NICE DPRO500 - control unit for the TUB4000 operator with box


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE DPRO500 - control unit for the TUB4000 operator with box
NICE-DPRO500
in stock
€295.05 excluding VAT
€362.91 including VAT

 pcs
Weight
5,30 kg

Description of NICE DPRO500 - control unit for the TUB4000 operator with box

Control unit with enclosure NICE DPRO500 for operating the NICE TUB4000. The buttons on the cover let you open, stop and close the gate. Depending on the operating mode selected, the control unit can operate with a hold-to-run command, in semi-automatic mode, or with automatic closing after a pause.

Quick navigation
Use and equipmentEnclosure installation
Power supply and motorTerminals and polarity
Safety edgePhotocells
Initial start-upOperating modes and pause
Remote controlsAccessories
DiagnosticsResetting the control unit
Testing and maintenanceSpecifications
Help choosingPDF manual

DPRO500 use and supplied equipment

This is a standalone control unit with an enclosure for the TUB4000. The motor is ordered separately. Before replacement, compare the markings on the original control unit, the power supply, motor wiring, limit switches and safety devices. D-PRO ACTION, DPRO924 and the older A500 are different control units; do not use their wiring or procedures for the DPRO500.

The plug-in radio receiver, remote controls, photocells, safety edge and additional interfaces are selected according to the system configuration. The receiver is not built in. Replacing the control unit alone does not increase the permitted weight, length or number of operating cycles of the TUB4000 drive.

Installing and protecting the control unit enclosure

Mount the enclosure on a firm, stationary surface, outside any flood-prone area, with clear access to the buttons and service area. The enclosure dimensions are 310 × 210 × 160 mm. The enclosure can be mounted directly from the inside or using brackets. The optional NDA100 kit allows cables to be routed behind the enclosure, with a clearance of up to 2 cm from the wall.

Mounting options for the NICE DPRO500 control unit enclosure

Route the cables through suitable cable glands, preferably through the designated openings at the bottom. Seal the cable entries and prevent water from flowing in or condensation from conduits. Check the enclosure’s IP rating on its label and maintain it by using suitable cable glands and seals and by closing the cover properly.

DPRO500 power supply and motor connection

Wiring must be carried out by a qualified technician with the power supply disconnected. Before working on the unit, also protect against accidental switching on. The power supply must have suitable overcurrent protection and a disconnecting device for complete isolation. Connect the PE protective conductor to both the control unit enclosure and the motor, as shown in the wiring diagram.

ConnectionUse
TUB4000: 3~ 400 V ACConnect the mains supply to LINE L1, L2, L3 and PE; connect the three-phase motor to MOTOR U, V, W and PE. The TUB4000 has mechanical limit switches.
1~ 230 V ACOnly for a compatible single-phase motor and after correctly setting the power-supply jumper; connect the supply to L1, L3 and PE. This setting does not convert the TUB4000 into a 230 V motor.
Motor U/V/W in a single-phase applicationU = common conductor, V = opening, W = closing; applies only to a suitable single-phase motor.
Incorrect direction of travelAfter disconnecting the power supply, the technician swaps V and W. They then also check that the opening and closing limit switches are assigned correctly.

When using it with the TUB4000, also follow the TUB4000 drive wiring table. The power-supply cable size depends on its length and installation conditions; values for a short cable to a standalone unit cannot automatically be applied to a long run to the gate. If a 230 V beacon is to be switched from a 400/230 V supply via an additional board, a neutral conductor (N) must also be available.

Control unit terminals and accessory polarity

NICE DPRO500 – original board layout and connector labels

The auxiliary supply is 24 V DC: INPUT 8 / COM = positive (+), STOP 7 / GND = negative (−). The maximum combined current draw is 100 mA. Distinguish this supply from the 12 V output for the optical safety edge. Do not connect mains voltage to INPUT, ALT, SAFE or the safety-edge inputs.

Terminal / connectorConnection
INPUT 8 – COMMON+24 V DC; common command terminal and positive auxiliary supply.
INPUT 9 – OPENVolt-free NO contact between 8 and 9: opening. The contact has no +/− polarity.
INPUT 10 – CLOSEVolt-free NO contact between 8 and 10: closing. The contact has no +/− polarity.
INPUT 11 – ING1 / PHOTOFactory-configured as an NC safety input relative to 8. Other functions are configured via OVIEW; the input function must match the wiring.
ALTSeparate safety input for an NC contact. Do not confuse it with the three-pole STOP SAFETY EDGE connector.
SAFEMotor thermal protection when using mechanical limit switches. For the TUB4000, retain the actual protection wiring.
LIMIT SWITCH 1 / 2 / 3 / 41 common conductor; 2 opening; 3 closing pre-limit switch; 4 closing. Limit switches do not replace the gate’s mechanical stops.
STOP 5 / 6 / 75 = +12 V DC for OSE; 6 = S signal; 7 = GND, negative (−). Connect the 8.2 kΩ resistive safety edge between 6 and 7.
ENCODERNot used with the TUB4000’s mechanical limit switches. Do not apply the encoder procedure to this configuration.
OXI / SMPlug-in radio receiver with a compatible SM connector.
IBT4NInterface for OVIEW; connect and disconnect only when the power is off.
OUTNDA040 expansion board with two potential-free relay outputs.

STOP SAFETY EDGE

Supported types are an 8.2 kΩ resistive safety edge or an OSE optical safety edge. A change in the learned state triggers a stop followed by a short reverse movement. A photocell connected to PHOTO is not a substitute for a safety edge connected to STOP SAFETY EDGE.

Wiring an 8.2 kΩ resistive safety edge and an OSE optical safety edge to the DPRO500

Safety edge typeConnection
8.2 kΩ resistiveConnect the safety-edge output between 6 (S) and 7 (GND). Do not use terminal 5 to power this safety edge.
OSE optical5 = +12 V DC, brown conductor; 6 = S signal, green; 7 = GND/0 V (−), white. Also check the markings on the specific safety edge.
Additional safety devicesThe technician must configure the NO/NC/8.2 kΩ combination according to the wiring diagram in the manual. The single 8.2 kΩ end-of-line resistor belongs at the end of the relevant safety circuit; do not bridge the input.

When using hold-to-run control, the operator must have a clear view of the gate’s path, and the controls must not be freely accessible to unauthorised persons. Semi-automatic operation requires an active safety edge to limit forces; automatic operation also requires at least one pair of photocells. The technician must assess all crushing, shearing and drawing-in hazards.

Wiring NICE EPM photocells

For relay-type photocells NICE EPM use their power and safety terminals separately. The EPMB with BlueBUS is not a direct replacement for the relay-type EPM on this control unit.

NICE EPM photocells – TX/RX power supply and COM/NC contact

EPMDPRO500 in PHOTO mode
TX and RX: 1 = +, 2 = −1 → INPUT 8 / +24 V DC; 2 → STOP 7 / GND (−). One EPM pair draws a maximum of 55 mA; the total current drawn by all accessories must not exceed 100 mA.
RX 4 = COM, RX 5 = NC4 → INPUT 8; 5 → INPUT 11 / PHOTO. RX 3 = NO is not used for this safety wiring.
Voltage-free RX contactCOM/NC has no power-supply polarity; terminals 1/2 are a separate power supply.
Range15 m usable, 30 m maximum. For distances over 10 m, adjust the +10m jumper on the RX according to the EPM manual; fog, rain and dust can reduce the range by 50%.

After wiring, check that the system responds when the beam is interrupted, including if the photocell power supply fails. Do not choose the range based solely on the maximum catalogue figure. In the wiring shown, the EPM photocells are powered directly from terminals 8 and 7; do not use the photo-test or Stand-by wiring intended for a different control unit.

First start-up and position learning for TUB4000

Before switching on, check the PE connection, correct voltage, motor, mechanical stops, limit switches, closed safety circuit and all protective devices. After power-up, the green L2 OK LED should flash regularly at approximately 1 Hz, and the red SAFETY LED should remain lit. If the check fails, disconnect the power supply and correct the cause.

  1. Connect at least one suitable safety device to STOP SAFETY EDGE. Set DIP 1 to ON and all other DIP switches to OFF. The green LED flashes rapidly; the red LED is off.
  2. Hold STOP for approximately 3 seconds until the red LED stays lit, then release the button.
  3. Continue immediately with position learning: Set DIP 1 to OFF. With all other DIP switches set to OFF, hold Open and move the gate to the fully open limit switch. Then hold Close until the gate is fully closed.
  4. If the direction of travel is reversed, disconnect the power supply and correct the motor wires V/W. If the limit switches are assigned in reverse, the technician must correct their open/closed circuit; DIP 2 for the encoder is not a fix for the TUB4000 mechanical switches.
  5. After successful learning, select the required operating mode and carry out all functional and safety tests. If the edge type is changed or learning is interrupted, repeat the entire subsequent procedure.

Nine red flashes indicate a position-learning error. If the LED flashes three times, the technician should check the direction and assignment of the limit switches; after correcting the issue, clear the error using the STOP button and repeat the learning procedure. Do not attempt to operate the system with protective devices disabled.

DIP operating modes and automatic pause

DIP 1 / 2 / 3 / 4Mode
OFF / OFF / OFF / OFFHold-to-run: the gate moves while the button is held.
ON / OFF / OFF / OFFLearning the safety input and positions as described in the previous procedure.
OFF / OFF / OFF / ONIndustrial mode: semi-automatic opening, hold-to-run closing; requires positions to be learned.
OFF / OFF / ON / OFFSemi-automatic operation; requires positions to be learned.
OFF / OFF / ON / ONAutomatic operation with adjustable pause; requires positions to be learned and the appropriate safety devices.

Keep DIP 2 OFF when using the TUB4000 mechanical switches. It is used to change the encoder direction in the relevant supported application. If you set the modes via OVIEW, all DIP switches must be OFF.

  1. To learn the automatic pause, set DIP 3 and 4 to ON and open the gate fully.
  2. Once the gate reaches the open position, wait for the required time and then issue the close command. This interval is stored as the pause time.
  3. To change it, set DIP 3 and 4 to OFF and then back to ON; repeat the opening, waiting and closing sequence. Setting DIP 4 to OFF deletes the stored pause time.

Radio receiver and remote controls

The control unit has an SM connector for a plug-in receiver. A suitable option is NICE OXIBD; older setups may use SMXI, SMXIS, OXI or OXIT. Insert or remove the receiver only when the power supply is disconnected. Remote control select according to the specific receiver and its radio protocol. The procedure for storing or deleting a remote control is specific to the receiver, not a DPRO500 reset.

Receiver output in basic modeDPRO500 command
1Step by step
2Partial opening, factory-set to halfway along the travel; the setting can be adjusted.
3Open
4Close

The extended mode of a compatible receiver also enables additional commands, including Stop, lock and release of automatic operation. Check the receiver and its settings before use. Connect the OXIBD external antenna according to the manual directly to the receiver connector: connect the wire core to the antenna signal and the shield to the corresponding ground contact; these are not power-supply +/− terminals.

Expansion and signalling

OVIEW and IBT4N

Programming, diagnostics and changing the ING1 function are possible using OVIEW via IBT4N. Insert the interface with the power supply switched off. When setting modes via OVIEW, leave the DIP switches set to OFF. The changed input function must match the actual device wiring.

Flashing light via NDA040

For external relay outputs, the DPRO500 requires an optional NDA040 board in the OUT connector. It has two potential-free relay contacts, configurable via OVIEW. The contact does not provide a supply voltage; select the power supply and load according to the NDA040 wiring diagram and ratings.

For the TUB4000, the manual shows the wiring for a 230 V AC flashing light NICE ELAC via the NDA040 and the N wire. An AC flashing light has no +/− supply polarity. Do not connect it to the low-voltage INPUT or STOP terminals; a DC flashing light must not be connected to 230 V. The NDA040 relay load and safety inputs are separate circuits.

In the diagram shown, the NDA040 uses 4 = COM and 6 = NO: the L3 live wire goes to terminal 6; from terminal 4, it continues to one power terminal on the flashing light, while the other flashing-light terminal connects to N. Terminal 5 = NC is not used in this wiring. Set the output to the required flashing-light function via OVIEW. This switches 230 V AC, with no fixed +/− polarity; work must be carried out by a technician with the power supply disconnected.

TUB4000 and DPRO500 – connecting a warning light via the NDA040 accessory card

Status indicator on the cover

The terminal block on the button board provides a connection for an indicator 24 V DC, maximum 5 W: terminal 1 = minus (−), terminal 2 = plus (+). Maximum distance is 2 m. The output is not short-circuit protected and is separate from the 100 mA auxiliary power supply.

DPRO500 – status indicator terminals: 1 minus and 2 plus

When the safety circuit is open, the indicator goes out; during normal operation, it flashes 0.5 s on / 0.5 s off. For a serious fault, it repeats the red L1 diagnostic signal.

Two opposing sliding gate leaves

Each leaf must have its own motor, control unit, and limit switches. Connect the two units according to the separate diagram in the manual; use OVIEW to set Open to condominium mode. In this configuration, the safety edge, red STOP button, and thermal protection affect only their own leaf. A technician must design protection for the entire two-leaf assembly; this is not one motor output for two motors.

DPRO500 LED diagnostics

Count the flashes between pauses, and always distinguish between green L2 OK, red L1 WARNING and the separate SAFETY. The same number of flashes in a different color indicates a different condition. Do not jumper safety inputs when there is a fault.

Green L2Meaning and checks
Approximately 1×/sNormal operation after the initial signal.
2 flashesPhotocell activated: check for an obstruction, alignment, power supply, or missing authorization on PHOTO.
4 flashesSTOP or ALT activated; remove the cause.
6 flashesReduced operating maneuvers; check the operating load.
9 flashesAutomation blocked; after checking the cause, release it with the appropriate command.

Red L1Meaning and checks
2 flashesSafety test error: check the connected safety edge and repeat its recognition procedure.
3 flashesIncorrect direction / limit switch assignment. For mechanical switches, check the opening and closing circuits; after repair, press STOP and perform a new learning procedure.
4 flashesSafety limit switch overrun. Disconnect the power supply and, following the motor manual, move the gate manually to approximately halfway and secure it again; a technician must check the switches and positions and restore operation.
5 flashesInternal memory/parameter error. Switch off and on again; if the fault persists, have a qualified technician reset the unit and repeat the installation, or service the board.
6 flashesContactor, board, or motor connection fault; disconnect the power supply and arrange a professional inspection.
7 or 8 flashesCommunication or encoder fault with the relevant application; this procedure is not intended for TUB4000 mechanical limit switches.
9 flashesLimit position learning error; check the wiring and repeat the learning procedure. If the fault persists, perform a reset and configure the unit again.
10 flashesMovement time exceeded; factory setting is 60 s. Check for obstructions, verify movement, and check the timer setting in OVIEW; do not increase the time to mask a mechanical fault.

SAFETY on: the safety circuit is closed. SAFETY off: check ALT, STOP on the cover, thermal protection, and motor release. Rapid alternating L1/L2 flashes indicate a firmware update; four simultaneous flashes of both LEDs indicate that an update is pending. Updates are handled by service personnel.

When switched on, an empty memory causes both LEDs to flash rapidly for approximately 5 s. With learned positions, the green LED flashes rapidly for approximately 2 s; one slow red flash indicates a detected 8.2 kΩ safety edge, and two slow flashes indicate OSE. Interpret subsequent signals by color and flash count as described above.

Completely erasing DPRO500 memory

Resetting erases the control unit settings. Use it only after identifying the cause of the fault and securing the gate; it is not a routine way to clear a fault or erase transmitters in the separate receiver.

  1. Set DIP switches 1, 2, 3, and 4 to ON; the red and green LEDs will flash rapidly.
  2. Hold STOP for approximately 3 seconds, until both LEDs remain lit. Release STOP; after the reset, the LEDs will flash rapidly again.
  3. Set all four DIP switches back to OFF. Repeat the safety device and position learning procedures, configure the operating mode, and carry out safety tests.

Testing, operation, and maintenance

Before handover, repeatedly test Open, Close, and Stop, both limit switches, all photocells, safety edges, and the pedestrian gate interlock if it is built into the leaf. Check run-on, mechanical stops, and hazardous areas; where protection relies on force limitation, a technician must also perform any required measurements. Testing the control unit alone does not replace inspection of the complete gate.

Follow the maintenance schedule for the complete assembly. With the power supply disconnected, check the terminals, cables, cable glands, seals, moisture, fastenings, and protective conductors. Repeat functional and safety tests after any work. Replace a fuse only after removing the cause of the fault, and only with one of the same type and rating. Users must not work inside an open control cabinet.

Keep transmitters out of children's reach. Watch the gate while it is moving, and enter the passage only after it has fully opened and stopped. If the equipment malfunctions or behaves unusually, take it out of service and call for service.

Technical specifications of the control unit

ModelNICE DPRO500 with control box
Use with TUB4000NICE TUB4000 with mechanical limit switches
TUB4000 power supply3~ 400 V AC, depending on the motor and its power supply
Control unit power supply options3~ 400 V AC / 3~ 230 V AC or 1~ 230 V AC, ±10%, 50/60 Hz; specific application depends on the motor and wiring diagram
Maximum motor power2.2 kW; this is not the power consumption of the control unit itself or a new TUB4000 limit
Standby power consumptionLess than 5 W
Auxiliary power supply24 V DC, max. 100 mA total: INPUT 8 + / STOP 7 −
OSE safety edge5 +12 V DC / 6 signal / 7 GND −
Status indicator24 V DC / max. 5 W, 1 − / 2 +; cable length up to 2 m, not short-circuit protected
FusesF1: 500 mA, type F; F2, F3, F4: 6.3 A, type T
Control unit operating temperature−20 to +50 °C
Dimensions / weight310 × 210 × 160 mm / 2.5 kg
InstallationRigid, vibration-free surface; protect against water and condensation

Do not confuse the control unit specifications with the TUB4000 motor specifications. Before connecting, compare the labels on the supplied motor and control box, the power supply setting, and the exact board configuration.

Help choosing and replacing a control unit

Contact us with the motor and original control board identified, a photo of the terminals, the power supply, and a list of accessories. In the event of a fault, specify the LED colour, the number of flashes, and the situation in which the error occurs.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]