NICE Toona TO5016 - single actuator for swing gates, for a gate leaf up to 5 m/500 kg
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
for the question
€339.18 including VAT
| Weight |
|---|
| 7,00 kg |
Description of NICE Toona TO5016 - single actuator for swing gates, for a gate leaf up to 5 m/500 kg
- Non-reversible
- 230V
- Slow
- With microswitch stops for opening and closing
Application range
For a gate leaf weighing up to 500kg and measuring up to 5m in length, according to the following application graph:
Compatible control units
Technical specifications
| Power supply | 230V |
|---|---|
| Current draw | 1,5A |
| Power | 340W |
| Speed | 0,013m/s |
| Force | 1800N |
| Cycles/hour* | 54 |
| Protection rating | IP44 |
| Operating temperature | -20°C to +50°C |
| Dimensions | 965x115x105mm |
| Weight | 7kg |
* with optimal installation
I. Installing the rear mounting bracket
![]() |
![]() |
| Inward-opening diagram | Outward-opening diagram |
Calculate the position of the rear bracket using the graph, from which you can determine dimensions A and B and the maximum opening angle. Note that the values A and B must be similar (ideally identical) to allow the operator to move smoothly in a straight line.
![]() |
![]() |
| Calculation graph | Example of reading values from the graph |
Calculation procedure:
- Measure the distance C from the diagram
- On the graph draw a horizontal line that crosses the measured value C
- Where this line crosses the DIL (Recommended Installation Line) you can determine the maximum opening angle
- If the intersection is below level t, adjust the values to move the intersection above this level
- If the intersection is above level t, everything is fine, but if the specified maximum opening angle is unsuitable, you will need to adjust the value of A and, if necessary, the value of B, so they are similar (ideally identical)
Before fixing the bracket to a post or wall, shorten it to the required length corresponding to dimensions A and B and weld it to the mounting plate.
![]() |
![]() |
| 1. Cut the bracket to the required length | 2. Weld the shortened bracket to the mounting plate |
The supplied package includes a 150 mm bracket. If you need a longer bracket for special applications or need the gate to open outward, we recommend ordering the extended NICE PLA6 bracket.
If everything fits, secure the rear bracket to the post or wall using screws, wall plugs and washers.
II. Installing the front mounting bracket
The front bracket must be fitted to the gate leaf at a distance based on the values D and E, which you can determine from the Tables (value D is fixed and that is 880 mm):
| A | 100 | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| E | 780 | 770 | 760 | 750 | 740 | 730 | 720 | 710 | 700 | 690 | 680 | 670 | 660 | 650 | 640 | 630 | 620 | 610 | 600 |
The supplied package includes a bracket for welding. If you would prefer a screw-on bracket, we recommend ordering the alternative NICE PLA8 screw-on bracket.
- Calculate from the table the value E
- Calculate the height according to the diagram of the bracket heights (view image)
- Attach the bracket to the gate leaf (if welding the bracket, we recommend tack-welding it for now only)
III. Installing the gate operator on the rear bracket
![]() |
|
IV. Installing the gate operator on the front bracket
![]() |
|
V. Adjusting the mechanical travel stop
If using the operator's internal mechanical travel stop, which stops the operator when opening, external ground stops are not required. Adjust as follows:
![]() |
|
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]