NICE Naked Sliding NKSL400 – exposed sliding gate operator for gates up to 6 m/400 kg (A)
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€462.23 including VAT
| Weight |
|---|
| 6,50 kg |
Description of NICE Naked Sliding NKSL400 – exposed sliding gate operator for gates up to 6 m/400 kg (A)
NICE NAKED NKSL400 – drive concealed in the post
NICE NKSL400 is a compact electromechanical drive for a sliding gate up to 6 m and 400 kg, designed for installation directly inside a hollow post. It is supplied without external covers and with a built-in NKA3R10 control unit. The motor itself runs on 24 V DC, and the complete assembly is powered from the 230 V AC.
It is non-reversible, with internal adjustable limit switches and position monitoring by an absolute encoder. There is no need to install limit-switch activators on the rack. However, the gate still needs fixed mechanical end stops to prevent it from running off the track.
When to choose the NKSL400
Choose NAKED if you want to conceal the motor inside the post structure and have room to install it, fit the covers, and carry out future servicing. Consider the gate leaf’s weight and length, resistance to movement, number of cycles, and the condition of the track.
| Gate leaf length | Maximum cycles/hour | Maximum consecutive cycles |
|---|---|---|
| Up to 4 m | 35 | 14 |
| Over 4 m up to 6 m | 23 | 11 |
| Weight | Share of the stated number of cycles | Maximum recommended speed |
|---|---|---|
| Up to 200 kg | 100% | V6 – extremely fast |
| Over 200 kg up to 400 kg | 50% | V5 – very fast |
Example: for a 5 m / 350 kg gate, the maximum is 11 cycles per hour and 5 consecutive cycles, at a maximum speed of V5. One cycle consists of opening and closing. At high temperatures, the limiter may allow fewer movements.
When choosing a drive, allow at least a 50% force reserve: starting resistance should be less than half the maximum force, and resistance while moving should be less than half the rated force. For this motor, that means approximately under 200 N at startup and under 100 N while running. This refers to resistance to movement, not the gate’s weight in kilograms.
What’s included with the drive and what you need to add
The NKSL400 includes a motor with an M4, 15-tooth pinion and built-in NKA3R10. The outer post, cut-out covers, toothed rack, and safety accessories are selected according to the gate. Choose the receiver and remote controls to match the specific package.
The control unit supports automatic closing and closing after photocell activation, separate OPEN/CLOSE inputs and step-by-step operation, as well as adjustable partial opening, force, and speed. The temperature sensor adjusts the force control for cold conditions. Manual release works even when the power is off. Two opposing gates can be synchronised in Master/Slave mode.
The NKSL400 has its own installation procedure and method for setting the internal limit switches.
Drive accessories
| Item | Use |
|---|---|
| BlueBUS photocells | NICE EPMB or NICE EPSB – slim version. Two-wire power and communication with no polarity; devices must be scanned after any changes. |
| Flashing light | NICE ELDC for the low-voltage FLASH output. The mains-powered ELAC flashing light is not suitable for this output. |
| Radio control | NICE OXIBD for the SM socket, and compatible controls. The remote control type and coding must match the receiver. |
| Toothed rack | M4 nylon rack with metal reinforcement. The gate’s weight must not rest on the pinion. |
| Remote release | NICE KIO together with the cable NICE KA1, 6 m. Make sure the release can be accessed even when the gate is closed. |
| Backup for power outages | NICE PS124 is optional. The number of emergency movements depends on the gate, charge level, and battery condition. |
Drive dimensions and required internal clearance
The motor dimensions are 131 × 135 × 405 mm. The post must have a clear internal cross-section of at least 140 × 140 mm. One example is to use 150 × 150 × 4 mm profile; check the actual internal clearance, welds, and installation clearances before fabrication. See also the post cutout drawing.
Post cutout drawing
The front has a Ø 70 mm opening for the pinion and fixing holes. The rear requires a rectangular service opening measuring 520 × 134 mm. Prepare the side openings according to the selected release side. Take the dimensions of all openings from the drawing.
The internal dimension of the recommended bent cover is 151 mm. Seal the top of the post against water; cover the rear service cutout. The post and gate must be connected to protective earth. The IP44 rating applies only to a correctly completed assembly motor + post.
Installation and rack
Disconnect the mains supply and battery before carrying out any work. The gate must move smoothly by hand along its entire travel and must not derail or move on its own.
- Install solid opening and closing stops and check the post structure. Before inserting the motor, set the released gate leaf approximately halfway along its travel.
- Fit the release cover with the screw and washer. If you need to support the motor while inserting it, use the two supplied temporary screws D in the lower post slots, as shown in the illustration.
- Insert the motor through the rear opening, position it, and secure it with two upper M8 screws (F). Then remove the temporary screws D and only then install the two lower M8 screws (G).
- The motor height can be adjusted by 5 mm. Adjust the triangular release pin to suit the post width, check its fit by inserting the key, and secure it with the nut against the flat side of the pin as shown in the drawing.
- When installing a new rack, open the gate at least 50 cm away from the closed stop. Align the rack with the pinion and secure it to the gate leaf.
- Maintain a 1–2 mm gap between the rack and pinion teeth along the entire travel. The gate’s weight must not rest on the pinion.
- Fully open and close the released gate by hand. The rack and pinion may be misaligned by no more than 5 mm; the gap between the teeth must remain 1–2 mm along the entire travel.
Manual release
Stop the gate and disconnect the power supply before releasing it. Hold the gate leaf to prevent unintended movement. Slide back the lock cover, insert the key, and turn it 90° clockwise. The gate can then be moved by hand.
After moving the gate manually, return the release mechanism to the locked position and check that the drive has engaged before issuing an automatic command. Access can be prepared on either side of the post or remotely using KIO and KA1.
Preparing the electrical cables
| Cable run | Cable / length |
|---|---|
| 230 V AC mains supply | 3 × 1.5 mm² up to 30 m; for longer runs, 3 × 2.5 mm² and protective earth as required for the specific installation. |
| FLASH | 2 × 0.5 mm², maximum 20 m. |
| BlueBUS | 2 × 1.5 mm², maximum 30 m. Assess longer cable runs separately. |
| Antenna | RG58 coaxial cable, maximum 20 m; under 5 m recommended. |
| Key switch | 2 × 2 × 0.5 mm² or 1 × 4 × 0.5 mm², maximum 50 m. |
| Safety edges | 2 × 0.5 mm² up to 30 m; for a moving edge, use a suitable transfer system or flexible cable. |
Allow extra length on supply cables and secure them against tension. Water and condensation must not enter the electronics through the conduit. Mains and low-voltage cables must be installed in accordance with the electrical design.
NKA3R10 wiring diagram and accessory polarity
The wiring and settings below apply to a control board marked BlueBUS, STOP, SbS, OPEN, CLOSE and AUX_IN, with eight LEDs L1–L8 and three buttons. For an older control board, compare the terminal markings with its own manual; the AUX_IN additional input cannot be added by connecting it to another terminal.
| Terminal | Function and polarity |
|---|---|
| FLASH | For up to two ELDC flashing lights or up to two 12 V / 21 W bulbs. Do not use a mains-powered ELAC light. Follow the markings on the connected flashing light. |
| OGI | Programmable output, 24 V DC −30/+50%, maximum 4 W. Function set via second-level L4; factory setting responds to radio output 3. |
| BlueBUS | Compatible devices connected in parallel using two wires, with no polarity (+/−). Maximum 15 BlueBUS units. |
| STOP | Learned input: NO, NC, or 8.2 kΩ. A change from the learned state stops movement and briefly reverses it. The contact itself has no polarity. |
| SbS / OPEN / CLOSE | Voltage-free NO contact: step-by-step / open / close. CLOSE can be switched to partial opening. |
| AUX_IN | Voltage-free NC contact; factory-set function: STOP. The Oview programmer can be used to change the function. |
| Accessory power supply | Right STOP contact = −, left SbS contact = + as shown in the detail below. 24 V DC −30/+50%, maximum 100 mA for all devices powered this way combined. |
| Antenna | Coaxial cable: core to the signal terminal and shield to the corresponding terminal. These are not the power supply +/− terminals. |
| SM receiver / IBT4N | Radio receiver socket / BusT4 interface for Oview. Insert with the power disconnected. |
Do not confuse the auxiliary power terminals with the pair of terminals for the command itself. Do not apply external voltage to the inputs. For a resistive safety edge, follow the wiring instructions and fit the 8.2 kΩ termination resistor as specified in its manual.
Photocells and safety devices
NICE EPMB and NICE EPSB are two-wire BlueBUS photocells. Connect TX and RX in parallel to BlueBUS; polarity does not matter. The same pair must use the same jumpers; different pairs must have different addresses.
| Address | Response / application |
|---|---|
| PHOTO / PHOTO II | Outer pair at approximately 50 / 100 cm; stops and reverses movement while closing. |
| PHOTO 1 / PHOTO 1 II | Inner pair at approximately 50 / 100 cm; stops and reverses movement while closing. |
| PHOTO 2 / PHOTO 2 II | Protection during opening; position according to the area being protected. |
| PHOTO 3 | Pair covering the entire automated system. When used with PHOTO II, position TX/RX relative to each other as specified in the photocell manual. |
Photocells and safety edges must be positioned to cover the hazards associated with the specific gate, including the area behind the open gate leaf. After each wiring or addressing change, repeat device learning and functional tests.
Limit switches and initial startup
- Mechanical setup: the motor must be secured beside the gate, with the gate approximately halfway along its travel. With the gate leaf released, open it fully and close it fully to preset the internal limit switches. Return it to the halfway position and engage the drive.
- Direction: with the power disconnected, set the selector according to the opening direction—left or right. When powered on, BlueBUS should flash once per second, the TX/RX LED should flash, and FLASH/OGI should remain off.
- Device learning: press and hold OPEN + STOP/SET. When L1/L2 flash rapidly, after approximately 3 seconds, release the buttons. Wait until the process finishes; STOP must be lit and L1/L2 must go out.
- Travel learning: press and hold CLOSE + STOP/SET and release when the gate starts moving, after approximately 3 seconds. The first movement must be opening. If it starts closing, press STOP/SET, disconnect the power, correct the direction selector setting, and repeat the learning procedure.
- Allow the gate to complete a full opening cycle to the limit switch, followed by a full closing cycle. Do not interrupt the travel; if an error occurs, check the wiring and safety devices.
Fine adjustment of the end positions
Remove the cover from the two adjustment knobs. Select the knob with the arrow for the relevant end position and adjust it in small increments. Half a turn corresponds to approximately 3 cm of gate travel. After adjustment, issue a new command in that direction and check that the gate stops correctly.
During testing, the gate leaf should slow down before reaching the end position and stop approximately 2–3 cm before the fixed mechanical stop. Check rack clearance, the stability of the fixings, operation of the photocells and safety edges, and measure impact forces. The system may be operated only after the complete assembly has been tested.
First-level settings – enable / disable
The following settings apply to the NKA3R10 control board with OPEN, STOP/SET and CLOSE buttons and L1–L8 LEDs. All first-level functions are OFF by default.
- Hold STOP/SET until L1 starts flashing.
- Use OPEN/CLOSE to select the function LED.
- Press STOP/SET briefly to change the state: short flash = OFF, long flash = ON.
- After 10 seconds without a button press, the setting is saved and programming ends.
| LED | Function | When enabled |
|---|---|---|
| L1 | Automatic closing | After opening, the set pause time is counted down; the default is 30 seconds. |
| L2 | Close after photocell activation | Closes 5 seconds after the photocell beam is cleared. With L1 off, the gate opens fully first; with L1 on, opening may stop once the beam is cleared. STOP interrupts this function. |
| L3 | Always close | After power is restored, closes an open gate after a 5-second warning flash. |
| L4 | Standby | After 1 minute without movement, switches off BlueBUS and the LEDs, except for the slow BlueBUS flashing. A command restores operation. |
| L5 | Boost | Skips the gradual acceleration phase and starts at full power. |
| L6 | Pre-flashing | The warning light starts flashing 3 seconds before movement. |
| L7 | CLOSE as partial opening | Changes the function of the wired CLOSE input. |
| L8 | Slave | Second motor for synchronised opposing gate leaves. |
Second-level settings
Hold STOP/SET until L1 flashes, then use OPEN/CLOSE to select a parameter. Hold STOP/SET again; after approximately 3 seconds, the current value is displayed. While holding STOP/SET, use OPEN/CLOSE to select the desired value, then release STOP/SET. It is saved after 10 seconds of inactivity. Bold values are the factory settings.
| Parameter | Values L1–L8 |
|---|---|
| L1 – pause | L1: 5 s; L2: 15 s; L3: 30 s; L4: 45 s; L5: 60 s; L6: 80 s; L7: 120 s; L8: 180 s. |
| L2 – step-by-step operation | L1: open–stop–close–stop; L2: open–stop–close–open; L3: open–close–open–close; L4: apartment-block mode; L5: apartment-block mode 2 (command longer than 2 s = STOP); L6: step-by-step mode 2 (command shorter than 2 s = partial opening); L7: hold-to-run; L8: semi-automatic opening/closing by holding the command. |
| L3 – speed | L1: very slow; L2: slow; L3: medium; L4: fast; L5: very fast; L6: exceptionally fast; L7: fast opening / slow closing; L8: exceptionally fast opening / fast closing. |
| L4 – OGI output | L1: gate-open indicator; L2: active when closed; L3: active when open; L4: radio output 2; L5: radio output 3; L6: radio output 4; L7: service indicator; L8: electric lock. Voltage remains 24 V DC −30/+50 %, max. 4 W. |
| L5 – force | L1: exceptionally light; L2: very light; L3: light; L4: medium; L5: medium-heavy; L6: heavy; L7: very heavy; L8: exceptionally heavy gate. The value must be verified by force testing. |
| L6 – partial opening | L1: 0.5 m; L2: 1 m; L3: 1.5 m; L4: 2 m; L5: 2.5 m; L6: 3 m; L7: 3.4 m; L8: 4 m. |
| L7 – service interval | L1: automatic, based on load; L2: 1,000; L3: 2,000; L4: 4,000; L5: 7,000; L6: 10,000; L7: 15,000; L8: 20,000 cycles. |
| L8 – last errors | L1: last cycle; L2–L8: progressively older cycles. Used to read the history. |
Force adjustment does not compensate for a binding guide or an obstruction. After changing the force or speed, recheck safety and measure impact forces. For gates weighing over 200 kg, observe the V5 maximum speed limit.
Receiver and remote controls
The control unit has an SM connector for a receiver, for example NICE OXIBD. With the standard assignment, output 1 means step-by-step operation, 2 partial opening, 3 opening, and 4 closing. Era One, Era Inti or other NICE remote controls select according to compatibility with the installed receiver; its own instructions specify how to pair and delete remote controls.
For the OXIBD, connect the external antenna directly to the receiver, to the terminals for the coaxial cable's core and shield. The control board antenna terminal shown in the diagram for the older receiver is not a substitute. Insert the receiver and connect the antenna with the power disconnected.
Two opposing gate leaves – Master / Slave
Each gate leaf requires its own NKSL400. One motor remains Master; on the other, enable L8 Slave. The BlueBUS connection between the motors must preserve contact 1 Master → 1 Slave and 2 Master → 2 Slave as shown in the original detail. These numbers specify the contact order; they are not universal +/− terminals. BlueBUS photocells still do not require polarity.
- With the power disconnected, install and interconnect the motors, then set opposite opening directions.
- Connect the receiver and shared control and safety devices to the Master as shown in the diagram. The Slave may have its own FLASH, OGI, STOP and SbS, controlling only its own gate leaf.
- After powering on, set L8 to ON on the Slave. First run device learning on the Slave, then on the Master.
- Start learning the travel limits of both gate leaves on the Master. Test every safety device and the coordinated operation.
OPEN, CLOSE and AUX_IN are not used on the Slave. For backup power, each motor requires its own battery. The Slave's individual force and signal settings may differ.
Diagnostics via flashing beacon
If a fault occurs, count the short flashes: the sequence repeats after a pause of approximately 1 s. Normal flashing during movement is approximately 0.5 s on / 0.5 s off.
| Count | Meaning and checks |
|---|---|
| 1 | BlueBUS: devices do not match the learned configuration. Check the cable, addresses and any changes to the setup. |
| 2 | Photocell triggered: obstruction, dirt or incorrect alignment. |
| 3 | Force limiter: obstruction or increased friction. Check the mechanics first. |
| 4 | STOP activated. Check the safety circuit. |
| 5 | Internal parameter error. Wait at least 30 s and try a command; if the problem recurs, contact service. |
| 6 | The maximum number of cycles per hour has been exceeded. Let the drive rest. |
| 7 | Internal circuit error. Disconnect all power sources; if the problem recurs, contact service. |
| 8 | A continuous command blocks further commands; check, for example, the OPEN timer. |
| 9 | Automation locked by the automation STOP command; it requires the corresponding electronic unlock command, not just a mechanical key. |
| BlueBUS once per second | Normal operation; two quick flashes confirm an input change or a command received. |
|---|---|
| STOP lit | The learned safety input is in its permitted state; if the light goes out, it has been triggered. |
| L1/L2 flash together | Device learning is required. |
| L3/L4 flash together | Travel-limit learning is required. |
| AUX_IN off | For the basic function, the NC contact is open; check the circuit. |
| Remote control not responding | Check the battery and that it is paired with the correct receiver. If BlueBUS is not flashing either, check the power supply and fuses. |
The last eight errors can be read using second-level parameter L8: while holding STOP/SET, use OPEN/CLOSE to select the relevant cycle, then count the flashes. Do not bypass safety circuits.
Estimated service life
Calculate the indices for the specific gate and operating conditions. On the graph's horizontal axis, find the total percentage; read the estimated number of cycles from the vertical axis. The graph assumes regular maintenance; it is neither a guarantee nor a number of years.
| Characteristics of the complete automation system | Index | Service life graph |
|---|---|---|
| Length | Under 3 m: 0%; 3–4 m: 5%; 4–5 m: 10%; 5–6 m: 20%. | |
| Weight | Under 200 kg: 0%; 200–300 kg: 15%; 300–400 kg: 30%. | |
| Temperature / humidity | Above +40 °C or below 0 °C, or humidity above 80%: 20%. | |
| Dust, sand or salt | 15%. | |
| Force set to level 4 | 15%. |
Maintenance and backup
Carry out servicing no later than 6 months or 20,000 operations after the previous maintenance, whichever comes first. Also take into account any earlier alert set via L7. Check for corrosion, inspect the fasteners, pinion, rack, manual operation, limit switches and safety devices, and repeat the tests.
Disconnect the mains power and backup battery before servicing. PS124 is connected only after installation and programming are complete, as it can power the device even when the mains supply is off. The drive has a dedicated space for the battery. The user must keep the gate path and photocell optics clean; in the event of a fault or unusual operation, stop using the automatic controls. Keep children and other people away from the moving gate.
NKSL400 technical specifications
| Power supply, system / motor | 230 V AC, 50/60 Hz / 24 V DC |
|---|---|
| Current draw / power consumption | 1.1 A / 250 W |
| Maximum peak power consumption | 330 W |
| Maximum / rated force | 400 N / 200 N |
| Maximum / rated torque | 12 Nm / 6 Nm |
| Speed | Up to 0.34 m/s unloaded; 0.18 m/s at rated torque. |
| Maximum continuous operating time | 10 minutes at rated torque; cycle limits based on gate length and weight also apply. |
| Rack drive | M4, Z15 pinion |
| Dimensions / weight | 131 × 135 × 405 mm / 6.5 kg |
| Protection rating of the completed assembly | IP44, when the post is correctly installed and covered |
| Operating temperature | −20 to +50 °C |
| Insulation class | I – protective earthing is mandatory. |
| Backup | Optional PS124; operation during a power outage depends on the condition of the battery and gate. |
360° view
Installation manual PDF
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]