NICE SPIDER800W garage door opener kit for doors up to 11.4/12.6 m² with built-in Wi-Fi


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE SPIDER800W garage door opener kit for doors up to 11.4/12.6 m² with built-in Wi-Fi NICE SPIDER800W garage door opener kit for doors up to 11.4/12.6 m² with built-in Wi-Fi
NICE-SPIDER800W
within 3 days
€244.42 excluding VAT
€300.64 including VAT

 pcs
Weight
10 kg

Description of NICE SPIDER800W garage door opener kit for doors up to 11.4/12.6 m² with built-in Wi-Fi

NICE SPIDER 800W Drive Kit is designed for garage doors:

  • sectional garage doors up to a height of 2.6 m and an area of 11.4 m²,
  • overhanging up-and-over garage doors up to a height of 3 m and an area of 12.6 m²
The kit includes: NICE-SPIDER800W
NICE SPIDER800W Drive 1 × NICE SPIDER800W Drive  

NICE SPIDER800W electromechanical drive for sectional garage doors with an area of 11.4 m², or overhanging up-and-over garage doors with an area of 12.6 m². Motor with a built-in control unit and receiver, plus a built-in Wi-Fi module for app control.


 
NICE MYGO4 Remote Control 1 × NICE MYGO4 Remote Control NICE-MYGO4

Four-button remote control for operating an automatic gate remotely. Use it to control four devices or send one device four different commands.

Detail
NICE SR32B Belt Rail 1 × SR32B Belt Rail, 3.2 m NICE-SR32B

Pre-assembled belt rail SR32B with a length of 3.2 m. For sectional doors up to approximately 2.6 m; the limit for up-and-over doors varies depending on the construction. See the compatibility table.

Detail
NICE SPIDER800W Installation Manual 1 × NICE SPIDER800 Installation Manual  

Installation manual for a successful setup, with illustrated wiring diagrams and instructions for programming and pairing the remote controls.

Download
  1 × Mounting accessories  

Screws for attaching the drive to the rail, mounting brackets, emergency release cord, etc.

 

NICE SPIDER800W is a garage door kit with a belt rail SR32B 3.2 m and one MYGO4. It has a built-in MCU2 control unit, radio receiver and Wi-Fi. The assembly is powered from a 230 V AC.

The steel-cord-reinforced belt ensures quiet operation. The control unit learns the end positions, force and deceleration, and detects obstacles. In the event of a power outage, the door is released with a cord and operated manually.

Quick navigation
Accessories Features and comparison
Selection and limits Installation
Terminals and polarity Photo cells
Initial setup Settings
Remote controls Wi-Fi and app
Reset Diagnostics
Manual release Maintenance
Specifications PDF manual

Accessories and control

Choose safety devices based on the actual risks posed by the garage door. Obstacle detection in the opener does not replace photo cells, a safety edge or force measurement when commissioning the installation.

What Why Type
Control unit Opener setup, operation and servicing; the control board is built in.
Rail The opener moves a trolley with an arm and requires a suitable belt track.
Taller door Choose a track extension based on the door type, height, area and resistance.
Up-and-over door Up-and-over doors with counterweights require a suitable arm geometry.
  • SPA5; SPA5 is not used with spring-balanced up-and-over doors, depending on the installation type.
Photo cells Obstacle detection in the protected area. Choose the correct electrical interface.
Warning light Visible signalling of door movement, optionally with an external antenna.
Remote control The receiver is built in. The remote control must be stored in the receiver's memory.
Backup power supply Allows operation during a power outage when a battery is added.
Service settings Diagnostics and more detailed settings via BusT4.
Wi-Fi Control via phone and service configuration.

SPIDER800W kit contents

Compare the drive type, speed, control and limits of the specific door. Greater force or speed alone does not guarantee suitability. Safety accessories and backup power are selected separately.

Belt-drive kit with Wi-Fi
NICE SPIDER800W
NICE SPIDER800W
800 N; SR32B 3.2 m and MYGO4. Built-in Wi-Fi in the MCU2.

Which garage door is the opener suitable for?

With the standard rail SR32B the approximate dimensions depend on the type of garage door. The dimensions in the table are width × height. Suitability also depends on the door balance, friction, and available installation space.

Door type Approximate dimensions Condition
Sectional 4.4 × 2.6 m Approximately 11.4 m².
Non-protruding up-and-over 4.2 × 2.4 m SPA5; area 10.08 m².
Protruding up-and-over 4.2 × 3.0 m SPA5; area 12.6 m².
Spring-balanced up-and-over 4.2 × 3.0 m Depending on the installation, without SPA5; check the travel path and balance.

Maximum force 800 N and rated force 400 N indicate the motor's pulling force, not the door's weight in kilograms. With the opener disengaged, manually open and close the door along its full travel; the force required must not exceed 225 N. The opener must not be used as a substitute for repairing damaged springs or an incorrectly balanced door.

The SR32B rail is 3.2 m long, with a useful carriage travel of 2.8 m. The door height also depends on its construction and arm. For a taller door, you can add the SR08B 0.8 m extension with a longer belt; with a 4 m rail, the useful travel is 3.5 m. The extension alone does not confirm that the opener is suitable for a larger or heavier door. Send us the width, height, door type, and required travel via contact.

Cycle count and load

One cycle is a complete opening and closing. The table shows maximum values by door height; door resistance reduces them further. The overall limit of 50 cycles/day and a maximum of 4 minutes of continuous operation.

Door height Cycles/hour Consecutive
Up to 2 m 20 10
Over 2 to 2.5 m 15 7
Over 2.5 to 3 m 12 5
Over 3 to 3.5 m 10 4

At motor loads up to 250 N, the number of cycles is reduced by 25%; at 250–400 N, by 42%. These operating factors do not replace the manual test with the 225 N limit. Higher resistance requires checking the mechanism and the opener's suitability. The thermal limit may temporarily prevent further operation; allow the opener to cool down.

Installing the rail and opener

Install with the door closed and both the mains supply and backup battery disconnected. The door must move smoothly by hand and remain balanced in each position when disconnected from the carriage. Resolve any locks that would prevent automatic movement before installation. Springs and counterweights must be adjusted by a qualified technician.

  1. Check the clearance above the door, rail length, and the strength of the wall and ceiling. Leave access to the opener and release cord.
  2. For a two-piece rail, slide both sections into the connector as far as they will go. With the preassembled SR32B this joining step is not required. Check that the carriage moves freely and smoothly.
  3. Fit the motor head onto the rail and secure it with the supplied screws. The head may also be rotated 90° relative to the track axis, as shown in the installation drawing.
  4. Adjust the belt tension. An overtightened belt can damage the opener; a loose belt causes noise and unreliable movement. When extending the rail, use the correct longer belt.
  5. Fasten the front bracket to a sufficiently strong surface and suspend the rear section from the ceiling brackets. Align the track and tighten all fasteners.
  6. With the door closed, disengage the carriage, fit the door bracket in line with the rail, and connect the drawbar. A thin panel must be suitably reinforced; the installation must withstand the opener's force without deforming.
  7. Finish fitting the release cord. Manually move the door through its full travel, check the clearances, and re-engage the carriage before programming.

SPIDER800W installation space: A, B, C, D and distance E

In the orientation shown:

  • A = 40–400 mm
  • B = 0–400 mm
  • C = 3 158 mm
  • D = 395 mm.

For an up-and-over door, ensure E = 65–300 mm, i.e. the distance between the track and the highest point of the door's top edge as it moves. The dimensions apply to the installation arrangement shown.

Wiring and mains power

Use a grounded socket 230 V AC, 50/60 Hz, with a protective earth conductor and a means of safely disconnecting the power. Do not cut off or remove the supplied power cable or plug. Provide a suitable socket and supply cable. Route low-voltage wires separately from the mains wiring and secure them against pulling and contact with moving parts.

Connection Cable / maximum length
Supply to socket 3 × 1.5 mm²; 30 m. Over 30 m, use at least 3 × 2.5 mm² and provide grounding at the automation unit as required by the specific installation.
FLASH warning light 2 × 0.5 mm²; 20 m.
Antenna Separate RG58 coaxial cable; 10 m, recommended length under 5 m.
Push button / key switch 2 cables, 2 × 0.5 mm², or one 4 × 0.5 mm² cable; 50 m. The NO command contact is voltage-free.
BlueBUS photocells 2 × 0.7 mm²; 30 m; TX and RX wired in parallel, no polarity.
Relay photocells 4 × 0.5 mm²; 30 m; separate power supply and safety contact, wired as shown.
STOP safety edge 2 × 0.5 mm²; 20 m.

Mains power must not be connected to accessory inputs. The cable cross-section does not change the permitted current draw or the voltage of the relevant output.

Control board, terminals and polarity

The SPIDER800W has a built-in MCU2 control unit with BlueBUS and L1–L8 programming LEDs. This version also has built-in Wi-Fi.

MCU2 control unit in the NICE SPIDER800W operator

Original SPIDER800W wiring – photocells, commands, STOP, warning light and antenna

Terminal Function and connection
24 V / GND 24 V is positive (+), GND is negative (−). Auxiliary 24 V DC power supply, tolerance −30% / +50%, maximum total current 100 mA.
BlueBUS Two-wire power and communication for compatible devices; EPMB are connected in parallel. No polarity (+/−).
PHOTO Voltage-free normally closed (NC) contact between PHOTO and 24 V (+). Relay photocells require a separate 24 V (+) / GND (−) power supply.
SbS Voltage-free NO push button between SbS and 24 V (+); a brief contact closure sends a step-by-step command.
STOP / GND STOP safety input referenced to GND. NO, NC or 8.2 kΩ type is learned during setup. The contact itself has no polarity.
12 V OSE / STOP / GND Optical safety edge: 12 V OSE = positive (+), STOP = signal, GND = negative (−). 12 V DC power supply, maximum 15 mA. Connect only a compatible OSE safety edge, following its instructions.
FLASH / OGI Separate two-pole outputs, 24 V DC as standard, maximum 10 W per output. FLASH for the warning light, OGI for the open-position indicator. The function depends on the settings.
AERIAL Coaxial antenna input: center conductor and shielding as shown in the diagram; this is not an accessory power supply.

SPIDER800W auxiliary power supply: the specific positive and negative terminals

Push button, key switch or relay

Connect only a voltage-free NO contact, such as a push button or a control module relay. The contact connects SbS and 24 V (+). Do not apply the module's output voltage to the command input. If the module needs power, connect it separately to 24 V (+) and GND (−) and observe the 100 mA total limit.

Safety edge and STOP input

STOP halts movement and briefly reverses it. When a safety device is changed, you must relearn the devices. Wire multiple NO contacts in parallel and NC contacts in series. Wire 8.2 kΩ safety edges and combinations according to the specific diagram; a standard switch does not provide the same fault monitoring as a monitored safety edge.

Optical safety edge: 12 V OSE positive, STOP signal, GND negative

Photocell wiring

For simple two-wire wiring, choose NICE EPMB with BlueBUS. Connect both wires from TX and RX in parallel to the BlueBUS pair. This bus has no polarity; the 24 V (+) / GND (−) markings apply to other terminals.

  1. With the power disconnected, set the same jumper address on TX and RX of each pair. Each additional pair must have a different address.
  2. Secure and align TX with RX, then connect BlueBUS. Choose the function and installation height according to the area being protected.
  3. After wiring or changing addresses, perform device learning and a separate safety test.

Positioning safety photocells at a garage door

BlueBUS: jumper positions for the photocell addresses

Address Position and response
PHOTO / PHOTO II Indoor photocell at a height of 50 / 100 cm; stops and reverses movement during closing.
PHOTO 1 / PHOTO 1 II Outdoor photocell at a height of 50 / 100 cm; stops movement during both opening and closing, then resumes opening once the beam is clear.
PHOTO 2 / PHOTO 2 II Indoor protection active during opening; position as shown in the drawing.
PHOTO 3 Protection during opening and closing; select according to the actual risk and location.

Do not place pairs with the following addresses next to each other: PHOTO / PHOTO 2, PHOTO II / PHOTO 3, PHOTO 1 / PHOTO 2 II, to prevent them from interfering with each other. Photocells used as an open command do not replace a safety pair.

Relay photocells on PHOTO

For EPM without testing: on both TX and RX, 1 = positive, 2 = negative. Power them from the terminals 24 V (+) and GND (−). On RX, use 4 – COM and 5 – NC between 24 V (+) and PHOTO. Terminal 3 is NO and is not used for the PHOTO safety input. The total current draw from the auxiliary power supply must not exceed 100 mA.

Relay photocells with PHOTOTEST testing

For the tested wiring, power TX from the OGI, while RX remains on 24 V (+) / GND (−). With the board oriented exactly as shown in the diagram below, the upper OGI terminal is negative (−), and the lower one is positive (+). On the EPM, terminals 1 (+) and 2 (−) are used; RX terminals 4 – COM and 5 – NC go between 24 V (+) and PHOTO. OGI supplies 24 V DC, max. 10 W. Do not confuse these wires with the FLASH output.

Set level II/L5 to value LED L2 – PHOTOTEST and relearn the devices. Before movement, the control unit tests the photocells’ response; a failed test blocks the manoeuvre. This relay-based procedure is not used with BlueBUS EPMB.

Testing relay photocells on OGI: TX positive at the bottom, negative at the top, according to the board orientation

Flashing beacon, lighting and antenna

NICE ELDC connect it using its terminal block marked FLASH to the FLASH pair on the MCU2; the standard output is 24 V DC, max. 10 W. The output function must be set accordingly via programming. Do not connect a 230 V mains-powered beacon to these terminals.

For the FLASH pair on the beacon, follow the markings on the connected device. The polarity is not marked in this ELDC detail; do not apply the orientation of the auxiliary 24 V / GND terminal block to it. The AERIAL input on the ELDC is a separate antenna: connect the coaxial cable to the control unit’s antenna connector as shown. Do not confuse the antenna with the beacon power supply.

ELDC terminals: separate FLASH and AERIAL

The drive also has built-in garage lighting. The OGI output is also intended for external open-gate indication; if you change its function, check the OGI setting and load.

Initial start-up and learning

First complete the mechanical installation and wiring, secure the trolley, and clear the entire travel area. Check STOP, the photocells and the direction of travel. Learning the positions, learning the force and pairing the remote control are separate procedures.

Before switching on for the first time, position the secured gate approximately halfway along its travel. With a new, unconfigured control unit, 4 red BlueBUS flashes are a normal warning that configuration is missing. The beacon and interior light should be off at rest; in a standard installation, the direction selector is on the left.

1. BlueBUS and STOP learning

  1. Switch on the power. At first start-up, L1 and L2 flash; run device recognition even if no accessories are connected.
  2. Press and hold OPEN + STOP/SET for approximately 3 s. Release when L1 and L2 start flashing rapidly.
  3. Wait until the process is complete. STOP must be lit, and L1 and L2 must be off. On first installation, L3 and L4 start flashing: the positions need to be stored.

If you change the direction using the rotary switch on the board, set it with the power disconnected according to the drive layout, then relearn the devices. The direction change takes effect only after this learning procedure; do not change it by swapping the safety accessory wires.

2. Storing the open and closed positions

  1. Press and hold STOP/SET + CLOSE for approximately 3 s. L1 starts flashing.
  2. Use OPEN / CLOSE to set the desired fully open position. Press and hold STOP/SET for 3 s; L1 lights up and the open position A1 is stored. Release.
  3. While L8 is flashing, move the gate using OPEN / CLOSE to the fully closed position at floor level. Press and hold STOP/SET for 3 s; L8 lights up. Release; the programming LEDs go out.
  4. Send an SbS or OPEN command. The drive will complete a full automatic force-learning cycle.

The time limit for each step involving a movement command is 60 s; if this limit is exceeded, start setting the positions again. The control unit calculates intermediate positions, deceleration and partial opening; more detailed adjustments can be made via the service interface.

Force learning and the first movement test

Force learning runs an automatic opening and closing manoeuvre with increased force. Keep people and objects away from the gate during this process. The flashing interior light indicates that learning is in progress. After changing the positions, speed or direction, or reducing mechanical resistance, the force must be learned again.

If the process is interrupted by STOP, a photocell or a power failure, resolve the cause and resume learning with another SbS / OPEN / CLOSE command.

Pre-commissioning test

  • With the power disconnected and the trolley disengaged, manually open and close the gate; the force along the entire travel must not exceed 225 N. Then re-engage the trolley.
  • Open and close the gate again; it must reach the stored positions without binding or deforming the brackets.
  • Check deceleration at the end positions, belt slackening after the gate stops, manual release and re-engagement.
  • Interrupt each photocell at TX, at RX and in the middle of the beam; verify the correct safety response. Test all STOP devices.
  • Measure impact forces and verify the safety of the entire gate. Do not use increased force to mask poor mechanical installation. Repeat the measurement after changing the force setting.
  • Provide the user with instructions for operation, release and maintenance. Pass through only when the gate is fully open and stationary.

MCU2 programming

Use OPEN, STOP/SET, CLOSE and LEDs L1–L8 on the board. Program with the gate stationary. A short flash of the selected function LED indicates OFF; a longer flash indicates ON. After changing the force or sensitivity, check the gate’s safety again.

Level I – ON / OFF functions

  1. Press and hold STOP/SET until L1 starts flashing, then release.
  2. Use OPEN / CLOSE to move the flashing LED to the desired function.
  3. Press STOP/SET briefly to switch ON / OFF. Set another function if required.
  4. To save and exit, wait 20 s without pressing a button.

LED – function Meaning / factory setting
L1 – Automatic closing ON: closes after opening, following the pause set at level II/L1. OFF: waits for a command.
Factory setting: OFF.
L2 – Close after photocell ON: after the photocell beam is cleared, it uses a 5-second pause. With automatic closing enabled, the gate may stop opening when the beam is cleared; otherwise, it completes the opening cycle and closes after 5 seconds. STOP cancels this subsequent response.
Factory setting: OFF.
L3 – Always close ON: if power is restored and the gate is detected open, the warning light flashes for 5 seconds before the gate closes.
Factory setting: OFF.
L4 – Standby ON: after 1 minute of inactivity, part of the electronics switches off; BlueBUS signals slowly. Take the power requirements of connected devices into account.
Factory setting: OFF.
L5 – Protection against unauthorized opening ON: if forced opening is detected, the gate closes. App notifications require a compatible interface and configuration.
Factory setting: OFF.
L6 – Pre-flashing ON: the warning light flashes for 3 seconds before movement begins.
Factory setting: OFF.
L7 – Disable internal radio ON: the internal receiver is disabled, for example when using an external OXI/OXIBD. OFF: the built-in radio receiver is active.
Factory setting: OFF.
L8 – Light / heavy gate ON: preset for a light gate. OFF: preset for a heavy gate. Changes the group of force, sensitivity and speed values; force learning is then required.
Factory setting: OFF.

Level II – adjustable values

  1. Press and hold STOP/SET until L1 starts flashing, then release.
  2. Use OPEN / CLOSE to select the parameter input LED..
  3. Press and hold STOP/SET. After approximately 3 s its current value LED lights up. Continue holding STOP/SET and use OPEN / CLOSE to select a different value LED.
  4. Release STOP/SET. Set another parameter or wait 20 s without pressing any buttons to save and exit.

The factory-set value LED is shown in bold. The light/heavy gate preset or settings made via the service interface may change some values; the current indication on the control board takes precedence.

Input LED – name and description Setting LED – value
L1 – Pause
Automatic closing time; active when I/L1 is ON.
L1 – 5 s
L2 – 15 s
L3 – 30 s
L4 – 45 s
L5 – 60 s
L6 – 80 s
L7 – 120 s
L8 – 180 s
L2 – Step-by-step command
Sequence for the step-by-step input and the first radio command. Modes L4, L5, L7 and L8 also change the OPEN / CLOSE commands.
L1 – open – stop – close – stop
L2 – open – stop – close – open
L3 – open – close – open – close
L4 – shared input
L5 – shared input 2; holding for more than 2 s = STOP
L6 – SbS 2; holding for more than 2 s = partial opening
L7 – movement only while the command is held
L8 – semi-automatic opening, closing while the command is held
L3 – Speed
Percentage of maximum speed. Force learning must be repeated after changing this setting.
L1 – 30%
L2 – 44%
L3 – 58%
L4 – 72%
L5 – 86%
L6 – 100%
L7 – opening V4 (72%), closing V2 (44%)
L8 – opening V6 (100%), closing V4 (72%)
L4 – FLASH (OUT1)
The output function must be suitable for the load. Output: 24 V DC, max. 10 W.
L1 – gate-open indicator
L2 – active when the gate is closed
L3 – active when the gate is open
L4 – warning light
L5 – electric strike
L6 – electric lock
L7 – magnetic lock
L8 – maintenance indication
L5 – OGI (OUT2)
Second output: 24 V DC, max. 10 W; phototest requires correct TX wiring and a new learning cycle.
L1 – OGI open-gate indicator
L2 – PHOTOTEST
L3 – gate status
L4 – garage lighting
L5 – radio channel 1
L6 – radio channel 2
L7 – radio channel 3
L8 – radio channel 4
L6 – Motor force
Adjustment values in %: opening / closing. This is not the force measured on impact.
L1 – 60 / 30%
L2 – 60 / 40%
L3 – 70 / 40%
L4 – 70 / 50%
L5 – 80 / 50%
L6 – 80 / 60%
L7 – 90 / 70%
L8 – 90 / 80%
L7 – Obstacle sensitivity
Sensitivity levels for opening / closing; these are not newtons.
L1 – disabled
L2 – 10 / 20
L3 – 20 / 30
L4 – 30 / 40
L5 – 40 / 50
L6 – 50 / 60
L7 – 60 / 70
L8 – 70 / 80
L8 – Mechanical relief
A brief reversal releases tension after the gate reaches the closed position. Force learning is required after changing this setting.
L1 – no relief
L2 – minimum
L3 – intermediate level 3
L4 – intermediate level 4
L5 – intermediate level 5
L6 – intermediate level 6
L7 – intermediate level 7
L8 – maximum

If L1 and L8 flash simultaneously during adjustment, the current value is outside the range available on the control board, for example after being set via the service interface. Check this setting or use the OPEN / CLOSE buttons to select a suitable value from the available options.

Remote controls and pairing

The receiver is built in. MYGO4 from the kit must be stored in memory. The MCU2 uses O-Code and BD and has memory for 100 remote controls in Mode 1; for an additional remote control, check the encoding, not just the 433.92 MHz frequency.

Mode 1 – all buttons

  1. Hold RADIO until the green R LED lights up, then release it.
  2. Within 10 s hold any button on a one-way remote control. Release it at the first of the three green R flashes.
  3. With a two-way remote control, press and immediately release the button; storage is confirmed by three green R flashes and a short vibration from a compatible remote control.

Button in Mode 1 Command
1 Step-by-step (SbS) command
2 Partial opening
3 Open
4 Close

Mode 2 – one button

Press and release RADIO n times, according to the command number. The R LED will repeat the number. Within 10 s, store the selected remote-control button as described above; repeat the process for each additional button.

Number of RADIO presses Command
1 SbS
2 Partial opening 1
3 Open
4 Close
5 STOP
6 SbS for common entrance
7 High-priority SbS
8 Partial opening 2
9 Partial opening 3
10 Open and disable automatic operation
11 Close and disable automatic operation
12 Disable automatic operation
13 Enable automatic operation
14 Lighting – timer
15 Lighting – switch on/off

With the MCU2, a high-priority button can also operate the automation when it is disabled. For normal operation, use SbS; select the lock commands only when you need this function.

Adding a remote control using an existing one

Carry out the procedure within range of the drive and only when learning is enabled. Applies to one-way remote controls.

  1. On the new remote control, hold down the required button for 7 s and release it.
  2. On the original remote control, slowly press and release the stored button three times.
  3. On the new remote control, press and release once the same button used in the first step.

Erasing the radio memory

Erases all stored remote controls. Keep holding RADIO even after the R LED lights up and then goes out. When it flashes again, release the button exactly on the fifth flash. Five rapid flashes confirm success. Erasing the radio memory is a separate procedure from resetting the control unit.

For two-way remote controls, follow their instructions to also remove the stored pairing on the transmitter side.

Erasing one remote control or button

  1. Hold RADIO until the green R LED lights up and then goes out; release RADIO at that point.
  2. One-way remote control: hold down its stored button. Release it at the first of the five rapid green R flashes.
  3. Two-way remote control: briefly press and release its stored button. Erasure is confirmed by five rapid green R flashes.

In Mode 1 the entire remote control is erased. In Mode 2 only the button used to transmit is erased; erase any other buttons separately.

Disabling remote learning

  1. Disconnect both the mains power and backup supply, then wait 10 s. Hold RADIO and restore power.
  2. After the stored remote controls are signalled, release RADIO immediately after the second short orange R flash.
  3. Within 5 s, use short presses of RADIO to select a setting: R off = no restriction; red = prevent adding a new remote control using one already stored while within range of the drive; green = prevent adding via an authorisation code; orange = both restrictions.
  4. Within 5 s, press a stored button on an already paired transmitter to save the selected setting.

This setting blocks selected methods of adding remote controls remotely. Pairing using the RADIO button on the control board is a separate procedure; switching off the built-in radio disables the entire built-in receiver.

Wi-Fi on the SPIDER800W and the MyNice app

Wi-Fi is built into the MCU2; you do not need to purchase a BiDi-WiFi separately for basic connectivity with this kit. The module uses a 2.4 GHz (802.11 b/g/n). The user app MyNice is used for control, MyNice Pro for setup and servicing. Download the app from your phone’s app store.

  1. Once the gate is installed and has been safely tested, switch on the drive and check the W1 power LED.
  2. In the app, select the option to add a Wi-Fi interface or accessory and follow the setup wizard. The phone and drive must have a suitable connection during configuration.
  3. Select your home 2.4 GHz network and enter its credentials. Remote control requires a working internet connection and the Nice service.
  4. Test the gate status and operation. A command from the phone can set the gate in motion; safety devices must remain operational.

MCU2 built-in Wi-Fi: P1/P2 buttons and W1/W2 LEDs

W2 / W1 Meaning and procedure
Green / green Normal operation; the phone is connected.
Green / 8 rapid green flashes Temporary device identification requested by the app.
Green flashing / green The module is waiting for network configuration; continue in the app.
Orange / green Normal operation; the phone is not currently connected.
Orange flashing / green Briefly: network setup. If the status persists, check the network and configuration.
Off / green The 30-minute window has expired for the unconfigured module. Disconnect and restore the power, then repeat the configuration.
Off / orange flashing Update takes approximately 1 minute; please wait. If it fails, the module will restart after approximately 5 minutes.
Red flashing / off The module reset button was pressed during power-up.
Red / green The module failed to connect to the home network or the Nice service; check the network, password, and internet access.

Wi-Fi module reset only

Press and hold P1 for 10 s restores the Wi-Fi module to factory settings; then add it again in the app. P2 is not used with this version. This operation is different from the control unit reset and deleting the transmitters.

Control unit reset

Resetting clears the control unit's custom settings. Press and hold OPEN + CLOSE for approximately 3 s, until L1–L8 light up; release. Successful reset is confirmed by their rapid flashing for 3 s. After resetting, repeat device learning, position learning and test the gate. This procedure does not delete the radio codes in either the built-in or external receiver.

Troubleshooting

FLASH indicates errors by the number of short flashes. The sequence repeats after a 1 s pause; count one sequence.

Indicator Cause and next step
1 flash Closing / position
The floor was not detected while closing. Set the closed position.
2 flashes Photocells
Remove the obstruction, check the alignment and photocell wiring. Activation when an obstruction is detected is expected.
3 flashes Force limit
Check manual movement, springs, obstructions, and friction. Do not automatically increase the force; check the mechanism and safety.
4 flashes STOP
Check the STOP safety device and any control unit lockout.
5 flashes Parameter memory
Wait at least 30 s, then try a command. If the error persists, arrange for servicing.
6 flashes Operation limit
Wait a few minutes for it to cool down. Check the operating load and gate resistance.
7 flashes Internal electrical circuit
Disconnect all power supplies for a few seconds. If the error persists, have a service technician check the board and motor wiring.
8 flashes Continuous command
Remove the continuously active command, such as a held button or energized relay; check SbS.
9 flashes Automation stopped
A command was issued to stop the automation; resume operation with the appropriate control command.

LED / indication Meaning and check
BlueBUS – 2 green flashes/s Normal operation. Two rapid green flashes indicate an input change.
BlueBUS – rapid, longer red sequences Bus short circuit: with the power disconnected, check the cables. Once the fault is cleared, normal indication resumes after approximately 10 s.
STOP off STOP active; check the safety wiring.
PHOTO off PHOTO relay input activated.
SbS lit Command present; if the button is not pressed, check the cables and relay.
L1 + L2 flashing Required: device learning.
L3 + L4 flashing Required: position learning.
Red light during movement The set maintenance interval has elapsed; carry out an inspection.
L1 through L8 light up in sequence Firmware update: please wait; do not disconnect the power supply.

If a safety device fails, do not operate the automation system normally. Safely disengage and arrange for a repair. Replace the fuse only with one of the same type and rating; do not repair it by bridging it.

PS124 backup battery

PS124 fits into the designated compartment in the drive unit and connects to the specified connector as shown in the installation PDF. Connect it only after completing the mechanical installation, wiring, and programming. The battery remains energized even after the mains supply is disconnected: before working, disconnect the mains supply and PS124. The number of movements during a power outage depends on the battery condition, temperature, and gate resistance.

Disengaging and manual operation

Disengage the drive only when the gate is stationary. If a spring is faulty or the gate is unbalanced, a released gate may drop uncontrollably; secure it and call a technician. If the garage can only be accessed through this gate, arrange in advance for a means of disengaging it from outside that is suitable for the specific gate.

  1. Pull release cord A. The trolley will disengage, and you can safely move the gate by hand.
  2. To re-engage it, pull cord A again as shown in the second illustration.
  3. Move the gate by hand until the lower and upper parts of the trolley align and engage. Check that it is engaged before issuing an electrical command.

Disengaging and re-engaging the SPIDER800W trolley

Maintenance and safe operation

Schedule an inspection at least every 6 months or after 3,000 operating cycles, whichever comes first. Disconnect all power sources before maintenance. Check the rail, belt, trolley, brackets, corrosion, springs, and gate balance; replace worn parts. After the inspection, repeat the test of the safety devices and forces.

Keep remote controls out of reach of children. Do not enter the gate's operating area while it is moving. If there is unusual noise, jerking, or a deterioration in balance, stop operating the system and contact service. Dispose of electronic equipment and batteries at an appropriate collection point, not in mixed waste.

SPIDER800W technical specifications

Parameter Value
Application Electromechanical garage door operator for residential use.
Control unit Built-in MCU2, BlueBUS, and LEDs L1–L8.
Mains power supply 230 V AC ±10%, 50/60 Hz; protective earth conductor.
Maximum / rated force 800 / 400 N.
Rated / maximum power input 180 / 280 W.
Maximum speed 0.20 m/s; actual operation depends on the settings and load.
Cycles/day 50; also observe the other operating limits.
Continuous operation Maximum 4 minutes.
Protection rating / temperature IP40; −20 to +55 °C.
Head dimensions 225 × 395 × 105 mm; see drawing for installation details.
Motor weight 4.9 kg; this is not the weight of the complete kit.
Auxiliary accessories 24 V DC, tolerance −30% / +50%, total max. 100 mA; polarity and terminals.
Backup PS124 – optional.
Lighting Built-in LEDs.

Dimensions of the NICE SPIDER800W motor head

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE SPIDER800W garage door opener kit for doors up to 11.4/12.6 m² with built-in Wi-Fi

Product: NICE SPIDER800W garage door opener kit for doors up to 11.4/12.6 m² with built-in Wi-Fi
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.