Programming the functions of the NICE Robus RBS drive

Programmable functions of the NICE Robus RBS drive

NICE Robus RBS drives have 8 functions that can be switched on/off and 8 functions that can be set to 8 possible values. Programming is carried out using the three buttons OPEN, STOP/SET, CLOSE and eight LEDs, L1 to L8. The default values are set at the factory, so if you don't need to change anything, there's nothing to program. These functions are:

8 functions that can be switched on/off (level one programming)

All these functions are switched off at the factory, except one: L4 Standby mode for energy saving.

. On the control unit, you can check whether a function is enabled by looking at the corresponding LED, L1 to L8. Example: only automatic closing is enabled, so LED L1 on the control unit stays lit.

  • L1 - Automatic closing - enable this function if you want the gate to close automatically after the set time delay (the factory setting is 30 seconds; this function lets you change it to 5, 15, 30, 45, 60, 80, 120 or 180 seconds).
  • L2 - Close after photocell - enable this function if you want the gate to close 5 seconds after passing through the photocells. The gate always opens fully, even if you passed through it "a long time ago"; it then closes after 5 seconds.
  • L3 - Always close - enable this function so that the gate receives a close command after a power failure. Otherwise, it would remain open when power is restored.
  • L4 - Standby mode - enable this function when operating on a backup battery or solar panel. After one minute, the control unit enters "sleep" mode and wakes only when it receives a command to perform a manoeuvre. Although this function reduces power consumption, the control unit may not behave exactly as expected with complex wiring (GSM control, card readers, induction loops, timers, etc.). We therefore recommend leaving this function disabled unless you really need it. (Sleep mode is enabled at the factory.)
  • L5 - Boost (start-up) - when this function is enabled, the drive runs at full power from startup, which can eliminate false obstacle detections caused by snow, ice or frost.
  • L6 - Pre-flashing - enable this function if you want the gate beacon to flash for 3 seconds before each manoeuvre, before movement begins. Greater safety in exchange for a delay.
  • L7 - Disable the internal radio control - enabling this function disables the integrated radio receiver in the control unit. Enable this function if you use an external plug-in receiver such as the OXI. When the function is disabled, the internal receiver is active.
  • L8 - Slave control unit - enabled only when two opposing sliding gates are connected in an automated system.

8 functions that can be set to 8 possible values (level two programming)

  • L1 - Pause time: The time after which the gate closes automatically (automatic closing must be enabled for this to work):
    • L1 - After 5 seconds
    • L2 - After 15 seconds
    • L3 - After 30 seconds - factory setting
    • L4 - After 45 seconds
    • L5 - After 60 seconds
    • L6 - After 80 seconds
    • L7 - After 120 seconds
    • L8 - After 180 seconds
  • L2 - Step-by-step mode: How the drive/gate behaves when the remote control is pressed repeatedly (or when a command is repeatedly sent to the SbS wired input).
    • L1 - Open > Stop > Close > Stop
    • L2 - Open > Stop > Close > Open - factory setting
    • L3 - Open > Close > Open > Close
    • L4 - Condominium mode - the gate always completes the opening manoeuvre, i.e. it ignores further commands while opening.
    • L5 - Condominium mode with stop - as in L4, but the gate can be stopped while opening by holding the button for at least two seconds.
    • L6 - Step-by-step mode, type 2 - sequence as in L2, but a full-opening command is given by holding the button for at least 2 seconds; a shorter press only opens the gate partially.
    • L7 - Hold-to-run - the button on the remote control must be held down to move the drive.
    • L8 - During opening, the sequence works as in L2; during closing, the button must be held down as in L7, Hold-to-run.
  • L3 - Drive speed: How fast the gate opens and closes.
    • L1 - Very slow (30%)
    • L2 - Slow (45%)
    • L3 - Medium (58%)
    • L4 - Fast (72%) - factory setting
    • L5 - Very fast (86%)
    • L6 - Extremely fast (100%)
    • L7 - Opens as "L4 Fast", closes as "L2 Slow"
    • L8 - Opens as "L6 Extremely fast", closes as "L4 Fast"
  • L4 - OGI output behaviour: When and how the wired OGI (Open Gate Indicator) output operates. The output is 24 V DC (direct current), max. 10 W.
    • L1 - The output is open when the gate is closed and closed when the gate is open. During opening, it switches slowly and repeatedly; during closing, it switches quickly and repeatedly - factory setting.
    • L2 - Closed only when the gate is in the closed position; otherwise inactive.
    • L3 - Closed only when the gate is in the open position; otherwise inactive.
    • L4 - Activated only by radio output no. 2, i.e. if your remote is paired in Mode I, the output switches on when you press the second button on the remote.
    • L5 - Activated only by radio output no. 3, see the previous point.
    • L6 - Activated only by radio output no. 4, see the previous point.
    • L7 - Activated when the number of manoeuvres exceeds the maintenance-warning threshold; see "L7 Service required warning".
    • L8 - The output operates an electric lock; before opening starts, the control unit activates this output.
  • L5 - Motor force: How strongly the drive pushes, or how sensitive it is to obstacles.
    • L1 - Extra-light gate
    • L2 - Very light gate
    • L3 - Light gate
    • L4 - Average-weight gate
    • L5 - Medium-heavy gate - factory setting
    • L6 - Heavy gate
    • L7 - Very heavy gate
    • L8 - Exceptionally heavy gate
  • L6 - Partial opening distance: Pedestrian access - the distance the drive opens the gate when given a partial-opening command.
    • L1 - Distance: 0.5 metres
    • L2 - Distance: 1 metre - factory setting
    • L3 - Length 1.5 metres
    • L4 - Length 2 metres
    • L5 - Length 2.5 metres
    • L6 - Length 3 metres
    • L7 - Length 3.5 metres
    • L8 - Length 4 metres
  • L7 - Service reminder: the number of manoeuvres after which the drive signals that it may be time to service the gate/drive. This is for information only.
    • L1 - 1,000 manoeuvres
    • L2 - 2,000 manoeuvres
    • L3 - 4,000 manoeuvres
    • L4 - 7,000 manoeuvres
    • L5 - 10,000 manoeuvres
    • L6 - 15,000 manoeuvres
    • L7 - 17,000 manoeuvres
    • L8 - 20,000 manoeuvres
  • L8 - List of the last 8 manoeuvres and their errors: Strictly speaking, this is not programming, as it is used to identify the types of errors recorded by the drive during its last eight manoeuvres.
    • L1 - Result of the 1st manoeuvre
    • L2 - Result of the 2nd manoeuvre
    • L3 - Result of the 3rd manoeuvre
    • L4 - Result of the 4th manoeuvre
    • L5 - Result of the 5th manoeuvre
    • L6 - Result of the 6th manoeuvre
    • L7 - Result of the 7th manoeuvre
    • L8 - Result of the 8th manoeuvre

How to program the NICE Robus RBS drive

Of course, this depends on whether you want to program a level-one function (a function that can only be switched on or off) or a level-two function (a function that can be set to one of eight parameters).

The procedure starts the same way for both levels, which may give the impression that level two is used to set the values of level-one functions. That is not the case. For both methods, you should think of the functions (LEDs L1 to L8) as 8 level-one functions and another 8 level-two functions.

How to program a level-one function (a function that can only be switched on or off)

  1. Select the function you want to switch on or off. For example, let's switch on function L6 - Pre-flashing.
  2. Press and hold the STOP/SET button for about 5 seconds until LED L1 starts flashing, then release the button.
  3. Note: You have 10 seconds for each subsequent button press. If you do not press anything within 10 seconds, programming will end automatically.
  4. Use the OPEN (up arrow) and CLOSE (down arrow) buttons to move the flashing LED up or down until it reaches the LED corresponding to the function you want to switch on or off. So, for L6 - Pre-flashing, press the CLOSE button 5 times until the flashing LED moves to position L6.
  5. Now press the STOP/SET button once without holding it; the LED will change its flashing rate.
  6. Wait up to 20 seconds for the control unit to exit programming mode. Done.

    If you switched the function on, the corresponding LED will stay lit; if you switched it off, the corresponding LED will go out.

How to program a level-two function (a function that can be set to one of eight parameters)

  1. Select the function you want to reprogram and the value you want to set. For example, let's change L6 - Partial opening duration from its default setting, L2 - Length 1 m, to L5 - Length 2.5 m.
  2. Press and hold the STOP/SET button for about 5 seconds until LED L1 starts flashing, then release the button.
  3. Note: You have 10 seconds for each subsequent button press. If you do not press anything within 10 seconds, programming will end automatically.
  4. Use the OPEN (up arrow) and CLOSE (down arrow) buttons to move the flashing LED up or down until it reaches the LED corresponding to the function whose value you want to change. So, for L6 - Partial opening duration, press the CLOSE button 5 times until the flashing LED moves to position L6.
  5. Now press the STOP/SET button and keep holding it, even when an LED lights up (the currently set value). For the Partial opening duration function, the factory-set value L2 - Length 1 m will light up.
  6. Keep holding the STOP/SET button and repeatedly press the other button - the OPEN button (up arrow) or CLOSE button (down arrow) to move the lit LED to the value you want to set. In our example, you want to move the LED from L2 - Length 1 m to L5 - Length 2.5 m, so press the CLOSE button three times.
  7. Release the STOP/SET button, the LED whose value you changed will flash for a while (20 seconds), then stop flashing. In our example, LED L6 will flash for a while and then stop flashing.
  8. Done! You have successfully changed the value of a level-two function.

 If you don't understand, don't worry; we also have step-by-step instructions for the most commonly programmed functions :)

Step-by-step instructions (examples):

Step-by-step instructions for functions that can be switched on or off (level-one programming)

Enabling automatic closing

Assumption: LED L1 is off, meaning automatic closing is disabled.

  1. Press and hold the STOP/SET button; when LED L1 starts flashing, release the button.
  2. Within 10 seconds, press the STOP/SET button once; LED L1 will then change its flashing rate.
  3. Wait for LED L1 to stop flashing and remain lit.

Disabling automatic closing

Assumption: LED L1 is continuously lit, meaning automatic closing is enabled.

  1. Press and hold the STOP/SET button; when LED L1 starts flashing, release the button.
  2. Within 10 seconds, press the STOP/SET button once; LED L1 will then change its flashing rate.
  3. Wait for LED L1 to stop flashing and remain off.

Step-by-step instructions for functions that can be set to a value (level-two programming)

Control units with a Bus-T4 connector you can also program them from your mobile phone if you purchase a NICE BIDIWIFI, or another programmer. Programming is more convenient, and you also gain access to more detailed settings.