NICE Tub TUB3500 (A) – standalone drive for sliding gates


Product availability: for the question

The product may not be available, contact us for more information.


NICE Tub TUB3500 (A) – standalone drive for sliding gates NICE Tub TUB3500 (A) – standalone drive for sliding gates
NICE-TUB3500-A
for the question
€1,499.40 excluding VAT
€1,844.26 including VAT

 pcs
Weight
60 kg

Description of NICE Tub TUB3500 (A) – standalone drive for sliding gates

NICE TUB3500 is a standalone industrial operator for a sliding gate weighing up to 3,500 kg and measuring up to 30 m. It has a 400 V AC three-phase motor, built-in control unit Mindy A500, mechanical brake, fan cooling and a pinion for module 6 rack. It is non-reversible; if the power goes out, the gearbox can be released and the gate moved manually.

Quick navigation
Choosing an operatorControl unit
Operator equipmentDimensions
Installation and rackLimit switches
Manual releaseWiring
Connections and polarityPhotocells
Initial startupSettings
Remote controlsAccessories
TroubleshootingInspection and maintenance
SpecificationsPDF manual

When to choose NICE TUB3500

Designed for large, heavy sliding gates at industrial sites. When choosing an operator, consider the gate weight, actual leaf length, resistance to movement, wind exposure, and the number of opening and closing cycles. The gate must move smoothly by hand, must not start moving on its own, and must have solid mechanical stops in both directions.

Gate weightUp to 3,500 kg.
Gate lengthUp to 30 m; the maximum number of cycles per hour decreases as the length increases.
Power supply3~ 400 V AC ±10%, 50 Hz; protective earthing required.
RackModule 6. Module 4 racks used with smaller operators are not interchangeable.

Cycles per hour by gate leaf length

Gate leaf lengthMax. cycles/hour
Up to 5 m30
Over 5 up to 10 m15
Over 10 up to 15 m10
Over 15 up to 20 m7
Over 20 up to 25 m6
Over 25 up to 30 m5

One cycle consists of one complete opening and closing. When planning the installation, comply with the dimensional, weight and operating limits together; the maximum weight alone does not confirm that the operator is suitable for a particular gate. The manufacturer also specifies for TUB3500 max. 200 cycles per day and 30 minutes of continuous operation. These specifications do not override the cycles-per-hour limits or the travel time set in the A500.

When replacing an existing operator, also check the accessories, wiring method and installation space.

Built-in Mindy A500 control unit

The Mindy A500 is included in the TUB3500 operator. It has 10 function DIP switches, TL, TP and F trimmers, an input for mechanical limit switches, a photocell test function and an older connector for FLOXI-family receivers. The following wiring instructions apply to this control board; if the control unit has been replaced, follow the instructions for the unit installed.

The option to configure the control unit itself for a different power supply does not turn this motor into a single-phase 230 V operator. Connect the TUB3500 according to its rating plate and the wiring diagram for the three-phase 400 V version.

What the operator includes and what you need to add

  • Motor with gearbox, built-in control unit, mechanical brake and fan.
  • Pinion module 6, 18 teeth.
  • Manual release mechanism for moving the gate by hand.
  • For a complete automation system, you need a suitable rack, anchoring, mechanical stops and safety devices appropriate for the specific gate. Remote control requires a compatible receiver and transmitters.

When you place your order, we’ll match the mounting hardware, rack and accessories to your specific setup. The operator on its own is not a complete automatic gate system.

Dimensions and installation space

TUB3500 – original dimension drawing in millimetres

The drawing specifies a height of 580 mm, a width of 480 mm, a housing depth of 230 mm and an overall dimension to the pinion of 305 mm. The pinion axis is shown in the drawing at a height of 160 mm. Dimensions are in millimetres. Keep the access door, manual release, limit switch and electrical control unit accessible.

Installing the base, motor and rack

Before starting work, disconnect all power supplies and secure them against being switched on. The foundation must be solid, level and protected from flooding. When preparing the conduits, prevent water and condensation from entering the control unit.

  1. For an existing suitable foundation, use anchors appropriate for the substrate. For a new foundation, prepare an excavation and conduits; determine the foundation dimensions according to the installation location.
  2. Install the base plate with four anchors parallel to the gate leaf and level. The anchor detail specifies a thread projection of 55–60 mm. Allow the concrete to cure completely.
  3. Place the motor on the plate, align it with the gate leaf and secure it with four nuts and washers. Release the gearbox before proceeding.
  4. Fasten the module 6 rack progressively along the entire travel path. Maintain a 2–3 mm clearancebetween the rack and pinion; the gate’s weight must not be borne by the operator.
  5. Move the gate by hand several times. Check for proper mesh, smooth passage over rack joints and consistent clearance along the entire length.

TUB3500 – 55–60 mm anchor, limit-switch bracket and base plate installation

TUB3500 – securing the motor and fitting the cover

Limit switches and mechanical stops

Two brackets are fitted to the rack to operate the limit-switch lever for opening and closing. They do not replace the gate’s fixed mechanical stops. The lever must move freely, and the brackets must act in the correct direction.

After the limit switch is triggered, allow for a run-on distance of approximately 2–3 cm. Adjust the brackets so the gate stops safely before reaching the mechanical stops; also check the run-on distance with the motor warm. When checking the TUB3500, the stopped gate leaf should remain approximately 4–5 cm from the fixed stop.

If the run-on distance is longer, check and adjust the mechanical brake. The power must be switched off before making adjustments. According to the instructions, first tighten the nut on the shaft by half a turn clockwise; overtightening may lock the motor. Repeat the tests after making the adjustment.

TUB3500 – adjusting the mechanical brake with the power disconnected

Manual release during a power failure

Release the drive only when the gate is stationary and the power is switched off. Secure the gate leaf to prevent it from moving on its own. Demonstrate the procedure during handover and provide the keys.

  1. Use the key to open the drive cover.
  2. Insert the Allen key into the shaft and fully loosen the inner screw as shown in the illustration.
  3. Remove the key and close the cover. You can now carefully move the gate by hand.
  4. To re-engage the drive, follow the procedure in reverse. Check that the drive is engaged and the cover is closed; its safety microswitch must be activated.

TUB3500 – opening the cover, disengaging the drive and moving the gate manually

Wiring for a typical setup

ConnectionCableLength
Power supply to the drive4 × 1.5 mm²Up to 30 m
Warning light2 × 1.5 mm²Up to 20 m
AntennaRG58 coaxial cableRecommended: less than 5 m
Photocell transmitter TX2 × 0.25 mm²Up to 30 m
Photocell receiver RX2 cables, 2 × 0.25 mm² eachUp to 30 m
Key switch2 cables, 2 × 0.25 mm² eachUp to 50 m
Fixed / moving safety edgeDepending on the edge and interfaceDepending on the specific device

Two 2 × 0.25 mm² cables can be replaced with one 4 × 0.25 mm² cable. For a supply cable longer than 30 m, use a larger conductor cross-section and appropriate grounding. For low-voltage photocell wiring longer than 30 m, the instructions require shielding grounded at the control unit end only. Cables must be suitable for the environment; for outdoor installation, the manufacturer specifies, for example, H07RN-F.

A moving safety edge needs a connection that remains functional while the gate leaf is moving. Choose the number of conductors and the interface according to the type of safety edge; the two-core example from an older typical setup is not suitable for every OSE edge.

Mindy A500 wiring and terminal voltages

Make connections with the power disconnected. Terminals 13–14 and 8–9 provide 24 V AC, so they have no DC +/− polarity. COMMON 15 is the common point for the control inputs; do not confuse it with protective earth (PE). The control contacts are volt-free.

Mindy A500 – original wiring diagram for a three-phase 400 V motor

TerminalFunction and connection
Power supply R / S / TThree-phase 400 V supply via suitable protective devices; select the A500 power supply as shown in the diagram.
1–2 LAMPOutput for a 230 V AC warning light, max. 40 W; no +/− polarity.
3–4–5 MOTORMotor conductors U–V–W; these are not DC positive and negative.
6–7 PEProtective earth for the control unit and motor.
8–9 PHOTOTEST24 V AC for tested photocell transmitters, max. 200 mA; no +/− polarity.
10 / 11 / 12FCA open / common / FCC closed.
13–14 accessories24 V AC, max. 200 mA; without phototest, the instructions allow up to 400 mA.
15 COMMONCommon point for the control and safety inputs.
16 SCAOpen-gate indicator between 15–16: 24 V AC, max. 2 W.
17 ALT / STOPNC safety stop input referenced to 15.
18 PHOTOPhotocell NC contact referenced to 15 in standard wiring without phototest.
19 P.P.NO step-by-step contact referenced to 15: open – stop – close – stop.
20 AP / 21 CHNO open / close, referenced to 15.
41–42Volt-free output for the second radio channel, if a receiver is installed.
43–44 antennaCoaxial cable as shown in the diagram: shield to 43, centre conductor to 44.
RADIO / PIUOlder radio receiver connector / PIU expansion card socket.

NC means the contact is closed at rest; NO means it is open at rest. Multiple NC contacts with the same function are wired in series; NO control contacts are wired in parallel. Unused NO inputs are left unconnected. Safety devices required for safe operation must not be disabled by bridging them.

Photocells and A500 phototest

Original NICE BF can be replaced during a system upgrade with relay-type NICE EPM. EPM and EPMB do not use the same wiring: A500 does not have BlueBUS. For this control board, choose photocells with a suitable power supply and a volt-free NC contact.

Choose the photocell range according to the width of the passage. EPM has a useful range of 15 m; the manufacturer specifies a maximum of 30 m. For a TX–RX distance greater than 10 m, adjust the jumper +10m on the RX receiver as instructed for the EPM. Fog, rain and dust can reduce the range by 50%, so the 30 m maximum does not guarantee reliable coverage across a passage of the same width. Choose a suitable model for the specific location and check that it works correctly.

EPM wiringA500
Power supply without photocell testingTX and RX terminals 1–2 → output 13–14 (24 V AC). With AC, there is no +/− polarity.
Safety contact without photocell testingRX 4 COM → A500 15 COMMON; RX 5 NC → A500 18 PHOTO. RX 3 NO is not used for the safety function.
Photocell testPower TX from 8–9 and RX from 13–14; the contact connections and unused PHOTO inputs must match the original diagram below. Switch DIP 7 on.
Multiple pairsFor the same safety function, suitable NC contacts can be connected in series. A PIU card adds a separate PHOTO2 function, for example, to protect during opening.

NICE EPM – power supply 1–2, NO 3, COM 4 and NC 5; for DC, 1 + and 2 −

The EPM detail shows the power supply 24 V DC: 1 positive, 2 negative. However, the A500 supplies this pair with 24 V AC, with no +/− polarity, as shown in the table above. The relay contact numbers 3 NO / 4 COM / 5 NC remain the same.

A500 – PHOTO photocell test and optional PHOTO2 on the PIU card

PHOTO2 in the diagram requires a NICE PIU card. When photocell testing is enabled, connect the unused PHOTO input to the photocell test output as specified in the manual 9, not as shown in the diagram without testing. When using multiple EPM pairs, prevent interference between them as described in their manual; synchronization requires an AC power supply, modifying SYNC on TX, and reversing the power supply wires on one pair. After installation, test each pair separately.

Initial startup and direction check

  1. Move the gate manually to approximately the midpoint of its travel, engage the drive, and check the access door and safety microswitch. For initial tests, select a mode requiring the operator to be present, with additional functions switched off.
  2. When switched on, the OK LED should flash regularly. With the safety circuit closed, the STOP and PHOTO LEDs are lit; FCA and FCC are also lit when the gate is not at its end positions. The control NO inputs are not lit when no command is being given.
  3. Briefly activate AP / OPEN at terminal 20. The gate should open. If it moves in the opposite direction, switch off the power immediately; swap the motor wires at 3 and 4 as directed in the motor manual, then repeat the test.
  4. Before the gate is fully open, check that the open limit switch stops the movement. If the wrong limit switch is activated, switch off the power and check the FCA/FCC assignments; the manual specifies swapping 10 and 12.
  5. Test full opening and closing, bracket adjustment, run-on, and all safety devices. Only then set the desired operating mode.

A500 settings

DIPFunction
1 OFF / 2 OFFMovement only while the control is held – hold-to-run mode.
1 ON / 2 OFFSemi-automatic mode.
1 OFF / 2 ONAutomatic mode with automatic closing afterward.
1 ON / 2 ONAutomatic mode + always closes, even after power is restored.
3 ONCondominium mode; not in manual mode.
4 ONPre-flashing: 5 s, or 2 s in manual mode.
5 ONCloses 5 s after the photocell is cleared; automatic mode only.
6 ONPHOTO is also active during opening.
7 ONPhotocell test; requires the corresponding wiring.
8 ONIntelligent overload detection.
9 ONBrief 1.5 s reversal after overload; not in manual mode.
10 ONElectric braking when stopping, with the motor powered for 1 s.

ComponentWhat it adjusts
TLTravel time in one direction, approximately 3–120 s. For long travel, the manual describes the TLM extension to approximately 90–210 s; make the modification according to the exact control board.
TPPause before automatic closing, approximately 5–200 s.
FMotor-current threshold for safety-device activation. Verify the setting by measuring forces, not by trying to push the gate by hand.

Set TL to cover the full travel time, with approximately 2–3 s to spare. A 30 m gate takes approximately 3 minutes to travel in one direction at its rated speed, so the basic time range may not be sufficient. A500 overload detection is inactive during the first 1.5 s of movement; safety equipment and testing are therefore essential. DIP 10 electric braking does not replace checking the mechanical brake and run-on.

Receiver and remote controls

A500 uses an older connector from the FLOXI family.. For FloR rolling-code operation, for example, use the NICE FLOXI2R. The receiver type determines which NICE remote controls are supported and how they are programmed. The NICE brand and 433.92 MHz frequency alone do not guarantee a matching protocol. FLO fixed code and FloR rolling code are not interchangeable.

Insert the receiver only when the power is off. Program a new remote control into the receiver according to its label; the A500 DIP switches control gate functions. If a receiver is already installed, first check its type and memory. A mass delete may also remove other users’ remote controls.

Accessories for TUB3500

ComponentSelection
Flashing lightNICE ELAC for 230 V AC output 1–2, max. 40 W; ELDC cannot be connected directly here.
PhotocellsNICE EPM with an NC relay contact; the original BF are older equipment.
ExpansionNICE PIU adds PHOTO2, partial opening, and other functions. It is not designed for DPRO500.
RadioNICE FLOXI2R depending on the coding used. The modern SM connector is not the same as the older FLOXI slot.
Rack and safety edgesModule 6 rack, safety edges, and signal transmission, depending on the specific gate and control unit.

When the TUB3500 does not work properly

SymptomCheck
LEDs are offPower supply, main switch, circuit protection, and fuses. Identify and correct the cause of the circuit protection tripping before switching it on again.
OK flashes regularly every 1 sThe control logic is active. Two short flashes indicate a change to an input or switch.
OK flashes irregularlyAn internal check has detected an error; check the wiring and control unit.
STOP, PHOTO, or a limit switch input is preventing movementObstacle, photocell alignment, open access door, contact or cable; do not bypass the safety circuit.
Cannot start during the photocell testTX power supply 8–9, RX 13–14, contact wiring, DIP 7 setting, and interference between pairs.
Motor moves in the opposite directionCheck the motor direction and FCA/FCC as described under initial startup. Make adjustments only with the power off.
Stops midway along the travelTL/TLM time, friction, an obstacle, overload protection, or thermal protection. First identify and correct the cause; do not automatically increase force F.
Excessive overrunAdjust the brackets and mechanical brake; test again after the unit has warmed up.
Only the remote control is not workingTransmitter battery, code type and storage, receiver, and antenna.

Safety, testing, and maintenance

Before handover, repeatedly test opening, closing, stopping, limit switches, all photocells, safety edges, and the emergency stop. Check the overrun and the safety of the entire travel path; if protection relies on limiting impact force, carry out the corresponding measurement as well. Adjusting the trimmer or wiring a photocell alone does not replace testing the entire gate.

Carry out servicing no later than every 6 months or after 10,000 operations, whichever comes first. An operation is one opening or one closing, not a full opening–closing cycle. Check the fastenings, corrosion, wear on the pinion and rack, moving gate parts, mechanical brake, overload detection, and safety devices.

With the power off, users may remove leaves and stones from the travel path and gently clean accessible surfaces and photocell optics with a damp cloth. If the gate makes unusual noises, jerks, or malfunctions, take it out of service and contact a service technician. Do not bypass safety inputs. Keep remote controls out of children’s reach, and enter the passage only after the gate has fully opened and stopped. An open wicket gate in the gate leaf must disable the motor.

TUB3500 technical specifications

ModelNICE TUB3500
Control unitMindy A500
Power supply3~ 400 V AC ±10 %, 50 Hz
Max. power consumption550 W
Rated torque190 Nm
Peak torque418 Nm
Speed at rated torque0.167 m/s (approximately 10 m/min)
Max. gate weight / length3,500 kg / 30 m; suitability depends on operating conditions
Number of cyclesAccording to the length table; max. 200 cycles/day
PinionZ = 18; module 6; tooth pitch 18.8 mm
Protection ratingIP44
Insulation classI; protective earthing required
Operating temperature−20 to +50 °C
Mounting dimensionsDrawing in mm: height 580, width 480, body depth 230, depth to pinion 305
Weight60 kg

Technical values apply at an ambient temperature of 20 °C ±5 °C. When selecting spare parts and a control unit, provide the exact model and version shown on the rating plate.

Help choosing and completing your setup

Contact us with the gate’s length and weight, the number of cycles per hour and per day, the available power supply, and a photo of the installed control unit. We can help you choose a rack, receiver, and safety accessories.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Tub TUB3500 (A) – standalone drive for sliding gates

Product: NICE Tub TUB3500 (A) – standalone drive for sliding gates
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.