Fast and quiet NICE Spykit 650 HS BD drive


Product availability: In stock

We normally dispatch goods within 24 hours.


Fast and quiet NICE Spykit 650 HS BD drive Fast and quiet NICE Spykit 650 HS BD drive
NICE-SPY650-HS-KIT
in stock
€298.84 excluding VAT
€367.57 including VAT

 pcs
Weight
7,00 kg

Description of Fast and quiet NICE Spykit 650 HS BD drive

NICE SPYKIT 650 HS BD is a fast kit with a SPY650HS, 24 V DC, a separate SPYBOX BHS, OXIBD receiver and one ON3EBD. The complete system is powered from the mains 230 V AC. The motor is non-backdrivable; pull the cord to release it for manual operation.

The kit includes 1× one-piece SPYRAIL321 rail, 3.2 m long, with mounting accessories. The rail guides and powers the moving motor.

Quick navigation
AccessoriesFeatures and comparison
Selection and limitsInstallation
Terminals and polarityPhotocells
Initial start-upSettings
Remote controlsReset
DiagnosticsManual release
MaintenanceSpecifications
PDF manual

Control unit and compatible accessories

Photocells, a warning light and a safety edge are not automatically included. Obstacle detection does not replace a safety assessment of the entire gate or force measurements during commissioning.

WhatWhyType
Control unitA separate wall-mounted control unit; it operates the motor and safety devices.
Remote controlTwo-way control and feedback confirming command reception / gate status.
RailGuides and supplies power to the moving motor.
PhotocellsObstacle detection in the protected area.
Additional photocellsAdjustable or specialised solutions depending on the gate design.
  • F210B, FT210B, EPMOW; choose according to their own wiring method and current availability.
SignallingWarning during operation and optional lighting.
Up-and-over doorAdaptation for the traction arm's travel path.
  • SPA5 for compatible up-and-over doors; with spring-operated doors, check whether installation without SPA5 is possible.
Service configurationAdvanced configuration and diagnostics via BusT4.
Backup powerOperation during a power failure.
  • PS324 depending on the control unit version; check the availability of a suitable backup power supply with us. Use a backup power supply designed for this control unit.

SPYKIT650HSBD kit contents

Compare the drive type, speed, controls and specific gate limits. Greater force or speed alone does not guarantee suitability. Safety accessories and backup power are selected separately.

Fast SPY kit
NICE SPYKIT 650 HS BD
NICE SPYKIT 650 HS BD
650 N; speed up to 0.24 m/s. SPYBOX BHS, OXIBD and ON3EBD; 1× SPYRAIL321, one-piece 3.2 m rail.

Which garage door is the SPY650HS suitable for?

The kit is designed for sectional doors up to 10.5 m² or up-and-over doors up to 11.5 m². The approximate dimensions below are width × height; they depend on the type and length of the rail. Also check the balance, resistance and installation clearance. Area alone is not enough.

Door type3.2 m rail4 m rail
Sectional4.2 × 2.5 m3.2 × 3.3 m
Non-protruding up-and-over door with SPA54.0 × 2.3 m3.0 × 3.1 m
Protruding up-and-over door with SPA5 / spring-operated without SPA54.0 × 2.8 m3.3 × 3.5 m

The motor has a maximum force of 650 N and a rated force of 200 N. Newtons are not the door's weight in kilograms. For residential use, the door must move easily by hand, with resistance no greater than 150 N; do not compensate for faulty springs or binding by increasing the motor force.

What does opening in approximately 8.5 seconds mean?

The figure approximately 8.5 seconds is based on a typical door with a height of 2 m and does not include acceleration or deceleration. This is not a guaranteed time for the complete movement of any door. The maximum speed is 0.24 m/s; the actual time depends on the settings, travel and load.

Operating load

LimitValue
Cycles per hourUp to 30
Cycles per dayUp to 300
Continuous cyclesUp to 12

One cycle is a complete opening and closing. These are maximum limits for a suitable door, not a requirement for the operator to handle the same number of cycles under any resistance or temperature conditions. A longer rail does not increase the permitted door area. If you need help confirming your selection, send us the door type, dimensions and expected usage.

Installing the SPYRAIL rail, motor and SPYBOX BHS

Disconnect the mains power and backup power before installation. Check the springs, balance and manual operation of the door. The SPY650HS carriage runs directly along the toothed rail; it does not use a belt or chain. The motor receives 24 V DC through the rail and insulated inner profile.

The rail must be electrically isolated from the door and nearby conductive structures. Use the supplied insulating components. Contact between the rail and a metal door, or damaged insulation, can cause a short circuit; the same installation arrangement as for the SR32B is not suitable.

  1. Release the motor using the cord and check that the toothed wheel moves freely. For a two-piece rail, join the two profiles, secure the connector and insert the strip into the insulating profile without deforming it.
  2. Insert the motor in the correct orientation. When pulling out the two transport strips, both contact elements must be secured as shown in the installation diagram. Do not force the motor in if the contacts are extended incorrectly.
  3. Fit both adjustable limit stops and the power supply end piece. Its position must match the MOT wiring and direction of travel.
  4. Align the rail with the centreline of the door, level it with the ceiling and use secure fixings with the supplied insulation. Shorten the ceiling brackets so they are flush with the rail and do not obstruct the carriage.
  5. Attach the arm to a suitably reinforced part of the door. Set the closing and opening stops, and securely tighten their screws.
  6. Mount the SPYBOX BHS on the wall in a position suitable for safe operation and servicing. The release cord must be accessible at a height below 1.8 m. Position controls away from moving parts, generally at least 1.5 m above the floor.

SPY installation clearance: A, B and distance C from the highest point of the door

In the orientation shown, maintain

  • A = 40–400 mm
  • B = 0–400 mm
  • C = 65–300 mm.

C is the clearance between the rail and the highest point of the door during movement.

Wiring

ConnectionCross-section / maximum length
MOT – rail power supply2 × 1 mm²; 5 m; supplied cable.
BlueBUS2 × 0.75 mm²; 20 m; devices connected in parallel.
INP1 / INP2 / STOP2 × 0.5 mm²; 20 m.
FLASH2 × 0.5 mm²; 20 m.
AntennaRG58; 10 m; separate coaxial cable.
Mains supply3 × 1 mm²; 230 V AC 50/60 Hz; protective conductor and suitable disconnection.

Keep low-voltage wiring separate from the mains and secure it against tension, door movement and crushing. Do not connect the 230 V supply to accessory inputs.

SPYBOX BHS: terminals and polarity

These terminals are for the SPYBOX BHS with BlueBUS. The basic SPYBOX with relay PHOTO uses different wiring. Before working, check the label on the unit actually installed.

SPYBOX B/HS wiring: rail, BlueBUS, commands, STOP, flashing light and antenna

TerminalsFunction / connection
MOT − / +24 V DC for the rail power supply unit. Observe the marked − / + and orient the power supply unit as shown. Change the direction with the power disconnected.
BlueBUSTwo-wire communication and power supply for compatible devices; without polarity +/−.
Open / INP2Normally, a voltage-free NO contact between Open and its common terminal +. The function is changed by parameter INP2.
SbS / INP1Voltage-free NO contact between SbS and its common terminal +; step command.
STOPSafety input to GND; NO, NC, or 8.2 kΩ; the type is learned during device recognition. The contact itself has no polarity.
FLASH / OUT1Factory beacon mode 12 V DC / 21 W; programmable 24 V DC / 25 W. Select the mode according to the actual load.
AERIALDedicated coaxial antenna input; connect the center conductor and shield as shown in the detail. Do not use it for power.
L / N / PE230 V AC mains and protective earth; keep separate from the motor and accessories.

SPYBOX BHS terminal block orientation and marked common terminals

Power supply for external controls: positive and negative

With the same orientation as shown in the image, the right-hand terminal of the STOP pair = GND, negative (−) and the left-hand terminal of the SbS pair = power supply, positive (+). The “24 Vdc” marking at the terminal does not replace checking the permitted operating range of the connected device: the auxiliary supply provides 30 V DC, with a tolerance of −20% / +5%, i.e. approximately 24–31.5 V DC, and a maximum of 100 mA total. Use only a device suitable for this entire range.

SPYBOX auxiliary power supply: right-hand STOP negative, left-hand SbS positive

Control module button or relay

The command is generated by a voltage-free NO contact between INP1 (SbS) and the common terminal + of this pair. If the module requires power, connect it separately to a verified positive and negative. Do not apply the module's output voltage to the command input.

STOP safety edge

A change in the learned STOP state immediately stops movement and briefly reverses direction. NO contacts can be connected in parallel; NC contacts must be connected in series. For a monitored resistive safety edge 8.2 kΩ activate the STOP 8K2 test and then learn the devices. Connect combinations of different types according to their wiring diagrams; a standard switch is not equivalent to a monitored safety edge.

Gate with built-in pass-through wicket door

The moving motor's circuit board has a separate pair of terminals 1–2 for the safety microswitch NC. The motor must be inhibited when the door is open. With the power disconnected, remove the jumper and connect a contact rated for at least 10 A; cable length no more than 3 m, minimum cross-section 1 mm². Protect it against pinching. The contact has no polarity and is not a power output.

Safety contact for the built-in wicket door, connected to terminals 1–2 of the SPY motor

BlueBUS photocells

EPSB, EPMB or EPLB connect from both TX and RX in parallel to the BlueBUS pair. This is a polarity-free connection. Relay-type NC photocells must not be connected to this bus as a substitute for a two-wire device.

  1. With the power off, set the same jumpers on the TX and RX units of each pair. Each additional pair must have a different address.
  2. Align the transmitter and receiver, then complete the wiring. Choose the function according to the area to be protected.
  3. After adding, removing, or changing an address, repeat device recognition and test each pair.

AddressFunctionTX / RX jumpers
PHOTOWhen closing, reverses to open; h = 50 cm.TX and RX jumpers for the PHOTO address
PHOTO IIWhen closing, reverses to open; h = 100 cm.TX and RX jumpers for the PHOTO II address
PHOTO 1When closing, briefly stops and reverses; h = 50 cm.TX and RX jumpers for the PHOTO 1 address
PHOTO 1 IIWhen closing, briefly stops and reverses; h = 100 cm.TX and RX jumpers for the PHOTO 1 II address
PHOTO 2Stops movement while opening.TX and RX jumpers for the PHOTO 2 address
PHOTO 2 IIStops movement while opening.TX and RX jumpers for the PHOTO 2 II address
PHOTO 3While opening and closing, briefly stops and reverses to open.TX and RX jumpers for the PHOTO 3 address
FA1Open command; requires suitable photocells and adjustment of jumper A.TX and RX jumpers for address FA1
FA2Second open command; requires suitable photocells and adjustment of jumper A.TX and RX jumpers for address FA2

Enlarge all jumpers. For FA1/FA2, do not modify the device without checking its own instructions; these provide a command function, not standard protection during closing.

ELDC or WLT beacon and antenna

For ELDC a standard FLASH 12 V DC; the permitted power for this mode is 21 W. ELDC has a FLASH power input for 12–36 V DC. For WLT select a suitable 24 V mode and check its setting as well. The voltage changes level II/L4; do not change it without checking the connected load.

On the beacon, distinguish FLASH from AERIAL. The displayed ELDC detail does not show the +/− polarity for FLASH; do not infer it from the auxiliary STOP/SbS connector. Connect the antenna with a separate coaxial cable, with the centre conductor and shield as shown in the diagram.

ELDC beacon: FLASH power supply and separate AERIAL antenna

Initial start-up and setup of SPYBOX BHS

First set and secure the mechanical stops, connect the safety devices, and secure the motor with the gate approximately halfway along its travel. The entire gate area must be clear during setup. This control unit uses the PROG switch, the OPEN, STOP/SET and CLOSE buttons, and LEDs L1–L8.

1. BlueBUS and STOP device recognition

  1. Move PROG to the left to I, i.e. to programming mode. Perform recognition even if no accessories have been added.
  2. Press and hold OPEN + STOP/SET for about 3 s; release when L1 + L2 flash rapidly.
  3. Wait for recognition to complete. Relays may switch during the process. Then move PROG to the right to 0.

2. Gate position recognition

  1. Check both stops and make sure the motor is secured. To perform the procedure, move PROG to the left to I.
  2. Press and hold STOP/SET + CLOSE for about 3 s; release when L3 + L4 flash rapidly.
  3. The drive must perform closing → opening → closing. Wait for the entire sequence to finish.
  4. Move PROG to the right to 0, then test normal operation.

If the first movement is towards opening, stop the setup immediately. Disconnect the mains and backup power, check the orientation of the power supply unit, and swap the MOT motor connections according to the installation diagram. Start the setup again. Do not swap the BlueBUS or STOP wires to correct the motor direction.

Testing before normal operation

  • Repeat opening and closing; check the stops, deceleration, brackets, and smooth operation.
  • Test STOP, each photocell at TX, RX and midway through the beam, and the pedestrian-door safety contact, if fitted.
  • Check manual release, re-engagement, and that the remote control operates the correct receiver.
  • Measure impact forces and set the minimum required for safe movement. Do not compensate for binding by increasing the force.
  • Provide the user with the instructions and maintenance schedule. Only pass through when the gate is fully open and stationary.

SPYBOX BHS programming

PROG left = I, programming mode. PROG right = 0, normal operation. In programming mode, the OPEN / CLOSE buttons select options; movement commands are disabled. If the gate does not respond after adjustment, first check the PROG switch position.

Level I – ON / OFF functions

  1. Move PROG to the left. Press and hold STOP/SET 3 s, until L1 starts flashing, then release.
  2. Use OPEN / CLOSE to select the function LED. Briefly press STOP/SET to change the status: lit = ON, unlit = OFF.
  3. Do not exceed 10 s. Wait 10 s without pressing any buttons, or move PROG to the right to exit.

LED – functionMeaning / status
L1 – Automatic closingON: closes after a pause set in II/L1 once fully open. OFF: waits for a command.
L2 – Close after photocellON: initiates closing when passage through the photocell is complete. Requires photocells to be installed and tested.
L3 – Always closeON: initiates closing after power is restored, with a 3 s pre-flash.
L4 – StandbyON: after 1 minute of inactivity, reduces power to the output and BlueBUS transmitters. Check dependent accessories.
L5 – 8K2 STOP testON: tests the 8.2 kΩ resistive safety edge before a manoeuvre. Devices must be learned after activation; unsuitable for a standalone NC/NO contact.
L6 – OPEN / CLOSE lockoutON: disables the movement buttons on the cover when PROG is in the normal 0 position.
L7 – Disable learning for the internal radioON: prevents new remote controls from being stored in the built-in radio receiver. Does not affect the memory of a separate OXIBD.
L8 – Disable the internal radioON: the internal receiver does not respond to stored remote controls. OXIBD is configured separately.

In the normal PROG 0 position, L1–L8 are off even when functions are active. Therefore, the LEDs being off during normal operation does not mean that every function is disabled.

Level II – parameter values

  1. Move PROG to the left and press and hold STOP/SET 3 s until L1 flashes; release.
  2. Use OPEN / CLOSE to select the input LED for the desired parameter.
  3. Press and hold STOP/SET. After 3 s the value LED will light up. Keep holding STOP/SET and use OPEN / CLOSE to select the new value.
  4. Release STOP/SET. Wait 10 s without pressing any buttons, or return PROG to the right.

Values shown in bold are factory defaults; the actual board settings take precedence. For L8, the radio command is triggered; it is not a persistent default. Speed and force percentages have different meanings.

Input LED – name and descriptionSetting LED – value
L1 – Pause
Used for automatic closing when I/L1 is ON.
L1 – 10 s
L2 – 20 s
L3 – 40 s
L4 – 60 s
L5 – 80 s
L6 – 120 s
L7 – 160 s
L8 – 200 s
L2 – Operating mode
Step-by-step command sequence. L7/L8 are not used.
L1 – open – stop – close – stop
L2 – open – stop – close – stop
L3 – open – close – open – close
L4 – common input
L5 – hold-to-run operation
L6 – industrial mode
L7 – not used
L8 – not used
L3 – Motor speed
Percentages of the maximum. V1 = 30%, V2 = 50%, V3 = 75%, V4 = 100%.
L1 – 30%
L2 – 50%
L3 – 75%
L4 – 100%
L5 – opening 75%, closing 30%
L6 – opening 75%, closing 50%
L7 – opening 100%, closing 50%
L8 – opening 100%, closing 75%
L4 – FLASH / OUT1
The mode must match the load voltage and purpose.
L1 – gate open indicator
L2 – active when the gate is closed
L3 – active when the gate is open
L4 – 12 V DC / 21 W flashing light
L5 – 24 V DC / 25 W flashing light
L6 – electric lock
L7 – magnetic latch
L8 – radio channel 2
L5 – Motor force
Opening / closing; regulation percentages, not impact force in N.
L1 – 25 / 25%
L2 – 50 / 50%
L3 – 75 / 75%
L4 – 100 / 100%
L5 – 75 / 25%
L6 – 75 / 50%
L7 – 100 / 50%
L8 – 100 / 75%
L6 – Obstacle sensitivity
Opening / closing. A higher number means greater sensitivity and a lower permitted force.
L1 – off
L2 – 60 / 60%
L3 – 60 / 70%
L4 – 60 / 80%
L5 – 60 / 90%
L6 – 70 / 70%
L7 – 70 / 80%
L8 – 70 / 90%
L7 – INP2
Contact type and function of the Open input; common + terminal.
L1 – step-by-step, NO
L2 – open, NO
L3 – close, NO
L4 – partial opening 1, NO
L5 – STOP, NC
L6 – PHOTO during closing, NC
L7 – PHOTO1 during both opening and closing, NC
L8 – PHOTO2 during opening, NC
L8 – Built-in radio command
Applies to the built-in FLOR receiver, not the supplied OXIBD.
L1 – store the entire transmitter in Mode 1
L2 – Mode 2 – step-by-step
L3 – Mode 2 – partial opening
L4 – Mode 2 – open
L5 – Mode 2 – close
L6 – Mode 2 – STOP
L7 – Mode 2 – lighting
L8 – delete one code

After changing the force, sensitivity or speed, repeat the safety test and force measurement. When using a different output mode, disconnect any load that is no longer compatible with its function.

Pair the ON3EBD with the supplied OXIBD

This kit includes a plug-in OXIBD two-way receiver and a three-channel ON3EBD transmitter. Pair the ON3EBD in two-way mode using button A on the OXIBD, not the board's L8 menu. The SPYBOX BHS also has its own one-way FLOR receiver. When using the OXIBD, the built-in radio can be disabled via I/L8 ON.

OXIBD: Mode 1 – entire transmitter

  1. On the OXIBD, press and hold button A until the green LED lights up B and release it.
  2. Within 10 s briefly press and release one of the ON3EBD control buttons. Do not use the i button to request the status.
  3. Successful storage is confirmed by 3 green flashes of B. Another transmitter can be added within the next 15 s.

ON3EBD buttonCommand in mode 1
1Step-by-step
2Partial opening
3Open
iStatus query with a correctly configured two-way system; not a fourth movement channel.

OXIBD: mode 2 – one button

Press A on the OXIBD n times, according to the command number; LED B confirms the count. Within 10 seconds, briefly press the selected ON3EBD button; three green flashes confirm success. Start a new procedure for the next command.

NumberSPYBOX BHS command
1Step-by-step
2Partial opening 1
3Open
4Close
5STOP
6Step-by-step shared input
7High-priority step-by-step
8Unlock and open
9Unlock and close
10Open and disable automation
11Close and disable automation
12Disable automation
13Enable automation
14Lighting – timer
15Lighting ON/OFF

Status feedback requires the correct series and control address configuration in the OXIBD. For the configuration procedure and details, see the OXIBD receiver manual and its installation PDF. Pairing a transmitter is a separate operation from identifying the control unit.

Clearing the OXIBD memory

Clearing the memory will erase the stored remote controls. Keep holding A through B lighting up and then going out. When the next series of flashes begins, release it exactly at the 3rd flash to erase all transmitters, or at the 5th flash to erase the receiver’s entire memory. At the 7th flash, only the BusT4 series/address is erased; do not confuse these operations.

After clearing two-way pairing, you must also remove the stored data from the ON3EBD; use the ON3EBD reset procedure, then pair the remote control again. Resetting the SPYBOX board or using its option 6 will not erase a separate OXIBD.

Built-in one-way FLOR receiver

If you are using a compatible one-way transmitter with the internal radio, enter II/L8 and select L1 for the entire transmitter or L2–L7 for a specific command. After selecting the value, release STOP/SET and within 10 seconds send the required button signal. Three slow flashes confirm storage; one means the transmitter is already stored, eight indicate full memory, and two quick flashes indicate learning is disabled. L8 deletes the single code that was transmitted.

Clearing the SPYBOX BHS memory

Before clearing, decide what you want to keep. Move PROG to the left to I and hold OPEN + CLOSE until the corresponding LED lights up. Releasing the buttons starts the selected operation; then move PROG back to the right.

Hold time / LEDEffect
3 s / L1Erases settings and learned configuration; preserves the internal radio codes.
6 s / L2Erases only the internal radio codes.
10 s / L3Erases settings and internal radio codes.

The separate OXIBD remains unchanged; its erasure is a separate operation. After clearing the configuration, repeat the device, position learning and perform a full gate test.

Troubleshooting

Count one series of short flashes. The warning light, internal light, OK/BB and any SPYLIGHT repeat the series after a 1-second pause.

FlashesCause / next step
1BlueBUS
Check the cables and connected devices; after making a change, repeat learning.
2Photocell
Remove the obstruction, check alignment and addresses / wiring.
3Force limitation
Check manual movement, springs and binding. Increase the force only after resolving the mechanical cause and performing a new test.
4STOP
Check the safety edge, contacts and the settings for the 8K2 test.
5Parameter memory
Disconnect and restore the power supply. If the error persists, check the configuration; a complete reset requires the system to be taught again.
6Unused
No associated fault is listed for this model.
7Internal electrical circuit
Disconnect all power supplies for 20–30 s. If it happens again, order service.
8Continuous command
Check for a button, relay, or control unit that is continuously activated at the command input.
9Automation locked
Use the Unlock automation command; make sure the area is clear before movement.
10No motor current detected during learning
Check MOT, the power-supply end piece, the track contact, and the trolley contacts.

SymptomCheck
Gate does not respond; OK flashes rapidly twicePROG was left turned to the left; turn it back to the right to 0.
OK/BB offCheck the mains supply and fuse. Find and fix the cause before replacing the fuse; use the same type.
OK/BB lit for more than 20 sDisconnect the power supply for 20–30 s; if it happens again, contact service.
L1 + L2 flashingDevices need to be taught.
L3 + L4 flashingPositions need to be taught.
Internal light flashes rapidly for 10 sMOT short circuit or excessive current draw. Check the track's electrical insulation and balance.
Remote control lights up, but gate does not respondCheck that the OXIBD receiver is correct, and check pairing and the lock.

Backup power supply

SPYBOX BHS supports backup power using PS324. Connect it only after installation and programming are complete, using the designated connector; disconnect both the mains supply and battery before servicing. Availability and correct type confirm when ordering. Solemyo solar power is not automatically compatible with the high-speed BHS version of the standard SPYBOX B.

Manual release and re-engagement

Release the gate only when it is stationary. If the springs are damaged, the gate may drop uncontrollably. If the garage can only be accessed through this gate, arrange a suitable external release in advance.

  1. Pull the cord down until you hear a double click; the motor will disengage and the gate can be moved by hand.
  2. To re-engage the motor, pull the cord again until you hear a double click.
  3. Before issuing an electrical command, check that the motor is engaged, the area is clear, and the safety devices are working.

Manual release of the SPY moving motor using the cord

Maintenance and safe operation

Schedule a technical inspection every 6 months. Every month, check that the gate reverses when its bottom edge contacts a 50 mm-high object, following the instructions for your gate. If the test fails, do not use the automation system; call a technician.

Do not oil or grease the track or the internal metal profile at the sliding electrical contacts. Lubricant may impair electrical contact. At least once a year, with both the mains supply and battery disconnected, clean the track and check the insulation, fastenings, free manual movement, and photocell optics; then re-engage the motor and test it.

Keep remote controls out of children's reach. Do not go under a moving gate. If there is unusual noise, a safety fault, or a faulty spring, safely release the gate and arrange a repair. Dispose of electronics and batteries at an appropriate collection point.

Technical specifications: SPY650HS / SPYBOX BHS

ParameterValue
ApplicationGarage doors in a sheltered indoor area.
Motor / control unitSPY650HS / separate SPYBOX BHS.
Mains / motor230 V AC ±10 %, 50/60 Hz / 24 V DC via the track.
Maximum / rated force650 / 200 N.
Maximum speed0,24 m/s; under 8.5 s timing conditions.
Power consumption, maximum / rated300 / 190 W; maximum current draw 1.6 A.
Standby0.5 W under the conditions of the relevant mode.
Duty cycle30 cycles/h, 300 cycles/day, 12 consecutive cycles.
Ingress protection / temperatureIP41 / −20 to +55 °C.
Motor dimensions260 × 125 × 105 mm; separate control box 209 × 145 × 70.5 mm.
Supplied weightDepends on the specific configuration and supplied track; the kit details are shown at the top of the product page.
Gate areaSectional: up to 10.5 m²; up-and-over: up to 11.5 m²; dimensional and installation requirements.
Auxiliary power supply30 V DC, −20 % / +5 %, max. 100 mA; observe the specified positive and negative polarity.
Radio receiver included in this kitOXIBD + ON3EBD; 433.92 MHz, two-way BD.
LightingBuilt-in LEDs in the separate control box; SPYLIGHT is optional, max. 2, outside the trolley's path.

SPY650HS moving motor dimensions

SPY track and separate control unit dimensions

SPY Hi-Speed – drive demonstration

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about Fast and quiet NICE Spykit 650 HS BD drive

Product: Fast and quiet NICE Spykit 650 HS BD drive
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.