NICE Soon SO2000 – drive for a sectional garage door with a maximum area of 20 m² and a maximum height of 5 m
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€433.87 including VAT
| Weight |
|---|
| 11 kg |
Description of NICE Soon SO2000 – drive for a sectional garage door with a maximum area of 20 m² and a maximum height of 5 m
NICE SOON SO2000 is a shaft drive for sectional garage doors up to 20 m² and an approximate height of 5 m. It has a 24 V DC motor, a built-in control unit NICE SOA2R30 with BlueBUS, a magnetic encoder and integrated LED lighting. The entire drive is powered from a 230 V AC.
The drive is non-reversible and can be disengaged using the supplied release cords in the event of a power failure. The encoder tracks the position; the open and closed positions must be learned. Mechanical stops and correct gate balancing are still required.
| Quick navigation | |
|---|---|
| Drive selection | Accessories |
| Package contents | Installation |
| Manual release | Wiring |
| Initial setup | Settings |
| Remote controls | Diagnostics |
| Reset | Maintenance |
| Specifications | PDF manual |
Accessories and control unit selection
The SOA2R30 control unit is built into the SOON SO2000. A separate DPRO924 is not added to this version. The wiring and settings below apply to the SOA2R30; if the control board has a different designation, follow the instructions for the installed unit. On the SOA2R30, Standby mode is enabled by default.
| What | Why | Type |
|---|---|---|
| Control unit | Controls the drive and sets its functions. | |
| Photocells | Passageway protection; two-wire polarity-free wiring. | |
| Warning light | Signals movement; FLASH setting. | |
| Radio receiver and remote control | Transmitter control; SM socket and pairing. | |
| Backup battery | Operation during a mains power failure; installed in the drive. | |
| Direct shaft coupling | Adapts to diameters of 31.75 / 35 / 40 mm. | |
| Chain drive | Offset installation; select the drive ratio and brackets. |
When to choose the SOON SO2000
This drive is suitable for indoor use with a balanced sectional door when you want integrated motor controls and a drive that does not require a ceiling rail. IP40 indicates protection for indoor installation. Guide resistance, springs, wind and frost affect suitability more than the area alone.
| Requirement | Value |
|---|---|
| Sectional door area | Up to 20 m². |
| Approximate dimensions | Height up to 5 m, width up to 4 m; check the specific door. |
| Torque | Maximum 50 Nm; rated 30 Nm. |
| Output speed | Maximum 30 rpm; rated 18 rpm. The door speed also depends on the drum diameter and drive ratio. |
Number of cycles depending on movement resistance
One cycle is a complete opening and closing. Intensive operation is subject to the following conditions:
| Manual operating force | Cycles/h | Consecutively |
|---|---|---|
| Up to 120 N | 20 | 35 |
| 120–180 N | 18 | 33 |
| 180–220 N | 15 | 30 |
At the range boundary, use the lower limit. The thermal limiter monitors the load and duration of movement; after it trips, allow the drive to cool down. The figure of 15 cycles/h in the technical specifications applies to a 3 m door at the rated torque. It is not a guarantee for every configuration.
What’s included with the drive

SOON: motor, cable release, bracket and mounting fasteners
| Part | Purpose |
|---|---|
| Motor with control unit | SOON SO2000 with SOA2R30 control board and lighting. |
| Release | Cable release; 4 m cables and a guide component for horizontal installation. |
| Fastening | Bracket, M8 × 130 bolt, M8 self-locking nut, D8 washer, 3 self-tapping screws and 2 drive keys. |
| Installation manual | Drive instructions. Wall anchors, CRA gear, photocells, radio receiver and battery are selected according to the configuration. |
Installing the drive
Disconnect the mains power and backup battery before carrying out any work. The door must be mechanically safe and correctly balanced, with functional guides and stops. For a sectional door, also check the springs and lifting cables. The drive will not fix a door that is difficult to move.
Direct shaft mounting
The NICE SOON SO2000 drive is mounted directly on the sectional door shaft Ø 25.4 mm. For shafts Ø 31.75 / 35 / 40 mm, use NICE CRA9. The mounting bracket is included; choose wall anchors to suit the substrate. The Ø 25.5 mm opening in the motor does not indicate a different recommended shaft diameter.
- Install the SOON with the door closed. Slide the drive onto the shaft and insert the supplied drive key.
- Secure the bracket to the drive using the supplied bolt, nut and washer. Securely anchor the bracket to a load-bearing wall.
- For horizontal installation, fit the supplied cable-release guide with three screws and route the cables as shown. The cables must remain accessible.
- Before programming, check the encoder position and ensure the travel path is clear. The usable encoder range is 5–95%; the end positions must fall within this range.

SOON: sliding the drive onto the shaft and inserting the drive key

SOON: anchoring the supplied bracket to the wall

SOON in horizontal position: routing the release cables
Offset mounting via chain
When there is not enough space for direct mounting, use a shaft with an 18-tooth sprocket NICE CRA1 in the drive and a sprocket on the door shaft. The transmission connects them with a 1/2″ × 5/16″ chain NICE CRA3 (1 m) or NICE CRA4 (5 m), with a connector NICE CRA2. Brackets for off-axis mounting include NICE CRA8.
| Transmission | Components and result |
|---|---|
| 1 : 1 | NICE CRA1 + NICE CRA7 (18 / 18 teeth). No speed reduction. |
| 1 : 2 | NICE CRA1 + NICE CRA6 (18 / 36 teeth). The door shaft rotates more slowly; the transmitted torque and door construction must be assessed. |
The sprockets must be aligned, the chain correctly tensioned and protected against trapping hands or clothing. Changing the gear ratio does not automatically change the permitted door area. The dimensions, balance, travel and overall configuration must be assessed together.
Chain setup for a suspended sliding door
The SOON wiring and programming described on this page apply to a sectional door. A chain setup for a suspended door requires a separate assessment to determine a suitable drive.
For a suspended door, the loop comprises a shaft with a sprocket NICE CRA1, a tensioner with an idler sprocket NICE CRA5, a chain NICE CRA4 and connectors NICE CRA2. Attach the door leaf to the upper or lower chain run, depending on the direction of travel. For two opposing door leaves, attach one to the upper run and the other to the lower run.
This is a custom-designed chain setup. The sectional door area limit does not determine the permitted weight or length of a suspended door leaf. Check the travel resistance, force transmission, travel path, mechanical stops and protection of pinch points.
Manual release during a power outage
Release only when the door is stationary and correctly balanced. Never release it if the springs are damaged or if the door could fall.
- Pull the release control/cable A as shown. The drive disengages.
- Move the door by hand without forcing it.
- To resume motorized operation, pull the release control/cable B. Check that it is locked again.

SOON: A releases the transmission; B locks it again
SOA2R30 wiring
Before opening the cover, disconnect the 230 V mains supply and the backup battery. The control unit is built directly into the drive. Route the cables through the cable glands, keep the mains wiring separate from the signal wiring, and connect the protective earth.

SOA2R30: FLASH, BlueBUS, STOP, SbS, OPEN, CLOSE, antenna, SM, IBT4N and STB
Wiring and maximum cable lengths
| Connection | Cable / length |
|---|---|
| 230 V AC mains | 3 × 1.5 mm² / 30 m; for longer runs, use 3 × 2.5 mm² and connect the earth near the drive. |
| FLASH | 2 × 1 mm² / 20 m. |
| BlueBUS | 2 × 0.5 mm² / 30 m; for runs between 30–50 m, use 2 × 1 mm². |
| Key switch | Two 2 × 0.5 mm² cables / 50 m, or one 4 × 0.5 mm² cable. |
| Safety edge | 2 × 0.5 mm² / 20 m; with OSE, follow its own wiring system. |
| Antenna | RG58 / 20 m maximum; less than 5 m recommended. |
Terminals and auxiliary power supply
| Terminal | Connection |
|---|---|
| BlueBUS | Two-wire power supply and communication for compatible devices; no polarity, up to 12 BlueBUS devices. This is not a general-purpose 24 V output. |
| STOP | Safety device: NO, NC, 8.2 kΩ or supported optical edge; wiring requirements. |
| SbS / OPEN / CLOSE | Volt-free NO contacts: step-by-step / open / close. Do not apply external voltage; the contact itself has no polarity. |
| Auxiliary + / − | + right-hand terminal of the SbS pair, − left-hand terminal of the STOP pair, viewed in the orientation shown in the detail below. With the control unit active: 24 V DC, −30% / +50%, 100 mA maximum total. In Standby mode: 21 V DC ±10%, 2 W available power. Do not confuse these with the complete pairs of command inputs. |
| SM / IBT4N | SM for the plug-in receiver; IBT4N for the BusT4 interface and programmer. |
| STB | Connector for the Standby board. |
| FLASH | The output varies according to the selected mode; voltage and limits below. |

SOA2R10 auxiliary power supply: terminals marked SbS (+) and STOP (−)
BlueBUS photocells
NICE EPMB connect in parallel with two wires to BlueBUS. Wire order does not matter. Set the same jumpers on the TX and RX of each pair; each pair must have a different address. After adding or removing a device, repeat device learning.

SOON: positions and functions of the individual photocell pairs
| Address | Response |
|---|---|
| FOTO / FOTO II | Outer pairs at heights of 50 / 100 cm: stop and reverse the movement when closing. |
| FOTO 1 / FOTO 1 II | Inner pairs at heights of 50 / 100 cm: protection during both opening and closing. |
| FOTO 2 / FOTO 2 II | Outer / inner pair active during opening. |
| FOTO 3 | Pair protecting the entire automation area. |
| FA1 / FA2 | Opening command, not a substitute for a safety pair; on supported TX and RX units, remove jumper A. |
Set the jumper positions according to the EPMB photocell instructions and the required function. Classic relay-type EPM units cannot be connected directly to BlueBUS.
STOP and safety edge
Connect multiple NO contacts in parallel and multiple NC contacts in series. The resistive edge must present 8.2 kΩ to the control unit in the idle state; when daisy-chaining, use the terminating resistor only at the end. The wiring for an optical OSE edge depends on its specific interface. Do not supply these devices from the SbS/STOP auxiliary +/− terminals without the correct safety-edge wiring diagram. After each change, perform device learning and test the STOP function.
Flashing light and FLASH modes
NICE ELDC is a low-voltage flashing light for 12–36 V. On the SOA2R30, FLASH must be set to II/L4 → value L4 “flashing light” (default value). This mode is intended for a 12 V warning light rated up to 21 W; do not choose an accessory based on the drive’s 230 V mains input. After connecting, check that the light flashes visibly while the gate is moving.
| FLASH mode | Voltage and load |
|---|---|
| Flashing light | 12 V warning light, 21 W maximum; flashes on for 0.5 s / off for 0.5 s while the gate is moving. |
| Gate-open indicator | 24 V, 5 W maximum. |
| Electromagnet, latch or lock | 24 V, 10 W maximum; coil only, without built-in electronics. Select the corresponding II/L4 function. |
Neither the FLASH pair nor the antenna connector is marked as auxiliary +/− terminals. Do not infer wire order from the SbS/STOP detail; for a polarized coil, follow the markings on the device and the installed board.
PSS124 and PS124 backup batteries, programming
For the SOA2R30 with Standby mode enabled, use NICE PSS124. The older NICE PS124 can be used only with Standby mode disabled. Install the battery in the drive and connect it to the designated connector only after installation and programming are complete. It is not included with the motor on its own. The number of operations during a power failure depends on the gate, power consumption and battery condition; approximately 10 operations is only an estimate. Standby is activated only after the backup battery has finished charging.

SOA2R30: fitting the backup battery and connecting it to the control unit
The Oview programmer uses the IBT4N/BusT4 interface. When using the compatible Solemyo solar power supply, the operator must not be powered from the mains at the same time. Do not substitute backup or solar accessories from a different generation based on a similar connector.
Initial start-up and position learning
Before switching on for a test, move the gate to approximately halfway along its travel. After power-up, BlueBUS should flash once per second; the beacon and courtesy light should be off while idle. If the check does not pass, disconnect the power and check the wiring.
1. BlueBUS and STOP learning
- Press and hold OPEN ▲ + STOP ■ for approximately 3 s.
- Release when L1 and L2 flash rapidly.
- Wait for completion: the STOP LED is on and L1/L2 go out. L3/L4 may start flashing to prompt position learning.
Learning is required even when no accessories are connected.
2. Quick learning of opening and closing positions
- Press and hold STOP ■ + CLOSE ▼ for 3 s; L1 flashes.
- Use ▲/▼ to set the required full-open position. Press and hold STOP for 5 s to save A1 and skip the optional positions.
- When L8 flashes, set the closed position A0. Confirm by holding STOP for 2 s.
- When the LEDs go out, the courtesy light flashes. Continue with the mandatory force learning procedure.
Full learning and custom slowdown positions
Start in the same way: hold STOP + CLOSE for 3 s. At each point, move the gate with ▲/▼ and confirm the position by holding STOP for 2 s. Skip an optional position by pressing STOP twice quickly.
| LED / position | Meaning |
|---|---|
| L1 – A1 | Fully open position; mandatory. |
| L2 – RA1 | Start of slowdown during opening; optional. |
| L4 – RINT | Intermediate slowdown position during closing; slows down approximately 50 cm before the point, then returns to the set speed. |
| L5 – AP | Partial opening position; optional. |
| L7 – RA0 | Start of slowdown during closing; optional. |
| L8 – A0 | Closed position; mandatory. |
3. Mandatory automatic force learning
Send an SbS or OPEN movement command. The control unit performs 3 complete cycles. Do not interrupt them, and keep the entire gate area under observation. If interrupted, restart the procedure using SbS, OPEN or CLOSE. Changing the positions, speed or direction of rotation triggers new force learning. Completion does not replace testing the safety devices and impact forces.
Programming the SOA2R30

SOA2R30: OPEN ▲, STOP ■, CLOSE ▼ and programming LEDs L1–L8
When idle, ▲ opens, ▼ closes and ■ stops. While the gate is moving, all three buttons stop the motor. During setup, each parameter has its own selection LED; the value LED in Level II indicates a separate option.
Level I – switching functions on and off
- Press and hold STOP for about 3 s until L1 starts flashing, then release.
- Use ▲/▼ to select the function LED.
- Press STOP briefly: a short flash means OFF; a long flash means ON.
- If no button is pressed for 10 s, programming ends and the changes are saved.
Level I functions are factory-set to OFF, except for L4 – Standby, which is factory-set to ON on the SOA2R30 control unit.
| LED – function | Operation and factory setting |
|---|---|
| L1 – Automatic closing | ON: closes after the pause set in II/L1. OFF: automatic closing disabled. Factory setting: OFF. |
| L2 – Close after photocell | ON: 5 s pause after the photocell is cleared. With automatic closing OFF, the gate first completes opening; with it ON, clearing the photocell may stop opening and start a 5 s pause. A STOP command cancels the subsequent closing movement. Factory setting: OFF. |
| L3 – Always close | ON: when power returns and the gate is detected open, it closes after a 3 s pre-flash. OFF: this return-to-power command is not used. Factory setting: OFF. |
| L4 – Standby | ON: When powered from the mains, 5 minutes after a manoeuvre ends the control unit switches off the BlueBUS output and all other indicator lights. The BlueBUS indicator flashes more slowly. Full operation resumes when a command is received. If the positions have not been learned, the mode activates 10 minutes after power-up. Factory setting: ON. PSS124: Standby may remain enabled. If enabled, it activates only after the battery has finished charging. PS124: When using this battery, Standby must be disabled. |
| L5 – Long reversal | This function applies only to STOP activations and obstacle detections configured for short reversal. ON: instead of a short reversal, the gate reverses fully to the corresponding end position. OFF: the programmed short reversal is retained. Factory setting: OFF. |
| L6 – Pre-flashing | ON: the beacon flashes for 3 s before movement. OFF: it switches on when movement starts. Factory setting: OFF. |
| L7 – Sensitivity | ON: increases obstacle detection sensitivity. Requires checking the forces and safety responses. Factory setting: OFF. |
| L8 – Gate type | ON: heavy gate. OFF: light gate. This setting does not change the permitted area or mechanical requirements. Factory setting: OFF. |
Level II – adjustable parameters
- Press and hold STOP for about 3 s until L1 flashes, then release.
- Use ▲/▼ to select the parameter LED.
- Press and hold STOP; after about 3 s, the value LED lights up.
- Keep holding STOP, change the value with ▲/▼, then release STOP.
- If no action is taken for 10 s, the setting is saved. Bold values are the factory defaults.
| Input LED – name and description | LED settings – value |
|---|---|
| L1 – Pause time Applies when I/L1 is ON. | L1 – 10 s L2 – 20 s L3 – 40 s L4 – 60 s L5 – 80 s L6 – 120 s L7 – 160 s L8 – 200 s |
| L2 – Step-by-step SbS Sequence for the SbS input and step-by-step command from the radio remote. | L1 – Open – stop – close – stop L2 – Open – stop – close – open L3 – Open – close – open – close L4 – Condominium L5 – Condominium 2; command longer than 2 s = STOP L6 – Step-by-step 2; command longer than 2 s = partial opening L7 – Hold-to-run L8 – Semi-automatic opening, hold-to-run closing |
| L3 – Motor speed Repeat force learning after changing this setting. | L1 – V1 – 30% L2 – V2 – 44% L3 – V3 – 58% L4 – V4 – 72% L5 – V5 – 86% L6 – V6 – 100% L7 – Open V4 / close V2 L8 – Open V6 / close V4 |
| L4 – FLASH function Adapt to the connected device and output limit. | L1 – Open gate indicator light L2 – Active when the gate is closed L3 – Active when the gate is open L4 – Warning beacon L5 – Electric strike L6 – Electric lock L7 – Electromagnet L8 – Maintenance indicator light |
| L5 – Opening force Increasing the force does not compensate for friction; fix the cause. Measure the impact forces again after changing this setting. | L1 – Force 1 – low L2 – Force 2 L3 – Force 3 L4 – Force 4 L5 – Force 5 L6 – Force 6 L7 – Force 7 L8 – Force 8 – high |
| L6 – Closing force Adjust only after checking the mechanics and safety devices. | L1 – Force 1 – low L2 – Force 2 L3 – Force 3 L4 – Force 4 L5 – Force 5 L6 – Force 6 L7 – Force 7 L8 – Force 8 – high |
| L7 – Maintenance alert Counts operating cycles; one opening and one closing count as two cycles. | L1 – Automatic, based on load L2 – 1,000 cycles L3 – 2,000 cycles L4 – 4,000 cycles L5 – 6,000 cycles L6 – 8,000 cycles L7 – 10,000 cycles L8 – 12,000 cycles |
| L8 – Fault history Read-only, display sequence. | L1 – 1st cycle – most recent L2 – 2nd cycle L3 – 3rd cycle L4 – 4th cycle L5 – 5th cycle L6 – 6th cycle L7 – 7th cycle L8 – 8th cycle |
If the unit uses a value between two levels, two LEDs will flash alternately. This does not automatically indicate a fault. Do not confuse the parameter input LED with its value LED.
Changing the direction of rotation
When idle, hold STOP for 3 s until L1 flashes. Press ▲ + ▼ at the same time: the courtesy light being on indicates the direction is reversed; off indicates the standard direction. Wait 10 s for the process to finish, then repeat position and force learning. Do not change the direction while the gate is moving.
Remote control and antenna
The radio receiver plugs into the SM socket with the mains power and battery disconnected. Do not confuse the equipment supplied with a standalone operator with a complete kit: choose the receiver and transmitters to match the components actually supplied.
NICE OXIBD supports both unidirectional and bidirectional transmitters; a suitable unidirectional transmitter is the NICE MYGO4. An older installed receiver may use a different coding system. The same 433.92 MHz frequency alone is not enough.
In standard mode 1, the receiver outputs are: 1 – step-by-step, 2 – partial opening, 3 – open, 4 – close. Mode 2 allows you to assign an individual button to a selected command. For exact pairing and deletion procedures, follow the instructions for the specific OXIBD receiver; the motor buttons do not erase its radio memory.
For the OXIBD, connect the antenna to the receiver connector according to the OXIBD antenna connection diagram. Connect the coaxial cable's centre conductor to the signal terminal and the shield to the antenna ground. These are not the power supply +/− terminals.
Troubleshooting and resolving the cause
The beacon flashes briefly in a pattern that repeats twice, with a 1 s pause. Remove the cause first; do not overcome an obstruction by increasing the force.
| Signal | Cause and solution |
|---|---|
| 2 flashes | The photocell is obstructing movement. Clean and align the optics, and remove the obstruction; check the addressing. |
| 3 flashes | Increased resistance or force limit triggered. Check the balance, track and springs; perform a test. |
| 4 flashes | STOP. Check the safety edge and its wiring. |
| 5 flashes | Internal parameter error: wait at least 30 s and try the command again. If the fault persists, have the unit serviced. |
| 6 flashes | Operating limit exceeded: let the drive cool down for a few minutes. |
| 7 flashes | Internal electrical fault: disconnect all power sources and check the circuit board and cables. |
| 8 flashes | A continuous command is blocking further commands. Check for a stuck SbS/OPEN/CLOSE contact. |
| 9 flashes | Electronic lockout of the automation system. Use the unlock command; this is not a cable release. |
| LED status at rest | Meaning |
|---|---|
| BlueBUS: once per second | Normal operation. Two quick flashes confirm an input change or a received radio command. |
| BlueBUS – rapid, extended red flashes | Short circuit at the BlueBUS terminal. Check the wiring; normal flashing resumes approximately 10 seconds after the short circuit is cleared. |
| BlueBUS – slow red-green flashing | Normal status while a compatible backup battery is charging in Standby mode. |
| BlueBUS off / continuously lit | Check the power supply, fuses and circuit board; the indicator behaves differently in standby. |
| STOP off | The safety input is not in its stored idle state. |
| L1 + L2 flashing | Devices need to be learned. |
| L3 + L4 flashing | Positions need to be learned. |
| L1 or L8 flashing rapidly on its own | Encoder end-of-travel range. Have a service technician check the mechanical installation; do not force the motor beyond its travel. |
| Courtesy light flashing | Prompt to learn forces or learning in progress; if it coincides with the warning light, it may indicate a diagnostic event. |
During movement, LEDs L1–L8 indicate the motor load: from L1 at low force to L8 at maximum force. This display does not indicate a value selected in the programming menu. If the load increases, check the gate’s mechanical resistance and balance; do not increase the force without carrying out a safety test.
History of the last eight manoeuvres
Enter Level II, select input L8 and hold STOP for about 3 s. Lit LEDs indicate manoeuvres with a fault; L1 is the most recent and L8 the eighth. While holding STOP, select a manoeuvre with ▲/▼: the LED flashes the corresponding diagnostic code. Then release STOP.
Unit reset and encoder servicing
Resetting erases the positions, learned devices and unit settings. This does not erase the receiver.
- With the gate stationary, hold ▲ + ▼ for about 3 s until L1–L8 light up.
- Release the buttons. L2 and L8 flash rapidly for approximately 3 s, and the unit restores the factory settings.
- Repeat the learning procedures for devices, positions and forces, and repeat all safety tests.
Resetting does not change the direction of rotation or the total number of manoeuvres. Encoder reset is a separate service procedure to be performed only on a workbench, never with the motor connected to the gate.
Pre-handover gate checks
- With the drive disengaged, check that the gate moves smoothly and is properly balanced. For the sectional door assembly described here, the force required for manual operation must not exceed 225 N. When selecting SOON, also comply with the door resistance operating ranges in the table above. This force is neither the motor torque nor the permitted impact force.
- After engaging the drive, test opening, closing and STOP; the gate must not jam or travel beyond its stored end positions.
- Test each pair of photocells at the TX, at the RX and in the centre of the beam, for example using a cylinder 5 cm in diameter and 30 cm long. Check the gate’s actual response.
- Test the safety edge, safety circuit and emergency release. Measure impact forces with a suitable instrument; repeat the test after changing the force or sensitivity.
- Hand over the gate only after all tests have been passed, and provide the label, release instructions and maintenance schedule. Only pass through when the gate is fully open and stationary.
Maintenance and safe operation
Have professional maintenance carried out at least every 6 months or after 4,000 manoeuvres since the last service, whichever comes first. Disconnect the mains and battery, then check the anchors, corrosion, wedge, shaft, chain if fitted, springs and guide components. Repeat the safety tests after restoring power.
The maintenance alert in II/L7 supplements the service schedule. If FLASH is set as a maintenance indicator, it flashes throughout the manoeuvre at 81–100% of the limit; above the limit, it flashes continuously, even when the gate is not moving. When FLASH is set as a warning light, maintenance is indicated differently: at 81–100%, it stays on for 2 s at the start; above the limit, it stays on for 2 s at both the start and end of the manoeuvre, then resumes normal flashing. After servicing, enter II/L7, hold STOP and press ▲ + ▼ simultaneously for at least 5 s to reset the service counter. This does not reset the total counter.
If a safety device fails, do not operate the gate automatically. Use safe manual operation and arrange for repairs. Do not attempt to work on tensioned springs yourself.
SOON SO2000 technical specifications
| Parameter | Value |
|---|---|
| Control unit | NICE SOA2R30 built-in; magnetic encoder. |
| Mains power supply | 230 V AC, +10% / −15%, 50/60 Hz; Class I, grounding. |
| Motor | 24 V DC. |
| Mains current draw | Maximum 1.5 A; rated 1 A. |
| Power consumption | Maximum 350 W; rated 220 W. |
| Torque | Maximum 50 Nm; rated 30 Nm; static 130 Nm. The static value is not an available operating torque. |
| Speed | Maximum 30 / rated 18 rpm. |
| Duty cycle | Depends on resistance and travel length; duty cycle table. |
| Area / height | Up to 20 m² / approximately 5 m. |
| Protection rating / temperature | IP40, indoor use; −20 to +50 °C. |
| Dimensions / weight | Approximately 115 × 375 × 300 mm / 10.5 kg. The dimensional drawing shows a height of 298 mm. |
| Fuses | F1 mains 1.6 A; F2 control 1.6 A, time-delay. Replace only with the same type after eliminating the cause. |