Simplified procedure for wiring and commissioning NICE Rox gate operators

Applies to the control unit ROA40R10.

If you don't feel like reading the entire manual for Rox operators, you can get your NICE Rox operator up and running in just a few minutes using this simplified wiring and start-up procedure.

We assume that the sliding gate moves up and down and that you have completed the steps for installing the rack, installing the operator, and fitting the end stops to the rack.

In other words, with the operator released, the gate can be moved by hand, and the operator's limit switch activates in both the fully open and fully closed positions.

The easiest way is to get the operator running on its own, without any accessories, which you can connect one by one later. But feel free to connect the accessories right away; it makes no difference when you do it, and you can connect or disconnect anything at any time. You can always reset the operator to its factory settings.

Step 0. Wiring

Power supply cable
Terminal L – live wire from the power supply cable
Terminal N – neutral wire from the power supply cable
Grounding – The operator's enclosure contains a flat connector. Secure the grounding wire from the power supply cable to it, then slide it onto the earth terminal.

Flashing warning light
Connect the two-core cable from the warning light, from the terminal marked with a light-bulb symbol, to terminals 4–5 on the control unit. If you are not installing a warning light, leave terminals 7–8 unused.

Antenna
Connect the antenna's coaxial cable to terminals 1 and 2 on the control unit (top left): connect the coaxial core to terminal 1, then twist the shielding together with your fingers and connect it to terminal no. 2. If you don't have an antenna, connect a short piece of wire to terminal 1 as a temporary antenna. Or leave it disconnected; you can simply skip this step.

Photocells
If you don't have photocells, bridge inputs 9 and 11 on the control unit. If you have photocells, connect them as follows:

Connect terminal 1 from each photocell to terminal 9 on the control unit.
Connect terminal 2 from each photocell to terminal 8 on the control unit.
Connect terminal 4 of the RX photocell to terminal 9 on the control unit.
Connect terminal 5 of the RX photocell to terminal 11 on the control unit.

Do not interrupt any circuits on the photocell circuit board. More about wiring photocells.

Step 1. Getting the operator running

  1. Disconnect the operator from the power supply.
  2. Set DIP switch 8 to OFF. 
  3. If you are standing inside the property and the gate opens to the right (with the operator on the right-hand side), continue to the next step. If the gate opens to the left (with the operator on the left-hand side), unplug, rotate 180°, and reconnect:
    • the three-pin limit-switch connector (the one with the red, blue, and black wires),
    • and the three-pin motor connector (the one with the green, blue, and black wires).
  4. Manually move the gate to roughly halfway along its travel (so it is neither open nor closed), engage the operator, and pull the gate leaf slightly so that the gearbox engages.
  5. Reconnect the operator to the power supply.
  6. With the factory settings (or after a reset), the OK LED on the control unit should flash green once per second, and the LED next to terminal 11 should be lit.
  7. Run the connected-device check: Press and hold the PROG button. The OK LED will start flashing green more quickly. Keep holding PROG, and release it when the OK LED stays lit green. The OK LED will then flash green three times to indicate that the inputs have been checked successfully. At the same time, the LED next to terminal no. 10.
    If the OK LED starts flashing red, the photocells or the STOP input are wired incorrectly.
  8. Now, repeatedly pressing the SbS button should make the gate open, close, and stop.
  9. Great, you've got the operator running!

If everything is working as it should, great! You can connect the photocells, warning light, key switch, or other accessories, and pair the remote controls. If something doesn't seem right, you can fine-tune the motor:

Step 2. Fine-tuning the motor and configuring its functions

Setting the operating time:

The Rox operator works on the basis of an operating-time setting. Turning the TL trimmer sets how long the motor runs. If you turn the TL trimmer fully counterclockwise, the motor will run for about 3 seconds; if you turn it fully clockwise, it will run for about 60 seconds. Set this trimmer so that the operating time is longer than the time the operator takes to move the gate from one end of its travel to the other.

Setting the force:

Turn the F trimmer clockwise to increase the motor force, or counterclockwise to reduce it. The force should be set as a compromise: the gate should not push too hard if it encounters an obstacle, but the force must also be high enough for the gate to move reliably.

Setting automatic closing

Set DIP switch 1 to OFF and DIP switch 2 to ON. Turn the TP trimmer to set the delay before the gate closes. If you turn the TP trimmer fully counterclockwise, the gate will close automatically after about 3 seconds; if you turn it fully clockwise, the gate will close after about 120 seconds. 

Warning: Every time you change a DIP switch setting, you must run the connected-device check.

For other functions, refer to the manual; they are generally not used.

Pairing a remote control with the NICE Rox operator

The Rox receiver is excellent because it can store all NICE remotes using unidirectional coding: Flo fixed code, FloR rolling code (and, of course, O-Code), as well as Smilo. It's not an either-or choice. It supports them all at the same time.

The only thing the Rox receiver does not support is bidirectional operation. So if you have an ON3EBD remote, switch it to unidirectional mode.

As with all NICE devices, it also matters here

  • whether you want the remote control to operate only this operator,
  • or other gates as well. 

I want to use the remote to operate only this operator

All the buttons are stored in the operator at once. Repeatedly pressing the first button will open, close, and stop the entire gate; the second button will open the gate to a pedestrian opening of just one metre; the third button, if available, will only open and stop it; and the fourth will only close and stop it. Procedure:

  1. On the Rox, press and hold the pairing button. Release it when the pairing LED lights up. 
  2. The LED will stay lit for 10 seconds. During those 10 seconds, press and hold any button on the remote control. Release it when the pairing LED starts flashing.
  3. The LED will light up again. Either press and hold a button on another remote control, or wait for the LED to turn off. That's it.

I want to use the remote to operate other gates as well

In this case, pair just one button with the Rox:

  1. On the Rox, press the pairing button once without holding it. The pairing LED will start flashing at one-second intervals.
  2. The LED will flash for 10 seconds. During those 10 seconds, press and hold the button on the remote control that you want to use for the operator. Release it when the pairing LED gives three longer flashes.
  3. The LED will flash again. Either press and hold a button on another remote control, or wait for the LED to turn off. That's it.

Note: If needed, the receiver can be completely erased.