NICE MC800 control unit wiring

Which types of cables should be used for each component in a drive system with a NICE control unit MC800 can be found in the following “shopping” list:

Minimum requirements:

  • Power supply to the control unit – 3×1.5 mm2. If the power cable is longer than 30 m, use a larger cross-section, for example 3 x 2,5 mm2
  • Each motor – 4 ×1,5 mm2 (stranded)

Optional accessories:

  • Photocells with conventional wiring:
    • TX transmitter: 2×0,5 mm2
    • RX receiver: 4×0,5 mm2
  • BlueBus photocells:
    • TX transmitter: 2×0,5 mm2
    • RX receiver: 2×0,5 mm2
  • Alternatively, a two-core cable (2x0,5 mm2) if you want to open the gate with a standard switch, for example.
  • Any other BlueBus accessories: 2×0,5 mm2. If the BlueBus cable is longer than 20m, use 2×1 mm2