Garage door opener kit for doors up to 11.4/12.6 m² NICE SPIDER800
| Product availability: | within 7 days | We usually dispatch goods within 7 days. |
|---|
within 7 days
€263.21 including VAT
| Weight |
|---|
| 10 kg |
Description of Garage door opener kit for doors up to 11.4/12.6 m² NICE SPIDER800
- sectional garage doors up to a height of 2,6 m and an area of 11.4 m²,
- protruding up-and-over garage doors up to a height of 3 m and an area of 12.6 m²
| The kit includes: | NICE-SPIDER800 | |||
|---|---|---|---|---|
![]() |
1 × | NICE SPIDER800 Drive | ||
|
NICE SPIDER800 electromechanical drive for sectional garage doors with an area of up to 11.4 m², or protruding up-and-over garage doors with an area of up to 12.6 m². The motor is supplied with an integrated control unit and receiver. |
||||
![]() |
1 × | NICE MYGO4 Remote Control | NICE-MYGO4 | |
|
Four-button remote control for operating an automatic gate remotely. Use it to control four devices or send one device four different commands. |
Detail |
|||
| 1 × | SR32B belt rail, 3.2 m | NICE-SR32B | ||
|
Pre-assembled belt rail SR32B with a length of 3.2 m. For sectional doors, approximately up to 2.6 m; for up-and-over doors, the limit varies depending on the construction. See the compatibility table. |
Detail |
|||
![]() |
1 × | NICE SPIDER800 Installation Manual | ||
|
Installation manual for a successful installation, with illustrative wiring diagrams and instructions for programming and pairing the remote controls. |
Download |
|||
| 1 × | Installation accessories | |||
|
Screws for attaching the drive to the rail, mounting brackets, emergency release cord, etc. |
||||
NICE SPIDER800 is a garage door opener kit with an SR32B 3.2 m rail and one MYGO4 remote control. It has a built-in MCU1 control unit and radio receiver. The kit is powered by 230 V AC.
The belt rail, reinforced with steel cables, ensures quiet operation. The control unit learns the end positions, force and slowdown settings, and detects obstacles. In the event of a power failure, the door can be released using the cord and operated manually.
Accessories and control
Choose safety devices according to the actual risks posed by the garage door. The opener’s obstacle detection does not replace photocells, a safety edge or force measurement when commissioning the installation.
| What | Why | Type |
|---|---|---|
| Control unit | Opener setup, operation and servicing; the control board is built in. | |
| Rail | The opener moves a trolley with an arm and requires a compatible belt drive rail. |
|
| Taller door | Choose a rail extension according to the door type, height, area and resistance. | |
| Up-and-over door | Up-and-over doors with counterweights require a suitable arm geometry. |
|
| Photocells | Obstacle detection in the protected area. Choose the correct electrical interface. | |
| Warning light | Visible indication of door movement; may also include an external antenna. | |
| Remote control | The receiver is built in. The remote control must be stored in the receiver’s memory. | |
| Backup power supply | Enables operation during a power outage when a battery is added. | |
| Service settings | Diagnostics and advanced settings via BusT4. |
SPIDER800 kit contents
This listing offers the SPIDER800 kit with an SR32B rail and one MYGO4 remote control. The package contents are listed in the kit table above. Photocells, a warning light, backup power and the SPA5 arm are ordered as needed; they are not automatically included in every kit.
| Kit with rail |
|---|
NICE SPIDER800![]() 800 N; SR32B + 1 × MYGO4. Sectional doors up to 11.4 m². |
Which garage door is the opener suitable for?
With the standard rail SR32B approximate dimensions depend on the type of garage door. The dimensions in the table are width × height. Suitability also depends on balance, friction and installation space.
| Door type | Approximate dimensions | Condition |
|---|---|---|
| Sectional | 4.4 × 2.6 m | Approximately 11.4 m². |
| Non-protruding up-and-over | 4.2 × 2.4 m | SPA5; area 10.08 m². |
| Protruding up-and-over | 4.2 × 3.0 m | SPA5; area 12.6 m². |
| Spring-assisted up-and-over | 4.2 × 3.0 m | Depending on the installation, without SPA5; check the track and balance. |
Maximum force 800 N indicates the drive's pulling force. It is not the gate's weight in kilograms. During the test with the gate disengaged the force required to move it manually in either direction along the entire travel must not exceed 225 N. The drive must not be used as a substitute for repairing damaged springs or an incorrectly balanced gate.
The SR32B rail is 3.2 m long, with a carriage travel of 2.8 m. The gate height also depends on its construction and the arm. For a taller gate, you can add an SR08B extension, 0.8 m long, with a longer belt; with a 4 m track, the useful travel is 3.5 m. The extension alone does not confirm that a larger or heavier gate is suitable. Send us the width, height, gate type and required travel via contact.
Cycles and load
One cycle is one complete opening and closing. The table shows maximum values by height; gate resistance reduces them further. The overall limit of 50 cycles/day also applies, as does a maximum of 4 minutes of continuous operation.
| Gate height | Cycles/hour | Consecutive |
|---|---|---|
| Up to 2 m | 20 | 10 |
| Over 2 m up to 2.5 m | 15 | 7 |
| Over 2.5 m up to 3 m | 12 | 5 |
| Over 3 m up to 3.5 m | 10 | 4 |
For a force of up to 250 N required to move the gate, the manufacturer specifies a 25% reduction in the number of cycles; at 250–400 N, the reduction is 42%. This load calculation does not increase the permitted resistance during the manual movement test: the limit remains 225 N maximum. The thermal limit may temporarily prevent further operation; allow the drive to cool down.
Installing the rail and drive
Install with the gate closed and both the mains supply and backup battery disconnected. The gate must move smoothly by hand and remain balanced in each position when disconnected from the carriage. Resolve any locks that would prevent automatic movement before installation. Springs and counterweights must be adjusted by a qualified technician.
- Check the clearance above the gate, rail length, and the strength of the wall and ceiling. Keep the drive and release cord accessible.
- For a two-piece track, slide both sections into the connector as far as they will go. With the assembled SR32B this joining step is not required. Check that the carriage moves freely and continuously.
- Fit the motor head onto the rail and secure it with the supplied screws. The head may also be rotated 90° relative to the track axis, as shown in the installation drawing.
- Adjust the belt tension. An overtightened belt can damage the drive; a loose belt causes noise and unreliable movement. When using an extension, fit the correct longer belt.
- Secure the front bracket to a sufficiently strong substrate and suspend the rear section from the ceiling brackets. Align the track and tighten all fasteners.
- With the gate closed, disengage the carriage, fit the gate bracket in line with the rail, and connect the drawbar. A thin panel must be suitably reinforced; the installation must withstand the drive force without deforming.
- Complete the release cord installation. Manually move the gate through its full travel, check the clearances, and re-engage the carriage before programming.
In the orientation shown:
- A = 40–400 mm
- B = 0–400 mm
- C = 3 158 mm
- D = 395 mm.
For an up-and-over gate, maintain E = 65–300 mm, the clearance between the track and the highest point of the gate's top edge as it moves. The dimensions apply to the installation arrangement shown.
Wiring and mains power supply
Use a protected socket 230 V AC, 50/60 Hz with a protective earth conductor and a means of safely disconnecting the power. Do not cut off the supplied cable or plug. If a suitable socket is not available, arrange for one to be installed with the necessary protective devices. Route low-voltage wires separately from the mains wiring and secure them against pulling and contact with moving parts.
| Connection | Cable / maximum length |
|---|---|
| Flashing light | 2 × 0.5 mm²; maximum 20 m. |
| Antenna | Separate RG58 coaxial cable; maximum 10 m, less than 5 m recommended. |
| Push button / key switch | 2 × 0.5 mm² for a voltage-free NO command; maximum 50 m. For two contacts, use two 2 × 0.5 mm² cables or one 4 × 0.5 mm² cable. |
| Photocells | BlueBUS: 2 × 0.7 mm², TX and RX in parallel. Relay type: RX 4 × 0.5 mm², TX 2 × 0.5 mm². Maximum 30 m. |
| Safety edge | 2 × 0.5 mm²; maximum 20 m. OSE requires three wires, according to the safety edge wiring. |
| Mains supply to the socket | 3 × 1.5 mm² for up to 30 m; for longer runs, use 3 × 2.5 mm² as specified in the installation manual, and provide protective earthing at the automation unit. |
The specified lengths apply to the relevant wiring configuration and environment. For a different safety edge or control module, also follow the instructions for that device. Do not connect mains power to the accessory inputs.
Control board, terminals and polarity
The SPIDER800 has a built-in MCU1 control unit with BlueBUS and L1–L8 programming LEDs.
| Terminal | Function and connection |
|---|---|
| 24 V / GND | 24 V is positive (+), GND is negative (−). Auxiliary 24 V DC power supply, tolerance −30% / +50%, 100 mA maximum total. |
| BlueBUS | Two-wire power supply and communication for compatible devices; EPMB are connected in parallel. No +/− polarity. |
| PHOTO | Normally closed (NC) dry contact between PHOTO and 24 V (+). Power the relay photocells separately from 24 V (+) / GND (−). |
| SbS | Normally open (NO) dry-contact button between SbS and 24 V (+); a brief closure sends a step-by-step command. |
| STOP / GND | STOP safety input referenced to GND. NO, NC or 8.2 kΩ type is learned at startup. The contact itself is not polarity-sensitive. |
| 12 V OSE / STOP / GND | Optical safety edge: 12 V OSE = positive (+), STOP = signal, GND = negative (−). 12 V DC power supply, maximum 15 mA. Connect only a suitable OSE edge, following its instructions. |
| FLASH / OGI | Separate two-pole outputs, 24 V DC as standard, maximum 10 W per output. FLASH for the warning light, OGI for the open-gate indicator. The function depends on the settings. |
| AERIAL | Coaxial antenna input: connect the centre conductor and shield according to the diagram; this is not an accessory power supply. |
Push button, key switch or relay
Connect only a normally open (NO) dry contact, such as a push button or a control-module relay. The contact connects SbS and 24 V (+). Do not apply the module's output voltage to the command input. If the module needs power, use the separate 24 V (+) and GND (−) and observe the 100 mA total limit.
Safety edge and STOP input
STOP halts movement and briefly reverses it. When changing a safety device, you must run the device-learning procedure again. Connect multiple NO contacts in parallel and NC contacts in series. Wire 8.2 kΩ edges and their combinations according to the specific diagram; a standard switch does not provide the same fault monitoring as a monitored edge.
Photocell wiring
For simple two-wire wiring, choose NICE EPMB with BlueBUS. Connect both wires from TX and RX in parallel to the BlueBUS pair. This bus has no polarity; the 24 V (+) / GND (−) markings apply to other terminals.
- With the power disconnected, set the same jumper address on TX and RX of each pair. Each additional pair must have a different address.
- Secure and align TX with RX, then connect BlueBUS. Choose the function and installation height according to the area being protected.
- After wiring or changing addresses, perform device learning and a separate safety test.
| Address | Position and response |
|---|---|
| PHOTO / PHOTO II | Inner photocell at a height of 50 / 100 cm; stops and reverses movement during closing. |
| PHOTO 1 / PHOTO 1 II | Outer photocell at a height of 50 / 100 cm; stops movement during opening and closing, then resumes opening when the beam is clear. |
| PHOTO 2 / PHOTO 2 II | Inner protection active during opening; position as shown in the drawing. |
| PHOTO 3 | Protection during opening and closing; select according to the actual risk and position. |
Do not place pairs with the following addresses next to each other: PHOTO / PHOTO 2, PHOTO II / PHOTO 3, PHOTO 1 / PHOTO 2 II, to prevent them from interfering with each other. Photocells used as an opening command do not replace a safety pair.
Relay photocells on PHOTO
With EPM without testing: on both TX and RX, 1 = positive, 2 = negative. Power them from terminals 24 V (+) and GND (−). On RX, use 4 – COM and 5 – NC between 24 V (+) and PHOTO. Terminal 3 is NO and is not used for the PHOTO safety input. The total current draw from the auxiliary power supply must not exceed 100 mA.
Relay photocells with PHOTOTEST
For tested wiring, power TX from the OGI, while RX remains connected to 24 V (+) / GND (−). With the board oriented exactly as shown in the diagram below, the upper OGI terminal is negative (−), and the lower one is positive (+). On EPM, terminals 1 (+) and 2 (−); RX terminals 4 – COM and 5 – NC connect between 24 V (+) and PHOTO. OGI provides 24 V DC, max. 10 W. Do not confuse these wires with the FLASH output.
Set level II/L5 to value LED L2 – PHOTOTEST and relearn the devices. Before movement, the control unit tests the photocells; if the test fails, the manoeuvre is blocked. This relay-based procedure is not used with BlueBUS EPMB.
FLASH beacon, lighting and antenna
NICE ELDC connect it using its terminal block marked FLASH to the FLASH pair on MCU1; the standard output is 24 V DC, max. 10 W. The output function must be set accordingly in programming. Do not connect a 230 V mains beacon to these terminals.
For the FLASH pair on the beacon, follow the markings on the connected device. The polarity is not marked on this ELDC detail; do not apply the orientation of the auxiliary 24 V / GND terminal block to it. The AERIAL input on the ELDC is a separate antenna: connect the coaxial cable to the control unit’s antenna connector as shown. Do not confuse the antenna with the beacon power supply.
The drive also has built-in LED garage lighting. The OGI output is also intended for external open-gate indication; if you change its function, check the OGI setting and load.
Initial startup and learning
First complete the mechanical installation and wiring, secure the carriage, and clear the entire travel area. Check STOP, the photocells and the direction of travel. Position learning, force learning and remote-control pairing are separate operations.
Before switching on for the first time, place the secured gate approximately halfway along its travel. With a new, unconfigured control unit, 4 red BlueBUS flashes are a normal warning that configuration is missing. The beacon and interior light should be off at rest; for a standard installation, set the direction selector to the left.
1. BlueBUS and STOP learning
- Switch on the power. On first startup, L1 and L2 flash; perform recognition even if no accessories are connected.
- Press and hold OPEN + STOP/SET for approximately 3 s. Release when L1 and L2 start flashing rapidly.
- Wait for the process to finish. STOP should be lit, and L1 and L2 should go out. On first installation, L3 and L4 start flashing: the positions must be stored.
If changing direction using the rotary switch on the board, set it with the power disconnected according to the drive layout, then relearn the devices. The direction change takes effect only after this learning process; do not change direction by swapping the safety accessory wires.
2. Storing the open and closed positions
- Press and hold STOP/SET + CLOSE for approximately 3 s. L1 starts flashing.
- Use OPEN / CLOSE to set the required fully open position. Press and hold STOP/SET for 3 s; L1 lights up and the open position A1 is stored. Release.
- While L8 is flashing, move the gate with OPEN / CLOSE to its fully closed position at floor level. Press and hold STOP/SET for 3 s; L8 lights up. Release; the programming LEDs go out.
- Send an SbS or OPEN command. The drive performs a complete automatic force-learning cycle.
The time limit for each step involving a movement command is 60 s; if this limit is exceeded, start the position-setting process again. The control unit calculates intermediate positions, deceleration and partial opening; these can be adjusted in more detail through the service interface.
Force learning and the first movement test
Force learning runs an automatic opening and closing manoeuvre at increased force.. Keep people and objects clear of the gate during this process. Flashing interior lighting indicates that learning is in progress. Force learning must be repeated after changing the positions, speed, direction or mechanical relief setting.
If the process is interrupted by STOP, a photocell or a power failure, resolve the cause and resume learning with another SbS / OPEN / CLOSE command.
Pre-commissioning test
- With the carriage disengaged, check manual opening and closing along the entire travel: the required force must not exceed 225 N (approximately 23 kgf, not the weight of the gate). Then re-engage the carriage.
- Repeat powered opening and closing; the gate must reach the stored positions without binding or deforming the brackets.
- Check deceleration at the end positions, belt slack after stopping, manual release and re-engagement.
- Interrupt each photocell at the TX, at the RX and in the middle of the beam; check that the safety response is correct. Test all STOP devices.
- Measure impact forces and verify the safety of the entire gate. Do not use increased force to compensate for poor mechanics. Repeat the measurement after changing the force setting.
- Give the user instructions for operation, release and maintenance. Pass through only when the gate is fully open and stationary.
MCU1 programming
Use OPEN, STOP/SET, CLOSE and LEDs L1–L8 on the board. Program while the gate is stationary. During normal movement, pressing any button on the board sends a STOP command. A short flash of the selected function LED indicates OFF; a longer flash indicates ON. After changing the force or sensitivity, check the gate’s safety again.
Level I – ON / OFF functions
- Press and hold STOP/SET until L1 starts flashing, then release.
- Use OPEN / CLOSE to move the flashing LED to the desired function.
- Press STOP/SET briefly to switch ON / OFF. If needed, set another function.
- To save and exit, wait 20 s without pressing a button.
| LED – function | Meaning / factory setting |
|---|---|
| L1 – Automatic closing | ON: after opening, the gate closes after the pause set at level II/L1. OFF: waits for a command. Factory setting: OFF. |
| L2 – Close after photocell | ON: when the photocell is clear, a 5 s pause is applied. With automatic closing enabled, the gate may finish opening once the beam is clear; without it, the gate completes opening and closes after 5 s. STOP cancels this follow-up response. Factory setting: OFF. |
| L3 – Always close | ON: after power is restored, if the gate is detected open, it flashes for 5 s and closes. Factory setting: OFF. |
| L4 – Standby | ON: after 1 minute of inactivity, switches off some of the electronics; BlueBUS flashes slowly. Take the power requirements of connected devices into account. Factory setting: OFF. |
| L5 – Protection against unauthorised opening | ON: closes the gate if forced opening is detected. App notifications require a compatible interface and configuration. Factory setting: OFF. |
| L6 – Pre-flashing | ON: the warning light flashes for 3 s before movement begins. Factory setting: OFF. |
| L7 – Disable internal radio | ON: the internal receiver is disabled, for example when using an external OXI/OXIBD. OFF: the built-in radio is active. Factory setting: OFF. |
| L8 – Light / heavy gate | ON: preset for a light gate. OFF: preset for a heavy gate. Changes the group of force, sensitivity and speed values; force learning must then be performed. Factory setting: OFF. |
Level II – adjustable values
- Press and hold STOP/SET until L1 starts flashing; release.
- Use OPEN / CLOSE to select the parameter input LED.
- Press and hold STOP/SET. After approximately 3 s the LED for its current value lights up. Continue holding STOP/SET and use OPEN / CLOSE to select another value LED.
- Release STOP/SET. Set another parameter or wait 20 s without pressing any buttons to save and exit.
The factory-set value LED is shown in bold. The light/heavy gate preset or configuration via the service interface may change some values; the current indications on the control board take precedence.
| Input LED – name and description | Setting LED – value |
|---|---|
| L1 – Pause Automatic closing time; applies when I/L1 is ON. |
L1 – 5 s L2 – 15 s L3 – 30 s L4 – 45 s L5 – 60 s L6 – 80 s L7 – 120 s L8 – 180 s |
| L2 – Step-by-step command Sequence for the step-by-step input and the first radio command. Modes L4, L5, L7 and L8 also change the OPEN / CLOSE commands. |
L1 – open – stop – close – stop L2 – open – stop – close – open L3 – open – close – open – close L4 – shared input L5 – shared input 2; holding for more than 2 s = STOP L6 – step-by-step 2; holding for more than 2 s = partial opening L7 – movement only while the command is held L8 – semi-automatic opening, closing while the command is held |
| L3 – Speed Percentage of maximum speed. Force learning must be performed again after changing this setting. |
L1 – 30% L2 – 44% L3 – 58% L4 – 72% L5 – 86% L6 – 100% L7 – opening V4 (72%), closing V2 (44%) L8 – opening V6 (100%), closing V4 (72%) |
| L4 – FLASH (OUT1) The output function must match the load. Output: 24 V DC, max. 10 W. The lock, latch and magnet must be electromagnetic types without their own electronics. |
L1 – gate-open indicator L2 – active only when the gate is fully closed L3 – active only when the gate is fully open L4 – warning light during movement L5 – electric latch: active during opening; mechanically secured during closing L6 – electric lock: activated at the start of opening for the set time L7 – magnetic lock: active when the gate is fully closed; released before opening L8 – maintenance indicator |
| L5 – OGI (OUT2) Second output: 24 V DC, max. 10 W; phototest requires correct TX wiring and a new learning cycle. |
L1 – OGI open-gate indicator L2 – PHOTOTEST: TX power supply and check before movement L3 – gate status: active during movement, off when stopped L4 – garage lighting: follows the internal light L5 – radio channel 1 L6 – radio channel 2 L7 – radio channel 3 L8 – radio channel 4 |
| L6 – Motor force Adjustment values in %: opening / closing. This is not the force measured on impact. |
L1 – 60 / 30% L2 – 60 / 40% L3 – 70 / 40% L4 – 70 / 50% L5 – 80 / 50% L6 – 80 / 60% L7 – 90 / 70% L8 – 90 / 80% |
| L7 – Obstacle sensitivity Sensitivity levels for opening / closing; these are not newtons. |
L1 – off L2 – 10 / 20 L3 – 20 / 30 L4 – 30 / 40 L5 – 40 / 50 L6 – 50 / 60 L7 – 60 / 70 L8 – 70 / 80 |
| L8 – Mechanical relief A brief reversal releases tension once the gate reaches the closed position. Force learning must be performed after changing this setting. |
L1 – no relief L2 – minimum L3 – intermediate level 3 L4 – intermediate level 4 L5 – intermediate level 5 L6 – intermediate level 6 L7 – intermediate level 7 L8 – maximum |
If you assign a radio channel to the OGI output, it remains active while the corresponding radio command is being sent. That channel will then no longer perform its original motor command. This output function is not available for BD bidirectional transmitters.
If L1 and L8 flash simultaneously during setup, the current value is outside the range offered on the control board, for example after being set via the service interface. Check this setting or use the OPEN / CLOSE buttons to select a suitable value from the menu.
Remote controls and pairing
The receiver is built in. MYGO4 from the kit must be stored in memory. The MCU1 uses O-Code and BD and, in Mode 1, can store 100 transmitters; for any additional transmitter, check the encoding, not just the 433.92 MHz frequency.
Mode 1 – all buttons
- Hold RADIO until the green R LED lights up, then release it.
- Within 10 s hold any button on the one-way transmitter. Release it at the first of the three green flashes of R.
- With a bidirectional transmitter, press and immediately release the button; storage is confirmed by three green flashes of R and a short vibration from a compatible transmitter.
| Button in Mode 1 | Command |
|---|---|
| 1 | Step-by-step (SbS) command |
| 2 | Partial opening |
| 3 | Open |
| 4 | Close |
Mode 2 – one button
Press and release RADIO n times, according to the command number. The R LED will repeat the count. Within 10 s, store the selected transmitter button as described above; repeat the procedure for each additional button.
| Number of RADIO presses | Command |
|---|---|
| 1 | SbS |
| 2 | Partial opening 1 |
| 3 | Open |
| 4 | Close |
| 5 | STOP |
| 6 | SbS for shared input |
| 7 | High-priority SbS |
| 8 | Partial opening 2 |
| 9 | Partial opening 3 |
| 10 | Open and disable automation |
| 11 | Close and disable automation |
| 12 | Disable automation |
| 13 | Enable automation |
| 14 | Lighting – timer |
| 15 | Lighting – on/off |
On the MCU1, a high-priority button can also operate the automation when it is disabled. For normal operation, use SbS; select the lockout commands only when you need this function.
Adding a transmitter using an existing one
Carry out the procedure within range of the operator and only when learning is enabled. Applies to one-way transmitters.
- On the new transmitter, hold the desired button for 7 s and release it.
- On the original transmitter, slowly press and release the stored button three times.
- On the new transmitter, press and release once the same button as in the first step.
Erasing the radio memory
This erases all stored transmitters. Keep holding RADIO even after the R LED lights up and then goes out. When it flashes again, release exactly at the fifth flash. Five rapid flashes confirm successful erasure. Erasing the radio memory is a separate operation from resetting the control unit.
For bidirectional transmitters, also delete the stored pairing on the transmitter side, as described in its manual.
Erasing one transmitter or button
- Hold RADIO on the board until the green R LED lights up and then goes out. Release RADIO at that point; do not wait for the fifth flash as you would when erasing the entire memory.
- On the one-way transmitter, hold the stored button. Release it at the first of the five rapid green flashes of R.
- On the bidirectional transmitter, press and immediately release the button instead of holding it. Five rapid green flashes of R confirm erasure.
In Mode 1 you can use any button; the entire transmitter will be erased. In Mode 2 repeat the procedure for each stored button you want to remove.
Disabling remote learning
- Disconnect the mains and backup power, then wait 10 s. Hold RADIO and restore the power supply.
- After the stored transmitters are signalled, release RADIO immediately after the second short orange flash of R.
- Within 5 s, use short presses of RADIO to select the setting: R off = no lockout; red = learning disabled at the receiver; green = learning disabled by authorisation code; orange = both lockouts.
- Within 5 s, press a stored button on an already paired transmitter to save the selected setting.
Resetting the control unit
Resetting will clear the custom control settings. Hold OPEN + CLOSE for approximately 3 s, until L1–L8 light up; then release. Rapid flashing for 3 s confirms success. After resetting, repeat device learning, position learning and test the gate. This procedure does not erase radio codes in the built-in or external receiver.
Troubleshooting
FLASH indicates errors by the number of short flashes. The sequence repeats after a 1 s pause; count one sequence.
| Signal | Cause and next step |
|---|---|
| 1 flash | Closing / position The floor was not detected while closing. Reset the closed position. |
| 2 flashes | Photocells Remove the obstruction, check the alignment and photocell wiring. Activation when an obstruction is detected is expected. |
| 3 flashes | Force limitation Check manual movement, springs, obstructions and friction. Do not automatically increase the force; check the mechanics and safety. |
| 4 flashes | STOP Check the STOP safety device and any control unit lockout. |
| 5 flashes | Parameter memory Wait at least 30 s, then try issuing a command. If the error persists, book a service visit. |
| 6 flashes | Operation limit Wait a few minutes for it to cool down. Check the operating load and gate resistance. |
| 7 flashes | Internal electrical circuit Disconnect all power supplies for a few seconds. If the error persists, have a service technician check the board and motor wiring. |
| 8 flashes | Continuous command Remove the continuously active command, such as a stuck button or relay; check SbS. |
| 9 flashes | Automation stopped A command was issued to stop the automation. If the automation was locked using the corresponding radio command, restore it with the Unlock automation (command 13). |
| LED / indication | Meaning and check |
|---|---|
| BlueBUS – 2 green flashes/s | Normal operation. Two quick green flashes indicate an input change. |
| BlueBUS – fast and longer red sequences | Bus short circuit: with the power disconnected, check the cables. Once resolved, normal signalling resumes after approximately 10 s. |
| STOP off | STOP active; check the safety wiring. |
| PHOTO off | PHOTO relay input activated. |
| SbS on | Command present; if the button is not pressed, check the cables and relay. |
| L1 + L2 flashing | Device learning. |
| L3 + L4 flashing | Position learning. |
| Red light during movement | The set maintenance interval has been exceeded; carry out an inspection. |
| L1 to L8 light up in sequence | Firmware update: wait and do not disconnect the power supply. |
L1–L8 during movement: The number of lit or flashing LEDs indicates the motor's instantaneous load, from low at L1 to high at L8. This indication alone does not indicate a fault, nor is it an LED value for setting the motor force. If the load is unusually high, check for obstructions and inspect the gate mechanics.
Do not use the automation normally if a safety device is faulty. Safely release the gate and book a repair. Replace the fuse only with one of the same type and rating; do not bypass it.
PS124 backup battery
PS124 fits into the dedicated compartment in the drive unit and connects to the designated connector, as shown in the installation PDF. Connect it only after completing the mechanical installation, wiring and programming. The battery remains live even when the mains is disconnected: before working, disconnect both the mains and the PS124. The number of operations during a power failure depends on the battery condition, temperature and gate resistance.
Manual release and operation
Release the gate only when it is stationary. If a spring is faulty or the gate is unbalanced, it may drop uncontrollably when released; secure it and call a technician. If the garage can only be accessed through this gate, arrange in advance for an external release suitable for the specific gate.
- Pull release cord A. The trolley disengages, allowing you to move the gate safely by hand.
- To re-engage the trolley, pull cord A again as shown in the second illustration.
- Move the gate by hand until the lower and upper parts of the trolley align and engage. Check that the trolley is engaged before issuing an electrical command.
Maintenance and safe operation
Schedule an inspection no later than every 6 months or after 3,000 operations, whichever comes first. Disconnect all power sources before maintenance. Check the rail, belt, trolley, brackets, corrosion, springs and gate balance; replace worn parts. After the inspection, repeat the safety device and force tests.
Keep remote controls out of children's reach. Do not enter the gate's operating area while it is moving. If you notice unusual noise, jerky movement or worsening balance, stop operation and arrange a service visit. Take electronic equipment and batteries to an appropriate collection point, not to general waste.
SPIDER800 technical specifications
| Parameter | Value |
|---|---|
| Application | Electromechanical drive for residential garage doors. |
| Control unit | Built-in MCU1, BlueBUS and L1–L8 LEDs. |
| Mains power supply | 230 V AC ±10%, 50/60 Hz; protective conductor. |
| Maximum / rated force | 800 / 400 N. |
| Rated / maximum power input | 180 / 280 W. |
| Maximum speed | 0.20 m/s; actual operating speed depends on the settings and load. |
| Cycles/day | 50; also observe the other operating limits. |
| Continuous operation | Maximum 4 minutes. |
| Protection rating / temperature | IP40; −20 to +55 °C. |
| Head dimensions | 225 × 395 × 105 mm; see drawing for installation details. |
| Motor weight | 4.9 kg; not the weight of the complete kit. |
| Auxiliary accessories | 24 V DC, tolerance −30% / +50%, total max. 100 mA; polarity and terminals. |
| Backup | PS124 – optional. |
| Lighting | Built-in LED. |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]















