NICE Tub4000 – drive for a sliding gate weighing up to 4,000 kg and measuring up to 30 m
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
for the question
€2,361.16 including VAT
| Weight |
|---|
| 60 kg |
Description of NICE Tub4000 – drive for a sliding gate weighing up to 4,000 kg and measuring up to 30 m
NICE TUB4000 is a standalone industrial operator for a sliding gate weighing up to 4,000 kg and measuring up to 30 m. It has a three-phase 400 V AC motor, built-in control unit DPRO500, mechanical brake, fan cooling and a pinion for a module 6 rack. It is non-reversible; in the event of a power failure, the gearbox can be released and the gate moved manually.
When to choose the NICE TUB4000
It is designed for large, heavy sliding gates at industrial premises. When choosing, consider the gate's weight, actual leaf length, resistance to movement, wind exposure, and the number of opening and closing cycles. The gate must move smoothly by hand, must not start moving on its own, and must have solid mechanical stops in both directions.
| Gate weight | Up to 4,000 kg. |
|---|---|
| Gate length | Up to 30 m; the permitted number of cycles per hour decreases as the length increases. |
| Power supply | 3~ 400 V AC ±10%, 50 Hz; protective earthing required. |
| Rack | Module 6. The module 4 rack used with smaller operators is not interchangeable. |
Cycles per hour by gate leaf length
| Leaf length | Max. cycles/h |
|---|---|
| Up to 5 m | 42 |
| Over 5 up to 10 m | 21 |
| Over 10 up to 15 m | 14 |
| Over 15 up to 20 m | 10 |
| Over 20 up to 25 m | 8 |
| Over 25 up to 30 m | 7 |
One cycle is one complete opening and closing. When designing the system, comply with the dimensional, weight and operating limits together; the maximum weight alone does not confirm suitability for a particular gate. For example, a 30 m gate leaf is limited to 7 cycles/h.
When replacing an existing operator, also check the accessories, wiring arrangement and available installation space.
Built-in DPRO500 control unit
NICE DPRO500 is built into the TUB4000. It has four DIP switches, Open/Stop/Close buttons and an SM connector for a radio receiver. The TUB4000's end positions are determined by mechanical limit switches; the ENCODER connector is not used in this version.
The ability to configure the control unit itself for a different power supply does not turn this motor into a single-phase 230 V operator.. Connect the TUB4000 in accordance with its rating plate and the wiring diagram for the three-phase 400 V version.
What the operator includes and what you need to add
- Geared motor with built-in controls, mechanical brake and fan.
- Pinion module 6, 18 teeth.
- Release mechanism for manual gate movement.
- For a complete automation system, you will need a suitable rack, anchors, mechanical stops and safety devices selected for the specific gate. Remote control requires a compatible receiver and transmitters.
When you order, we can match the installation hardware, rack and accessories to your specific setup. The operator alone is not a complete automatic gate system.
Dimensions and installation space
The drawing specifies a height of 580 mm, a width of 480 mm, a housing depth of 230 mm and an overall dimension to the pinion of 305 mm. The pinion axis is shown on the drawing at a height of 160 mm. Dimensions are in millimetres. Keep the access door, manual release, limit switch and electrical controls accessible.
Installing the base, motor and rack
Before starting work, disconnect all power supplies and secure them against being switched on. The foundation must be solid, level and protected from flooding. When preparing the conduits, prevent water and condensation from entering the control unit.
- For an existing suitable foundation, use anchors appropriate for the substrate. For a new foundation, prepare an excavation and conduits; determine the foundation dimensions based on the installation location.
- Position the base plate with its four anchors parallel to the gate leaf and level. The anchor detail specifies a thread projection of 55–60 mm. Allow the concrete to cure fully.
- Place the motor on the plate, align it with the gate leaf and secure it with four nuts and washers. Release the gearbox before proceeding.
- Fit the module 6 rack progressively along the entire travel path. Maintain a 2–3 mm clearancebetween the rack and pinion; the gate's weight must not be carried by the operator.
- Move the gate manually several times. Check for proper meshing, smooth travel across rack joints and consistent clearance along the entire length.
Limit switches and mechanical stops
Two brackets are fitted to the rack to operate the limit-switch lever for opening and closing. They do not replace the gate’s fixed mechanical stops. The lever must move freely, and the brackets must actuate it in the correct direction.
After the limit switch trips, allow for a run-on distance of approximately 2–3 cm. Adjust the brackets so the gate stops safely before the mechanical stops; also check the run-on distance with the motor warmed up.
If the run-on distance is longer, check and adjust the mechanical brake. The power supply must be disconnected before making adjustments. According to the instructions, first tighten the nut on the shaft by half a turn clockwise; overtightening can lock the motor. Repeat the tests after making the adjustment.
Manual release during a power outage
Release the drive only when the gate is stationary and the power is disconnected. Secure the gate leaf to prevent it from moving on its own. Demonstrate the procedure and hand over the keys at commissioning.
- Open the front cover of the drive as shown.
- Insert the Allen key into the shaft and fully loosen the internal screw as shown.
- Remove the key and close the door. You can carefully move the gate by hand.
- To re-engage the drive, follow the procedure in reverse. Check that the drive gears are engaged and the door is closed; its safety microswitch must be activated.
Wiring for a typical configuration
| Connection | Cable | Length |
|---|---|---|
| Power supply to the drive | 4 × 1.5 mm² | Up to 30 m |
| Warning light | 2 × 1 mm² | Up to 20 m |
| Antenna | RG58 coaxial cable | Recommended: less than 5 m |
| Photocell transmitter TX | 2 × 0.25 mm² | Up to 30 m |
| Photocell receiver RX | 2 cables, 2 × 0.25 mm² each | Up to 30 m |
| Key switch | 2 cables, 2 × 0.25 mm² each | Up to 50 m |
| Fixed / moving safety edge | Depending on the edge and interface | Depending on the specific device |
Two 2 × 0.25 mm² cables can be replaced with one 4 × 0.25 mm² cable. For a supply run longer than 30 m, specify a larger cross-section and appropriate grounding. For low-voltage photocell wiring over 30 m, the instructions require shielding grounded only at the control-unit end. Cables must be suitable for the environment; for outdoor installation, the manufacturer specifies, for example, H07RN-F.
The cross-sections shown are taken from the table for the typical TUB4000 configuration. For a 230 V warning light wired according to diagram NDA040, a separate neutral conductor N is also required. A four-core supply cable with 3 phases + PE does not include it. The supply and fuse protection must therefore be designed to match the actual equipment.
A moving safety edge needs a connection that remains functional while the gate leaf is moving. Determine the number of conductors and the interface according to the type of safety edge; the two-core example from an older typical configuration cannot be used for every OSE edge.
DPRO500 wiring and terminal polarity
All wiring changes, receiver insertion and service-interface connections must be made with the power disconnected. Keep 400 V power cables separate from low-voltage signal cables. Protective earth PE, neutral N and signal GND have different functions.
| Connector / terminal | Function |
|---|---|
| LINE L1–L2–L3 / PE | Three-phase 400 V supply and protective earth. |
| MOTOR U–V–W | Motor connection; this is not DC polarity (+/−). |
| INPUT 8 COMMON | Common point for the control inputs and +24 V DC for accessories. |
| STOP 7 GND | Negative (−) / 0 V DC for accessories. Between INPUT 8 (+) and STOP 7 (−), the voltage is 24 V DC, max. 100 mA. |
| INPUT 9 OPEN | NO volt-free opening contact relative to 8 COMMON. |
| INPUT 10 CLOSE | NO volt-free closing contact relative to 8 COMMON. |
| INPUT 11 ING1 / PHOTO | Photocell configured at the factory: NC volt-free contact relative to 8 COMMON. Another function can be set via OVIEW. |
| ALT | NC safety stop input; not a power supply for accessories. |
| SAFE | Motor thermal protection on versions with mechanical limit switches. |
| LIMIT SWITCH 1 / 2 / 3 / 4 | Common / open / pre-limit close / close contact, depending on the motor wiring. |
| STOP 5 / 6 / 7 | Safety-edge input: 5 +12 V DC (brown OSE wire), 6 signal S (green), 7 GND − (white). |
| STOP 6–7, 8k2 edge | Connect an 8.2 kΩ resistive edge between the signal and GND as shown in the diagram. It does not use power terminal 5. |
| PUSH BUTTONS | Open / Stop / Close buttons on the cover. |
| OXI / SM | Plug-in radio receiver of the appropriate type. |
| IBT4N | Connect the OVIEW programmer via the IBT4N interface. |
| OUT / NDA040 | Expansion with two relay outputs featuring volt-free contacts; functions are programmed via OVIEW. |
| ENCODER | Not used in the TUB4000 with mechanical limit switches. |
COMMON 8 is a positive low-voltage supply, not a mains neutral conductor N. For an OSE edge, do not confuse the 12 V supply from terminal 5 with the 24 V supply for photocells. Do not connect mains voltage to the control inputs INPUT or ALT, or to the photocell contacts. mains voltage. The NDA040 relay outputs are a separate circuit for the load, as shown in the beacon diagrams.
8k2 or OSE safety edge
When triggered, the safety edge input stops movement and initiates a brief reversal. During setup, the DPRO500 detects the connected type 8k2 or OSE. If the edge or its wiring is changed, the detection procedure must be repeated. During setup, at the STOP SAFETY EDGE input at least one safety device must be connected; a photocell on INPUT 11 alone is not a substitute. Do not replace the safety edge with a wire jumper.
NO or NC edges must be wired with an 8.2 kΩ resistor exactly as specified in the instructions. Multiple edges should be configured as a single monitored circuit with the appropriate termination; do not connect them arbitrarily. For semi-automatic operation, the instructions require an active safety edge; automatic operation also requires at least one pair of photocells.
Photocells for DPRO500
Use relay-type photocells with a suitable power supply, such as NICE EPM. The DPRO500 does not have BlueBUS, so the EPMB cannot be connected to an INPUT as a substitute for the EPM. For the basic PHOTO function, ING1 remains configured as a photocell by default.
Choose the photocell range to suit the width of the passage. The EPM has a useful range of 15 m; the manufacturer specifies a maximum of 30 m. For a TX–RX distance greater than 10 m, adjust the +10m jumper on the RX receiver as specified in the EPM instructions. Fog, rain and dust can reduce the range by 50%, so the maximum stated range of 30 m does not guarantee reliable coverage across a passage of the same width. Choose a suitable model for the specific site and check that it works correctly.
| EPM | DPRO500 |
|---|---|
| TX and RX 1 | Plus + → INPUT 8 COMMON, +24 V DC. |
| TX and RX 2 | Minus − → STOP 7 GND, 0 V DC. |
| RX 4 COM | → INPUT 8 COMMON. |
| RX 5 NC | → INPUT 11 ING1 / PHOTO. |
| RX 3 NO | Not used for the PHOTO safety function. |
| Current draw | An EPM pair draws approximately 55 mA max. The control output has a total maximum rating of 100 mA; two such pairs require a different power supply design. |
Mount the photocells opposite each other and check their alignment. When using multiple pairs, assess mutual interference and total current draw. The EPM synchronisation described for AC power does not work automatically when powered by DC from the DPRO500. If a separate power supply is needed for the photocells and safety circuits, size it according to their current draw and wiring.
Beacon and status indicator
The DPRO500 uses an expansion card for an external beacon: NDA040. Its relay outputs are volt-free; they do not provide power to the beacon. Set the function using OVIEW. For 230 V AC NICE ELAC the original diagram below shows the wiring, including the N wire from the mains supply. Do not connect the ELAC to 400 V between phases.
The diagram shows the beacon and its antenna in functional terms. The current ELAC has its own terminals, as specified in its instructions. AERIAL denotes the antenna; connect the beacon power supply to FLASH. There is no DC polarity (+/−) with AC power.
The separate status indicator on the button board has terminal 1 negative − and terminal 2 positive +, 24 V DC, max. 5 W and a maximum cable length of 2 m. This output is not short-circuit protected and does not replace the power supply for the beacon or photocells.
First power-up and TUB4000 setup
Before setup, adjust the mechanical limit-switch brackets and check the brake, gearbox lock and safety equipment. Start with all four DIP switches set to OFF. The travel path must be clear. For a long gate, also check the movement time limit; the original setting of 60 s may not be long enough for a full run and can be adjusted using OVIEW.
- After powering on, check the green LED L2 OK, which should flash regularly, about once per second. The red SAFETY must remain lit. Also check the status of the photocells. If the status is incorrect, switch off the power and fix the fault.
- To detect the safety input, set DIP 1 ON. The green LED flashes rapidly and the red LED is off. Hold STOP for about 3 s, until the red LED stays lit, then release the button.
- Continue immediately with position setup, without interruption. Set DIP 1 to OFF; leave the other DIP switches set to OFF. Hold Open until the gate is fully open and stops at the opening limit switch, then hold Close until it is fully closed and stops at the closing limit switch.
- If Open moves the gate in the opposite direction, stop immediately and switch off the power. Swap the motor wires V and W as shown in the diagram, then check the direction and correct operation of the limit switches again.
- If the red LED flashes three times and pauses, acknowledge the fault by pressing STOP. Then, with the power off, correct the swapped opening and closing limit-switch connections and repeat the detection procedure. Nine flashes indicate a position setup error; after resolving the cause, follow the instructions to clear the controller memory and repeat safety device and position detection.
- Repeat the movement, run-on, safety edge, photocell and STOP tests. Enable the selected semi-automatic or automatic mode only after a successful check.
Safety device detection and position setup are performed consecutively. If interrupted, the detection procedure must be repeated. Do not confuse the SAFETY safety-chain LED with the red diagnostic LED L1 WARNING.
DPRO500 operating modes
| DIP 1 / 2 / 3 / 4 | Mode |
|---|---|
| OFF / OFF / OFF / OFF | Hold-to-run operation: movement while the relevant control is held. |
| ON / any / OFF / OFF | Device and position recognition as described above. |
| OFF / OFF / OFF / ON | Industrial mode: semi-automatic opening, hold-to-run closing; after position learning. |
| OFF / OFF / ON / OFF | Semi-automatic mode; after position learning. |
| OFF / OFF / ON / ON | Automatic mode with adjustable pause; after position learning. |
DIP 2 changes the encoder direction. Do not use it on the TUB4000 with mechanical limit switches to correct the motor's incorrect direction. If you configure the modes via OVIEW, the manual requires the DIP switches to be OFF.
Setting the automatic closing pause
- After successful position learning, set DIP 3 and 4 to ON.
- Send a command to open fully. Measure the required pause from the moment the open position is reached.
- When the pause has elapsed, send a closing command; the control unit will store the time.
- To change it, set DIP 3 and 4 to OFF and then back to ON, and repeat the procedure. Setting DIP 4 to OFF deletes the stored pause.
Advanced settings, the ING1 input function, the time limit and relay outputs can be managed via IBT4N and OVIEW. Connect and disconnect the interface with the power off.
TUB4000 remote control
The control board has an SM connector for SMXI, SMXIS, OXI receivers or a compatible equivalent. NICE OXIBD is selected together with compatible transmitters according to the radio protocol. Insert the receiver only with the power disconnected; transmitter codes are stored in its memory.
| Receiver output in basic mode | DPRO500 command |
|---|---|
| 1 | Step-by-step |
| 2 | Partial opening; factory setting is halfway, with the option to change it |
| 3 | Open |
| 4 | Close |
With the OXIBD, the external antenna connects directly to the receiver terminals, as described in its manual; the older antenna diagram on the control board does not automatically apply to it. Follow the specific receiver's instructions for pairing and deleting. Resetting the DPRO500 does not replace managing transmitters in the receiver.
TUB4000 accessories
| Item | Selection |
|---|---|
| Photocells | NICE EPM with an NC relay contact; observe DC polarity and the 100 mA output current rating. |
| Flashing light | NICE ELAC 230 V AC via NDA040 and a suitably powered relay circuit, as shown in the diagram. |
| Safety edge | 8k2 resistive or OSE, depending on the DPRO500 safety-edge input. |
| Radio receiver | NICE OXIBD or another compatible supported SM receiver; select compatible transmitters as well. |
| Programming | NICE IBT4N + OVIEW for configuration and diagnostics. |
| Control unit | NICE DPRO500 with enclosure as a separate service item. The PIU expansion board from the old A500 is not a replacement for the NDA040. |
Two opposing sliding gate leaves
Each leaf requires its own motor, control unit and limit switches. Two DPRO500 units are interconnected using a separate diagram in the manual; set Open mode via OVIEW as condominium mode. Activation of the safety edge, red STOP and thermal protection in this configuration affects only the corresponding leaf. Design protection for both leaves as a complete system.
DPRO500 diagnostics
Count the group of flashes between pauses and note the LED color. The green L2 OK indicates operating status; the red L1 WARNING indicates a fault. The SAFETY LED stays lit when the safety circuit is closed; if it goes out, check ALT, the STOP button on the cover, thermal protection and the release mechanism.
| Green L2 | Meaning |
|---|---|
| Regular flashing, approximately once per second | Normal control unit operation after the initial signal. |
| 2 flashes | Photocell activated or passage clearance not granted; check for obstructions and alignment. |
| 4 flashes | STOP or ALT activated; identify the cause. |
| 6 flashes | Limit on the number of operations. |
| 9 flashes | Automation locked; unlock it with the corresponding command after checking the cause. |
| Red L1 | Meaning and action |
|---|---|
| 2 flashes | Safety test error; check the safety edge and repeat its recognition procedure. |
| 3 flashes | For TUB4000 units with mechanical limit switches, acknowledge the fault with the STOP button and, with the power off, correct the swapped open/close connections. Do not correct this using encoder DIP 2. |
| 4 flashes | Safety limit switch overrun; after safely disconnecting power, manually move the gate back to an intermediate position, check the settings and secure the gearbox. Then resume operation by pressing the STOP button. |
| 5 flashes | Internal memory error; have it checked by a qualified technician. If the error persists, reset and reconfigure the unit or service the control board. |
| 6 flashes | Contactor fault; check the power circuit and control unit. |
| 7 / 8 flashes | Communication / encoder fault. The TUB4000 uses mechanical limit switches; check the selected configuration and control unit. |
| 9 flashes | Position learning error; eliminate the cause, erase the control unit memory and repeat recognition of the safety device and positions. |
| 10 flashes | Movement time exceeded; check for obstructions, the travel path, and the time limit in OVIEW. |
After power-up, rapid flashing of both L1 and L2 for 5 s indicates empty memory. When positions have been learned, the green LED flashes rapidly for 2 s; one slow red flash confirms 8k2, and two confirm OSE. Alternating rapid red and green flashes indicate a firmware update; four simultaneous flashes indicate that an update is pending.
Complete settings reset
Only reset after troubleshooting. This erases the learned control data and restores the default settings. Set DIP switches 1–4 to ON, hold STOP for approximately 3 s until both the red and green LEDs are steadily lit, then release STOP. After the reset is complete, set all DIP switches back to OFF. Then relearn the safety devices and positions, set the operating mode, and perform safety tests.
Safety, testing, and maintenance
Before handing over the gate, repeatedly test opening, closing, stopping, limit switches, all photocells, safety edges, and the emergency stop. Check the stopping distance and the safety of the entire travel path; if protection relies on limiting impact force, perform the relevant measurement as well. Adjusting the trimmer or wiring a photocell alone does not replace testing the complete gate.
Follow the maintenance schedule provided by the installer according to the intensity of use. Check the fixings, corrosion, pinion and rack, mechanical brake, limit switches, cables, covers, and all safety devices. After maintenance, perform an operational and safety test.
With the power switched off, users may remove leaves and stones from the travel path and gently clean accessible surfaces and photocell lenses with a slightly damp cloth. If the gate makes unusual noises, jerks, or malfunctions, take it out of service and contact a service technician. Do not bypass safety inputs. Keep remote controls out of children's reach, and enter the passage only once the gate is fully open and has stopped. An open pedestrian gate built into the gate leaf must disable the motor.
TUB4000 technical specifications
| Model | NICE TUB4000 |
|---|---|
| Control unit | DPRO500, integrated |
| Power supply | 3~ 400 V AC ±10 %, 50 Hz |
| Max. power consumption | 580 W |
| Rated current | 1.6 A |
| Rated torque | 65 Nm |
| Peak torque | 216 Nm |
| Speed at rated torque | 0.16 m/s (approximately 9.5 m/min) |
| Max. gate weight / length | 4,000 kg / 30 m; suitability depends on operating conditions |
| Number of cycles | According to the length table |
| Pinion | Z = 18; module 6; tooth pitch 18.8 mm |
| Protection rating | IP54 |
| Insulation class | I; protective earthing required |
| Operating temperature | −20 to +55 °C |
| Mounting dimensions | Drawing in mm: height 580, width 480, housing depth 230, depth to pinion 305 |
| Weight | 60 kg |
Technical values apply at an ambient temperature of 20 °C ±5 °C. When selecting spare parts and a control unit, provide the exact model and version shown on the nameplate.
Help with selecting and completing your setup
Contact us with the gate's length and weight, the number of cycles per hour and per day, the available power supply, and a photo of the installed control unit. We can help you choose the rack, receiver, and safety accessories.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]