NICE ROX 600 – standalone drive for sliding gates (A)
| Product availability: | replaced | The product is no longer manufactured, but fortunately it has been replaced by a newer model. |
|---|
Description of NICE ROX 600 – standalone drive for sliding gates (A)
A replacement is available!
The NICE ROX600 drive is no longer manufactured. An alternative is the more powerful NICE ROX1000 drive.
The NICE Rox ROX600 is the successor to the ROBO 500 gate operator.
The NICE Rox ROX600 gate operator is designed for sliding gates weighing up to 600 kg and with a passage width of up to 8 m (recommended maximum length 5m). It has an electromechanical stop switch. The gate operator is self-locking.
Key features of the ROX 600 gate operator: The ROX 600 is a 230V gate operator that is easy to install and provides high force. The gate operator has manual limit position adjustment, limited options for connecting additional devices, and limited programming options. It is suitable, for example, for a holiday home or a location where smart home integration is not needed, but a reliable workhorse that simply opens and closes the gate is preferred. It has one speed and manual force adjustment. It does not support partial opening. It is manufactured as a replacement for older gate operators (NICE ROBO).
All accessories from NICE ROBO gate operators can be used with NICE ROX gate operators.
So if you are replacing a NICE ROBO gate operator with a NICE ROX, you can keep all the existing accessories:
- photocells
- warning light
- key switch
- all transmitters
Another advantage is the integrated receiver, which uses rolling-code technology but can also receive signals from older fixed-code remotes. It is therefore compatible with FLOR (FLO2R-S, FLO4R-S), FLO (FLO2, FLO4) and SMILO (SM2) coding. It is therefore suitable when you have a large number of fixed-code remotes.
NICE ROX 600 technical specifications
| Power supply | 230 V - 50/60 Hz |
|---|---|
| Power consumption | 300 W |
| Motor current consumption | 1,4 A |
| Protection rating | IP44 |
| Weight | 11 kg |
| Speed | 18cm/s |
| Force | 600 N |
| Recommended maximum gate weight | 400 kg |
| Maximum gate weight | 600 kg |
| Operating temperature | -20°C to +50°C |
| Protection rating | IP 44 |
| Control unit | ROA40R10 |
Manuals and documents to download
Types of electrical cable
| Connection | Cable type | Maximum length | |
|---|---|---|---|
| A | POWER SUPPLY | 3 x 1.5 mm² | 30m * |
| B | WARNING LIGHT WITH ANTENNA | 1 cable: 2 x 1,5 mm² 1 RG58-type coaxial cable |
10m 10m (recommended < 5m) |
| D | PHOTOCELLS | 1 cable: 2 x 0,25 mm² (TX) 1 cable: 4 x 0,25 mm² (RX) |
30m 30m |
| E-F | KEY SWITCH | 2 cables: 2 x 0,5 mm² ** | 20m |
** If the power supply cable is longer than 30 m, a cable with a larger cross-section is required, for example 3 x 2,5 mm², and a protective earth connection must be provided near the gate operator.
** Two 2 x 2,5 mm² cables can be replaced with a single 4 x 0,5 mm² cable
Connection to the control unit
Adding or removing devices
Devices can be added to or removed from the automatic system at any time. Different types of devices can be connected to the STOP input, as described in the following sections. After making changes to the configuration of the automatic gate operator, repeat the device recognition procedure.
STOP input
An input that immediately stops the manoeuvre, followed by a brief reversal.
Devices with normally open (NO) or normally closed (NC) contacts, or devices with a constant resistance output of 8,2 kΩ, such as safety edges, can be connected to this input. The control unit detects the type of device connected to the STOP input during the device recognition phase.
If the detected state changes from the recognised state, the gate operator stops the manoeuvre and briefly reverses. With the appropriate settings, more than one device, including devices of different types, can be connected to the STOP input:
- Multiple NO devices can be connected in parallel, with no limit on the number of devices.
- Multiple NC devices can be connected in series, with no limit on the number of devices.
- Multiple devices with a constant resistance of 8,2 kΩ can be connected in a cascade, with a single 8,2 kΩ end-of-line resistor.
- NO and NC devices can be combined by connecting the two contacts in parallel; however, an 8,2 kΩ resistor must be connected to the NC contact. This also allows three devices to be combined: NO, NC and 8,2 kΩ.
If the STOP input is used to connect devices with a safety function, only devices with a constant resistance output of 8.2 kΩ ensure Category III fault safety in accordance with EN 13849-1.
Photocells
To add a pair of photocells, proceed as follows: Connect power to the receivers (RX) directly to terminals 8 and 9).
How the transmitters are connected depends on whether you want the photocells to operate with the Phototest function enabled or disabled.
Phototest is a control unit function that increases the reliability of safety devices and enables the combination of the control unit and safety photocells to achieve Category II in accordance with EN 13849-1.
When a manoeuvre is initiated, the associated safety devices are checked, and the manoeuvre starts only if everything is in order.
If the test fails (for example, if a photocell is blinded by sunlight or there is a short circuit in the cables), the control unit detects a fault and the manoeuvre is not carried out.
To add a pair of photocells, connect them as described below.
Wiring without the Phototest function:
Connect the receivers and transmitters directly to the control unit accessory output (terminals 8 and 9).
Wiring with the Phototest function:
Connect the receivers directly to the control unit accessory output (terminals 8 and 9). Power for the photocell transmitters is not taken from the accessory output, but from the Phototest output between terminals 8 and 12. The maximum current draw from the Phototest output is 100 mA.
To use the Phototest function, synchronisation must be enabled as described in the photocell installation instructions.