NICE Slight SLH400 - drive for sliding gates up to 400 kg (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€452.47 including VAT
| Weight |
|---|
| 7,00 kg |
Description of NICE Slight SLH400 - drive for sliding gates up to 400 kg (A)
NICE SLIGHT SLH400 is a compact electromechanical gate operator for sliding gates weighing up to 400 kg with a leaf length of 6 m, depending on operating conditions. The standalone motor in variant A already includes a built-in control unit NKA3R10 and a light. The motor runs on 24 V DC, while the operator's standard mains supply is 230 V AC.
With a footprint of approximately 191 × 198 mm it is suitable where there is little space beside the gate. The internal limit switches allow installation without a rack-mounted limit-switch plate: for a gate that runs in front of the fence, the operator can, depending on the geometry, be installed on the inside near the edge of the opening, or on a rail-mounted gate with minimal overhang. Rigid gate safety stops and sufficient rack overhang must be retained.
The operator is non-reversible; in the event of a power failure, it can be released with a key. The optional PS124 battery fits inside the operator housing. Features include automatic closing, partial opening for pedestrians, force and speed adjustment, as well as synchronization of two opposing gate leaves.
When to choose the NICE SLH400 operator
Before choosing, check the gate leaf's weight, length and resistance throughout its travel. The gate must move easily, without sticking or moving on its own. Snow, ice, wind and wear increase the load. The rated pulling force is 200 N; for measured resistance to movement, the manufacturer recommends a safety margin of at least 50%, meaning approximately 100 N maximum.
Length, weight and number of cycles
| Gate leaf length | Max. cycles/hour | Max. consecutive cycles |
|---|---|---|
| Up to 4 m | 35 | 14 |
| Over 4 m up to 6 m | 23 | 11 |
| Gate leaf weight | Cycle count adjustment | Maximum speed |
|---|---|---|
| Up to 200 kg | 100% of the stated values | V6 – exceptionally fast |
| Over 200 kg up to 400 kg | 50% of the stated values | V5 – very fast |
For example, a 5 m / 350 kg gate leaf, taking both tables into account, has a maximum of approximately 11 cycles/hour and 5 consecutive cycles, at a maximum speed of V5. One cycle is a complete opening and closing. Higher temperatures may further limit permitted operation; the thermal limiter is no substitute for choosing the right operator.
Standalone motor and kits with accessories
Motor A includes the control unit and a built-in light. Remote control requires a compatible receiver and transmitter; choose the rack, photocells and any separate warning light to suit the installation. Kits B–F include different accessories; the limits for a single gate leaf remain the same.
| Kit | Kit | Kit |
|---|---|---|
| A – standalone motor NKA3R10 and built-in light; receiver, transmitters, photocells and rack are selected separately. | B – basic kit MYGO4 and OXIBD. | C – with photocells MYGO4, OXIBD and one pair of EPMB photocells. |
| D – with photocells and warning light MYGO4, OXIBD, EPMB and ELDC. | E – with photocells and rack MYGO4, OXIBD, EPMB and 4 × 1 m rack sections. | F – with warning light and rack MYGO4, OXIBD, EPMB, ELDC and 4 × 1 m of rack. |
E/F kits include 4 m of rack; for a longer gate, add the required length with an allowance for installation. When replacing the receiver or remote control, check the specific coding.
What you need for the setup
| What | Why | Type |
|---|---|---|
NKA3R10![]() | The control unit is built into the SLH400; this control board is also suitable as a replacement part. | |
EPMB![]() | BlueBUS photocells monitor the hazardous area; choose the function according to the risks. | |
OXIBD![]() | Plug-in radio receiver for compatible remote controls; not automatically included with a standalone operator. | |
PS124![]() | Backup operation during a power outage. | |
WLT![]() | The SLH400 already includes the light electronics; the standalone WLT has its own housing. |
A more compact photocell alternative is EPSB. Both use BlueBUS; relay-type EPM/EPS photocells cannot be connected to BlueBUS as direct replacements.
The toothed pinion uses module 4. A suitable choice is nylon rack with steel reinforcement, or a suitable metal rack with the same geometry. A higher rack rating alone does not increase the SLH400's limit.
Installing the SLH400 operator
The SLH400 uses the control unit NKA3R10. Assess the mechanical installation, housing and internal limit switches based on the actual SLH400 operator.
Installing the operator and rack
Disconnect the mains power and backup battery before starting work. Check the gate's structural integrity, wheels and guide, secure end stops, anti-derailment protection, clear access to the release key, and drainage around the operator. Any door in the gate leaf must have an appropriate movement interlock.
- Set the gate approximately halfway along its travel. Position the operator according to the opening direction and the original installation geometry.
- Prepare a solid, level base, conduit and foundation plate. For cast-in anchors, leave approximately 20–30 mm of thread above the plate; allow the concrete to cure fully.
- Install the operator parallel to the gate leaf, initially securing it lightly, and check its alignment with the rack.
- Release the operator and position the gate at least 50 cm from the closing stop while installing the rack. Fit the rack sections progressively along the pinion, with no step between sections.
- Maintain a 1–2 mm clearance between the rack and pinionalong the entire travel; the gate's weight must not rest on the pinion. Lateral misalignment must not exceed 5 mm.
- Open and close the gate manually several times, checking alignment, clearances and stops. Tighten the operator securely and fit the fixing caps.
Internal limit switches and fine adjustment of positions
The SLH400 does not require switching strips on the rack. However, the gate's mechanical safety stops must remain secure and functional. Initially, adjust the internal mechanism by manually moving the gate through its full travel.
- Release the operator and manually open and close the gate fully. Check the rack clearance and alignment during movement.
- Move the gate back to halfway along its travel and engage the operator. Then perform travel learning.
- For fine adjustment, remove cover A from adjustment wheels B. Select the wheel according to the direction arrow, not by guessing left or right.
- Half a turn corresponds to an adjustment of approximately 3 cm. Use an OPEN/CLOSE command to run the gate again and check the result; make small adjustments.
- To repeat the entire setup, turn both wheels towards “−” until the microswitches activate, as shown, then repeat the complete adjustment procedure. Finally, refit the cover.
Cable preparation
| Cable run | Cross-section and length |
|---|---|
| Mains supply cable | 3 × 1.5 mm², up to 30 m; for longer runs, 3 × 2.5 mm² and suitable protective earthing in accordance with the installation requirements. |
| Warning light | 2 × 0.5 mm², up to 20 m. |
| Antenna | RG58, up to 20 m; a length under 5 m is recommended. |
| BlueBUS photocells | Up to 30 m: 2 × 1.5 mm². For runs of 30–50 m, determine the cross-section based on length, current draw and voltage drop; do not reduce the cross-section simply to extend the run. |
| Safety edge | 2 × 0.5 mm², up to 30 m; a moving safety edge requires a suitable signal transmission device. |
| Key switch | Two runs of 2 × 0.5 mm² or one run of 4 × 0.5 mm², up to 50 m. |
Leave approximately 20–30 cm of cable slack for connection, use strain relief, and route cables away from moving parts. The mains supply has separate L/N and PE conductors; do not connect 230 V to the signal terminals. The power supply must allow safe, complete disconnection.
NKA3R10 control unit – terminals and wiring diagram
Check the model and board markings before wiring. The following procedure uses the layout FLASH, OGI, BlueBUS, STOP, SbS, OPEN, CLOSE and AUX IN and eight LEDs, L1–L8. The control unit is part of the drive; the separate NKA3R10 is also a spare part, so you don’t need to buy a second one for a new, complete motor.
| Terminal / connector | Purpose and conditions |
|---|---|
| FLASH | Warning light with a designated 12 V input; for incandescent warning lights, no more than two 12 V / 21 W bulbs. Polarity does not matter for an incandescent bulb. For an LED warning light, observe its specified input and markings; check the +/− polarity on the specific output before connecting. This is not a mains power supply. |
| OGI | Programmable 24 V output, maximum 4 W, tolerance −30 / +50%. Function according to level II/L4. It is not interchangeable with FLASH. For a polarity-sensitive DC light or relay, check the +/− polarity on the specific output before connecting; polarity does not matter for an incandescent bulb. |
| BlueBUS | Two-wire devices connected in parallel, with no polarity; maximum 15 BlueBUS load units, not automatically 15 pairs. |
| STOP | NO, NC or 8.2 kΩ resistor, depending on the learned configuration; a dry contact or resistor on its own has no polarity. When the state changes, it stops and briefly reverses movement. Connect safety edges according to their specified interface. |
| SbS | Dry NO contact for step-by-step operation, with no polarity; function at II/L2. |
| OPEN / CLOSE | Dry NO contacts for opening / closing, with no polarity. CLOSE can be changed to partial opening at I/L7. |
| AUX IN | Factory-set NC Stop input; the dry contact has no polarity, and opening it stops movement. Set another function using the appropriate programming accessory; do not guess and bridge terminals. |
| ANTENNA / SM | Receiver coaxial antenna / radio receiver socket. |
| IBT4N / battery | Dedicated BusT4 interface / PS124 connector. Do not connect these to signal terminals instead of their designated connectors. |
Built-in WLT light
The SLH400 includes WLT light electronics under the drive’s own cover; the separate WLT is a complete unit with its own plastic cover. Depending on the wiring and settings, the built-in light can be used as a warning light or for area lighting.
For OGI, the appropriate function must be set in II/L4; by default, OGI is controlled by radio output 3, so it does not automatically flash during every movement. The following original photos show the cover, electronics and connection. Disconnect all power supplies before changing any wires.
The WLT power input is designed for 12–24 V AC/DC; when working on it, retain the specified wiring of its power connector. Do not automatically substitute another LED light or relay. At 24 V DC, the WLT draws approximately 140 mA, or 3.36 W. When powered from OGI, observe its 4 W total limit; do not add another load without recalculating. Do not connect the WLT to the STOP/SbS auxiliary output, which has a 100 mA limit. If changing to FLASH, check the designated wiring and warning function; do not connect the two outputs together.
Powering small accessories
The auxiliary power supply provides 24 V DC (−30 / +50%), maximum 100 mA. The left and right terminals below are described as viewed from the connector side, with the STOP and SbS labels readable, in the same orientation as in the original image.
| Polarity on the board | Connecting an accessory |
|---|---|
| Plus (+) | Left terminal of the SbS pair → accessory power supply + terminal. |
| Minus (−) | Right terminal of the STOP pair → accessory power supply − / 0 V terminal. |
The total current draw of connected accessories must not exceed 100 mA. The STOP/SbS power pair is not the same as the STOP contact or step-by-step command: connect a dry contact across the two terminals of its corresponding pair. BlueBUS photocells are powered from BlueBUS, not from this auxiliary pair.
Do not connect the WLT to this auxiliary output: it draws approximately 140 mA at 24 V DC. Its wiring and the OGI limit are covered in Built-in WLT LED light.
Photocells and BlueBUS learning
The TX and RX units in one pair must have the same address jumpers; the next pair must have a different address. Set the jumpers according to EPMB or EPSB and the functions supported by the board. After making changes, repeat the learning procedure.
FOTO / FOTO II and FOTO 1 / FOTO 1 II provide protection during closing; FOTO 2 / FOTO 2 II provide protection during opening. FOTO 3 covers the entire automation system; when used together with FOTO II, the specified relative positioning of TX/RX must be observed. Test the safety functions by operating the gate, not just by checking whether the LED is lit.
Initial startup
Move the gate to approximately the middle of its travel and engage the motor. With the power off, use the selector to set the opening direction according to the drive position and arrows. After powering on, BlueBUS should flash once per second, the photocells should signal, and the FLASH/OGI outputs should be in their idle state according to the configuration.
1. BlueBUS and STOP learning
- Press and hold OPEN + STOP/SET simultaneously for approximately 3 seconds.
- When L1/L2 flash rapidly, release the buttons and wait.
- When complete, STOP should be lit and L1/L2 should be off; L3/L4 may indicate that travel learning is required.
Perform the learning procedure even when no accessories are connected. Adding or removing a device requires relearning and retesting.
2. Travel-length learning
- Press and hold CLOSE + STOP/SET for approximately 3 seconds, then release when movement starts.
- The first movement must be opening. If the direction is reversed, immediately press STOP/SET, disconnect the power supply, correct the direction setting, and repeat the entire procedure.
- Wait until it is fully open and then closed. The learned travel path determines both the slowdown and partial opening.
- Check the end positions and fine-tune as needed internal switches.
Safety tests and handover
Run several full cycles; check the slowdown before the end, the rack alignment, and smooth movement along the entire travel path. Test the photocells, safety edges, STOP, and control inputs separately. Measure impact forces and verify the response to an obstacle. The user must be given the key, the release procedure, and a maintenance schedule; begin normal operation only after the safety handover.
Control unit programming
OPEN ▲ opens and moves the selection, STOP/SET ■ stops and confirms, CLOSE ▼ closes and moves the selection in the opposite direction. The following tables use eight LEDs, L1–L8; the input LED selects a parameter, and the value LED shows its setting.
Level I – enabling and disabling functions
- Hold STOP/SET until L1 starts flashing, then release the button.
- Use OPEN/CLOSE to select the LED for the required function.
- Briefly press STOP/SET to change the state: a short flash means OFF, a long flash means ON.
- Use OPEN/CLOSE to select the next function, then press STOP/SET again to toggle it. After 10 s without a button press, the changes are saved and programming ends.
| Function and description | ON/OFF state |
|---|---|
| L1 – Automatic closing ON: after opening and the set pause, closing starts. OFF: waits for the next command. Set the time in Level II/L1. | ON = enabled OFF = disabled Factory setting: OFF |
| L2 – Close after photocell ON: closes 5 s after the photocell beam is cleared. With automatic closing disabled, it completes the opening cycle first; when enabled, it may end the opening cycle as soon as the beam is cleared. A STOP command cancels this function for the current cycle. OFF: closing is controlled by the Automatic Closing function and the set pause. | ON = enabled OFF = disabled Factory setting: OFF |
| L3 – Always close ON: after power is restored, it closes if it detects that the gate is open; the warning light flashes for 5 s before movement. OFF: remains in its current position. | ON = enabled OFF = disabled Factory setting: OFF |
| L4 – Standby ON: one minute after a cycle, it switches off BlueBUS and most LEDs; a new command reactivates them. Saves battery power. OFF: energy-saving mode is disabled. | ON = enabled OFF = disabled Factory setting: OFF |
| L5 – Starting force ON: disables the soft start and applies a starting impulse. OFF: smooth acceleration. This is not a substitute for repairing a gate that is sticking. | ON = enabled OFF = disabled Factory setting: OFF |
| L6 – Pre-flashing ON: the warning light starts flashing 3 s before movement. OFF: it flashes when movement starts. | ON = enabled OFF = disabled Factory setting: OFF |
| L7 – CLOSE as partial opening ON: the CLOSE input commands partial opening. OFF: closing. | ON = enabled OFF = disabled Factory setting: OFF |
| L8 – Slave mode ON: slave motor in a pair of opposing leaves. OFF: standalone motor or master motor. See pair wiring. | ON = enabled OFF = disabled Factory setting: OFF |
Level II – adjustable parameters
- Hold STOP/SET until L1 flashes, then release it.
- Use OPEN/CLOSE to select the parameter input LED.
- Hold STOP/SET; after approximately 3 s, the value LED lights up. Keep holding STOP/SET and use OPEN/CLOSE to select the new value.
- Release STOP/SET. Set the next parameter in the same way; programming ends after 10 s without another button press.
The basic factory settings are shown in bold. Settings on a board that is already in use may differ. L8 history has no adjustable factory setting.
| Input LED – name and description | Setting LED – value |
|---|---|
| L1 – Pause time Waiting time before automatic closing, if Level I/L1 is enabled. | L1 – 5 s L2 – 15 s L3 – 30 s L4 – 45 s L5 – 60 s L6 – 80 s L7 – 120 s L8 – 180 s |
| L2 – Step-by-step (SbS) Wired SbS input and first radio command. The hold-to-run mode requires the command button to be held down. | L1 – Open – stop – close – stop L2 – Open – stop – close – open L3 – Open – close – open – close L4 – Condominium mode L5 – Condominium mode 2; a command lasting more than 2 s triggers Stop L6 – Step-by-step 2; a command lasting less than 2 s triggers partial opening L7 – Hold-to-run L8 – Semi-automatic opening, hold-to-run closing |
| L3 – Motor speed For a leaf weighing over 200 kg, use no more than V5; operating limits take precedence. | L1 – V1 – very slow L2 – V2 – slow L3 – V3 – medium L4 – V4 – fast L5 – V5 – very fast L6 – V6 – exceptionally fast L7 – Open quickly, close slowly L8 – Open exceptionally quickly, close quickly |
| L4 – OGI output 24 V when active, max. 4 W. Also check WLT wiring. | L1 – Gate-open indicator L2 – Active when the gate is closed L3 – Active when the gate is open L4 – Radio output 2 control L5 – Radio output 3 control L6 – Radio output 4 control L7 – Service indicator L8 – Electric lock |
| L5 – Motor force Choose based on resistance along the entire travel path, not just the weight; measure impact forces after making a change. | L1 – Extremely light gate L2 – Very light gate L3 – Light gate L4 – Medium-light gate L5 – Medium-heavy gate L6 – Heavy gate L7 – Very heavy gate L8 – Extremely heavy gate |
| L6 – Partial opening Pedestrian opening distance. Command from a radio control or CLOSE input when level I/L7 is enabled. | L1 – 0.5 m L2 – 1 m L3 – 1.5 m L4 – 2 m L5 – 2.5 m L6 – 3 m L7 – 3.4 m L8 – 4 m |
| L7 – Service notification Number of operating cycles before the service signal; automatic mode takes operating difficulty into account. | L1 – Automatic, based on operating difficulty L2 – 1,000 operating cycles L3 – 2,000 operating cycles L4 – 4,000 operating cycles L5 – 7,000 operating cycles L6 – 10,000 operating cycles L7 – 15,000 operating cycles L8 – 20,000 operating cycles |
| L8 – Anomaly history The last eight operating cycles; read-only. Display sequence. | L1 – Result of operating cycle 1 – most recent L2 – Result of operating cycle 2 L3 – Result of operating cycle 3 L4 – Result of operating cycle 4 L5 – Result of operating cycle 5 L6 – Result of operating cycle 6 L7 – Result of operating cycle 7 L8 – Result of operating cycle 8 |
Do not compensate for friction, incorrect balancing or an obstruction by using excessive force. After changing the force or speed, repeat the safety tests and measure the impact forces.
Two SLH400 units for opposing gate leaves
Master–Slave synchronizes two separate motors; each drives its own gate leaf within its permitted limits. The pair does not increase the limit for an individual gate leaf. The BlueBUS connection and safety devices must follow the specified wiring diagram for the pair.
- With the power supplies switched off, connect the BlueBUS terminals on both control boards; connect terminal 1 to 1 and 2 to 2 as shown in the enlarged detail of the original diagram. With the connectors oriented the same way, connect left to left and right to right; do not cross the wires between the control boards. These are not the photocell power supply +/− terminals. Set the correct opening direction for each motor.
- After switching on the Slave motor, enable I/L8 Slave.
- Program the devices on the Slave first, then on the Master. Program the travel limits on the Master.
- Connect shared commands, the receiver and shared safety devices to the Master. The Slave can have its own STOP edge, FLASH, OGI and its own SbS input for its separate full opening; OPEN/CLOSE/AUX IN are not used on the Slave.
- For backup power, each motor needs its own PS124. The Slave retains separate Stand-by, start-up, OGI and force settings; test the safety of both gate leaves.
Remote control and backup power
Insert the radio receiver into the SM connector with both the mains and battery power switched off. A standalone motor or barrier cabinet does not automatically include a receiver and remote control; check the equipment supplied with the specific kit. Current kits use OXIBD. Pairing, deleting transmitters and locking the radio memory are configured on the receiver according to its own instructions.
| Receiver output in basic mode | Command |
|---|---|
| 1 | Step-by-step (SbS) |
| 2 | Partial opening |
| 3 | Open |
| 4 | Close |
NICE remotes choose according to the receiver's coding. Era One, Era Inti and MYGO transmitters with compatible coding pair with the corresponding family; matching frequency alone does not confirm compatibility. Do not assess mixing different coding types in one memory based solely on the transmitter name.
PS124 backup battery
PS124 is an optional 24 V rechargeable battery. It provides a limited number of operating cycles during a power failure; the number depends on the charge level, temperature and load. Connect it to the designated battery connector only after installation and programming. Switch off the mains before connecting, secure the battery in place, then restore power after connection. Disconnect the battery as well when servicing.
Use the supplied PS124 connection cable: the narrower connector goes to the battery, the wider one to the control board. Connect it to the designated battery connection, not to BlueBUS, FLASH or the 24 V auxiliary output. With the original supplied PS124 cable, there is no need to determine the +/− polarity; use both designated connectors. Do not modify the connectors by force.
- With the mains disconnected and a charged battery connected, L2 on the PS124 should confirm that the automation is powered.
- When the mains is switched on, L1 should confirm that the battery is charging. If the battery is discharged, leave the system to charge and repeat the test.
- Test a complete operating cycle on mains power, then disconnect the mains and verify both opening and closing on battery power. Speed may be lower when running on backup power.
- Restore mains power after the test.
For solar-only power Solemyo SYKCE30 the drive must not be connected to the mains at the same time. System selection and connection of the PSY24 must take into account the specific control board, number of cycles, accessories and local sunlight conditions.
Diagnostics and troubleshooting
The short flashes of the warning light form two identical groups separated by approximately 1 s. Count the flashes in one group. During normal operation, BlueBUS flashes once per second; two quick flashes confirm an input change.
| Flashes | Meaning and what to check |
|---|---|
| 1 | BlueBUS error: check the wires, addresses, and relearn the devices. |
| 2 | The photocell is blocking movement. Remove the obstruction, clean and align TX/RX; check the addresses. |
| 3 | Increased resistance / force limit triggered. Check the mechanism and the rack; do not increase the force blindly. |
| 4 | STOP activated. Check the contact or resistive circuit; do not bypass the safety input to clear a fault. |
| 5 | Internal parameter error. Wait at least 30 s and try the command again. If the error persists, the control board needs servicing. Relearning is not a complete reset. |
| 6 | Operating frequency exceeded. Wait a few minutes and observe the permitted number of cycles. |
| 7 | Internal electrical fault. Disconnect both the mains and the battery; if the fault recurs, the control board or motor wiring needs servicing. |
| 8 | A continuous command is preventing another command. For example, check the timer on OPEN. |
| 9 | The automation system is software-locked. Use the appropriate command to unlock the automation system; this is not a mechanical key release. |
| Indicator / LED | Action |
|---|---|
| BlueBUS is off | Check the power supply and fuses. Replace only when power is disconnected and the cause has been eliminated; always use the same type and rating. |
| BlueBUS is continuously lit | Serious fault. Disconnect both the mains and the battery for a few seconds, then restore power. If the condition persists, the control board needs servicing. |
| STOP is off | STOP does not match the learned safe state. Check the connected device and learning. |
| L1 + L2 flashing | The connected devices need to be learned. |
| L3 + L4 flashing | The positions / travel path need to be learned. |
| Remote control lights up, but the operator does not respond | Check the battery, compatible coding, and whether it is stored in the receiver. |
| SbS / OPEN / CLOSE continuously lit | A command contact may be stuck closed; check the button, relay, and wiring. |
History of the last eight operations
- Enter programming using STOP/SET, then use OPEN/CLOSE to select input LED L8.
- Hold STOP/SET for approximately 3 s. The lit value LEDs indicate operations with an anomaly; L1 is the most recent and L8 is the eighth.
- While holding STOP/SET, use OPEN/CLOSE to select the relevant operation. The LED displays the number of error flashes shown in the table above.
- Release STOP/SET and allow the menu to exit.
Relearning and radio memory
Learning the devices again is not a complete control board reset. The service counter has its own procedure and transmitters are erased at the receiver. Record important settings before carrying out any work; incorrect deletion can erase learned safety devices.
After changing accessories, repeat the BlueBUS and STOP learning; after changing the travel path, repeat position learning. Erase transmitters at the radio receiver. Have a service technician perform a complete configuration reset for the specific NKA3R10; do not use the button-reset procedure from another operator.
Manual release
- Stop the operator, insert the key, and turn it 90° clockwise.
- Move the gate manually along its safe travel path; do not force it past the end stops.
- To re-engage the operator, turn the key 90° in the opposite direction, remove it, and check that the mechanism is engaged before sending another electrical command.
Maintenance and safe use
Service at least every 6 months or 20,000 operations, whichever comes first. Shorten the interval for demanding operating conditions. A service alert does not replace regular inspections.
- Disconnect both the mains and the backup battery before carrying out any work.
- Check the anchors, corrosion, wiring, rack, pinion, wheels, gate guides, and end stops. Replace damaged parts.
- Clean the photocells, check their response, and test the manual release. Repeat the safety tests after servicing.
- Keep remote controls out of reach of children. Keep clear of the gate’s travel path and do not use equipment that needs repair.
Service alert and resetting the service counter
Enter Level II programming and select input LED L7. Hold STOP/SET for approximately 3 s until the value LED appears, and keep holding it during the following steps. Briefly press OPEN + CLOSE together to display the consumed share of the limit: one flash = approximately 10%. After servicing, on the same parameter, hold STOP/SET and press OPEN + CLOSE simultaneously for at least 5 s; rapid flashes confirm the reset. Then release STOP/SET. This does not erase transmitters or replace a complete reset.
| Limit exceeded | Signal |
|---|---|
| Below 80% | The warning light flashes normally; the service indicator lights for 2 s when opening. |
| Approximately 81–100% | The warning light stays lit for 2 s at the start of movement; the service indicator flashes during operation. |
| Above 100% | The warning light stays lit for 2 s at both the start and end; the service indicator flashes continuously. |
The service indicator works only when the relevant setting is enabled output. At the end of its service life, take the device and batteries to an appropriate collection point; do not dispose of them with household waste.
Estimated service life by operating conditions
| Features of the complete automation system | Index | Service life graph |
|---|---|---|
| Gate leaf length | Under 3 m: 0%; 3–4 m: 5%; 4–5 m: 10%; 5–6 m: 20%. | |
| Weight | Under 200 kg: 0%; 200–300 kg: 15%; 300–400 kg: 30%. | |
| Temperature / humidity | Above 40 °C, below 0 °C, or humidity above 80%: 20%. | |
| Dust, sand or salinity | 15%. | |
| Speed above V4 | 15%. |
Add the relevant indices, find the total on the horizontal axis, and read the estimated number of cycles from the curve. This is an estimate assuming correct installation and regular maintenance, not a guarantee or a service interval.
NICE SLH400 technical specifications and dimensions
| Parameter | Value |
|---|---|
| Motor / control board | 24 V DC / built-in NKA3R10 |
| Mains power supply | 230 V AC (+10 / −15%), 50/60 Hz; protective earth |
| Gate leaf limits | 400 kg / 6 m, taking resistance and operating tables into account |
| Thrust force | 400 N at start-up / 200 N rated |
| Torque | 12 Nm at start-up / 6 Nm rated |
| Speed | 0.18 m/s at rated torque; 0.34 m/s no-load. Higher speeds are limited by the weight. |
| Max. power consumption at start-up | 330 W |
| Max. continuous operation | 10 min at rated torque |
| Pinion | 15 teeth, module 4, pitch 12.6 mm, pitch diameter 60 mm |
| Protection rating | IP44 when correctly installed |
| Operating temperature | −20 to +55 °C |
| Footprint and height as shown in the drawing | 191 × 198 mm; height 408 mm |
| Light / backup | Built-in WLT electronics / optional PS124 |
The installation drawing also shows the pinion position; before preparing the foundation, check the rack height on the specific gate and ensure access to the manual release.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]




























