Connecting an external receiver of another brand to the NICE Robus RBS drive

An external receiver from another brand generally requires a power supply and a relay output. Robus RBS operators provide 24 V DC, and the relay output connects to the same input as a wired push button.

Step 1. Powering the external receiver

If you need to connect additional devices to the operator that require an external power supply (e.g. external receiver, indicator lighting, key switch, magnetic cards, etc.), connect the device as shown in the diagram. The supplied voltage is 24 V DC, -30% to +50%, with a maximum current of 100 mA.

Power supply for the NICE Robus RB400 operator                      robus pin

        (NICE RBA3)                                  (NICE RBA3R10)

Step 2. Relay input

Connect the relay to the SBS input (labelled P.P. on older control units). Alternatively, you can connect the relay to the OPEN input and use the automatic closing function. In this case, the external receiver will only open the gate, and automatic closing will close it after a pause.  
Next, perform the “recognition of connected operator devices” procedure on the Robus, as follows:

Step 3. Recognition of connected operator devices

Whenever you connect, disconnect, or change the wiring of additional devices on the BlueBUS and STOP inputs, the additional device recognition phase must be carried out.

  1. Press the “Open” and “Stop/Set” buttons and hold them down
  2. As soon as L1 and L2start flashing rapidly, release the buttons
  3. Wait a few seconds for the control unit to complete the device recognition process.
  4. If everything went well, the STOP LED should be lit, and L1 and L2 should turn off. Alternatively, L3 and L4may start flashing if you have not yet completed the gate leaf length recognition phase.

Example of wiring a GSM module GSM-05 to a NICE RBA3R10 control unit (NICE ROBUS operator):

Example of wiring a GSM module GSM LITE 3+ to a NICE RBA3R10 control unit (NICE ROBUS operator):