Wiring photocells to a NICE Robus RBS operator
Robus RBS operators use BlueBUS technology, so they are compatible with photocells that support this technology. Robus RBS also supports conventional relay photocells.
Photocells always come in pairs: a TX transmitter and an RX receiver. There are three types of photocell configurations:
- Both photocells are wired (TX transmitter and RX receiver). The most commonly used models are EPMB and EPSB, as well as EPLB, F210B, or the old, discontinued MOFB models.
- One wired photocell and one battery-powered wireless photocell. Model FT210B.
- Both photocells are wireless. Model EPMOW used with the IBW device.
Before connecting the photocells, disconnect the operator from the power supply. Once they are connected, restore power, run device recognition by holding the OPEN+STOP/SET buttons until the L1+L2 LEDs start flashing, then release the buttons.
BlueBUS photocells
The entire BlueBUS system is wired using two-core cables; the cable should be 2x0.5mm2. If you use network cables (FTP, UTP, STP, or any other twisted pair) for the connection, the cross-sectional area of each conductor is usually between 0.10 and 0.25 mm2. We therefore recommend doubling the wiring: use four conductors instead of two, in two pairs. Otherwise, you may get continuity on the cable and the photocell may flash, but still fail to work properly.
Wiring wired photocells
Connect the photocells in parallel to the BlueBUS input using two-core cables; polarity does not matter. You can connect both photocells directly to the control unit, or run a two-core cable from the control unit to one photocell, then another two-core cable from there to the next.
| Connecting both photocells to the control unit | Wiring from the control unit to one photocell and then to the other |
|---|---|
![]() |
![]() |
Wiring one wired and one wireless photocell
This configuration uses NICE FT210B photocells. Connect one photocell to the BUS (BlueBUS) terminal on the control unit using a two-core cable, and the other is battery-powered.
Wiring wireless photocells
Wireless photocells do not need wiring, since they are wireless. Only the IBW communicator needs to be wired; the photocells communicate with it wirelessly. For the wiring procedure, go to Wiring and programming the NICE IBW device with NICE EPMOW photocells.
Relay photocells
NICE Robus RBS operators also support conventional circuit wiring, so they are generally compatible with all 24V relay photocells.
The control unit has a PHOTOTEST function that improves the reliability of safety devices and enables the system comprising the control unit and safety photocells to achieve “Category II” under standard EN 13849-1.
Wiring relay photocells with the phototest function
To activate the PHOTOTEST function, configure the system using a compatible Wi-Fi interface and the MyNice Pro app.
At the start of each operation, the relevant safety devices are checked, and the operation starts only if everything is working correctly. If the test fails (for example, if sunlight blinds a photocell or the cables are short-circuited), a fault is detected and the operation will not proceed.
Wiring diagram for relay photocells with the PHOTOTEST function:
Wiring relay photocells without the phototest function
The control unit has a dedicated PHOTO input for connecting the normally closed contact of relay photocells. Unlike the “PHOTOTEST” configuration, the operation starts when commanded without checking whether the signal from the photocells is valid, but the system still responds to changes in the state of the external photocells.
Wiring diagram for relay photocells without PHOTOTEST: