NICE Ten TN2010L – operator for up-and-over garage doors
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
for the question
€563.92 including VAT
| Weight |
|---|
| 10 kg |
Description of NICE Ten TN2010L – operator for up-and-over garage doors
NICE TEN TN2010L – operator for an up-and-over garage door
The NICE TN2010L operator is designed for up-and-over garage doors. Before ordering, check the door’s dimensions, weight and construction.
The TN2010L features a built-in control unit, an absolute encoder and auxiliary LED lighting. It can also control a connected second motor NICE TN2020L. The operator is non-reversible; in the event of a power failure, it allows manual release using the handle.
When to choose this operator
The TEN is designed for properly balanced up-and-over garage doors with counterweights or springs, with or without an overhang. The motor is mounted on the door structure and transfers movement via shafts and telescopic arms. It is not a ceiling-mounted operator with a guide rail for a sectional door.
The TN2020L is an additional motor, not a standalone replacement for the TN2010L. Accessories, the receiver, safety inputs and settings for a two-motor setup are all handled by the main TN2010L unit. If you already have a different main control unit, check the exact combination and consult its own manual.
| Configuration as shown in the supplied installation manual | Approximate door dimensions |
|---|---|
| 1 × TN2010L | Maximum height 2.6 m, maximum width 3 m; area up to 8 m². |
| 1 × TN2010L + 1 × TN2020L | Maximum height 2.6 m, maximum width 5.4 m; area up to 14 m². |
Dimensions alone are not enough: balance, resistance throughout the full travel and the number of cycles all matter. The installation limits stated above apply to the configuration shown in the supplied manual. A larger door must be assessed individually for the specific motor and control unit. A second motor does not replace repairs to damaged springs, cables or guides.
Cycle count and force required to move the door
| Configuration | Force required to move the door | Max. cycles/hour | Max. consecutive cycles |
|---|---|---|---|
| TN2010L | Up to 120 N | 20 | 35 |
| TN2010L | Over 120–180 N | 18 | 33 |
| TN2010L | Over 180–220 N | 15 | 30 |
| TN2010L + TN2020L | Up to 150 N | 30 | 19 |
| TN2010L + TN2020L | Over 150–250 N | 28 | 16 |
| TN2010L + TN2020L | Over 250–350 N | 25 | 14 |
A cycle means one complete opening and closing; a manoeuvre is movement in one direction. These are maximum operating limits, not a recommendation to increase the door’s resistance. When preparing the door for private use, the force required to move it manually must not exceed 150 N; the manual movement test during commissioning has a separate limit of 225 N. The control unit limits operation according to load and duration to prevent overheating.
Motor and control for the configuration
| Configuration component | Role in door automation |
|---|---|
| NICE TN2010L | Main motor with built-in control unit, absolute encoder and BlueBUS. Controls the safety devices, receiver and connected second motor. The plug-in receiver is selected separately. |
| NICE TN2020L | A second 24 V DC motor without a control unit. For a two-motor installation, it connects to the main TN2010L; it cannot operate the door on its own. |
Standalone motor and required installation hardware
This product page is for the TN2010L. A complete automation system also requires a support bracket, suitable shafts, telescopic arms, controls and safety devices. The choice depends on the door structure and the number of motors. Before ordering, check the included equipment and any additional accessories required.
Installation component labels:
- A – TEN motor
- B – M6 nuts
- C – M8 nuts
- D – M6 × 14 threaded studs
- E – Ø8 washers
- F – M8 × 110 screws
- G – release rod.
| What | Why | Type |
|---|---|---|
| Support bracket | Motor support bracket, length 1 250 / 2 000 mm. | |
| Shafts | 20 × 20 mm square-section shafts, length 1 500 / 200 mm. | |
| Telescopic arms | Pair of straight / angled telescopic arms. Angled arms help when space is limited near the gate support arm. | |
| Shaft guide | Guide for a pair of drive shafts. | |
| External release | Release from outside using a cable / key lock. OTA12 is not used with motors mounted on the side. |
Gate installation and inspection
Install the motor inside the garage. IP44 protection rating does not permit outdoor installation. Disconnect the mains and any backup battery before carrying out work.
- Check the condition and balance of the gate, springs, cables, guides and supporting components. The gate must move smoothly by hand along its entire travel and must not drop on its own.
- Remove any unnecessary cables and disable the original locking mechanism if it would obstruct motorised movement.
- Select a rigid bracket and shafts to suit the gate width. Before fully tightening, check the full travel of the shafts and telescopic arms; they must not collide with the guide, frame or counterweight.
- Assess potential crushing points around the arms, top edge and bottom edge. If the gate has a wicket door, its opening must be safely monitored.
- The manual release must be reachable up to a height of 1.8 m. Install the fixed control device within sight of the gate, away from moving parts, at least 1.5 m above floor level.
- If there is no other entrance to the garage, install an external release before handover. The moving gate must not extend onto a public footpath or roadway.
Diagram:
- 1 – TEN
- 2 – 20 × 20 mm square shaft
- 3 – support bracket
- 4 – telescopic arm
- 5 – photocells
- 6 – photocells on posts
- 7 – safety edge
- 8 – low-voltage flashing beacon with antenna
- 9 – control device.
This shows a typical layout; safety devices must be designed for the actual gate.
Motor dimensions and cable routing
The drawing shows a height of 512 mm, a width of 150 mm, a maximum depth of 160 mm and a shaft output of 20 × 20 mm. Before mounting, also allow space for the cover, release mechanism and gate movement. The technical table lists the housing depth as 158 mm; allow for the 160 mm outline shown in the drawing when planning the space.
With the cover open, prepare only the cable entries required and use suitable cable glands. Keep mains wiring separate from low-voltage cables, secure them against tension and leave enough slack for gate movement. There must be no water or condensation in the conduits or at the entry points. After adjustment, fit the cover and check that it clears the gate throughout its travel.
Manual release and re-engagement
Release only when the gate is stopped, and first secure it against falling. An unbalanced gate or damaged spring may cause sudden movement when released. For a two-motor system, release both motors.
- Stop the gate and disconnect all power sources.
- Turn the motor handle counterclockwise as shown in the illustration. Then move the gate by hand without forcing it.
- To re-engage the drive, turn the handle clockwise to the vertical position.
- Move the gate briefly by hand until the gearbox engages. Only then restore power and check the controls.
For external release, use suitably installed NICE OTA11 or NICE OTA12. For a two-motor system, the solution must allow both drives to be safely released.
Wiring
| Main TN2010L circuit | Routing and length as specified in the instructions |
|---|---|
| Mains supply | 3 × 1,5 mm², max. 30 m. For lengths over 30 m, use a larger cross-section, for example 3 × 2,5 mm², as determined by the power supply and protection design. |
| 12 V flashing beacon | 2 × 1 mm², max. 20 m. |
| Antenna | RG58 coaxial cable, max. 20 m; recommended length under 5 m. |
| BlueBUS photocells | 2 × 0,5 mm², max. 20 m. |
| Key switch | Max. 20 m; number of cores depends on the contacts used. The instructions allow a shared 4 × 0,5 mm² cable. |
| Contact safety edge | 2 × 0,25 mm², max. 20 m; an optical edge requires wiring according to its three signals. |
Cables must be suitable for the environment and moving installation. Plan the route, protection and supply cable; simply observing the stated cross-section is not enough. Between the motors there are two separate circuits – motor and auxiliary light; select the wiring according to the supplied system and the diagram below.
Control unit and wiring
TN2010L has a built-in control unit; TN2020L does not. The terminals and procedures listed below apply to the TN2010L control unit shown in the picture, with three buttons and eight LEDs, L1–L8. When replacing the NICE TNA2 board or if using a different version, follow the instructions for the version actually installed.
On the board:
- a – terminals
- b – buttons
- c – LEDs L1–L8
- d – input LEDs
- e – auxiliary light
- f – fuse F2
- g – SM receiver socket
- h – BusT4
- i – Aerial terminal
- l – battery connector.
Mains and low-voltage accessories
| Circuit / terminals | Wiring and limits |
|---|---|
| TN2010L: 1 / 2 / 3 | Mains 230 V AC, 50/60 Hz: 1 = L (live), 2 = N (neutral), 3 = PE (protective earth). AC has no positive or negative terminal. The supply must have suitable disconnection and protection. |
| Auxiliary power supply | Right-hand STOP contact = GND (−), left-hand SbS contact = 24 V DC (+), when oriented the same way as in the picture. Voltage 24 V DC −30/+50%, up to 100 mA total. Remains on in Stand-by. |
| BlueBUS | Parallel two-wire connection for compatible devices, e.g. NICE EPMB. No polarity; this is not a general-purpose 24 V auxiliary output. Up to 12 BlueBUS load units. |
| SbS / Open / Close | Command pairs for volt-free NO contacts: step-by-step / open / close. Switch the relevant pair of contacts; do not connect an external power supply. An NO contact has no polarity. |
| Stop | Configurable safety input: NO, NC, 8.2 kΩ or compatible optical safety edge; see detailed STOP wiring. |
| Flash | Factory-configured output for a 12 V DC warning light, max. 21 W, e.g. NICE ELDC. Do not connect a 230 V ELAC here. Use the markings on the installed board to identify the exact output polarity; do not infer it from the auxiliary power supply. |
| Aerial / receiver | Coaxial cable: centre conductor = signal, braid = shield. These are not power supply +/− terminals. With the NICE OXIBD connect the external aerial directly to its aerial terminals. |
The positive and negative labels above refer to individual contacts, not to the two-pole terminal blocks as a whole. Connect powered accessories with their + to SbS (+) and − to STOP (−), only if their voltage and total current draw are within the specified limits. Do not power the TN2020L motor or the warning light from this 100 mA output.
The diagram shows alternative wiring configurations for safety devices; this does not mean that all STOP options should be connected at the same time. For the warning light NICE ELDC connect the power supply to its designated low-voltage input and wire the aerial cable separately. Set the flashing mode according to the warning light instructions for an output that already provides an intermittent voltage.
Connecting the TN2010L and TN2020L
The 230 V mains supply must be connected only to the main TN2010L. The TN2020L receives motor power from the main unit. It has its own motor and light terminals, but no second control unit or separate safety inputs.
| Connections as shown | Requirements |
|---|---|
| A – second motor | Connect the TN2010L second-motor output to the TN2020L motor terminals. For both pairs shown, left −, right +; maintain − to − and + to +. |
| B – second motor auxiliary light | Run a separate cable from the second-motor light output to the TN2020L light terminals. Again, in the picture, left −, right +; do not connect to the motor terminals or the 100 mA auxiliary output. |
| Settings on the main TN2010L | Level I, L8 ON = two motors; with only one TN2010L, L8 must remain OFF. |
Read the pole positions with the original diagram oriented the same way, and always check them against the actual terminal markings. Do not enable two-motor mode when only one motor is installed – this can cause malfunction and damage. After changing the configuration, repeat the learning procedure, force measurement and safety tests.
BlueBUS photocells and addressing
NICE EPMB connect using two wires to the BlueBUS on the main TN2010L. The TX and RX of one pair have the same jumpers; the next pair is assigned a different address. BlueBUS devices are non-polarized and are connected in parallel. Standard EPM relay devices must not be connected to BlueBUS.
| Address | Function with TEN |
|---|---|
| PHOTO / PHOTO II | Detection while closing; height approximately 50 / 100 cm. |
| PHOTO 1 / PHOTO 1 II | Detection while opening and closing; height approximately 50 / 100 cm. |
| PHOTO 2 / PHOTO 2 II | Detection while opening. |
| PHOTO 3 | One photocell safety device covering the entire automation system, as specified in the proposed configuration. |
| FA1 / FA2 | Photocell for the opening command; use only with a suitable photocell type and in accordance with its instructions. It does not replace the required safety protection. |
When replacing photocells, check that the jumpers have the same meaning in their own instructions. After each device is added or removed, perform device recognition and test the response in both directions again. Do not test movement with the safety device bypassed. EPMB jumper settings.
Sensitive safety edge and STOP input
STOP triggers a stop followed by a brief reverse movement. During setup, the control unit stores the type of connected device and triggers a safety response when its state changes. Multiple NO contacts can be connected in parallel and NC contacts in series. Resistive safety edges are wired according to their instructions; for a cascade connection, use a single terminating resistor 8.2 kΩ.
| OSE optical edge | Specific contact when viewed in the orientation shown |
|---|---|
| Power + | Right contact OPEN = +12 V DC, maximum 40 mA. Connect the positive power wire of a compatible optical edge here. |
| Power − | Right contact STOP = GND (−). |
| Signal | Left contact STOP = SIGNAL. This is not the positive power terminal. |
With OSE wiring, the OPEN contact is used to power the safety edge—do not use it for arbitrary push-button wiring. NO/NC contacts and resistive safety edges have no power polarity; optical edges do. For the required safety category, select a suitable optical or 8.2 kΩ device and test the entire gate.
Initial startup and device recognition
All the following buttons and LEDs are on the main TN2010L. This procedure is not performed separately on the TN2020L. Before startup, complete the installation, safety devices and L8 setting according to the number of motors.
- After switching on, check the BlueBUS LED: after an initial rapid flash, it should flash regularly about once per second. The LEDs on the connected TX/RX units should indicate operation; the warning light and auxiliary light should remain off when idle.
- If the indicators do not behave as expected or a fault is suspected, disconnect the power and check the wiring. Do not proceed with setup blindly.
- Press and hold ▲ + STOP/SET. Release them when L1 and L2 start flashing rapidly, after approximately 3 seconds.
- Wait for completion. The STOP LED should remain lit and L1/L2 should go out; L3/L4 may flash to indicate that position learning is required.
Recognition is performed even when no devices are connected and must be repeated after a change to BlueBUS or STOP.
Position learning and automatic force calibration
First check that the movement direction is correct and the path is clear. If the direction is reversed, use direction programming; do not swap the motor wires at random. While the gate is moving, any of the three control-board buttons will stop the motor.
Quick procedure – open and closed positions
- Press and hold STOP/SET + ▼ for approximately 3 s, until L1 starts flashing, then release the buttons.
- Use ▲ / ▼ to set the fully open position FCA.
- Press and hold STOP/SET for 5 s and wait for L8 to start flashing; then release the button.
- Use ▲ / ▼ to set the fully closed position FCC.
- Confirm by pressing STOP/SET for 2 s and release. L1/L8 go out. The control unit calculates the other positions.
- The auxiliary light starts flashing about once per second. Give an SbS or OPEN command: the system will perform two complete automatic force-calibration cycles.
Full procedure for setting individual positions
Enter the procedure in the same way, by pressing STOP/SET + ▼ for approximately 3 s. Set the position using ▲ / ▼ and confirm each position to be stored by pressing STOP/SET for 2 s. An optional position can be skipped by pressing STOP/SET twice quickly.
| Order / LED | Position and description |
|---|---|
| 1 – L1 / FCA | Fully open position; mandatory. |
| 2 – L2 / RA | Start of deceleration while opening; optional. |
| 3 – L4 / RI | Intermediate deceleration while closing. The gate starts slowing down about 50 cm before this point and returns to the set speed after passing it; optional. |
| 4 – L5 / AP | Partial opening; optional. |
| 5 – L7 / RC | Start of deceleration while closing; optional. |
| 6 – L8 / FCC | Fully closed position; mandatory. |
After FCC, release STOP/SET and issue a command to run two complete force-calibration cycles. The process must finish on its own without interruption. If interrupted, it remains incomplete even after a power failure and must be started again. Changing positions, opening/closing speed or rotation direction triggers a new force-calibration requirement.
The encoder operates within the permitted range of 5–95 %. If L1 or L8 flashes on its own while idle, this may indicate that the range has been exceeded; it does not necessarily mean there is a photocell fault. Correct the issue without bypassing the safety device.
Safety checks before use
- With the power disconnected and the motors released, check manual movement; the test limit is 225 N, while the limit for preparing a private gate is stricter at 150 N.
- Test each photocell, sensitive edge, STOP input and other safety device separately. The response must match their selected function.
- Test the photocells with an object Ø5 cm in diameter and 30 cm long at TX, RX, and the centre of the beam.
- When closing onto an object 50 mm placed on the floor, the drive must, upon contact with the bottom edge, reverse its direction of travel. During the safety test with a weight of 20 kg attached to the centre of the bottom edge, the drive must prevent opening or stop the opening movement. Carry out the tests with the test area secured; this is not a test of manual release with a weight.
- Measure impact forces and assess the operating risks of the entire gate. Increasing the force must not conceal friction or poor balance.
- Provide the instructions, maintenance plan, test documentation, and guidance on releasing the mechanism. The system may be operated only after the tests have been passed.
Settings on the TN2010L control unit
▲ opens or scrolls up through the menu, ▼ closes or scrolls down, and STOP/SET stops and confirms. During movement, all three buttons stop the gate. These procedures apply to the control unit shown; do not allow more than 10 s to pass between programming steps.
Level I – eight ON/OFF functions
- With the gate stopped, hold STOP/SET for approximately 3 s and release when L1 flashes.
- Use ▲ / ▼ to select the function LED.
- Press STOP/SET briefly to change the status: a short flash = OFF, a long flash = ON.
- Wait 10 s for the setting to be saved and the menu to exit.
These functions are disabled by default. For a two-motor setup, enable L8.
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | Closes after opening, once the set pause has elapsed. Without this function, operation is semi-automatic. |
| L2 | Closing after photocell activation | 5 s pause after the photocell is cleared. Without L1, the gate completes the opening movement first; with L1, opening may end once the photocell is cleared. This function does not apply after a STOP command. |
| L3 | Always close | When power returns, the control unit detects whether the gate is open and starts closing, with a 3 s pre-flash warning. |
| L4 | Standby | After 1 minute of inactivity, the BlueBUS output and all LEDs are switched off, except the BlueBUS LED, which flashes more slowly. A new command resumes operation; the auxiliary 24 V supply remains active. |
| L5 | Extended reverse movement | After a STOP command or force limiter activation, the gate reverses all the way to the end position. OFF means a short reverse movement of approximately 15 cm. |
| L6 | Pre-flashing | The warning light starts 3 s before movement. |
| L7 | Sensitivity | Increases sensitivity to obstacle detection. Requires suitable speed and force settings, followed by measurement. |
| L8 | Two motors | ON: TN2010L + TN2020L. OFF: one TN2010L. |
Level II – eight adjustable parameters
- Hold STOP/SET for approximately 3 s, release when L1 lights up, then use ▲ / ▼ to select the parameter's entry LED.
- Press and hold STOP/SET. After about 3 s, the current value lights up.
- While holding STOP/SET, change the value using ▲ / ▼.
- Release STOP/SET and wait 10 s for the menu to exit.
Bold values indicate the table's presets for the control unit shown; always read the actual setting from the board LEDs. The pause time applies only when automatic closing is enabled. For parameters with values between two levels, two LEDs may light alternately.
| Parameter | Values L1–L8 |
|---|---|
| L1 – Pause time | L1 10 s L2 20 s L3 40 s L4 60 s L5 80 s L6 120 s L7 160 s L8 200 s |
| Parameter | Values L1–L8 |
|---|---|
| L2 – SbS function | L1 open–stop–close–stop L2 open–stop–close–open L3 open–close–open–close L4 apartment block mode L5 apartment block mode 2; a command lasting more than 2 s stops the gate L6 step-by-step mode 2; a command lasting less than 2 s partially opens the gate L7 hold-to-run movement L8 semi-automatic opening, closing while the command is held |
| Parameter | Values L1–L8 |
|---|---|
| L3 – Speed | L1 30% L2 44% L3 58% L4 72% L5 86% L6 100% L7 opening V4 / closing V2 L8 opening V6 / closing V4 |
| Parameter | Values L1–L8 |
|---|---|
| L4 – FLASH output | L1 gate-open indicator L2 active when the gate is closed L3 active when the gate is open L4 warning light L5 electric locking L6 electric lock L7 holding magnet L8 maintenance indicator |
| Parameter | Values L1–L8 |
|---|---|
| L5 – Opening force | L1 force 1 L2 force 2 L3 force 3 L4 force 4 L5 force 5 L6 force 6 L7 force 7 L8 force 8 |
| Parameter | Values L1–L8 |
|---|---|
| L6 – Closing force | L1 force 1 L2 force 2 L3 force 3 L4 force 4 L5 force 5 L6 force 6 L7 force 7 L8 force 8 |
| Parameter | Values L1–L8 |
|---|---|
| L7 – Maintenance warning | L1 automatic according to operating conditions L2 1,000 manoeuvres L3 2,000 manoeuvres L4 4,000 manoeuvres L5 6,000 manoeuvres L6 8,000 manoeuvres L7 10,000 manoeuvres L8 12,000 manoeuvres |
| Parameter | Values L1–L8 |
|---|---|
| L8 – Fault history | L1 most recent manoeuvre L2 2nd most recent manoeuvre L3 3rd most recent manoeuvre L4 4th most recent manoeuvre L5 5th most recent manoeuvre L6 6th most recent manoeuvre L7 7th most recent manoeuvre L8 8th most recent manoeuvre |
Force is not intended to overcome gate faults. After changing the force setting, repeat the safety-force measurement; after changing the speed, also repeat the automatic force learning procedure. Output FLASH changes its function and the required load depending on the selected mode; it is not a universal 24 V power supply. Do not connect a beacon and a lock to it at the same time. For L6, use an electric lock 24 V, max. 10 W, and for L7, a holding magnet 24 V, max. 10 W; both must be electromagnetic, with no built-in electronics. The L6 lock is released by a short pulse when opening; the L7 magnet holds the gate closed and switches off while the gate is moving. In L5 electric locking mode, the latch is held released while opening; confirm the choice and permitted current draw of the specific latch, rated at no more than 24 V and electromagnetic with no built-in electronics, against the installed control board. When closing, the latch must mechanically engage again.
Additional commands
A continuous SbS command lasting more than 3 s can keep the gate open, for example when using a suitable timer contact. Emergency movement when a safety device has failed is possible only under controlled conditions while holding the command: after an unsuccessful command, repeat it within 3 s and keep holding it; movement starts after about 2 s and stops when the command is released. This mode does not replace repairs and may only be used under supervision, with no people or objects in the path.
Receiver, remote controls and antenna
TN2010L has an SM socket for a plug-in receiver. TN2020L has no built-in receiver; control is via the main motor. The current selection is NICE OXIBD; the remote control type must match the receiver's encoding. Existing systems may use SMXI, SMXIS or OXI; follow the receiver's instructions for pairing radio remote controls.
Disconnect both the mains power and backup supply before inserting or removing the receiver. For OXIBD, connect the external antenna directly to the receiver's antenna terminals, connecting the signal and shield according to its instructions. Do not automatically connect it to the board's older Aerial terminal just because it is shown in the original diagram. Advanced commands for the OXI/OXIBD receiver and pairing NICE remote controls.
| Basic receiver output | Main TEN command |
|---|---|
| 1 | Step-by-step SbS |
| 2 | Partial opening |
| 3 | Open |
| 4 | Close |
In advanced mode, OXI also supports Stop, apartment-block and priority step-by-step commands, additional partial openings, open/close with lockout, lock/unlock, and timed or continuous auxiliary lighting. Choose the range according to the receiver and its own instructions. A suitable OView interface can be used for programming and diagnostics via BusT4; it is not a second control motor.
Backup power
The backup supply connects to the main TN2010L, which controls the entire dual-motor system from the backup supply. Do not connect the battery directly to the TN2020L motor or to the auxiliary STOP/SbS output.
The current TEN catalogue lists NICE PSS324. It has its own connector and requires a compatible control-system generation and the correct connecting cable. The original NICE PS324 is an older, superseded version; for an existing installation, follow its original wiring. The old and new connectors and their charging controls are not automatically interchangeable. Check the board and battery labels before replacement.
Install the battery with the system disconnected and use the designated keyed connector; do not force it into place. After installation, test a complete cycle using both mains and backup power, then restore mains power. The number of movements depends on the gate, number of motors, temperature, and the battery's condition and age. The gate may move more slowly during a power outage. Emergency manual release must remain accessible even when the battery is flat.
Diagnostics and common faults
When a fault occurs, the beacon and auxiliary light repeat a group of rapid flashes twice, with a 1 s pause. Count the flashes in one group. Normal beacon flashing while the gate is moving is not this fault code.
| Flashes | Cause | What to check |
|---|---|---|
| 2 | Photocell does not permit movement | Check for obstructions, inspect the optics and wiring, and verify the addressing. |
| 3 | Force limit triggered | Check for obstructions, friction and balance. Do not automatically increase the force setting. |
| 4 | STOP input triggered | Check the safety edge, contacts and learned STOP input type. |
| 5 | Internal parameter error | Wait at least 30 s, then try a command. If it recurs, have the control board serviced. |
| 6 | Hourly manoeuvre limit exceeded | Wait a few minutes for the thermal/operating limit to reset. |
| 7 | Internal circuit fault | Disconnect all power sources for several seconds; if the problem recurs, have the motor/cables serviced and inspected. |
| 8 | Another command is already active | Remove the continuous or simultaneous command. |
| 9 | Automation blocked | Unlock it with the appropriate receiver command; do not confuse this with mechanical release. |
Control board LEDs and courtesy light
First distinguish Stand-by from a fault. When Stand-by is enabled, after one minute of inactivity the other LEDs go out and the BlueBUS LED flashes more slowly. Before assessing the LEDs, wake the control unit with a command only if the travel path is clear and safe; allow for possible gate movement. The following table applies when the control unit is awake.
| Indicator | Meaning |
|---|---|
| BlueBUS: green, once per second | Normal operation. Two quick green flashes = input change or command received. |
| BlueBUS: off / steadily lit | Check the power supply and fuses / fault requiring inspection of the control board. |
| BlueBUS: rapid and long red flashes | BlueBUS short circuit. Disconnect and check the wiring; after the fault is cleared, normal flashing may take about 10 seconds to resume. |
| STOP: lit / unlit | Normal after learning / safety input activated or faulty. |
| SbS, OPEN, CLOSE | An illuminated LED indicates that the corresponding command is active. |
| L1 + L2 flashing | Connected devices need to be detected. |
| L3 + L4 flashing | The gate positions need to be learned. |
| L1 or L8 flashing on its own while idle | L1 = upper limit, position ≥95%; L8 = lower limit, position ≤5%. Adjust the position and repeat the learning procedure; do not use the workshop encoder reset on an installed gate. |
| L1–L8 during movement | Current motor load; L1 low, L8 high. This is not the same as the relative force setting in the menu. |
| Courtesy light flashing once per second | Automatic force learning incomplete; if a fault flash is occurring at the same time, count the fault code. |
If the remote control does not respond and its LED does not light, check the battery. If the LED lights, check the receiver and pairing. If the control board is completely unresponsive, check the mains supply and fuses; replace a fuse only after eliminating the cause, using the same type and rating as indicated. If the gate moves briefly and then reverses, first check the gate’s resistance to movement, not just the force setting.
Maintenance reminder during normal operation
A beacon that stays lit for longer may indicate that servicing is due. This is not the same indication as the rapid groups of flashes used for faults. Applies when the FLASH output is configured accordingly; the maintenance indicator is an alternative mode of the same output.
| Service limit reached | Beacon in FLASH mode | Output in maintenance-indicator mode |
|---|---|---|
| Less than 80% | Normal flashing: on for 0.5 s / off for 0.5 s. | Lights for 2 seconds at the start of opening. |
| 81–100% | Lights for 2 seconds at the start of the operation, then flashes normally. | Flashes throughout the operation. |
| More than 100% | Lights for 2 seconds at the start and end of the operation; otherwise flashes normally. | Flashes continuously. |
Have the reminder addressed by a qualified maintenance professional; do not reset the counter just to stop the indication.
History of the last eight operations
- Hold STOP/SET for about 3 seconds, release when L1 lights, then select input LED L8.
- Hold STOP/SET and wait about 3 seconds. Lit LEDs indicate operations with faults: L1 is the most recent, L8 the eighth most recent. An unlit LED indicates an operation without a fault; the history is read-only.
- While holding STOP/SET, use ▲ / ▼ to select an operation. The LED flashes the corresponding code from the table.
- Release STOP/SET.
Reset, motor direction and service counter
Erasing the main control unit’s memory
A reset clears learned devices, positions and user settings. After resetting, select the number of motors again, perform the learning procedure and carry out tests; this is not a routine way to fix a mechanical fault.
- With the motor stopped, hold ▲ + ▼, until all L1–L8 LEDs light, about 3 seconds.
- Release the buttons. The LEDs flash rapidly for about 3 seconds and the control unit restarts.
- At the end, L1/L2 flash. Repeat device detection, L8 setting and position and force learning.
This reset does not change the set direction of rotation or the encoder position. The memory of the plug-in radio receiver is managed separately according to its instructions.
Changing the direction of rotation
- With the gate stopped, hold STOP/SET for about 3 seconds and release when L1 flashes.
- Briefly press ▲ + ▼ together and release.
- The courtesy light lit means the direction is reversed; unlit means the standard direction.
- Wait 10 seconds for the process to finish. Then repeat position learning and automatic force learning.
Restoring the encoder position
Resetting the encoder position is strictly a workshop procedure performed on a workbench. Never perform it with the motor installed on the gate. It sets the encoder to the L6 installation position and restores the control unit’s default settings at the same time. If needed, it must be performed by a service technician in accordance with the complete installation manual; it is not a substitute for learning the positions of an installed gate.
Reading and resetting the service counter
Level II, input LED L7: hold STOP/SET and wait about 3 seconds for the level to be displayed. Briefly press ▲ + ▼ to read the counter: each flash represents 10% of the set limit. For example, four flashes at a limit of 10,000 indicate 4,000–4,999 operations. Holding ▲ + ▼ for at least 5 seconds resets the counter; do this only after maintenance has been carried out. Then release STOP/SET.
Maintenance and safe use
Have the system professionally serviced no later than every 6 months or 4,000 operating cycles, whichever comes first. Shorten the interval appropriately if the system is used frequently. A counter reminder does not replace the time-based maintenance interval.
- Before carrying out work, disconnect the mains supply and battery and secure the gate against movement.
- Check the fixings, shafts, telescopic arms, cables, springs and guides for corrosion and wear. Replace damaged parts; spring adjustment must be carried out by a professional.
- After maintenance, restore the power supply and repeat the safety tests. Document the results.
- Users may clean the photocell lenses with a slightly damp cloth and remove debris from the gate’s travel path. Do not use the gate if it is faulty; contact the installer.
Only pass through when the gate is fully open and stationary. Keep children and remote controls away from moving parts. According to the installation instructions, check monthly that when closing against an object 50 mm high on the floor, the drive, upon contact with the lower edge, reverses direction. If it does not work correctly, stop automatic operation and arrange for servicing. The drive and batteries must not be disposed of with household waste; arrange for their removal and recycling.
Estimated service life
Add the relevant weight and force indices and other relevant factors; include the latter factors if the probability of their occurrence exceeds 10%. The weight in this table is an input for estimating wear, not a load capacity rating or permission to automate a gate of any weight. Installation and operating limits take precedence.
| Characteristics of the complete automation system | Index | Service life graph | |
|---|---|---|---|
| TN2010L | TN2010L + TN2020L | ||
| Gate weight up to 100 kg | 20% | 10% | The horizontal axis shows the sum of the indices in %, and the vertical axis shows the number of complete cycles. |
| Over 100–180 kg | 30% | 20% | |
| Over 180–230 kg | 40% | 30% | |
| Over 230 kg | 60% | 50% | |
| Operating force up to 160 N | 10% | 5% | |
| Over 160–240 N | 20% | 15% | |
| Over 240–290 N | 40% | 30% | |
| Over 290–350 N | — | 50% | |
| Temperature above 40 °C / below 0 °C or humidity above 80% | 10% | 10% | |
| Dust or sand | 15% | 15% | |
| Saline environment | 20% | 20% | |
| Photocell interruption | 10% | 10% | |
| STOP interruption | 20% | 20% | |
| Speed above level L4 | 15% | 15% | |
The graph of approximately 10,000–50,000 cycles is an indicative estimate assuming proper maintenance, not a service-life guarantee or a number of years. It does not simply count the number of openings and does not specify a service interval.
NICE TN2010L technical specifications
| Intended use | Main motor with integrated control unit and absolute encoder. |
|---|---|
| Power supply | 230 V AC −10/+15%, 50/60 Hz; the motor itself operates on low-voltage DC. |
| Max. starting torque | 350 Nm |
| Rated torque | 240 Nm |
| No-load speed | 1.7 rpm; six adjustable control levels. |
| Speed at rated torque | 1.2 rpm |
| Max. power consumption at startup | 240 W / 1 A from the mains. |
| Motor weight | 10 kg |
| Ingress protection and environment | IP44; install inside the garage. |
| Operating temperature | −20 to +50 °C |
| Overall dimensions | Height 512 mm, width 150 mm, depth according to drawing 160 mm; tabulated body depth 158 mm. |
| Auxiliary light | Built-in LED lighting. |
| Insulation class | I |
For the complete TN2010L + TN2020L assembly, the manual specifies a starting torque of 500 Nm, a rated torque of 330 Nm, and a power consumption of 350 W / 1.4 A from the mains and a weight of 17.2 kg for both motors. The torque of the assembly is not determined by simply adding the torques of the individual motors.
At rated load, the TN2010L is specified for 15 cycles/h and 22 minutes of continuous operation; the two-motor assembly is rated for 25 cycles/h and 14 minutes. At +50 °C, the corresponding values decrease to 6 cycles/h and 6 minutes for one TN2010L, or 4 cycles/h and 7 minutes for the pair. Actual operation is further limited by the load tables and the control system. The basic technical values apply at 20 °C ±5 °C.
To verify your selection, contact us with the gate type, height and width, balancing method, and expected number of cycles. For a replacement, include a photo of the rating plate and control board.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]















