests before use
- With the power disconnected and the motors released, check manual movement; the test limit is 225 N, while the stricter limit for preparing a private gate is 150 N.
- Test each photocell, sensitive safety edge, STOP input and other safety device separately. The response must match the selected function.
- Test the photocells with an object 5 cm in diameter and 30 cm long, at the TX, RX and the centre of the beam.
- When closing onto an object 50 mm placed on the floor, the drive must, when the bottom edge makes contact, reverse the direction of movement. During the safety test with a weight of 20 kg attached to the centre of the bottom edge, the drive must prevent opening or stop the opening movement. Conduct tests with the test area secured; this is not a test of manual release with a weight.
- Measure impact forces and check operational risks for the entire gate. Do not use increased force to mask friction or poor balance.
- Provide the instructions, maintenance plan, test documentation and guidance on releasing the drive. The gate may only be used after the tests have been passed successfully.
Settings on the main TN2010L
▲ opens or moves up through the menu, ▼ closes or moves down through the menu, and STOP/SET stops and confirms. All three buttons stop movement while the gate is moving. The procedures apply to the control unit shown; do not allow more than 10 s to elapse between programming steps.
Level I – eight ON/OFF functions
- With the gate stopped, press and hold STOP/SET for about 3 s, then release when L1 flashes.
- Use ▲ / ▼ to select the function LED.
- Press STOP/SET briefly to change the state: a short flash = OFF; a long flash = ON.
- Wait 10 s for the setting to be saved and the menu to close.
These functions are disabled by default. For a two-motor setup, enable L8.
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After opening, the gate closes after the set pause. When disabled, operation is semi-automatic. |
| L2 | Closing after photocell activation | After the photocell is cleared, there is a 5 s pause. Without L1, the gate completes opening first; with L1, opening may end when the photocell is cleared. This function does not apply after a STOP command. |
| L3 | Always close | When power is restored, the control unit detects if the gate is open and starts closing with a 3 s pre-flash warning. |
| L4 | Standby | After 1 minute of inactivity, the BlueBUS output and all LEDs are switched off, except the BlueBUS LED, which flashes more slowly. A new command restores operation; the auxiliary 24 V supply remains active. |
| L5 | Long reverse movement | After a STOP command or force limiter activation, the gate reverses all the way to the end position. OFF means a short reverse movement of about 15 cm. |
| L6 | Pre-flashing | The warning light starts flashing 3 s before movement. |
| L7 | Sensitivity | Increases sensitivity to obstacle detection. Requires suitable speed and force settings, followed by measurement. |
| L8 | Two motors | ON: TN2010L + TN2020L. OFF: one TN2010L. |
Level II – eight adjustable parameters
- Press and hold STOP/SET for about 3 s, release when L1 lights up, then use ▲ / ▼ to select the parameter's entry LED.
- Press and hold STOP/SET. After about 3 s, the current value lights up.
- While holding STOP/SET, change the value using ▲ / ▼.
- Release STOP/SET and wait 10 s for the menu to close.
Bold values indicate the table's defaults for the control unit shown; always check the actual setting on the control board LEDs. The pause time applies only when automatic closing is enabled. For parameters with a value between two levels, two LEDs may flash alternately.
| Parameter | Values L1–L8 |
|---|---|
| L1 – Pause time | L1 10 s L2 20 s L3 40 s L4 60 s L5 80 s L6 120 s L7 160 s L8 200 s |
| Parameter | Values L1–L8 |
|---|---|
| L2 – Step-by-step function | L1 open–stop–close–stop L2 open–stop–close–open L3 open–close–open–close L4 residential mode L5 residential mode 2; a command lasting longer than 2 s stops the gate L6 step-by-step mode 2; a command shorter than 2 s opens the gate partially L7 movement while the command is held L8 semi-automatic opening, closing while the command is held |
| Parameter | Values L1–L8 |
|---|---|
| L3 – Speed | L1 30% L2 44% L3 58% L4 72% L5 86% L6 100% L7 opening V4 / closing V2 L8 opening V6 / closing V4 |
| Parameter | Values L1–L8 |
|---|---|
| L4 – FLASH output | L1 gate-open indicator L2 active when the gate is closed L3 active when the gate is open L4 warning light L5 electric locking L6 electric lock L7 holding magnet L8 maintenance indicator |
| Parameter | Values L1–L8 |
|---|---|
| L5 – Opening force | L1 force 1 L2 force 2 L3 force 3 L4 force 4 L5 force 5 L6 force 6 L7 force 7 L8 force 8 |
| Parameter | Values L1–L8 |
|---|---|
| L6 – Closing force | L1 force 1 L2 force 2 L3 force 3 L4 force 4 L5 force 5 L6 force 6 L7 force 7 L8 force 8 |
| Parameter | Values L1–L8 |
|---|---|
| L7 – Maintenance reminder | L1 automatic, based on operating conditions L2 1,000 cycles L3 2,000 cycles L4 4,000 cycles L5 6,000 cycles L6 8,000 cycles L7 10,000 cycles L8 12,000 operations |
| Parameter | L1–L8 values |
|---|---|
| L8 – Fault history | L1 most recent operation L2 second most recent operation L3 third most recent operation L4 fourth most recent operation L5 fifth most recent operation L6 sixth most recent operation L7 seventh most recent operation L8 eighth most recent operation |
Force is not a way to overcome a gate fault. After changing the force, repeat the protective-force measurement; after changing the speed, also repeat automatic force learning. Output FLASH changes function and the required load according to the selected mode; it is not a universal 24 V power supply. The flashing light and lock must not be connected to it at the same time. For L6, use an electric lock 24 V, max. 10 W, and for L7, a holding magnet 24 V, max. 10 W; both must be electromagnetic, with no built-in electronics. The L6 lock is released by a short pulse during opening; the L7 magnet holds the gate closed and switches off while the gate is moving. In L5 electric locking mode, the latch remains released while the gate is opening; confirm the latch selection and permissible current draw for the installed board. The latch must be rated at no more than 24 V and be electromagnetic, with no built-in electronics. When closing, the latch must mechanically engage again.
Other commands
A continuous SbS command lasting more than 3 s can keep the gate open, for example when using a suitable timer contact. Emergency movement when a safety device has failed is possible only under control while holding down the command: after an unsuccessful command, repeat it within 3 s and keep holding it; movement starts after about 2 s and stops when you release the command. This mode does not replace repairs and must only be used under supervision, with no people or objects in the gate’s path.
Receiver, remote controls and antenna
The TN2010L has an SM socket for a separate receiver. The TN2020L has no built-in receiver; it is controlled through the master motor. The current selection is NICE OXIBD; the remote control type must match the receiver’s encoding. Existing installations may use SMXI, SMXIS or OXI; follow the receiver’s instructions to pair radio remote controls.
Disconnect the mains supply and backup power before inserting or removing the receiver. With OXIBD, connect the external antenna directly to the receiver’s antenna terminals, connecting the signal and shield as shown in its instructions. Do not automatically connect it to the board’s older Aerial terminal just because it is shown in the original diagram. Extended commands for the OXI/OXIBD receiver and pairing NICE remote controls.
| Receiver’s basic output | TEN master command |
|---|---|
| 1 | Step-by-step (SbS) |
| 2 | Partial opening |
| 3 | Open |
| 4 | Close |
In extended mode, OXI also supports Stop, apartment-block and priority step-by-step commands, additional partial openings, open/close with lockout, lockout/unlock, and timed or continuous courtesy light. Select the available functions according to the receiver and its own instructions. A suitable OView interface can be used for programming and diagnostics via BusT4; it is not a second control motor.
Backup power
The backup power unit connects to the master TN2010L, which controls the entire two-motor system from the backup supply. Do not connect the battery directly to the TN2020L motor or to the auxiliary STOP/SbS output.
The current TEN catalogue lists the NICE PSS324. It has its own connector and requires a compatible control-system generation and the correct connecting cable. The original NICE PS324 is an older, discontinued version; for existing installations, follow its original wiring. The old and new connectors, and their charging controls, are not automatically interchangeable. Check the board and battery labels before replacing them.
Install the battery with the system disconnected and use the designated keyed connector; do not force it into place. After installation, test a complete cycle on mains power and on backup power, then restore the mains supply. The number of operations depends on the gate, number of motors, temperature, and battery condition and age. The gate may move more slowly during a power outage. The emergency release must remain accessible even when the battery is flat.
Diagnostics and common faults
When a fault occurs, the flashing light and courtesy light repeat a group of rapid flashes twice, with a 1 s pause between groups. Count the flashes in one group. Normal flashing of the warning light while the gate is moving is not this fault code.
| Flashes | Cause | What to check |
|---|---|---|
| 2 | Photocell is preventing movement | Check for obstructions, the optics, wiring and addressing. |
| 3 | Force limit triggered | Check for obstructions, friction and balance. Do not increase the force automatically. |
| 4 | STOP triggered | Check the safety edge, contacts and the learned STOP input type. |
| 5 | Internal parameter fault | Wait at least 30 s, then try a command. If the fault recurs, have the control board serviced. |
| 6 | Hourly operation limit exceeded | Wait a few minutes for the thermal/operating limit to reset. |
| 7 | Internal circuit fault | Disconnect all power sources for a few seconds; if the fault recurs, arrange servicing and have the motor/cables checked. |
| 8 | Another command is already active | Cancel any continuous or simultaneous command. |
| 9 | Automation locked | Unlock it with the appropriate receiver command; do not confuse this with mechanical release. |
Control-board LEDs and courtesy light
First distinguish Stand-by mode from a fault. When Stand-by is enabled, after one minute without activity the other LEDs go out and the BlueBUS LED flashes more slowly. Before assessing the LEDs, wake the control unit with a command only if the path is clear and safe; be prepared for the gate to move. The following table applies when the control unit is awake.
| Indicator | Meaning |
|---|---|
| BlueBUS: green, once per second | Normal operation. Two quick green flashes = input change or command received. |
| BlueBUS: off / continuously lit | Check the power supply and fuses / fault requiring the control board to be checked. |
| BlueBUS: quick and long red flashes | BlueBUS short circuit. Disconnect and check the wiring; after the fault is cleared, normal flashing may take about 10 s to resume. |
| STOP: lit / off | Normal after learning / safety input activated or faulty. |
| SbS, OPEN, CLOSE | An illuminated LED indicates that the corresponding command is active. |
| L1 + L2 flashing | The connected devices need to be recognised. |
| L3 + L4 flashing | The gate positions need to be learned. |
| L1 or L8 flashing on its own while idle | L1 = upper limit, position ≥95%; L8 = lower limit, position ≤5%. Adjust the position and repeat the learning procedure; do not use the workshop encoder reset on a gate that is already installed. |
| L1–L8 during movement | Current motor load; L1 low, L8 high. This is not the same as the relative force setting in the menu. |
| Auxiliary light flashes once per second | Automatic force learning is incomplete; if an error flash is also present, count the fault code. |
If the remote control does not respond and its LED is off, check the battery. If the LED is lit, check the receiver and pairing. If the control board is completely unresponsive, check the mains supply and fuses; replace a fuse only after resolving the cause, using the same type and rating as specified on the label. If the gate moves briefly and then reverses, first check for resistance in the gate, not just the force setting.
Maintenance warning during normal operation
A beacon that stays lit for longer may indicate that maintenance is due. This is not the same signal as the rapid groups of flashes indicating a fault. Applies when the FLASH output is configured accordingly; the maintenance indicator is an alternative mode of the same output.
| Maintenance threshold reached | Beacon in FLASH mode | Output in maintenance indicator mode |
|---|---|---|
| Less than 80% | Normal flashing: on for 0.5 s / off for 0.5 s. | Lights up for 2 s at the start of opening. |
| 81–100% | On for 2 s at the start of the cycle, then flashes normally. | Flashes throughout the entire cycle. |
| More than 100% | On for 2 s at the start and end of the cycle; otherwise flashes normally. | Flashes continuously. |
Have the warning addressed by a qualified maintenance professional; do not reset the counter just to stop the signal.
History of the last eight cycles
- Hold STOP/SET for about 3 s, release when L1 lights up, then select input LED L8.
- Hold STOP/SET and wait about 3 s. Lit LEDs indicate cycles with a fault: L1 is the most recent, L8 the eighth most recent. An LED that is off indicates a cycle without a fault; the history is read-only.
- While holding STOP/SET, use ▲ / ▼ to select a cycle. The LED flashes the corresponding code from the table.
- Release STOP/SET.
Reset, motor direction and maintenance counter
Erasing the main control unit’s memory
A reset erases learned devices, positions and user settings. After resetting, select the number of motors again, repeat the learning procedure and carry out the tests; this is not a standard way to resolve a mechanical fault.
- With the motor stopped, hold ▲ + ▼, until all LEDs L1–L8 light up, for about 3 s.
- Release the buttons. The LEDs flash rapidly for about 3 s and the control unit restarts.
- At the end, L1/L2 flash. Repeat the device recognition, L8 configuration and position and force learning.
This reset does not change the set rotation direction or encoder position. The plug-in radio receiver’s memory is managed separately, as described in its instructions.
Changing the rotation direction
- With the gate stopped, hold STOP/SET for about 3 s and release when L1 flashes.
- Briefly press ▲ + ▼ together and release.
- The auxiliary light on indicates the reversed direction; off indicates the standard direction.
- Wait 10 s for the procedure to finish. Then repeat position learning and automatic force learning.
Restoring the encoder position
Resetting the encoder position is strictly a workshop procedure performed on a workbench. Never perform it with the motor installed on the gate. It sets the encoder to installation position L6 and restores the control unit’s default settings at the same time. If required, it must be carried out by a service technician in accordance with the full installation manual; it is not a substitute for learning the positions of an installed gate.
Reading and resetting the maintenance counter
Level II, input LED L7: hold STOP/SET and wait about 3 s for the level to appear. Briefly press ▲ + ▼ to read the counter: each flash represents 10% of the set limit. For example, four flashes at a limit of 10,000 indicate 4,000–4,999 cycles. Holding ▲ + ▼ for at least 5 s resets the counter; do this only after maintenance has been completed. Then release STOP/SET.
Maintenance and safe use
Professional maintenance at least every 6 months or 4,000 operating cycles, whichever comes first. Shorten the interval as appropriate if the gate is operated frequently. The counter warning does not replace the time-based maintenance interval.
- Before working on the system, disconnect the mains supply and battery, and secure the gate against movement.
- Check the fixings, shafts, telescopic arms, cables, springs and tracks for corrosion and wear. Replace damaged parts; spring adjustment must be carried out by a qualified professional.
- After maintenance, restore the power supply and repeat the safety tests. Document the result.
- Users may clean the photocell optics with a slightly damp cloth and remove debris from the gate’s path. Do not use the gate if it is faulty; contact the installer.
Pass through only when the gate is fully open and stationary. Keep children and remote controls away from moving parts. As specified in the installation instructions, check monthly that when closing against an object of height 50 mm placed on the floor, the drive reverses after the bottom edge makes contact. If it does not work correctly, stop automatic operation and arrange a service visit. The drive and batteries must not be disposed of with household waste; arrange for them to be removed and sent for recycling.
Estimated service life
Add the relevant weight and force indices and other applicable factors; include the latter factors if the probability of their occurrence exceeds 10%. The weight in this table is an input for estimating wear, not a load capacity or permission to automate a gate of any weight. Installation and operating limits take precedence.
| Characteristics of the complete automation system | Index | Service life chart |
|---|---|---|
| Factor | TN2010L + TN2020L | The horizontal axis shows the sum of the indices in %, and the vertical axis shows the number of complete cycles. |
| Gate weight up to 100 kg | 10% | |
| Over 100–180 kg | 20% | |
| Over 180–230 kg | 30% | |
| Over 230 kg | 50% | |
| Movement force up to 160 N | 5% | |
| Over 160–240 N | 15% | |
| Over 240–290 N | 30% | |
| Over 290–350 N | 50% | |
| Temperature above 40 °C / below 0 °C or humidity above 80% | 10% | |
| Dust or sand | 15% | |
| Saline environment | 20% | |
| Photocell interruption | 10% | |
| STOP interruption | 20% | |
| Speed above level L4 | 15% |
The graph of approximately 10,000–50,000 cycles is an indicative estimate assuming proper maintenance, not a guarantee of service life or a number of years. It does not simply count the number of openings and does not indicate a service interval.
NICE TN2020L technical specifications
| Intended use | Second motor without a control unit; controlled by the main TN2010L. |
|---|---|
| Power supply | 24 V DC −30/+50% from the main unit's output; not 230 V. |
| Max. starting torque | 320 Nm |
| Rated torque | 220 Nm |
| No-load speed | 1.4 rpm at 24 V DC. |
| Speed at rated torque | 0.9 rpm at 24 V DC. |
| Max. power consumption during startup | 130 W / 5.5 A at 24 V DC. |
| Motor weight | 7.2 kg |
| Ingress protection and environment | IP44; install inside the garage. |
| Operating temperature | −20 to +50 °C |
| Overall dimensions | Height 512 mm, width 150 mm, depth according to drawing 160 mm; tabulated body depth 158 mm. |
| Auxiliary light | Built-in LED lighting. |
| Insulation class | III |
For the complete TN2010L + TN2020L assembly, the manual specifies starting torque of 500 Nm, rated torque of 330 Nm, and power consumption of 350 W / 1.4 A from the mains and a combined weight of both motors of 17.2 kg. The torque of the assembly is not determined by simply adding the torques of the individual motors.
For the TN2010L + TN2020L assembly, operation at rated load is limited to 25 cycles/h and 14 minutes of continuous operation. At +50 °C, these values are reduced to 4 cycles/h and 7 minutes for the complete two-motor assembly. The load tables and control system further limit actual operation. Basic technical values apply at 20 °C ±5 °C.
To verify your selection contact us with the gate type, height and width, balancing method, and expected number of cycles. For a replacement, include a photo of the label and control board.