NICE Rox ROX600 is the successor to the ROBO 500
NICE Rox ROX600 drive is designed for sliding gates weighing up to 600 kg and a clear opening width of up to 8 m (recommended maximum length: 5 m). It has an electromechanical stop switch. The drive is non-reversible.
Key features of the ROX 600 drive: The ROX 600 is a 230 V drive that is easy to install and delivers high force.. The drive features manual limit-position adjustment, limited options for connecting additional devices, and limited programming capabilities. It is suitable, for example, for a holiday home or a location where integration with a smart home system is not required; instead, you need a workhorse that opens and closes the gate. It has one speed and manual force adjustment. It does not support partial opening. It is made as a replacement for older drives (NICE ROBO).
All accessories from the NICE ROBO drives can be used with NICE ROX drives..
So if you are replacing a NICE ROBO drive with a NICE ROX drive, you can keep all the existing accessories:
- photocells
- flashing light
- key switch
- all remote controls
Another advantage is the built-in receiver, which uses a rolling code but can also accept older fixed-code remote controls. It therefore works with FLOR coding (FLO2R-S, FLO4R-S), FLO (FLO2, FLO4) and SMILO (SM2). This makes it a good choice when you have a large number of fixed-code remote controls.
| Set NICE-ROX600-B contains: | ||||
|---|---|---|---|---|
|
1 × | NICE Rox ROX600 gate motor | NICE-ROX600-A | |
|
NICE Rox ROX600 drive with ROA40R10 control unit, built-in receiver, and a gate weight capacity of up to 600 kg. Suitable for passage widths of up to 8 m (recommended maximum gate length: 5 m). |
Details |
|||
|
1 × | NICE Flo2R-s remote control | NICE-FLO2R-S | |
|
Two-button remote control for operating a gate automatically from a distance. You can use it to control two devices or send two different commands to one device. |
Details |
|||
|
1 × | Installation Manual |
Download |
|
|
Installation manual with illustrated wiring diagrams and instructions for programming and pairing remote controls. |
||||
NICE ROX 600 technical specifications
| Power supply | 230 V - 50/60 Hz |
|---|---|
| Power consumption | 300 W |
| Motor current | 1.4 A |
| Protection rating | IP44 |
| Weight | 11 kg |
| Speed | 18cm/s |
| Force | 600 N |
| Recommended max. gate weight | 400 kg |
| Max. gate weight | 600 kg |
| Operating temperature | -20°C to +50°C |
| Protection rating | IP 44 |
| Control unit | ROA40R10 |
Manuals and documents to download
Types of electrical cables
| Connection | Cable type | Maximum length | |
|---|---|---|---|
| A | POWER SUPPLY | 3 x 1.5 mm² | 30m * |
| B | BEACON WITH ANTENNA | 1 cable: 2 x 1.5 mm² 1 RG58-type coaxial cable |
10m 10m (recommended < 5m) |
| D | PHOTOCELLS | 1 cable: 2 x 0.25 mm² (TX) 1 cable: 4 x 0.25 mm² (RX) |
30m 30m |
| E-F | KEY SWITCH | 2 cables: 2 x 0.5 mm² ** | 20m |
** If the power supply cable is longer than 30 m, a cable with a larger cross-section is required, for example 3 x 2.5 mm², and a safety earth connection must be provided near the gate operator.
** Two 2 x 2.5 mm² cables can be replaced with a single 4 x 0.5 mm² cable
Connecting to the control unit
Adding or removing devices
Devices can be added to or removed from the automatic system at any time. Different types of devices can be connected to the STOP input, as described in the following sections. After making changes to the gate operator configuration, the device learning procedure must be repeated.
STOP input
An input that immediately stops the movement, followed by a brief reversal.
Devices with normally open (NO) or normally closed (NC) contacts, or devices with a constant-resistance output of 8.2 kΩ, such as safety edges, can be connected to this input. The control unit detects the type of device connected to the STOP input during the device learning phase.
If the input status changes from the learned state, the gate operator stops the movement and briefly reverses. With the appropriate settings, more than one device, including devices of different types, can be connected to the STOP input:
- Multiple NO devices can be connected in parallel, with no limit on the number
- Multiple NC devices can be connected in series, with no limit on the number
- Multiple devices with a constant resistance of 8.2 kΩ can be connected in a daisy chain, with a single 8.2 kΩ terminating resistor
- NO and NC devices can be combined by connecting the two contacts in parallel; however, an 8.2 kΩ resistor must be connected to the NC contact (this also allows three devices—NO, NC and 8.2 kΩ—to be combined)
If the STOP input is used to connect safety devices, only devices with a constant-resistance output of 8.2 kΩ ensure Category 3 fault protection in accordance with EN 13849-1.
Photocells
To add a pair of photocells, proceed as follows: Connect the receiver (RX) power supply directly to terminals 8 and 9.
How the transmitters are connected depends on whether you want the photocells to operate with the Phototest function enabled or disabled.
Phototest is a control unit function that increases the reliability of safety devices and enables the control unit and safety photocells as a system to achieve Category 2 in accordance with EN 13849-1.
When a movement is initiated, the associated safety devices are checked, and the movement starts only if everything is working correctly.
If the test fails (for example, if sunlight blinds a photocell or a cable is short-circuited), the control unit treats this as a fault and does not carry out the movement.
To add a pair of photocells, connect them as described below
Wiring without the Phototest function:
Connect the receivers and transmitters directly to the control unit's accessory output (terminals 8 and 9).
Wiring with the Phototest function:
Connect the receivers directly to the control unit's accessory output (terminals 8 and 9). The photocell transmitters are powered not from the accessory output, but from the Phototest output between terminals 8 and 12. The maximum current draw from the Phototest output is 100 mA.
To use the Phototest function, synchronization must be enabled as described in the photocell installation instructions.