Description of Sliding gate drive kit up to 600kg/6m NICE ROBO600 (B)
NICE ROBO600 is an electromechanical operator for a sliding gate with a 230 V AC, built-in control unit and radio receiver. This kit is designed for a gate weighing up to 600 kg and a passage width of up to 6 m. Mechanical limit switches set the open and closed positions. The operator is non-reversible; in the event of a power failure, it can be released with a key so the gate can be moved manually.
Which gates is the ROBO600 suitable for?
Weight, length and number of cycles must be considered together with the resistance to gate movement, wind, ice and the condition of the guide. The operator does not fix a misaligned or sticking gate. The gate leaf must move smoothly along its entire travel, remain stationary in any position, and be fitted with anti-derailment protection and fixed mechanical stops in both directions.
| This kit's specifications | Up to 600 kg / 6 m passage width. |
|---|---|
| Motor-only limit according to the manual | Up to 600 kg and a gate leaf length of up to 8 m. For gates over 6 m, have the complete system checked for suitability. |
| Manual movement resistance | No more than 25% of the peak force of 600 N, i.e. 150 N throughout the entire travel. This is a selection criterion, not a permitted impact force on a person. |
| Rack | Module 4; Z15 pinion. |
Cycle limits
| Gate leaf length | Max. cycles/hour | Max. consecutive cycles |
|---|---|---|
| Up to 4 m | 40 | 20 |
| Over 4 m up to 6 m | 25 | 13 |
| Over 6 m up to 8 m | 20 | 10 |
One cycle consists of opening and closing. The motor's maximum continuous operating time is 4 minutes. These limits do not override the requirements for movement resistance and correct operating-time settings.
Choosing a more powerful motor does not, by itself, replace safety devices or force testing on the completed gate.
Kit contents
The NICE RO600-B kit includes an operator with an integrated control unit and receiver, plus a remote control. For a complete installation, you will need a suitable rack, anchoring, end stops and safety devices appropriate for the specific gate. Select the exact equipment for the expanded system when placing your order.
What else do you need for safe operation?
| Item | Why | Type |
|---|---|---|
| Photocells | Monitors the passage area; wiring here. |
|
| Flashing light | Signals gate movement; output 4–5 supplies 230 V AC. |
|
| Remote control | Built-in receiver, remote control programming. |
|
| STOP and safety edges | Protects hazardous areas as specified in the design. |
|
| Rack and end stops | Transmits movement and mechanically secures the travel path. |
|
| Service programming | Diagnostics and settings. |
Installing the operator and rack
Before opening the operator, disconnect the power supply and secure it against being switched on. Prepare the conduits and cable entries to prevent water from entering the motor; the foundation must not be allowed to flood. Keep access to the cover and the manual release clear.
- Prepare the foundation and conduits according to the installation drawing. The foundation plate must be level, parallel to the gate's direction of travel, and securely anchored. Determine its position also according to how the rack will be mounted.
- Install the operator only after the foundation has cured. Adjust its height and secure it; the operator pinion must not bear the weight of the gate leaf.
- Disengage the drive and fit the rack while moving the gate leaf by hand. The sections must form a straight line with no height steps between them.
- Maintain an approximately 1–2 mm clearance between the rack and pinion along the entire travel path. Check the full travel path manually in both directions and tighten the mountings.
Adjusting the limit switches
- With the gate released, move it manually toward the open position and stop approximately 2–3 cm before the fixed mechanical stop.
- Slide the corresponding limit-switch bracket along the rack until the switch activates. Then move it further in the same direction by at least 2 cm and secure it.
- Set the closing position in the same way. The bracket must reliably engage the lever without striking the operator housing.
- Engage the drive, slowly test both directions, and check the stopping point and that the correct FCA/FCC LED lights up. The gate leaf must not hit the fixed stops while moving.
Manual release during a power outage
The gate must be stationary. Disconnect the power and secure the gate leaf against unintended movement, especially on a slope or in windy conditions. Do not handle the gate while it is moving or put your hands in the gearing.
- Uncover the lock and insert the supplied key.
- Turn the key in the direction indicated by the arrow in the illustration and open the release lever. The gate can now be moved slowly by hand.
- To re-engage the operator, close the lever, secure the lock, and remove the key. Move the gate leaf slightly so the drive engages mechanically. Only then restore the power and test operation.
Wiring
| Connection | Cable as specified in the manual | Max. length |
|---|---|---|
| Power supply | 3 × 1.5 mm² | 30 m |
| Flashing light | 2 × 1.5 mm² | 10 m |
| Antenna | RG58 coaxial cable | 10 m; less than 5 m recommended |
| Photocells TX / RX | 2 × 0.25 mm² / 4 × 0.25 mm² | 30 m / 30 m |
| Key switch | 2 × 0.5 mm² per contact; 4 × 0.5 mm² for two contacts | 20 m |
For power cables longer than 30 m, specify a larger cross-section, for example 3 × 2.5 mm², and protective earthing at the operator. Cable cross-sections and types must be checked for the specific route, circuit protection, and environment; install power and control cables separately.
Control unit, terminals, and polarity
The following wiring applies to the ROBO600 board with 10 DIP switches, TL/TP/F trimmers, and RADIO, PROGRAM, and SbS buttons. A newer version also has the Standby function .
| Terminal / connector | Function and connection |
|---|---|
| Mains L / N / PE | 230 V AC, 50/60 Hz. L is live, N is neutral, and PE is protective earth; these are not DC polarity terminals. |
| 4–5 FLASH | Switched 230 V AC output for a mains-powered flashing light; no +/− polarity. |
| 8 (0 V) / 9 (+24 V) | Auxiliary power supply 8 = negative (−), 9 = positive (+), 24 V DC ±10 %, total max. 100 mA. |
| 9–10 STOP | Learned safety input for an NO/NC contact or resistive device, as shown in the diagram. After changing it, perform a new detection. |
| 9–11 PHOTO | Voltage-free NC photocell contact. An interruption during closing reverses the direction of travel. |
| 8–12 PHOTOTEST | Tested power supply for the TX transmitter; 8 = 0 V (−), 12 = tested +24 V, max. 100 mA. This is not a permanent power supply for external controls. |
| 9–13 SbS | Voltage-free NO Step-by-Step command. The external relay only closes 9–13; it must not supply its own voltage to these terminals. |
| AERIAL 1–2 | 1 = coaxial cable core, 2 = shielding; this is not a power supply for accessories. |
| LIMIT SWITCH / MOTOR | Limit-switch and motor connectors; change the orientation only with the power off, following the procedure for the opposite direction. |
For the auxiliary output, add together the current draw of all connected devices. One pair of EPM photocells can draw up to 55 mA; two pairs may exceed the 100 mA limit even before additional accessories are connected. In that case, a separately designed power supply is required. Voltage-free NO/NC contacts have no +/− polarity.
Safety input STOP 9–10
You can connect a voltage-free NO contact, an NC contact, or a safety edge with a constant resistance of 8.2 kΩ. The input type is detected during setup; a change from the learned state stops movement and briefly reverses direction.
Wire multiple NO contacts in parallel and multiple NC contacts in series. Resistive safety edges can be wired in a cascade with a single 8.2 kΩ end-of-line resistor, as specified in the edge instructions. Combined types must be wired according to the installation manual; do not create arbitrary jumper combinations. An 8.2 kΩ resistor is not a substitute for a required safety device. After each change, repeat device learning and test their operation.
Connecting NICE EPM photocells
| EPM | Without Phototest | With Phototest |
|---|---|---|
| TX terminal 1 (+) | 9 (+24 V DC) | 12 (tested +24 V DC) |
| TX terminal 2 (−) | 8 (0 V) | 8 (0 V) |
| RX terminals 1 (+) / 2 (−) | 9 / 8 | 9 / 8 |
| RX terminals 4 COM / 5 NC | 9 / 11 | 9 / 11 |
RX terminal 3 (NO) is not used for the PHOTO safety function. After completing the wiring, perform device learning and test by interrupting the beam. When powering the EPM with DC, do not cut the SYNC jumper, which is intended for synchronisation with AC power. Connecting two pairs also requires checking the power consumption and mutual interference.
The TX and RX must be exactly opposite each other. For distances over 10 m, adjust the +10m jumper on the RX as specified in the EPM instructions. The EPM’s typical effective range is 15 m; fog, rain and dust can reduce it. Photocells protect the gate opening, not every potential trapping or shearing point on the gate.
Initial start-up and checking the direction
Before connecting the power, the mechanical stops, limit-switch brackets, protective earth and safety input wiring must be in place. If the gate leaf has a wicket gate, opening it must inhibit automatic movement.
- Disengage the motor, move the gate leaf by hand to approximately the midpoint of its travel, then re-engage the drive.
- After switching on, the OK LED should flash approximately once per second. With the path clear and the gate away from its limit positions, PHOTO/FOTO, FCA and FCC should be lit; the command NO input should be off when no command is active. The gate should not move by itself.
- Operate the limit-switch lever to check that the correct FCA or FCC LED goes out. If there is a fault, disconnect the power and check the connectors, safety devices and fuses.
- After completing the settings—and, on the ROBO600, after learning the safety devices—use a brief SbS/P.P. command to check that the first movement after power-up is opening. Stop it if it moves in the opposite direction. The safety devices may also operate in reverse if the direction is reversed.
If the initial direction is reversed
Disconnect the mains and verify that the system is de-energised. As shown in the original diagram, rotate the motor connector and the limit-switch connector by 180°. Switch on and repeat the opening test from the midpoint of the travel. Do not reverse the direction by swapping the safety inputs or increasing the force.
Learning STOP and PHOTO
The ROBO600 must learn the connected safety devices. Repeat this after changing them and also after changing the position of DIP 1 or DIP 2.
- Press and hold PROGRAM. After approximately 3 s, learning starts and the OK LED flashes faster; keep holding the button.
- Wait for learning to finish: the STOP LED lights up and the OK LED remains green.
- Release the PROGRAM button within 10 s. Three green flashes confirm success; five red flashes indicate failure.
- Check the STOP and PHOTO LEDs and test both devices. If learning fails, resolve the cause and repeat the procedure.
Testing the completed gate
- Test a full opening and closing cycle, correct stopping before the mechanical stops, and smooth operation.
- Test each safety device separately. Interrupt the photocell beam at the TX, at the RX and between them; check that the gate stops or reverses as expected.
- Measure the forces on the completed gate and set the lowest force that ensures reliable movement. Photocells and the F setting do not replace an assessment of all hazardous areas.
- Only after successful testing, hand over the manual, keys, instructions for manual operation and a maintenance plan.
DIP switch and trimmer settings
Change the settings while the gate is stationary. Disconnect the power before working on the wiring. After changing the operating mode, time or force, retest the full opening and closing cycle and all safety devices.
| DIP 1 | DIP 2 | Mode |
|---|---|---|
| OFF | OFF | Dead-man – movement only while the command is held. |
| ON | OFF | Semi-automatic – a brief command initiates a full movement cycle. |
| OFF | ON | Automatic – the gate closes after opening and a pause. |
| ON | ON | Automatic + Always Close – after power is restored, the gate may close following a 5 s pre-flash warning. |
| DIP | Function | Effect |
|---|---|---|
| 3 ON | Condominium mode | While opening, subsequent Step-by-Step commands are ignored; while closing, a command reverses the direction. Not in manual mode. |
| 4 ON | Pre-flashing | 5 s before movement; 2 s in manual mode. |
| 5 ON | Closing after photocell clearance | Automatic mode: closes 5 s after the gate opening is cleared. Semi-automatic mode: activation of PHOTO while closing enables automatic closing after the set pause. |
| 6 ON | PHOTO also during opening | Interrupting the beam also stops opening; in semi-automatic/automatic mode, movement resumes once the beam is clear. |
| 7 ON | Soft start | Reduces jolting at start-up. |
| 8 ON | Slowdown | The TL setting must account for slowdown beginning approximately 50–70 cm before the limit switch. Motor torque is also reduced; the gate may stop if there is too much resistance. |
| 9 / 10 | Electric braking | OFF/OFF = off; OFF/ON = low; ON/OFF = medium; ON/ON = high. |
Factory settings according to the manual: DIP 1 and 8 ON, all others OFF (semi-automatic mode with slowdown). After changing DIP 1–2, always learn the devices again. During deceleration, the speed is approximately 30% of the nominal speed; torque is reduced by 70%. Deceleration starts at TL/2. The default TL of 90 s means deceleration starts after 45 s; check the effect of the change during the next opening from the end position.
| Trimmer | What it controls | How to check |
|---|---|---|
| TL | Maximum opening/closing time. | In semi-automatic mode, run a complete opening and closing cycle. Allow a margin of 2–3 s. If the range is insufficient, use a TLM extension, as specified for the control board. When setting deceleration, also account for its start time. |
| TP | Pause time before automatic closing. | Enable automatic mode, open the gate fully, and measure the actual pause before closing begins. |
| F | Force / motor torque. | Confirm the setting by measuring impact forces and carrying out a safety test. Increasing F is not a way to overcome a mechanical fault in the gate. |
Newer version – Standby mode
This section applies only to the ROBO600 version that supports Standby. It does not apply to older control boards without this feature. After devices have been detected, the default standby time is 300 s; for a new or fully erased control board, the time before detection is 600 s. In Standby mode, the auxiliary power output is inactive, which is important when using external controls.
- Briefly press PROGRAM and read the OK LED: 2 flashes = Standby active; 1 flash = inactive.
- Briefly press PROGRAM again to select the required state.
- To save, hold PROGRAM for at least 5 s until the OK LED resumes its normal 1 Hz flashing. Change the standby time using Oview or ProView, not with this button procedure.
Built-in receiver and remote controls
ROBO600 has a built-in receiver 433.92 MHz with O-CODE encoding. Choose a transmitter to match the specific control board; the same frequency alone does not guarantee compatibility. Program with the gate stationary.
Mode I – store the entire remote control
- Hold down the RADIO/receiver button until its LED lights up (about 4 s), then release it.
- Within 10 s, hold down the chosen button on the new remote control for about 3 s, until the receiver confirms storage with three flashes.
- Another remote control can be stored in the same way within the next 10 s; otherwise, wait for the mode to end.
| Button in Mode I | Assigned command |
|---|---|
| 1 | Step-by-step |
| 2 | Partial pedestrian opening |
| 3 | Open |
| 4 | Close |
A one- or two-button remote control will use only the corresponding first buttons. According to the manual, ROBO600 can store up to 100 remote controls in Mode I.
Mode II – assign one command to a selected button
| Number of RADIO button presses | Command |
|---|---|
| 1 | Step-by-step |
| 2 | Partial opening |
| 3 | Open |
| 4 | Close |
| 5 | Stop |
Briefly press RADIO as many times as the number of the required command. The LED will flash the same number of times. Within 10 s, hold down the selected remote-control button for about 3 s until three flashes confirm storage. Repeat the procedure for each additional button.
Adding a remote control using a working remote control
Near the receiver, at a distance of approximately 10–20 m, hold down the button on the new remote control for at least 5 s and release it. On the old remote control, press the corresponding button 3 times; then press the new remote-control button once. The new remote control will take over the assignment of the old one. In Mode I, you can use any button on the old remote control; in Mode II, use the button assigned to the required command. Leave only the receiver you want to program powered.
Radio memory lock
If storing or deleting does not work, the memory may be locked. Turn off the power, hold down RADIO, and turn the power back on. After about 5 s and two slow flashes of the radio LED, release the button. Within 5 s, use brief RADIO presses to select: LED off = unlocked; LED on = locked. Five seconds after the last press, two slow flashes confirm the end.
Diagnostics and common faults
| Indication | Meaning / what to check |
|---|---|
| OK: 1 green flash/s | Normal operation. |
| OK: 2 rapid green flashes | Change in the state of an input, photocells, or a radio command. |
| OK: 1 red flash, pause, then 1 again | Devices were not detected correctly, or DIP 1–2 has been changed. Check the wiring and repeat device detection. |
| OK: 2 red flashes | Photocell triggered. Check for an obstruction, TX/RX alignment, and the NC contact. |
| OK: 4 red flashes | STOP active. Check the safety device and its wiring. |
| OK: 5 red flashes | Internal parameter error. Wait at least 30 s; if the error persists, erase and redetect the devices. |
| OK: 7 red flashes | Internal circuit error or DIP 1–2 has been changed. After disconnecting and restoring the power, check the wiring; if the mode has changed, repeat device detection. A persistent error requires service. |
| OK: 8 red flashes | A command remains active. Release the button or de-energize the relay that is continuously closed. |
| OK off / continuously on | Check the power supply and fuses; a persistent fault indication may mean the control board is faulty. |
| PHOTO / STOP off | A safety input is preventing movement. Do not bypass it; check the device and device detection. |
| Radio LED: 1 / 6 / 8 rapid flashes | Remote control already stored / incompatible encoding / memory full. |
If the motor does not respond, first check the power supply, protection, safety input status, and command. If the movement is in the wrong direction, correct the direction using the of the above procedure. If you notice unusual noise, damage, or jerky movement, stop using the gate; do not increase the force as a substitute for repair.
Erasing the memory
Erasing all remote controls
With the memory unlocked, hold down RADIO, until the LED lights up, goes out, and starts flashing. Release the button during the 3rd flash. Five flashes confirm that the remote controls have been erased. All stored transmitters will be erased, so be ready to program them again.
Erasing the control unit and learned devices
- With the motor stopped, switch off the power.
- Hold down PROGRAM and switch the power back on. Keep holding the button until the OK LED lights up, goes out, and starts flashing.
- Release PROGRAM during the 3rd flash of the OK LED. Five flashes confirm success.
- Repeat the safety-device learning procedure and carry out a full set of tests. This procedure does not erase the remote controls, but it releases the radio memory lock. The mechanical DIP switch and trimmer settings do not change automatically.
Regular inspection and maintenance
Arrange for professional maintenance at least every 6 months or after 20,000 operating cycles, whichever comes first. For intensive use or harsh environments, follow the maintenance schedule for the adjusted interval.
- With the power disconnected, check the fastenings, corrosion, cables, and water ingress.
- Check the pinion, rack, guide, and stops for wear and play, and check that the gate moves freely by hand.
- Clean the photocells and check the manual release. After reconnecting the power, test all safety devices, the stopping function, and the forces.
- Keep the maintenance record and the manual. Keep out of the gate's path while it is moving; keep remote controls and fixed controls out of children's reach.
NICE ROBO600 technical specifications
| Motor and control unit power supply | 230 V AC, 50/60 Hz |
|---|---|
| Rated power consumption | 300 W |
| Rated / peak torque | 9 / 18 Nm |
| Corresponding rated / peak force | 300 / 600 N; drive force is not the gate's weight |
| Speed at no load / at rated torque | 11 / 8.5 m/min |
| Rack / pinion | Module 4 / Z15, pitch diameter 60 mm |
| Max. gate weight | 600 kg |
| Max. gate leaf length / opening offered by this kit | 8 m according to the manual / 6 m passage width for this product listing |
| Continuous operation | Max. 4 minutes; cycles according to gate leaf length |
| Ingress protection / electrical class | IP44 / I – protective earthing |
| Temperature | −20 to +55 °C |
| Auxiliary output | 24 V DC ±10%, max. 100 mA |
| FLASH output | 230 V AC, max. 60 W according to the technical table |
| Weight of the drive unit alone | 11 kg |
| Radio | 433.92 MHz, built-in O-CODE receiver |
Dimensions and installation clearance
The ROBO600 installation drawing gives the overall dimensions 340 × 220 × 303 mm (height) and the pinion axis is 85 mm above the base. Use this drawing as the basis for installation. When choosing the location, leave enough space to open the cover, access the key, and safely operate the manual release.
We can help you choose a system via contact. Please provide the gate length and weight, the expected number of cycles, and, for a replacement, a photo of the rating plate and control board.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]