NICE Sumo SU2010 - drive for sectional/overhead doors up to 35 m², IP54


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE Sumo SU2010 - drive for sectional/overhead doors up to 35 m², IP54 NICE Sumo SU2010 - drive for sectional/overhead doors up to 35 m², IP54
NICE-SU2010
within 3 days
€568.86 excluding VAT
€699.70 including VAT

 pcs
Weight
10 kg

Description of NICE Sumo SU2010 - drive for sectional/overhead doors up to 35 m², IP54

NICE SUMO SU2010 is a shaft-mounted operator for sectional garage doors or suspended sliding gates, including those with two counter-moving leaves. It features a 24 V DC motor, magnetic encoder, torque of 120 Nm and a speed of up to 16 rpm. The maximum sectional door area is 35 m².

SU2010 does not include a control unit. For a balanced sectional door, add separately NICE DPRO924. Connect the 230 V AC mains supply to the control unit, not directly to the motor. The operator is non-backdrivable and is released in the event of a power failure using a steel cable inside a Bowden cable.

Quick navigation
Operator selectionAccessories
Package contentsInstallation
Manual releaseWiring
Initial setupSettings
Remote controlsDiagnostics
ResetMaintenance
SpecificationsPDF manual

Control unit and accessories

The wiring, setup and configuration below apply to SU2010 with DPRO924 and an incremental encoder on a balanced sectional door. A suspended sliding gate requires a control system and safety equipment designed specifically for it. For an older installed A924, use its own terminals and manual.

WhatWhyType
Control unitRequired for the motor and safety devices; wiring.
Photoelectric cellsStandard NC relay output, Phototest wiring.
Flashing lightSeparate 24 V flashing light on OUT1.
Radio receiver and remote controlSM slot, selection and pairing.
Backup batteryEmergency power supply for DPRO924 after programming.
Mounting drive adapterDirect adapter or chain, depending on the installation.

DPRO924 does not have BlueBUS: EPMB photoelectric cells are not direct replacements for EPM relay photoelectric cells. The PS124 battery used with SOON operators is not a backup battery for DPRO924.

When to choose SUMO SU2010

SU2010 is suitable for larger, mechanically balanced doors in commercial and industrial applications. Selection depends on operating resistance, drums, shaft, drive ratio and the required number of operating cycles.

ConditionWhat it means
Area up to 35 m²Maximum limit for a sectional door; it does not automatically determine the weight or length of a suspended gate leaf.
Torque: 120 NmAssess the torque required at the shaft for the entire door, including start-up.
Speed: 7.5–16 rpmMotor speed range; door speed depends on the drum and any reduction gearing.
Duty cycle: 50%This does not mean continuous operation without breaks or a universal number of cycles per hour.
IP54 ratingProtect the motor from flooding and unsuitable environments; the separate DPRO924 has an IP55 rating when its enclosure is properly closed.

SU2010 operator and separate control unit

SUMO SU2010DPRO924
NICE SU2010
NICE SUMO SU2010
IP54; 120 Nm; up to 35 m².
NICE DPRO924
NICE DPRO924 control unit
Sectional door control; motor sold separately.

SUMO SU2010 package contents

Standalone motor with encoder, mounting bracket, connecting key, installation hardware, and manual release with steel cable in a Bowden sheath and an operating handle. DPRO924, radio receiver, photocells, and chain drive are not included with the motor as standard.

NICE SUMO motor, bracket, and supplied installation hardware

Installing the drive

Disconnect the mains supply and backup battery before working on the unit. The door must be mechanically safe and properly balanced, with functioning springs, tracks, and stops. The drive will not fix a door that is difficult to move.

Direct shaft mounting

The NICE SUMO SU2010 drive mounts directly on the sectional door shaft Ø 25.4 mm. For shafts Ø 31.75 / 35 / 40 mm, use NICE CRA9. The mounting bracket is included; choose wall anchors to suit the substrate. The Ø 25.5 mm opening in the motor does not indicate a different recommended shaft diameter.

  1. Remove the cover, prepare the cable glands and hold the release lever in place during installation; secure it in the installation position as shown.
  2. Slide the motor onto the shaft, aligning the grooves. Insert the connecting key and prevent it from slipping out with a suitable collar.
  3. Bolt the bracket to the drive and anchor it to the wall so that the drive remains parallel to the wall.
  4. Release the installation lock on the release lever, return it to the operating position, and check the cover and release mechanism.

For a steel structure, use M8 screws, grade 6.8 or A2-50. Anchoring into other substrates must safely withstand a tensile load of 1,000 N; select the anchor type to suit the structure.

SUMO: cable glands, release lever installation position, key, and bracket
SUMO: cable glands, release lever installation position, key, and bracket

Off-shaft installation using a chain

When there is not enough room for direct mounting, use a shaft with an 18-tooth sprocket NICE CRA1 in the drive and a sprocket on the door shaft. The drive is connected by a 1/2″ × 5/16″ chain NICE CRA3 (1 m) or NICE CRA4 (5 m), with a connector NICE CRA2. For mounting the drive off-axis, use brackets NICE CRA8.

Drive ratioComponents and result
1 : 1NICE CRA1 + NICE CRA7 (18 / 18 teeth). No speed reduction.
1 : 2NICE CRA1 + NICE CRA6 (18 / 36 teeth). The door shaft rotates more slowly; the transmitted torque and door structure must be assessed.

The sprockets must be aligned in the same plane, the chain correctly tensioned, and the chain guarded against fingers or clothing getting caught. Changing the drive ratio does not automatically change the permitted door area. Dimensions, balance, travel, and the complete assembly must be assessed together.

Position the chain at least 2.4 m above the floor and out of reach; if this is not possible, fit a protective guard. Under a load of 4,000 N, the shaft supporting the sprocket must deflect no more than 2 mm.

SUMO: vertical CRA1, CRA6, or CRA7 chain drive and CRA8 brackets
SUMO: vertical CRA1, CRA6, or CRA7 chain drive and CRA8 brackets

Chain arrangement for a suspended sliding gate

For a suspended gate, the chain loop consists of a shaft with a sprocket NICE CRA1, a tensioner with an idler sprocket NICE CRA5, a chain NICE CRA4 and connectors NICE CRA2. Attach the gate leaf to the upper or lower chain run, depending on the direction of travel. For two opposing leaves, attach one to the upper run and the other to the lower run.

This is a custom-designed chain assembly. The sectional door area limit does not determine the permitted weight or length of a suspended gate leaf. Check the sliding resistance, force transmission, travel path, mechanical stops, and protection of crush points.

Suspended gate chain loop and NICE CRA5 tensioner

SUMO: installing a horizontal chain loop for a suspended gate
SUMO: installing a horizontal chain loop for a suspended gate

SU2010 manual release

The SU2010 has a steel cable in a Bowden sheath, routed to an operating handle near the floor. Route the Bowden sheath as straight as possible; the maximum length is 6.5 m. Release only a stationary, balanced door. Do not release the door if a spring is damaged or if the door could fall.

Installing and adjusting the cable

  1. With the power disconnected, remove the cover, fold down the release lever, and secure it with the installation screw. Insert the end of the Bowden sheath without a ferrule into the PG7 cable gland.
  2. Feed the steel cable through from the opposite side. Secure the Bowden sheath with a clip. Place the cable in the lever's outer groove and firmly secure its end with a clamp; it must not slip out when pulled hard.
  3. After installing the motor, release the lever's installation lock, return the lever to its operating position, and close the cover. Run the Bowden sheath along the wall without sharp bends.
  4. Fit the clamp and operating handle onto the cable. Set their height as shown; when the handle is moved to position 1, the drive must disengage reliably.

SU2010: Bowden sheath fixing, steel cable clamp, and operating handle near the floor
SU2010: Bowden sheath fixing, steel cable clamp, and operating handle near the floor

Manual movement and re-engagement

  1. Move the handle down to position 1 as shown.
  2. Move the door by hand without forcing it.
  3. Return the release mechanism to the engaged position and check that the drive has re-engaged.

For outside access, the installation may also include NICE KA1 and NICE KIO or NICE KIOMINI. They are not automatically included with the standalone drive.

After manual movement, SU2010 with DPRO924 needs to restore position synchronization. If the control unit remained powered during unlocking, it will record the unlock event. Synchronization is restored by moving to the stored fully closed position; until then, the gate opens only while the command is held. Keep the gate in sight and do not bypass safety devices.

Wiring SU2010 with DPRO924

Disconnect both the mains and PS224 before working. The motor cable and encoder cable are separate circuits. DPRO924 controls one SU2010 on a balanced sectional door; the procedures below do not apply to a chain-operated suspended door.

DPRO924: motor, incremental encoder, commands, relay photocells, warning light and safety circuit
DPRO924: motor, incremental encoder, commands, relay photocells, warning light and safety circuit

Wiring and cable lengths

ConnectionCable / maximum length
Mains supply to DPRO9243 × 1.5 mm² / 30 m. For longer runs, use 3 × 2.5 mm² and provide protective earthing at the automation unit.
Motor3 × 2.5 mm² / 10 m; depending on the motor terminals and protective wiring.
Incremental encoder2 × 1 mm² / 10 m; route separately from power cables.
Warning light2 × 0.5 mm² / 20 m.
Photocells4 × 0.5 mm² / 20 m; specific branches depend on the wiring diagram selected.
Command switch2 × 0.25 mm² / 20 m or 4 × 0.5 mm².
AntennaRG58 / 10 m maximum, 5 m or less recommended.

Terminals and accessory polarity

DPRO924 terminalFunction / connection
MOTOR 1 / 2 / 31 and 2 – 24 V DC motor output; 3 – protective earth. The polarity at the motor output changes with the direction of movement. Do not connect 230 V mains power to the motor terminals.
Incremental encoderTwo encoder signal wires; non-polarized. Not an auxiliary power supply.
GND (1) / 24 V (2)1 GND = negative (−), 2 24 V = positive (+); 24 V DC −30% / +50%, maximum 200 mA total for accessories.
Phototest (3)Tested positive supply for TX: 3 = positive (+), GND 1 = negative (−); 24 V DC, −30% / +50%, max. 200 mA at the Phototest output.
Common / COM SBYPositive common terminal for commands, 24 V DC. Common for SbS remains active; COM SBY for Open/Close/Photo/Photo2 switches off in Total Stand-by mode. It is not GND.
SbS / Open / CloseVoltage-free NO contacts: SbS to Common, Open and Close to COM SBY. The contacts themselves are non-polarized.
Photo / Photo2Voltage-free NC photocell contact; the common terminal connection depends on Phototest or Stand-by mode.
STOP Safety Edge8.2 kΩ resistive or optical OSE safety edge. OSE: +12 V = positive, GND = negative, SIG = signal.
ALTNC safety circuit. An open contact prevents operation.
OUT1 / OUT2 / OUT3OUT1 – 24 V warning light up to 25 W with independent flashing; OUT2/3 – voltage-free relay contacts for resistive loads up to 3 A. Do not assign fictitious +/− polarity to OUT2/3 contacts.
LIGHT on the cover board1 = negative (−), 2 = positive (+), 24 V DC, maximum 5 W; cable up to 2 m. The output is not short-circuit protected.

Terminal block directly in the SU2010

SU2010: 1/2 are for the motor, 3/4 for the encoder. Connect 1/2 to the DPRO924 motor output and 3/4 to the Incremental encoder input. Label Motor terminal 3 is not PE. According to the SU2010 wiring diagram, the third conductor of the three-core motor cable is safely insulated at the motor end. Protective earthing for the DPRO924 mains supply is still mandatory.

SUMO SU2010: motor terminals 1/2 and encoder terminals 3/4; third motor-cable conductor safely insulated
SUMO SU2010: motor terminals 1/2 and encoder terminals 3/4; third motor-cable conductor safely insulated

EPM photocells with Phototest

DPRO924 uses NICE EPM with a standard relay output. For the safety function, connect on the EPM 4 COM and 5 NC; contact 3 NO is not the correct safety contact.

DevicePower supply and contact
TX EPM1 = positive (+), 2 = negative (−). In Phototest mode: TX 1 → Phototest (3) DPRO924, TX 2 → GND (1) DPRO924.
RX EPM1 = positive (+), 2 = negative (−). RX 1 → 24 V (2) DPRO924, RX 2 → GND (1). RX 4 COM → 24 V (2) DPRO924, 5 NC → Photo or Photo2 depending on the protected area. Contact 4/5 is voltage-free.
Two pairsConnect each to the correct input. If they interfere with each other, reposition them or use suitable optical shields. EPM synchronization via SYNC requires AC power; do not use it blindly with the control unit’s DC output.

EPM: TX/RX supply 1 (+), 2 (−), relay contacts 4 COM and 5 NC
EPM: TX/RX supply 1 (+), 2 (−), relay contacts 4 COM and 5 NC

DPRO924: RX to GND/24 V and TX to GND/Phototest
DPRO924: RX to GND/24 V and TX to GND/Phototest

Phototest checks the photocells before movement. After wiring it, teach in the safety devices. Unused Photo or Photo2 is jumpered to Phototest in this diagram; this does not replace the required gate safety protection.

Alternative: Total Stand-by

Total Stand-by is enabled via Oview; after the set time (factory setting: 1 min), it reduces power consumption by switching off accessories. TX and RX: terminal 1 (+) → COM SBY, 2 (−) → GND; RX 4 COM → COM SBY, 5 NC → Photo or Photo2. Phototest is not performed with this wiring. Unused Photo/Photo2 is jumpered to COM SBY. Do not combine the two wiring diagrams.

DPRO924: standalone alternative power supply for photocells with Total Stand-by
DPRO924: standalone alternative power supply for photocells with Total Stand-by

Safety edge and safety circuit

Connect the 8.2 kΩ resistive edge between SIG and GND, with no polarity. Optical OSE according to the markings: brown wire to +12 V, green to SIG, white to GND. If a different color scheme is used, follow the edge manufacturer's markings. With this resistive interface, connect NC contacts in series with the terminating 8.2 kΩ resistor and NO contacts in parallel with the resistor; the wiring must comply with the safety design. Repeat the learning procedure after making a change. The resistor must not be used to bypass a required safety device.

Warning beacon and status indicator

The OUT1 output NICE ELDC with a built-in flashing function, 24 V, max. 25 W. OUT1 is not an auxiliary GND/24 V pair; do not infer the polarity from other connectors. The ELDC power supply pair itself is not marked +/− in its wiring diagram. Connect the antenna to the radio receiver using its connector.

The status indicator on the cover board is separate: LIGHT 1 (−), 2 (+), 24 V DC / 5 W. It goes out when the safety circuit is open, flashes 0.5 s ON / 0.5 s OFF in normal operation, and follows the OK indicator signal when there is a fault. The cable must be no longer than 2 m, and the output is not short-circuit protected.

DPRO924: LIGHT 1 (−), 2 (+) on the cover button board
DPRO924: LIGHT 1 (−), 2 (+) on the cover button board

Backup power supply and service interface

NICE PS224 Connect it to the designated DPRO924 battery connector only after installation and programming are complete. The number of movements possible during a power failure is not fixed and depends on the gate and battery. Oview connects via IBT4N and allows you to adjust force, sensitivity and deceleration points, and perform diagnostics. Choose accessories for the DPRO924, not the older A924.

Initial commissioning of the DPRO924 with SUMO

On the cover board, the switches that enable the OPEN and CLOSE buttons must be set to ON; STOP remains active at all times. Before learning, the gate should be approximately 50 cm above the floor, so that the direction can be checked safely. The green OK indicator flashes about once per second; ALT/Photo/Photo2 must match the wiring.

1. Learning the safety devices

At least one safety device must be connected. Learn the devices and positions one after the other without interruption.

  1. Set A1 to ON; A2/A3/A4 to OFF.
  2. Hold STOP for about 3 s until the OK indicator stays red; then release it.
  3. When finished, set the switches to OFF and immediately continue by learning the incremental encoder.

2. Positions with an incremental encoder

  1. Set B2 OFF, B3 OFF; A1 ON, A2/A3/A4 OFF.
  2. Hold STOP for about 3 s until the indicator stays red, then release it.
  3. Press OPEN to move the gate to the required open position before the mechanical stop. Confirm by holding STOP for 3 s: one red flash.
  4. Press CLOSE to move the gate to the fully closed position. Confirm by holding STOP for 3 s: two red flashes.
  5. To set a custom partial-open position, press OPEN to move the gate to that position and confirm by holding STOP for 3 s: three red flashes. If no partial-open position is set, the factory default is 1/4 of the full travel; this can also be changed via Oview.
  6. Set A1 to OFF; select A3/A4 according to the operating mode and confirm by holding P1 for at least 2 s.

If OPEN closes the gate, stop, disconnect the mains and battery, swap the motor wires at outputs 1/2, and start the learning procedure again. Do not swap the encoder wires to change the direction.

3. Learning the forces

After learning the positions, perform complete opening and closing cycles without interruption until the unit stops flashing the OK indicator red and green alternately during movement. An interrupted cycle is not counted. During learning, the unit uses maximum force: the area must be supervised. Repeat force learning after changing the speed, deceleration points or sensitivity. Perform safety tests when finished.

The unit calculates the RA/RB deceleration points first. If you need to adjust them, use the Oview programmer, then repeat force learning and the safety tests.

DPRO924 operating mode settings

DPRO924: A1–A4 and B1–B3 switches on the main board
DPRO924: A1–A4 and B1–B3 switches on the main board

Switches A and B are on the main board. After changing them, the OK indicator may flash red and green alternately and the unit may reject commands: confirm the correct configuration by pressing P1 for 2 s, or repeat the safety device learning procedure. If these functions are set via Oview, the corresponding DIP switches must be OFF.

Safety equipment by operating mode

When operating in hold-to-run mode, the operator must be able to see the gate, and the control device must be protected against unauthorized use. Semi-automatic operation requires an active safety edge; automatic closing requires both a safety edge and photocells. Assess the protection required at the specific crushing points and ensure that all safety requirements are met. Changing the DIP switch setting alone does not make an automation system safe.

DIP A – operation

SettingMeaning
A1 OFF, A2 OFF, A3 OFF, A4 OFFHold-to-run operation: movement only while the command is held.
A1 ON, A3/A4 OFFLearning the safety devices and positions. For SU2010, also set A2 to OFF.
A1 OFF, A2 OFF, A3 OFF, A4 ONIndustrial mode: semi-automatic opening, closing with hold-to-run control.
A1 OFF, A2 OFF, A3 ON, A4 OFFSemi-automatic operation after learning the positions.
A1 OFF, A2 OFF, A3 ON, A4 ONAutomatic closing with a stored pause time.
A2 ONReverse the absolute encoder direction; not used with the SU2010 incremental encoder.

DIP B – sensitivity, speed and motor

SwitchStatus and meaning
B1 – sensitivityOFF: disabled; ON: enabled. ON reduces the force applied when an obstacle is detected; after changing the setting, learn the forces and take measurements.
B2 – speed adjustmentOFF: normal operation; ON: speed adjustment mode, with the OK indicator flashing orange rapidly.
B3 – motor typeOFF for the SU2010 with encoder. ON for a motor with electromechanical limit switches.

Automatic closing – pause time

  1. After learning the positions, set A3/A4 to ON and A1/A2 to OFF.
  2. Hold P1 for at least 2 s.
  3. Send an OPEN command and wait until the gate is fully open.
  4. From this point, wait for the required pause and send CLOSE. The time will be stored.

To change the pause, set A4 to OFF and confirm with P1 for 2 s; this cancels the original pause. Then set A4 to ON, confirm with P1 for 2 s, and repeat the opening, waiting and closing sequence.

Movement and deceleration speed

Opening, decelerated opening, closing and decelerated closing are set separately. You can use Oview or the board buttons:

  1. Set B2 to ON; OK flashes orange rapidly.
  2. Hold P1 and send OPEN or CLOSE, depending on the direction you want to change.
  3. While holding P1, change the current section: OPEN increases the speed by 5% per press; CLOSE decreases it by 5%.. Green OK indicates a normal section; red indicates deceleration.
  4. Release P1; to adjust the next movement, start again by holding it down.
  5. Set B2 back to OFF, complete force learning and carry out the tests.

Current monitoring is disabled while P1 is held. Keep the gate under supervision during this procedure; do not use it to test force against an obstacle.

Remote control and antenna

The radio receiver plugs into the SM socket with both the mains and battery disconnected. Do not confuse the equipment supplied with a standalone drive with a complete kit: choose the receiver and transmitters to match the actual configuration supplied.

NICE OXIBD supports both unidirectional and bidirectional transmitters; a suitable unidirectional transmitter is the NICE MYGO4. An older installed receiver may use different coding. The same 433.92 MHz frequency is not sufficient on its own.

In standard Mode 1, the receiver outputs are: 1 – step-by-step, 2 – partial opening, 3 – opening, 4 – closing. Mode 2 lets you assign an individual button to a selected command. For exact pairing and deletion instructions, refer to the manual for the specific OXIBD receiver; the motor buttons do not erase its radio memory.

For the OXIBD, connect the antenna to the receiver connector according to the OXIBD antenna wiring diagram. Connect the coaxial cable's centre conductor to the signal terminal and the shield to the antenna ground. These are not the power supply +/− terminals.

On a receiver that supports extended Mode 2, command 13 – Unlock automation is used to cancel the electronic lockout. It does not release the mechanical drive; this must be manually disengaged using the cord.

DPRO924 diagnostics

After power-up, two slow green OK flashes indicate a motor with an incremental encoder. One slow red flash confirms a learned 8.2 kΩ safety edge; two flashes indicate OSE. Rapid green flashing after power-up may indicate that the memory has not been programmed.

Red OKCause and check
2 flashesPhotocell: obstruction, optics or relay wiring.
3 flashesForce, sensitivity or blocked encoder: check for mechanical resistance and inspect the encoder cable.
4 flashesSTOP/ALT or release: secure the motor and check the safety circuit.
5 flashesInternal parameters: press STOP on the cover and wait at least 30 s. If the fault persists, contact service; if necessary, perform a reset and relearn.
6 flashesThe limit on manoeuvres per hour has been exceeded. Wait a few minutes for the limiter to allow the next movement.
7 flashesInternal electrical fault: press STOP, disconnect all power sources, and have the board and wiring inspected by a qualified technician.
8 flashesContinuous input command: remove the cause of the stuck contact.
9 flashesAutomation electronically locked: use the command to unlock it electronically. This is not a manual release of the drive.

Other OK signal indicationsSolution
Red steady + 8 green flashesNo encoder signal. Press STOP and check the separate encoder cable.
Red steady + 10 green flashesMovement time exceeded. Press STOP and check the mechanism and positions; adjust the time via Oview.
Red/green alternating while idleDIP settings changed: check the configuration and confirm by holding P1 for at least 2 s.
Red/green alternating during movementForce learning in progress; complete the full manoeuvres.
Rapid orange flashingB2 is ON; complete the speed adjustment and set B2 to OFF.

Clearing DPRO924 memory

A reset erases the settings, positions and learned safety devices. The plug-in radio receiver's memory is separate.

  1. With the gate stationary, set A1/A2/A3/A4 to ON; OK flashes orange rapidly.
  2. Hold STOP for about 3 s until OK stays red; release it.
  3. After the reset, OK flashes orange rapidly. Set all DIP switches A back to OFF; OK flashes green.
  4. Set the correct motor type, repeat the safety device, position and force learning procedures, and carry out the tests.

Checks before handing over the gate

  1. With the drive disengaged, check that the gate moves smoothly and is balanced. Manual testing requires a force of no more than 225 N. This force is neither the motor's torque nor the permissible impact force.
  2. After engaging the drive, test opening, closing and STOP; the gate must not bind or strike beyond the stored end positions.
  3. Test each pair of photocells at the TX, at the RX and in the middle of the beam, for example with a cylinder Ø 5 cm and 30 cm long. Check the gate's actual response.
  4. Test the safety edge, safety circuit and emergency release. Measure impact forces with a suitable gauge; repeat the test after changing the force or sensitivity settings.
  5. Hand over the gate only after successful testing, with identification, release instructions and a maintenance plan. Pass through only when the gate is fully open and stationary.

Drive and gate maintenance

Disconnect both the mains and the battery before every scheduled inspection. Check the bracket, anchors, wedge, shaft, release mechanism, guide components and balance; for chain drives, also check tension, wear and whether lubrication is needed. Use the drive only with functioning mechanical stops and safety devices.

For normal domestic use, the manufacturer recommends a professional inspection every 6 months. Adjust the inspection interval for the complete assembly to suit the load and gate conditions; inspect and clean EPM photocells at least every 6 months. Repeat the tests after servicing. Spring or load-bearing cable faults must be dealt with by a professional, not by increasing motor force.

SUMO SU2010 technical specifications

ParameterValue
Control unitStandalone unit for a balanced sectional door NICE DPRO924; not included with the SU2010.
Motor power supply24 V DC; operating range 15–36 V DC.
Motor current draw / power consumption13 A DC / 500 W. This is not the current drawn from the 230 V mains.
Torque120 Nm.
Speed7.5–16 rpm; settings depend on the control unit and configuration.
Sectional door areaUp to 35 m².
Duty cycle50%.
Ingress protection / temperatureSU2010 IP54; −20 to +50 °C.
Shaft / boreShaft Ø 25.4 mm; bore in motor Ø 25.5 mm.
Dimensions / weight350 × 270 × 110 mm / 10.5 kg.
Motor insulation thermal classClass B.

SUMO SU2010 dimensions, shaft bore and bracket adjustment range
SUMO SU2010 dimensions, shaft bore and bracket adjustment range

DPRO924 power supply and limits

ParameterValue
Mains power supply230 V AC, 50/60 Hz; Class I, grounded.
Maximum mains power consumption500 W.
Accessory output24 V DC −30% / +50%, 200 mA; polarity and terminals.
Backup powerNICE PS224.
FusesF2 T2 A; F1 automotive 20 A. Same type and rating after the cause has been eliminated.
EnclosureIP55 when properly closed; 310 × 210 × 125 mm, approx. 4 kg.

360° drive view

 

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Sumo SU2010 - drive for sectional/overhead doors up to 35 m², IP54

Product: NICE Sumo SU2010 - drive for sectional/overhead doors up to 35 m², IP54
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.