If you don’t want to read the entire manual for the NICE Wingo gate opener with the MC424LR10 control unit (with MCA2R10), you can get the opener up and running in just a few minutes using this simplified procedure.

We assume that the swing gate can be opened and closed manually and, of course, that its movement is limited by stops at both end positions—see Limiting the movement of a swing gate with stops.

The easiest approach is to get the motors running with the control unit alone, without any accessories; you can connect those later, one at a time. But you can connect the accessories right away if you like; it doesn’t matter when you do it, as anything can be connected or disconnected at any time. You can always reset the opener to its factory settings.

Step 0. Wiring

Power supply cable
L terminal – live wire from the power supply cable
N terminal – neutral wire from the power supply cable
Terminal marked with the earth symbol – earth wire from the power supply cable

Motors
First, identify which motor is the primary motor and which is the secondary motor. The primary motor is the one that closes first.
For outward opening, reverse the polarity (positive and negative) on both motors. If you have only one motor, connect it to M2.

Warning light
Connect the two-core cable from the warning light, from the terminal marked with the bulb symbol, to terminals 1–2 on the control unit. If you are not installing a warning light, leave terminals 1–2 unconnected.

Antenna
A temporary antenna wire is factory-fitted to the control unit, connected to the far-right terminal marked with the antenna symbol. If you have a warning light, you can disconnect this wire and connect the antenna supplied with the warning light instead.

Photocells
The control unit comes with yellow jumper wires between terminals 8–9, 9–11 and 10–11.
If the gate opens inward and the photocells are on the outside, remove the yellow jumper between terminals 10–11, leaving only the jumpers between 8–9 and 9–11.

For other configurations (more photocells, photocells on the inside, or outward opening), see more Connecting photocells to the NICE MC424L control unit. Otherwise, connect as follows:

  • Connect terminal 6 on the control unit to terminal 2 on each photocell.
  • Connect terminal 7 on the control unit to terminal 1 on each photocell.
  • Connect terminal 8 on the control unit to terminal 4 on the RX photocell.
  • Connect terminal 10 on the control unit to terminal 5 on the RX photocell.

Step 1. Starting up the gate openers

  1. Disconnect the control unit from the power supply. The easiest way is to remove the power fuse next to the power supply cable.
  2. Set the operator model selector to match your gate opener model.
    Gate opener model DIP switch settings
    General All switches down, switch 1 up
    WG2024 All switches down, switch 2 up
    WG3524 First two switches up, last two down
    WG4024 All switches down, switch 3 up
    WG5024 Switches 1 and 3 up, 2 and 4 down
    TOO3024 Switches 1 and 4 down, 2 and 3 up
    TOO4524 All switches up, switch 4 down
    SFAB2024 (XME2024) All switches down, switch 4 up
  3. Unlock both motors, move them manually to approximately halfway so the gate is neither open nor closed, then lock the motors and move the leaves slightly until the gearboxes engage.
  4. Reconnect the control unit to the power supply.
  5. Run the gate leaf travel learning procedure — Press and hold the second (STOP/SET) and third (CLOSE) buttons on the control unit simultaneously. Release them when the leaves start moving.
  6. The leaves will perform the following sequence (the learning procedure can be stopped at any time by pressing the STOP button):
    1. Both leaves open slightly.
      Note: If they move in the opposite direction, i.e. close slightly, stop the movement by pressing STOP, disconnect the control unit from the power supply, and reverse the polarity on both motors. If one leaf starts opening and the other starts closing, reverse the polarity only on the motor that started closing. To reverse the polarity, swap the wires connected to the + (positive) and – (negative) terminals in that motor’s three-terminal block.
    2. The lower leaf closes fully.
      Note: If the wrong leaf starts moving (i.e. the upper one), stop the movement by pressing STOP, disconnect the control unit from the power supply, and swap the complete M1 and M2 motor terminal blocks.
    3. The upper leaf closes fully.
    4. The upper leaf starts opening, followed shortly by the lower leaf.
      Note: If the delay is insufficient, it can be changed in the programming settings; see section 5.2.2, LED L6 “Leaf delay”.
    5. Both leaves open fully.
    6. The lower leaf starts closing, followed shortly by the upper leaf.
    7. The leaves close fully, and the control unit stores their end positions in memory.
  7. Done.