NICE Toona TO4605 - single gate operator for swing gates with a leaf width of up to 3 m and weight of up to 500 kg


Product availability: for the question

The product may not be available, contact us for more information.


NICE Toona TO4605 - single gate operator for swing gates with a leaf width of up to 3 m and weight of up to 500 kg NICE Toona TO4605 - single gate operator for swing gates with a leaf width of up to 3 m and weight of up to 500 kg
NICE-TO4605
for the question
€253.61 excluding VAT
€311.94 including VAT

 pcs
Weight
6,00 kg

Description of NICE Toona TO4605 - single gate operator for swing gates with a leaf width of up to 3 m and weight of up to 500 kg

  • Reversible
  • 230V
  • Fast
  • With microswitch limit stop for opening

Application range

For a gate leaf weighing up to 500kg and measuring up to 3m, according to the following application chart:

NICE Toona 4 operator application limits

Compatible control units

Technical specifications

Power supply 230V
Current draw 1,3A
Power 300W
Speed 0,016m/s
Force 1800N
Cycles/hour* 50
Protection rating IP44
Operating temperature -20°C to +50°C
Dimensions 820x115x105mm
Weight 6kg

* under optimal installation conditions

I. Installing the rear mounting bracket

Diagram of the NICE Toona operator opening inward Diagram of the NICE Toona operator opening outward
Diagram of inward opening Diagram of outward opening

 

Calculate the position of the rear bracket using the chart, from which you can determine dimensions A and B and the maximum opening angle. Note that values A and B must be similar (ideally identical) to ensure the operator moves smoothly in a straight line.

NICE Toona TO4605 operator installation chart Illustrative example of calculating NICE Toona operator installation dimensions 
Calculation chart  Example of reading values from the chart 

 

Calculation procedure:

  1. Measure the distance C from the diagram
  2. On the chart draw a horizontal line that crosses the measured value C
  3. The intersection of this line with the DIL (Recommended Installation Line) gives you the maximum opening angle
  4. If the intersection is below level t, you will need to adjust the values to move the intersection above this level
  5. If the intersection is above level t, everything is fine, but if the specified maximum opening angle is unsuitable, you will need to adjust the value of A and, if necessary, the value of B, so that they are similar (ideally identical)

Before attaching the bracket to the post or wall, cut it to the required length corresponding to dimensions A and B and weld it to the mounting plate.

Cut the bracket to the required length Weld the shortened bracket to the mounting plate
1. Cut the bracket to the required length 2. Weld the shortened bracket to the mounting plate

 

The supplied package includes a 150 mm-long bracket. If you need a longer bracket for special applications, or need the gate to open outward, we recommend ordering the extended NICE PLA6 bracket.

Before attaching the rear bracket, check that the front bracket will line up with a solid part of the gate leaf, as there is a height difference between the front and rear brackets, as shown in the illustration.

 

Difference F=44mm.

Height difference between the front and rear brackets

If everything checks out, attach the rear bracket to the post or wall using screws, wall plugs and washers.

II. Installing the front mounting bracket

The front bracket must be fitted to the gate leaf at a distance based on values D and E, which you can find in the table (value D is fixed at 730 mm):

A 100 110 120 130 140 150 160 170 180 190 200 210
E 630 620 610 600 590 580 570 560 550 540 530 530

 

The supplied package includes a bracket for welding. If you would prefer a screw-on bracket, we recommend ordering the alternative NICE PLA8 screw-on bracket.

  1. Calculate from the table the value E
  2. of the bracket heights ( image bracket heights (view image)
  3. Attach the bracket to the gate leaf (if welding the bracket, we recommend tack-welding it for now only)

III. Mounting the gate operator on the rear bracket

Mounting the NICE Toona operator on the rear bracket
  1. Attach the motor to the bracket as shown in the image, using the supplied rear-bracket pin, washer and nut.
  2. Tighten the nut fully, then loosen it by 1/10 of a turn so that the gate operator can rotate

 

IV. Mounting the gate operator on the front bracket

Mounting the NICE Toona operator on the front bracket
  1. Attach the operator to the bracket as shown in the image, using the supplied pin and washer.
  2. Tighten the pin fully

 

V. Adjusting the mechanical travel stop

If using the internal mechanical travel stop, which the operator contacts when opening, there is no need to use external ground stops. Adjust it as follows:

Adjusting the mechanical travel stop on the NICE Toona operator
  1. Release the operator as described in the operator release instructions
  2. Loosen the mechanical stop screw
  3. Manually move the gate leaf to the required open position
  4. Move the entire mechanical stop up to the pin and tighten the screw as shown in the image
  5. If both are used, repeat steps 2–4 for the front stop (opening stop) and the rear stop (closing stop) mechanical stop
  6. Manually move the gate leaf to the closed position and lock the operator

 

 

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Toona TO4605 - single gate operator for swing gates with a leaf width of up to 3 m and weight of up to 500 kg

Product: NICE Toona TO4605 - single gate operator for swing gates with a leaf width of up to 3 m and weight of up to 500 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.