Wiring a key switch to the NICE Robus RBS sliding gate operator



The key switch has two positions. You can turn the key either to the right or to the left. A spring inside the switch returns the key to the centre. The switch contains two microswitches, each with three terminals: NC, C and NO. You can wire just one side of the key switch, wire both sides, or leave it unwired altogether. It does not affect the operator’s operation; it is an optional accessory. You can wire each side of the key switch to either the STOP, SbS (Step by Step; step-by-step operation, formerly P.P., from the Italian passo-passo, meaning “step by step”), OPEN or CLOSE terminal.

Possible wiring configurations and functions:

  • STOP input Connect it to the microswitch in the key switch at terminals NC and C. Turning the key in this direction only stops the gate.
  • SbS (P.P.) input Connect it to the microswitch at terminals NO and C. Repeatedly turning the key in this direction cycles the gate up and down and stops it, depending on how the operator is programmed. The factory setting is as follows: with the gate closed, the first turn of the key starts opening it, the next turn stops it, the following turn starts closing it, and the next turn does not stop it but immediately starts opening it again. If the gate is fully open, turning the key closes it. This works the same way as repeatedly pressing the remote control.
  • OPEN input It is wired and works like SbS, except that it only opens the gate, stops it, then opens it again. Once the gate is open, it no longer responds.
  • CLOSE input This is the opposite of the OPEN input: it only closes the gate, stops it, then closes it again. When the gate is closed, it does not respond. This input can be reprogrammed for partial opening (pedestrian access).

Key switch wiring summary

The original manual shows the wiring to the STOP and SbS terminals: run a two-core cable from terminals NC and C on one microswitch to the STOP input on the control unit, and from terminals NO and C on the other microswitch to the SbS input on the control unit. This way, turning the key one way opens, closes or stops the gate, while turning it the other way only stops it. However, you can wire the key switch in any way you like.

Remember to disconnect the operator from the power supply before making any wiring changes. After changing the wiring and restoring power, detect the connected devices by holding down the OPEN+STOP/SET buttons until the L1+L2 LEDs start flashing, then release them.