NICE ROX 1000 - standalone drive for sliding gates (A)
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
for the question
€433.50 including VAT
| Weight |
|---|
| 13 kg |
Description of NICE ROX 1000 - standalone drive for sliding gates (A)
Replacement available!
NICE Rox ROX1000 has been replaced by a newer model NICE ROBO1000.
NICE ROX1000 is a standalone electromechanical drive for a sliding gate with a 230 V AC motor, integrated control unit ROA40R10 and radio receiver. The gate is stopped by mechanical limit switches actuated by cams on the rack. It is self-locking; in the event of a power failure, it can be released with a key.
Which sliding gate is the ROX1000 suitable for?
For a gate weighing up to 1,000 kg and 8 m long provided installation and operating conditions are met. For a typical selection, a maximum length of 5 mis recommended; for a longer gate, resistance, number of cycles and inertia must be assessed separately. Weight alone does not guarantee suitability.
The gate must move smoothly by hand, without catching or moving on its own. The force required to start and move it must not exceed 25% of the force available from the specific motor version. The drive does not replace repairs to the wheels, guide or misaligned rack.
| Gate length | Maximum cycles/hour | Maximum consecutive cycles |
|---|---|---|
| Up to 4 m | 40 | 20 |
| Over 4 m up to 6 m | 25 | 13 |
| Over 6 m up to 8 m | 20 | 10 |
The table applies to the 230 V ROX1000 under the conditions specified in the motor manual. The rated value is 20 cycles/hour, with a maximum continuous operating time of 4 minutes. One cycle consists of opening and closing; higher resistance or temperature may reduce the permitted operating duty.
ROA40R10 and differences from older control boards
The following procedures are for the ROA40R10 with a PROGRAM button, IBT4N connector and 10 DIP switches. The older ROA39 has different functions. Check the control board label under the cover before making adjustments.
The ROA40R10 features manual force and operating-time settings, automatic closing, optional soft start/slowdown and partial opening for pedestrian access. The speed of the main movement cannot be adjusted continuously. Commands can be supplied via a volt-free SbS contact; professional configuration is available using IBT4N with OVIEW.
What the standalone drive includes
One ROX1000 drive with integrated electronics and receiver, a base plate, anchors and fasteners as shown, release keys and limit-switch cams. The remote control, photocells, warning light and rack are selected separately or as part of a kit.
ROX1000 kits
| Kit | Equipment |
|---|---|
| Kit B | Drive and FLO2R-S remote control |
| Kit C | Includes EPM photocells |
| Kit D | Includes EPM photocells and ELAC warning light |
| Kit E | EPM photocells and 4 × LZ-1-1 rack sections |
| Kit F | EPM photocells, ELAC warning light and 4 × LZ-1-1 rack sections |
Each kit listed includes one motor and one FLO2R-S. Choose enough rack for the full gate travel, including any overhang; the four sections included in the kit may not be sufficient for every gate.
Installing the drive and rack
Disconnect the mains power before starting work. The mounting surface must be solid and level, and not in an area prone to flooding. The gate requires solid stops at both ends, a guide, and protection against derailment or lifting.
- Prepare the foundation, cable conduits and positioning in line with the rack. The motor and base plate must be parallel to the gate leaf.
- Secure the two anchors to the plate with a nut above and below. Leave the upper threaded section protruding 25–35 mm as shown.
- Set the plate level in concrete. Allow the concrete to cure fully before installing the motor.
- Fit the motor and washers, and initially tighten the nuts only lightly. Adjust the height using the adjustment screws.
- Release the motor. Fit the rack section by section while moving the gate by hand, keeping it aligned.
- Throughout the full travel, leave a gap between the rack and pinion 1–2 mm clearance. The gate's weight must not rest on the motor. Only after manually checking all sections, fully tighten the nuts and fit the caps.
Right- or left-hand installation
The drive is factory-set for right-hand installation as shown in the diagram. For left-hand installation, with the power disconnected, rotate the motor connector and limit switch connector by 180° as shown in the illustration. This does not involve swapping the PE protective conductor or the mains supply.
Setting the limit switches
- With the power disconnected and the motor released, open the gate manually so that it remains 2–3 cm from the fixed mechanical stop.
- Slide the opening limit-switch bracket along the rack until the limit switch engages and you hear a click.
- From this point, move it at least another 2 cm in the same direction and secure it with screws.
- Repeat the same procedure on the closing side.
- After testing the motor, check that the gate stops safely, taking its inertia into account. The limit switch does not replace the fixed stop.
Manual opening during a power failure
- Stop the gate, switch off the power and hold it to prevent it from moving on its own.
- Slide the lock cover aside, insert the key and turn it as shown in the illustration. Pull out the release handle.
- Move the gate by hand. Make sure the entire passage is clear and the gate leaf is stable.
- To re-engage the drive, push in the handle, lock it, remove the key and close the cover. Check that the drive is engaged before issuing an automatic command.
Types of electrical cables
| Circuit | Cable type | Maximum length |
|---|---|---|
| A – power supply | 3 × 1.5 mm² | 30 m |
| B – warning light | 2 × 1.5 mm² | 10 m |
| C – antenna | RG58 coaxial cable | 10 m; less than 5 m recommended |
| D – photocells TX / RX | 2 × 0.25 / 4 × 0.25 mm² | 30 m |
| E/F – key switch | 2 cables, 2 × 0.5 mm² each, or one 4 × 0.5 mm² cable | 20 m |
For mains cables longer than 30 m, use a larger cross-section, such as 3 × 2.5 mm², and provide protective earthing at the automation system as instructed in the manual. The drive is Class I and requires PE. Separate power and signal cables, and secure the cables to prevent them from being pulled out or allowing water ingress.
Lowercase letters indicate the devices: a, motor; b, photocells; c, their posts; d, key switch or keypad; e, warning light; and f, rack.
ROA40R10 wiring and polarity
| 8 / 9 – accessories | 8 = − (0 V), 9 = +24 V DC, tolerance ±10%, total current draw no more than 100 mA. |
|---|---|
| 9 / 10 – STOP | Learnable input: NO, NC or 8.2 kΩ; see below for details. |
| 9 / 11 – PHOTO | Voltage-free NC photocell contact. If interrupted during closing, it reverses the movement. |
| 8 / 12 – Phototest | 8 = negative, 12 = switched positive for TX, up to 100 mA. RX remains connected to 8−/9+. |
| 9 / 13 – SbS | Voltage-free NO step-by-step command. Do not apply external voltage to the input. |
| 4 / 5 – FLASH | 230 V AC, warning light with built-in flashing function, up to 60 W; for example, NICE ELAC. AC has no plus/minus polarity. ELDC must not be connected to this output. |
| 1 / 2 – antenna | Coaxial input for the integrated receiver. Connect the centre conductor and shield as shown in the diagram; this is not a +/− power supply. |
Leave approximately 20–30 cm of spare wire beneath the cover and secure the wires properly. After testing is complete, fit the cover and tighten the screw. The motor and capacitor outputs are not accessory power supplies.
EPM photocells and Phototest
ROX uses conventional relay photocells, for example, NICE EPM. Two-wire EPMB photocells cannot be connected directly to it as BlueBUS devices. For EPM, the power terminals on both TX and RX are 1 positive / 2 negative. Connect the RX output contact 4 COM → 9 and 5 NC → 11 on the control board.
Without the Phototest function
Power both TX and RX from 9+ and 8−. Connect the receiver's NC contact between 9 and 11.
With the Phototest function
RX remains connected to 9+ / 8−, TX is powered from the switched output 12+ / 8−. Before movement, the control unit checks the photocells; if the test fails, the gate will not start moving. For EPM units powered by this DC voltage, leave the SYNC jumper in its original position; EPM synchronisation mode is intended for AC power. After making the change, perform device recognition.
During the test, interrupt the beam at the transmitter, at the receiver, and midway between them. Check the response during closing and, when DIP6 is enabled, during opening as well.
STOP input and adding devices
During learning, STOP on terminals 9/10 detects NO, NC, or an 8.2 kΩ resistor. Any change from the learned state triggers a stop and a brief reversal. After adding or removing a STOP device or changing PHOTO, repeat the learning procedure.
- Multiple NO contacts are wired in parallel.
- Multiple NC contacts are wired in series.
- Resistive safety edges must be wired according to their instructions, with a total end-of-line resistance of 8.2 kΩ.
- When combining NO and NC, the parallel NC branch is routed through an 8.2 kΩ resistor. Design this type of combination according to the safety function.
For a Category III safety function, the manufacturer requires this wiring to use devices with a constant resistance of 8.2 kΩ. A simple jumper or contact does not replace an assessment of the complete assembly. Phototest provides enhanced photocell monitoring when wired accordingly; safety must be retested after every intervention.
Initial startup and device recognition
- With the power off, check the mains/PE connection, right- or left-hand installation, limit-switch rails, STOP, and photocells.
- Move the gate manually to approximately the midpoint of its travel and engage the drive. Clear the passage and switch on the power.
- In normal standby, the OK LED should flash green once per second. PHOTO and STOP should be lit; FCA/FCC are lit when the limit switches are not engaged, and the corresponding LED goes out when they are activated.
- Press and hold PROGRAM. After about 3 seconds, OK starts flashing rapidly; keep holding the button.
- Wait until STOP is lit and OK is continuously lit green. Release PROGRAM within 10 seconds. Three green flashes confirm success; five red flashes indicate that learning failed.
- Use a brief command to check the direction of travel and operation of the limit switches. If an error occurs, stop the movement and disconnect the power before carrying out repairs.
- Set TL/TP/F and the required functions. Repeat learning after changing DIP1/2 or the STOP/PHOTO wiring, then carry out the full set of tests.
Device recognition detects the safety inputs. Set the travel path using the limit-switch rails and the TL operating time.
TL, TP and F settings and DIP switches
| TL – operating time | Set it to cover the full movement, with a reserve of approximately 2–3 seconds. When slowdown is enabled, set the time so that slowdown begins about 50–70 cm before the limit switch. |
|---|---|
| TP – pause | Sets the waiting time before automatic closing in automatic mode. |
| F – force | Sets the motor power. Make adjustments while measuring forces and testing the safety devices, not as a remedy for a gate that is sticking. |
The factory default is semi-automatic mode: DIP1 ON, DIP2–10 OFF. Change the switches with the power disconnected.
| DIP1 | DIP2 | Mode |
|---|---|---|
| OFF | OFF | Manual – movement only while the command is held |
| ON | OFF | Semi-automatic |
| OFF | ON | Automatic with TP pause |
| ON | ON | Automatic + always close; after power is restored, closes after 5 seconds |
| DIP | Function when ON |
|---|---|
| 3 | Condominium mode: commands issued while opening do not interrupt the movement; this does not apply to manual operation. |
| 4 | Pre-flashing for 5 seconds, or 2 seconds in manual mode. |
| 5 | Closing after the photocell is cleared: in automatic mode, reduces the pause to 5 seconds; in semi-automatic mode, activation during closing may trigger closing after TP. |
| 6 | Photocells also act during opening. |
| 7 | Soft start. |
| 8 | Slowdown at the end of travel; also reduces the available torque, so TL must be set correctly. |
| DIP9 | DIP10 | Braking |
|---|---|---|
| OFF | OFF | Off |
| OFF | ON | Low |
| ON | OFF | Medium |
| ON | ON | High |
When DIP8 is enabled, the slowdown speed drops to 30% of the nominal value and the motor torque drops by approximately 70%. If the gate requires high torque, it may stop during this phase; check that it reliably reaches the limit switch.
After changing DIP1/2, perform device learning. For work involving the TLM jumper and advanced service settings, follow the installation manual.
Built-in receiver and remote control pairing
The 433.92 MHz receiver supports FLO, FLOR, O-CODE and HCS SMILO. The first remote control programmed determines the code family; all others must be compatible with it. Different families cannot be combined just because they use the same frequency.
Compatible models include FLO2R-S, FLO4R-S, FLO2, FLO4 and SMILO SM2. FLO uses a fixed code, while FLOR and SMILO use rolling codes. When replacing an old RO500, first check which remote-control family is in use.
Mode 1 – storing the entire remote control
- On the board, press and hold the RADIO button for about 4 seconds, until the radio LED lights up, then release it.
- Within 10 seconds, press and hold any button on the remote control being programmed for approximately 3 seconds. Three LED flashes confirm that it has been stored.
- Another remote control from the same family can be stored during the next 10-second interval; otherwise, wait for the process to finish.
On the ROA40R10, the buttons are assigned in Mode 1 as follows: 1 step-by-step, 2 partial opening, 3 open, 4 close. One- and two-button remote controls have only the corresponding first commands.
Mode 2 – single button
Press RADIO briefly to select a command: 1× step-by-step, 2× partial opening, 3× open, 4× close, 5× STOP. The number of flashes must match the selection. Within 10 seconds, hold the desired remote-control button for approximately 3 seconds; three flashes confirm that it has been stored.
One quick flash means the code is already stored, six flashes indicate an incompatible family, and eight indicate that the memory is full. The receiver can store up to 100 remote controls in Mode 1. For further procedures, see the NICE remote control pairing instructions.
Deleting radio remote controls
With the radio memory unlocked, press and hold RADIO: the LED lights up, goes out, and then flashes three times. Release it during the third flash. Five flashes confirm that all remote controls have been deleted. This does not reset the drive settings. If the memory is locked, follow the unlocking procedure in the installation manual.
Accessories and replacing an older ROBO
When replacing a NICE ROBO RO500 existing accessories can often be retained, but check the voltage, current draw, contact type, and coding.
| Photocells | EPM or a suitable NC relay pair. When using a 24 V DC supply, observe the polarity and current limit. |
|---|---|
| Warning light | ELAC to FLASH 230 V AC. An old 12/24 V warning light cannot be connected directly to this output. |
| Key switch / external module | Voltage-free NO contact on terminals 9/13. The external module's power supply must meet its requirements and the 100 mA limit. |
| Rack | Module 4, correct length, and 1–2 mm clearance. Also check the existing rack for wear and verify its height. |
| Service | IBT4N with OVIEW. Disconnect the power supply before connecting. |
For smart system integration requirements, verify the specific module and the commands required. The ROX receiver has no connector for the plug-in OXIBD; functions from newer BlueBUS drives cannot automatically be transferred to it.
ROA40R10 diagnostics
| OK LED | Meaning and action |
|---|---|
| Off | Check the power supply and fuses; remove any short circuit before replacing a fuse. |
| Green, once per second | Normal standby. Two quick green flashes indicate an input change. |
| 1 red flash | Learning failed or DIP1/2 changed: check the inputs and repeat the learning procedure. |
| 2 red flashes | PHOTO is preventing movement; remove the obstruction and check the photocells. |
| 4 red flashes | STOP activated; check the safety device. |
| 5 red flashes | Internal parameter error. Wait at least 30 seconds; if the fault persists, call for service and restore the settings. |
| 7 red flashes | Internal circuit error or mode change. Disconnect the power supply, check the condition and settings; if the fault recurs, call for service. |
| 8 red flashes | A command that prevents any other movement is active; check the remote control or contact. |
For PHOTO and STOP, an illuminated LED indicates that the input is ready; an unlit LED indicates activation or a fault. SbS is lit while a command is active. FCA/FCC go out when the corresponding limit switch is activated. A steady red or green OK LED outside the learning procedure requires a fault check.
Restoring the settings
Reset only after identifying the cause of the fault. With the motor stopped, switch off the power supply, press and hold PROGRAM, then switch the power back on. After OK lights up and goes out, there are three flashes; release PROGRAM during the third flash. Five flashes confirm that the settings have been restored.
This procedure does not delete the remote controls, but it unlocks the radio memory. Before operating the system again, reset the functions, teach in the devices, and carry out tests. Use the separate RADIO button to delete remote controls.
Testing, use, and maintenance
Before handing over the system, repeatedly check the full travel, limit and fixed stops, manual release, photocells/Phototest, and STOP, and measure the impact forces. Check that the gate does not move dangerously after a power failure or a change of mode.
Carry out maintenance at least every 6 months or 20,000 manoeuvres, whichever comes first. Check the anchors, rack and its clearance, wheels, guide, corrosion, cables, manual release, and all safety devices. Disconnect the mains power before working on the system.
Do not enter the passage while the gate is moving, and do not allow children to play with the gate or remote controls. If the gate leaf has a pedestrian gate, opening it must prevent the motor from starting. If you hear unusual noise or a fault occurs, stop the automation, release the gate safely, and contact a service technician. Do not bridge safety inputs. If the gate is the only access point, arrange access to the manual release during installation.
ROX1000 technical specifications
| Motor / power supply | 230 V AC, 50/60 Hz |
|---|---|
| Power consumption | 350 W |
| Rated / maximum torque | 9 / 24 Nm |
| Force | Rated 250 N, maximum 670 N |
| Speed | 8.5 m/min rated, 11 m/min unloaded |
| Max. weight / length | 1,000 kg / 8 m under the conditions stated above |
| Rated operation | 20 cycles/h; maximum 4 minutes continuous operation |
| Pinion | Z15, module 4, tooth pitch 12.5 mm, diameter 60 mm |
| Operating temperature | −20 to +55 °C |
| Ingress protection / electrical class | IP44 / I, PE protective conductor |
| Dimensions / weight | 330 × 210 × 303 mm / 11 kg |
| Control unit | NICE ROA40R10 with an integrated 433.92 MHz receiver |
To verify your selection, send us the length, weight, photos of the guide rail, and the expected number of cycles. Contact us.
Installation manual PDF
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]













