NICE OLTRE1824 – concealed swing gate operator

NICE OLTRE1824 is a standalone electromechanical operator for residential swing gates, for a single leaf up to 1.8 m and 100 kg. The 24 V DC motor is concealed inside the hollow vertical leaf profile, beside its pivot axis. The bottom section is anchored to the ground. It is a non-reversible; in the event of a power failure, it allows manual release using a lever.

It requires a separate NICE MC824L control unit. The motor’s 24 V DC voltage does not mean that the control unit connects to a 24 V mains supply: its mains input is 230 V AC.

Quick navigation
Choosing an operatorAccessories
Package contents and controlInstallation
DimensionsRelease
WiringConnections
PhotocellsInitial setup
SettingsRemote controls
TroubleshootingMaintenance
SpecificationsPDF manual

When to choose the OLTRE1824

It is suitable where you want to keep the swing gate’s appearance clean, without a visible piston-type operator or arm. Space for the motor must be allowed for when designing the gate leaf. The profile must have internal clearance for a motor at least 56 mm in diameter and the mounting must allow precise alignment with the hinges.

Single leafMaximum 1.8 m / 100 kg; selection also depends on smooth movement, infill and wind exposure.
Opening speedApproximately 10 s to 90° under rated conditions; acceleration and deceleration affect the total time.
DutyUp to 60 cycles per hour at rated torque. One cycle is one opening and one closing.
Mechanical stopsFixed open and closed stops are required for correct operation and setup; they are not included with the operator.

The gate leaf must move easily by hand without catching. Do not use the motor’s force to overcome a faulty hinge or an incorrectly hung gate.

NICE OLTRE – concealed operator inside the gate leaf profile

Standalone motor and control unit

This listing is for one OLTRE1824 motor, not a complete automation system for the entire gate. A double-leaf gate requires two motors. MC824L controls one or two OLTRE1824 motors without an encoder; the motor has two power wires. With one motor, use output M2 and leave M1 unused.

MC824L and MC824H are not interchangeable. For OLTRE, choose MC824L; matching motor voltage alone is not enough to select a different control unit. Choose photocells, a warning light, receiver and remote controls to suit the setup.

Operator accessories

ComponentApplication
Separate control unitNICE MC824L for one or two OLTRE1824 motors without an encoder.
BlueBUS photocellsNICE EPMB or NICE EPSB – slim version. Two-wire power and communication with no polarity; run device setup again after making a change.
Warning lightNICE ELDC for the low-voltage FLASH output. The mains-powered ELAC warning light is not suitable for this output.
Radio controlNICE OXIBD for the SM socket and compatible NICE remote controls. The remote control type and coding must be compatible with the receiver.

Dimensions and pivot-axis position

OLTRE1824 – original dimensioned drawing of the operator

The outside diameter of the motor’s cylindrical section is 54 mm. When preparing the profile, allow for internal clearance and hinge position; the box-section’s external dimensions alone are not enough.

OLTRE1824 – pivot axis, dimensions A, A1, B and B1, and template

Distances A, A1, B and B1 must each be at least 31 mm. Measure from the pivot axis to the relevant inner profile walls, as shown in the diagram. Position the mounting plate and motor in relation to the actual hinge axis, not an estimated centre of the profile.

Installing the operator in the gate leaf

Disconnect the mains supply and any backup power source before starting work. Secure the gate leaf against falling or moving on its own.

  1. Check that the gate is sturdy, moves freely and has hinges on a common axis. Fit solid open and closed stops.
  2. Measure the pivot-axis position inside the profile and transfer it to the mounting template. Align the plate with the axis as shown in figures 5–7.
  3. Drill the fixing holes using the template; figure 8 shows Ø 8 mm holes. Install the plate without twisting it.
  4. Prepare the cable passage and motor section as shown in figures 10–14. Do not strike the gearbox with a hammer. Use M6 × 30 fasteners as shown in the drawing.
  5. Insert the motor into the profile, connect it to the mounting plate, and transfer the bottom base position precisely onto the ground. Drill and anchor it as shown in figures 15–17.
  6. With the operator released, move the gate leaf by hand through its full travel to check it. Check the alignment, cable, and free movement all the way to both stops.

OLTRE1824 – shaft alignment, template, and mounting plate

OLTRE1824 – motor fastening, cable exit, and insertion into the profile

OLTRE1824 – base anchoring and mechanical gate stops

Manual release and re-engagement

First disconnect the power and hold the gate leaf, especially in windy conditions. The release allows the gate to be moved manually in the event of a power failure or malfunction.

  1. On the accessible side, turn the lock cover 180°.
  2. Insert the release lever and turn it 180° clockwise.
  3. Remove the lever, close the cover, and move the gate leaf manually.

OLTRE1824 – release using the lever, Figure 19

To re-engage the drive, open the cover, insert the lever, and turn it 180° counterclockwise. Remove the lever, close the cover, and move the gate leaf slightly until the drive engages audibly. Only then restore the power and check the movement.

OLTRE1824 – re-engagement and checking that the drive engages

Wiring for MC824L and OLTRE

ConnectionCable / length
Mains supply to MC824L3 × 1.5 mm², max. 30 m; size longer supply cables separately.
OLTRE1824 motorSupplied 3 m two-core cable; for the MC824L motor cable, 2 × 1.5 mm², max. 10 m.
BlueBUS2 × 0.5 mm² up to 20 m; over 20 m, max. 40 m with 2 × 1 mm².
FLASH2 × 0.5 mm², max. 20 m.
Key switch2 cables, each 2 × 0.5 mm², or 1 cable 4 × 0.5 mm², max. 50 m.
AntennaRG58 coaxial cable, max. 20 m; recommended length under 5 m.

Any extension of the motor cable must be housed in a protected junction box, which is not supplied with the drive. Cables and cable glands must be suitable for outdoor use. Prevent water from entering the electronics through the conduit.

MC824L wiring

The following diagram is for the MC824L with a 12-position motor selector and eight LEDs, L1–L8. Connect the OLTRE motor's blue and brown wires to the M1 or M2 motor output; never directly to 230 V. The polarity of the motor wires determines the direction of travel and is checked during setup.

MC824L – original wiring diagram for OLTRE two-wire motors without an encoder

Terminal / deviceConnection and polarity
M1 / M224 V DC motor. With one motor, use M2 only; with two, M2 opens first and M1 closes first. The ENC inputs are not used with the MC824L.
BlueBUSPhotocells EPMB / EPSB in parallel using two wires. No +/− polarity.
STOPVoltage-free safety input: NO, NC, or 8.2 kΩ resistor, depending on the device. The type is detected during setup; the contact has no polarity.
SbS / OPEN / CLOSEVoltage-free switching contacts, NO. SbS: step-by-step; OPEN: open; CLOSE: close. Do not apply an external voltage to the input.
Auxiliary power supplyRight-hand STOP terminal = negative (−); left-hand SbS terminal = positive (+) as shown in the detail in the diagram. 24 V DC −30/+50%, max. 200 mA total. The remaining terminals serve the corresponding input.
FLASHLow-voltage warning light; output for a 12 V bulb up to 21 W; suitable for NICE ELDC. Follow the markings on the connected device; do not infer the +/− positions from wire color.
ELS12 V electric lock AC, max. 15 VA; the AC output has no +/− polarity.
OGIGate-open indicator, 24 V DC, max. 4 W. The function depends on the settings; do not confuse it with FLASH.
AntennaCoaxial cable: connect the center conductor and shield to the marked terminals; these are not power +/− connections.

BlueBUS photocells

Both the TX transmitter and RX receiver of the photocells EPMB or EPSB connect in parallel to BlueBUS with no polarity. Set the same address on both units in one pair using the jumpers; any additional pair must have a different address according to its function. Basic address PHOTO protects closing. With the MC824L, PHOTO 3 is not used. After adding, removing, or changing an address, repeat the device setup and safety test.

Initial startup and setup

First, move the gate leaves manually to approximately the middle of their travel and engage the drive. Before switching on, check the fixed stops and wiring.

  1. Motor selector: with the power disconnected, set for OLTRE1824: DIP 9 ON; DIP switches 1–8 and 10–12 OFF. Set this before setting the travel limits.
  2. Initial check: After switching on, BlueBUS should flash about once per second, the photocell LEDs should flash, and the warning light should be off.
  3. Device setup: press and hold OPEN + STOP/SET. When L1 and L2 start flashing rapidly, after about 3 s, release the buttons. Wait; STOP should remain lit and L1/L2 should go out. This step must also be performed when no devices are connected.
  4. Automatic travel limit setup: press and hold STOP/SET + CLOSE and release when L3/L4 flash rapidly, after approximately 5 seconds. With two motors, the sequence is: slow closing of M1, slow closing of M2, slow opening of M2 and M1, then rapid closing of both. With one motor on M2, the control unit automatically detects the single-motor setup and learns only that gate leaf; the first movement must be closing.
  5. If the direction is incorrect, or if M2 closes first on a double-leaf gate, stop the learning procedure using the OPEN or CLOSE button. Disconnect both the mains supply and the backup power before changing the wiring. For two motors with the wrong sequence, swap the M1/M2 outputs; for the wrong direction, swap the two motor wires concerned. A single motor remains connected to M2. OLTRE has no encoder wires.
  6. Successful learning ends when L3/L4 go out. If learning is interrupted by a photocell or STOP and L1 flashes, fix the cause and repeat the learning procedure.

MC824L – selector position for OLTRE1824, DIP 9 ON

Then check operation all the way to the end stops, test the photocells and safety edges, and measure impact forces. Hand over the gate only after the complete system has passed testing.

MC824L settings

Automatic closing, closing after photocell activation, closing after power is restored, Stand-by, ELS output function, pre-flashing, changing CLOSE to partial opening, and maintenance indication are first-level functions L1–L8. Check the current status on the LEDs; the Stand-by setting and the time at which programming ends may vary depending on the control unit version.

On a board with eight LEDs, hold STOP/SET until L1 flashes, use OPEN/CLOSE to select a function, then briefly press STOP/SET to toggle it. A short flash means OFF; a long flash means ON. Wait for programming to end automatically.

Second-level parameterWhat it controls
L1 – pauseTime before automatic closing.
L2 – step-by-stepSequence of responses to an SbS command and step-by-step radio control.
L3 – speedMotor operating speed.
L4 – release after closingRelieves the motors after the closed position is reached.
L5 – forceForce level; verify the setting by measuring safety performance.
L6 – partial openingPedestrian opening range, including the M2 leaf operating on its own.
L7 – service intervalNumber of operations before a maintenance warning.
L8 – error memoryResults of the last eight operations.

To change a second-level parameter, select its LED and hold STOP/SET; the current value lights up after approximately 3 seconds. Keep holding STOP/SET and use OPEN/CLOSE to select a value. Release the button and wait for programming to finish. The specific values must match the version of the installed MC824L. For basic wiring and commissioning, use the MC824L quick guide; refer to the manual supplied with the control unit for the full parameter ranges. After changing the force setting, repeat the safety measurements.

Remote controls

The remote control is stored in the installed radio receiver, not in the motor. For example, connect an OXIBD; use a NICE remote control with the matching frequency and coding. The pairing and deletion procedure depends on the specific receiver.

For OXIBD, connect the external antenna directly to the receiver, to the marked contacts for the coaxial cable core and shield. Do not use the antenna terminal on the control unit's main board instead. Disconnect the power supply before inserting the receiver or changing the wiring.

If the gate does not move

SymptomWhat to check
Motor does not drive the gate after unlockingCheck that the drive has been re-engaged and secured after moving the gate manually.
L1 + L2 flashingConnected devices need to be learned. Also check BlueBUS and STOP.
L3 + L4 flashingThe positions need to be learned after correctly setting the selector and end stops.
STOP is not lit after learningCheck the safety circuit; do not bypass it with a jumper.
Wrong direction or sequenceStop the movement, disconnect the power supply, and correct the motor connections according to the initial startup procedure.
Remote control does not work, but the button on the control unit doesCheck the remote control battery, pairing, and receiver compatibility.
Repeated stopping or reversingFirst remove any obstruction and check manual operation. Increasing the force does not fix mechanical problems.

If the fault recurs, note the number of beacon flashes and the LED status, and contact a service technician. Diagnostics and memory deletion depend on the installed MC824L; the procedure for MC824H does not automatically apply to OLTRE.

Use and maintenance

Keep people clear of the gate leaf while it is moving. Keep remote controls out of children's reach. Stop automatic operation if you notice unusual noise, loose fixings, or a fault in a safety device.

Professional inspection at least every 6 months includes checking fixings, corrosion, hinges, end stops, wiring, manual release, and repeating the safety test. Disconnect both the mains supply and the battery before servicing. Users may keep the gate area and photocell optics clean without dismantling the drive.

OLTRE1824 technical specifications

Motor power supply24 V DC
Rated / maximum current draw1 A / 2.9 A
Rated / maximum power consumption25 W / 70 W
Rated / maximum torque60 Nm / 150 Nm
Rotational speed1.5 rpm
Operating angle0–120° (±10°); the specific range depends on the design and installation.
Number of cyclesUp to 60/hour at rated torque
Motor protection ratingIP67
Operating temperature−20 to +50 °C
Motor weight5.5 kg
DimensionsAs shown in the dimension drawing above; cylindrical motor section Ø 54 mm.

Example application

NICE OLTRE – example of a drive concealed in the gate leaf

PDF installation manual

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE OLTRE 1824 – single actuator for swing gates, for gate leaves up to 1.8 m / 100 kg

Product: NICE OLTRE 1824 – single actuator for swing gates, for gate leaves up to 1.8 m / 100 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.