Sliding gate operator kit for gates up to 1500 kg - NICE Thor TH1500


Product availability: within 3 days

We usually dispatch goods within 3 days.


Sliding gate operator kit for gates up to 1500 kg - NICE Thor TH1500 Sliding gate operator kit for gates up to 1500 kg - NICE Thor TH1500
NICE-TH1500-KIT
within 3 days
€376.53 excluding VAT
€463.13 including VAT

 pcs
Weight
13 kg

Description of Sliding gate operator kit for gates up to 1500 kg - NICE Thor TH1500

NICE THOR TH1500 is an electromechanical drive for a sliding gate with a 230 V AC, built-in control unit and radio receiver. It is designed for a gate weighing up to 1,500 kg and with a leaf length of up to 12 m. It has a ventilated motor and a built-in control unit NICE ROA37. Mechanical limit switches determine the open and closed positions. The drive is non-reversible; in the event of a power outage, it can be released with a key so the gate can be moved manually.

Quick navigation
Choosing a drive Kit contents
Accessories Installation
Limit switches Manual release
Wiring Connections and polarity
Photocells First start-up
Settings Remote controls
Diagnostics Clearing the memory
Inspection and maintenance Specifications
Dimensions PDF manual

What type of gate is the THOR TH1500 suitable for?

Weight, length and number of operating cycles must be considered together with the resistance to gate movement, wind, ice and the condition of the track. The drive cannot compensate for a misaligned or sticking gate. The gate leaf must move smoothly along its entire travel, remain stationary in any position, and have anti-derailment protection and fixed mechanical stops in both directions.

Max. gate leaf weight 1,500 kg.
Max. gate leaf length 12 m.
Operation Up to 15 cycles/hour with a 6 m gate leaf, and no more than 5 cycles without a break. Do not automatically apply the 15 cycles/hour rating to a 12 m gate leaf.
Resistance to movement Check the required starting and continuous force against the motor torque and pinion; the manufacturer recommends at least a 50% safety margin.
Rack Module 4; clearance between the rack and pinion approximately 1–2 mm.

Choosing a larger motor does not in itself replace safety devices or force testing on the installed gate.

Kit contents

The kit contains: NICE-TH1500-D
NICE Thor TH1500 gate drive 1 × NICE Thor TH1500 drive NICE-TH1500

NICE Thor TH1500 drive with control unit ROA37 with built-in receiver and a maximum gate weight of 1,500 kg and passage width of up to 12 m

 
NICE Era FloR FLO2RE 2 × NICE Era FloR FLO2RE NICE-FLO2RE

Two-button remote control for operating a gate automatically from a distance. You can use it to control two devices or send two different commands to one device.

Detail 
NICE manual release key 2 × Manual release key  

In the event of a power outage, it disengages the drive's gearwheel so the gate can be moved manually by pushing or pulling.

 

What else you need for safe operation

What Why Type
Photocells Monitoring the passage area; wiring here.
  • NICE EPM with an NC relay contact; not BlueBUS EPMB.
Flashing light Movement warning; output 4–5 provides 230 V AC.
  • NICE ELAC. ELDC for low voltage is not suitable here.
Remote control Built-in receiver, storing remote controls.
STOP and safety edges Protection of hazardous areas as specified in the project.
  • Voltage-free NC input ALT 9–10; connect a resistive safety edge only via a suitable safety interface. This is not a direct 8.2 kΩ input.
Gear rack and stops Motion transmission and mechanical track restraint.
  • Module 4 rack. The limit switch does not replace a fixed mechanical stop.

Installing the drive and rack

Disconnect the power supply before opening the drive and secure it against being switched on. Prepare conduits and cable entries so that water cannot enter the motor; the foundation must not be allowed to flood. Keep the cover and manual release accessible.

NICE THOR TH1500 – base plate position relative to the rack, dimensions in mm

  1. Prepare the foundation and conduits according to the installation drawing. The base plate must be level, parallel to the gate's direction of travel, and securely anchored. Also determine its position based on how the rack is to be attached.
  2. Install the motor only after the foundation has cured. Adjust the height and secure it; the gate leaf's weight must not be supported by the drive pinion.
  3. Disengage the gearbox and fit the rack while moving the gate leaf by hand. The individual sections must form a straight line, with no step in height.
  4. Maintain approximately 1–2 mm clearance between the rack and pinion along the entire travel. Manually check the full travel in both directions and tighten the fasteners.

NICE THOR TH1500 – rack and clearance between the rack and pinion

Adjusting the limit switches

  1. With the gate released, move it by hand to the open position and stop approximately 2–3 cm before the fixed mechanical stop.
  2. Slide the corresponding limit-switch bracket along the rack until the switch is activated. Then move it a further at least 2 cm in the same direction and secure it.
  3. Set the closing position in the same way. The bracket must reliably engage the lever without striking the drive housing.
  4. Engage the gearbox, test both directions slowly, and check the run-on and activation of the correct FCA/FCC LED. The gate leaf must not hit the fixed stops while operating.

NICE THOR TH1500 – adjusting the mechanical limit-switch brackets

Manual release in the event of a power failure

The gate must be stationary. Disconnect the power and secure the gate leaf against unintended movement, especially on a slope or in windy conditions. Do not handle the gate while it is moving or put your hands into the gearing.

TH1500 – uncovering the lock and inserting the key

TH1500 – turning the key 90° and pulling out the handle

  1. Turn the lock cover and insert the key.
  2. Turn the key 90° clockwise and pull the handle towards you. The gate leaf can now be moved by hand.
  3. To re-engage the drive, close the handle, turn the key in the opposite direction, and move the gate slightly by hand until the gearbox engages mechanically. Remove the key and put it away.

Wiring

Connection Cable as specified in the manual Max. length
Power supply 3 × 1.5 mm² 30 m
Warning light 2 × 0.5 mm² 30 m
Antenna RG58 coaxial cable 20 m, less than 5 m recommended
Photocells TX / RX 2 × 0.5 mm² / 4 × 0.25 mm² 30 m / 30 m
Key switch 4 × 0.25 mm² 30 m

For power cables longer than 30 m, specify a larger cross-section, such as 3 × 2.5 mm², and protective earthing at the drive. Cable cross-sections and types must be checked for the specific route, protection, and environment; install power and control cables separately.

Controls, terminals, and polarity

Built-in ROA37 has 10 DIP switches, TL/TP/F trimmers, and a receiver button. Terminal 12 is the P.P. command (step-by-step); this input is not a Fototest power output.

TH1500 / ROA37 – original diagram of terminals 1–12 and antenna

TH1500 / ROA37 – layout of connectors and controls

Terminal Function and connection
1 / 2 / 3 – mains 1 = L, 2 = N, 3 = PE (GND protective earth). Power supply: 230 V AC, 50 Hz.
4–5 – warning light 230 V AC, max. 40 W. Use ELAC, not low-voltage ELDC.
8–9 – accessories 8 = 0 V AC, 9 = 24 V AC, tolerance ±25%, total max. 150 mA. This is AC voltage, so there is no fixed positive or negative terminal.
9 COMMON Common contact for the control and safety inputs; not protective earth (PE).
9–10 ALT Voltage-free NC stop contact with brief reversal.
9–11 FOTO Voltage-free NC photocell contact.
9–12 P.P. / SS Voltage-free NO command: open – stop – close – stop.
Separate ANT. 1–2 1 = antenna coaxial cable centre conductor, 2 = shield. Numbers 1–2 on the antenna connector are not mains terminals 1–2.

Board legend: a antenna; b DIP; c radio button; d TL; e TP; f control inputs and outputs; g limit switches; h warning light; i capacitor; l motor; m mains; n radio LED; o low-voltage fuse; p force F; q OK LED; r transformer; s mains fuse. Replace fuses only when the power is off, and use the same type and rating specified for the installed circuit board.

As shown in the diagram, bridge unused NC inputs ALT and FOTO to common terminal 9; leave any unused NO input unconnected. Wire multiple NC contacts in series and multiple NO contacts in parallel. A jumper must not replace a required safety device on a gate in operation.

Connecting NICE EPM photocells

Connection Terminals
Power supply for both TX and RX EPM 1 → ROA37 9 (24 V AC), EPM 2 → ROA37 8 (0 V AC). With AC, there is no fixed +/− polarity.
RX safety contact EPM 4 COM → ROA37 9; EPM 5 NC → ROA37 11 FOTO. Do not use RX terminal 3 NO for this purpose.

In this wiring configuration, the ROA37 has no separate Phototest output. When using multiple pairs, wire the NC safety contacts in series and calculate the current draw; one EPM pair can draw up to 55 mA. If there is a risk of mutual interference, the EPM manual allows synchronization with AC power by adjusting the SYNC jumper on both TX units and reversing the power supply to one pair. Make this adjustment according to the specific layout.

The TX and RX units must be exactly opposite each other. For distances greater than 10 m, adjust the +10m jumper on the RX as described in the EPM manual. The typical effective range of the EPM is 15 m; fog, rain and dust can reduce it. Photocells protect the passageway, not every potential trapping or shearing point on the gate.

Initial start-up and checking the direction

Before connecting the power, complete the mechanical stops, limit-switch brackets, protective earthing and safety input wiring. If the gate leaf has a wicket gate, opening it must disable automatic operation.

  1. Disengage the motor, move the gate leaf manually to approximately the midpoint of its travel, then re-engage the drive.
  2. After switching on, the OK LED should flash approximately once per second. With the path clear and the gate away from its end positions, PHOTO/FOTO, FCA and FCC should be lit; the command NO input should be off when no command is given. The gate should not move by itself.
  3. Operate the limit switch lever and check that the correct FCA or FCC LED goes out. If there is a fault, disconnect the power and check the connectors, safety devices and fuses.
  4. After completing the setup, use a brief SbS/P.P. command to check that the first movement after switching on is opening. Stop it if it moves in the opposite direction. The opposite direction may also reverse the operation of the safety devices.

If the initial direction is reversed

Disconnect the mains and verify that the system is de-energized. As shown in the original diagram, rotate the motor connector and limit-switch connector by 180°. Switch on and repeat the opening test from the midpoint of travel. Do not reverse the direction by swapping the safety inputs or increasing the force.

The TH1500/ROA37 sets operating time and functions using trimmers and DIP switches.

Testing the completed gate

  1. Test full opening and closing, confirm that the gate stops correctly before the mechanical stops, and check that it moves smoothly.
  2. Test each safety device individually. Interrupt the photocell beam at the TX, at the RX and between them; check that the gate stops or reverses as expected.
  3. Measure the forces on the completed gate and set the lowest force that ensures reliable operation. Photocells and the F setting do not replace an assessment of all potential hazards.
  4. Only after successful testing, hand over the manual, keys, instructions for manual operation and a maintenance schedule.

DIP switch and trimmer settings

Make adjustments while the gate is stationary. Disconnect the power before working on the wiring. After changing the mode, time or force, retest full opening and closing and all safety devices.

DIP 1 DIP 2 Mode
OFF OFF Manual – movement only while the command is held.
ON OFF Semiautomatic – the full movement is triggered by a brief command.
OFF ON Automatic – closing follows opening and a pause.
ON ON Automatic + Always close – after power is restored, closing may follow after a 5 s pre-flashing warning.

DIP

Function Effect
3 ON Condominium mode While opening, further Step-by-Step commands are ignored; while closing, they reverse the direction. Not available in manual mode.
4 ON Pre-flashing 5 s before movement; 2 s in manual mode.
5 ON Closing after photocell activation Automatic mode: closes 5 s after the passageway is clear. Semiautomatic mode: activating FOTO while closing triggers automatic closing after the set pause.
6 ON FOTO active during opening too An interrupted beam also stops opening; in semiautomatic/automatic mode, movement resumes once the beam is clear.
7 ON Soft start Reduces jolting when starting.
8 ON Slowdown The TL setting must account for slowdown starting approximately 50–70 cm before the limit switch. Motor torque is also reduced; the gate may stop if resistance is too high.
9 ON Brake Braking at the end of movement: gentle at first, then more intensive.
10 Unused No function in this version.

Trimmer What it adjusts How to check
TL Maximum opening/closing time. Range according to the manual: approximately 2.5 to over 40 s; with TLM extension, approximately 40 to over 80 s. In semi-automatic mode, perform a complete opening and closing cycle. Allow a margin of 2–3 s. If the range is insufficient, use the TLM extension according to the control board. If slowdown is enabled, also set the time according to when it begins.
TP Pause time before automatic closing. Approximately 5 to over 80 s. Enable automatic mode, fully open the gate, and measure the actual pause before closing begins.
F Force / motor torque. Confirm the setting by measuring impact forces and carrying out a safety test. Increasing F is not a way to compensate for a mechanical fault in the gate.

Built-in receiver and remote controls

The ROA37 has a built-in multi-code receiver 433.92 MHz. It supports the O-Code/FloR/TTS family, or Flo, or Smilo. The first remote control stored determines the family for subsequent remote controls. The FLO2RE included in the kit belongs to the FloR family. Program the receiver while the gate is stationary.

Mode I – storing all buttons on a remote control

  1. Press and hold the RADIO/receiver button until its LED lights up (approximately 4 s), then release it.
  2. Within 10 s, press and hold the chosen button on the new remote control for approximately 3 s, until the receiver confirms storage with three flashes.
  3. Another remote control can be stored in the same way within the next 10 s; otherwise, wait for the mode to end.

Button in Mode I Assigned command
1 Step-by-step
2 ALT – stop
3 Open
4 Close

One- and two-button remote controls use only the corresponding first buttons. On the TH1500, the second button does not automatically function as a pedestrian opening button.

Mode II – assigning one command to a selected button

Number of RADIO button presses Command
1 Step-by-step
2 ALT – stop
3 Open
4 Close

Briefly press RADIO as many times as the number assigned to the required command. The LED will flash the same number of times. Within 10 s, press and hold the selected button on the remote control for approximately 3 s, until three flashes confirm storage. Repeat the procedure for each additional button.

Adding a remote control using a working remote control

Near the receiver, approximately 10–20 m away, press and hold the new remote control button for at least 5 s and release it. On the old remote control press the corresponding button 3 times; then press the button on the new remote control once. The new remote control will inherit the old one’s assignment. In Mode I, you can use any button on the old remote control; in Mode II, use the button assigned to the required command. Leave powered only the receiver you want to program.

When powered on, the receiver LED indicates the family: 1 flash for Flo, 2 flashes for O-Code/FloR/TTS, 3 flashes for Smilo; 5 flashes indicates empty memory. To select a different family, first erase the receiver’s entire memory as described in the following section.

Troubleshooting and common faults

Symptom Meaning / what to check
OK: approximately 1 flash/s The control unit is running and waiting for a command.
OK: rapid double flash An input or DIP switch has changed state.
OK: very rapid flashing for approximately 3 s Initial test after switching on the power supply.
OK: irregular flashing The test or internal check has failed; check the power supply and wiring. If the problem persists, contact service.
PHOTO / ALT is off The NC safety circuit is open. Check the photocells, contacts, and wiring.
FCA / FCC When the corresponding limit switch is activated, its LED goes out. If the function is reversed, check the direction and connector.
Gate stops during slowdown Possible high resistance or loss of torque during slowdown. First check the mechanics, then the TL/DIP 8 setting.

If the motor does not respond, first check the power supply, fuse protection, safety input status, and command. If the direction of travel is reversed, correct it according to the procedure given. If there is unusual noise, damage, or jerky movement, stop using the system; do not increase the force as a substitute for repair.

Erasing the memory

The receiver button erases its radio memory, not the mechanical settings of the DIP switches and trim pots. With the gate stationary, press and hold the button: after approximately 4 s the LED lights up, after another 4 s it goes out, and after approximately 4 more seconds it starts flashing.

Button release Result
Precisely during the 3rd flash Erases all stored remote controls.
Precisely during the 5th flash Erases the receiver’s entire memory, including settings and code family.

After a complete erase, the first new remote control will determine the code family again. Check the mode and operating time settings separately.

Regular inspection and maintenance

Arrange for professional maintenance at least every 6 months. For intensive use or harsh environments, follow the service plan’s adjusted interval.

  • After disconnecting the power, check the fastenings, corrosion, cables, and signs of water ingress.
  • Check the pinion, rack, guides, and stops for wear and play, and check that the gate moves freely by hand.
  • Clean the photocells and check the manual release. After switching the power back on, test all safety devices, stopping functions, and forces.
  • Keep a service record and the manual. Do not enter the passage while the gate is moving; keep remote controls and fixed controls out of reach of children.

NICE TH1500 technical specifications

Power supply / motor 230 V AC, 50 Hz / single-phase asynchronous
Power consumption according to the manual 350 W, 500 W peak
Current / capacitor 1.6 A / 14 µF
Rated torque 12 Nm (360 N according to the manual)
Maximum torque of the older version 35 Nm according to the enclosed Czech manual; check the specific version when replacing it
Rated speed 0.16 m/s
Max. gate leaf weight / length 1,500 kg / 12 m
Operating cycles 15 cycles/hour with a 6 m gate leaf; max. 5 consecutive cycles
Protection rating / electrical class IP44 / I – protective earthing
Thermal protection 140 °C
Temperature −20 to +50 °C
Rack Module 4
Auxiliary output 24 V AC ±25%, max. total 150 mA
Flashing light 230 V AC, max. 40 W
Drive weight 11.5 kg
Radio 433.92 MHz, integrated in ROA37

Dimensions and installation space

NICE TH1500 – original dimensioned drawing in millimetres

The TH1500 installation drawing shows a footprint of 335 × 203 mm and an overall height of 275 mm. When choosing a location, leave enough space to open the cover, access the key and safely operate the manual release.

We can help you choose the right setup via contact. Please provide the gate length and weight, the expected number of cycles and, for a replacement, a photo of the rating plate and control board.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about Sliding gate operator kit for gates up to 1500 kg - NICE Thor TH1500

Product: Sliding gate operator kit for gates up to 1500 kg - NICE Thor TH1500
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.