NICE SUMO SU2000VV is a high-speed shaft-mounted operator for sectional garage doors and suspended sliding gates, including gates with two counter-moving leaves. It has a 24 V DC motor with a magnetic encoder, a torque of 46 Nm and a speed of 19.5–42 rpm. The sectional door area limit is 15 m².

The SU2000VV does not include a control unit. For a balanced sectional door, add separately NICE DPRO924, which powers the motor and controls the accessories. Connect the 230 V AC mains supply to the control unit, not directly to the motor. The operator is non-backdrivable and is released manually using the cord release.

The encoder tracks the operator's position; the open and closed positions must be learned. The gate must have mechanical stops and be properly balanced. The motor cannot compensate for damaged springs or a gate that is difficult to move.

Quick navigation
Choosing an operatorAccessories
Package contentsInstallation
Manual releaseWiring
Initial startupSettings
Remote controlsDiagnostics
ResetMaintenance
SpecificationsPDF manual

Control unit and accessories

The following wiring and setup instructions apply to the SU2000VV with DPRO924 and incremental encoder. For an older, installed A924, use its own terminals and manual; these control units do not have interchangeable wiring.

The DPRO924 wiring, learning procedure and settings below apply to a balanced sectional door. For a suspended sliding gate, choose a control unit designed for this application separately, and check the complete chain assembly.

WhatWhyType
Control unitRequired for the motor and safety devices; wiring.
PhotocellsStandard relay NC output, Phototest wiring.
Flashing lightStandalone 24 V flashing lamp on OUT1.
Radio receiver and remote controlSM socket, selection and pairing.
Backup batteryEmergency power supply for DPRO924 after programming.
Mounting adapterDirect adapter or chain, depending on the installation.

DPRO924 does not have BlueBUS: EPMB photocells are not direct replacements for relay-type EPM photocells. The PS124 battery from SOON operators is not a backup battery for DPRO924.

When to choose the SUMO SU2000VV

The SU2000VV is suitable where a mechanically balanced sectional door needs high speed and its required torque is within the operator's 46 Nm capacity. The door's speed depends on the drums and gearing; motor speed is not the gate speed in metres per second.

RequirementWhat it means
Area up to 15 m²Maximum area for a sectional door. The manufacturer lists this variant for areas of 10–15 m²; suitability for a specific door also depends on resistance, balance and required torque. This figure does not specify the weight or length of a suspended gate leaf.
Torque: 46 NmAssess the torque required at the shaft for the entire gate, including startup.
Speed: 19.5–42 rpmMotor speed range; gate speed depends on the drum and any reduction gearing.
Duty cycle: 50%A 50% duty cycle means intermittent operation with pauses, not continuous operation or a fixed number of cycles per hour.
IP44 ratingProtect the motor from flooding and unsuitable environments; the standalone DPRO924 has an IP55 rating when its enclosure is properly closed.

SU2000VV operator

SUMO SU2000VV
NICE SU2000VV
NICE SUMO SU2000VV standalone shaft-mounted operator
Sectional door up to 15 m².
46 Nm.
19.5–42 rpm
Highest speed; lower torque.

For these variants, higher speed means less available torque. All three are standalone 24 V DC motors without a control unit; for a sectional door, add NICE DPRO924. Compare the required shaft torque, not just the area or speed.

What’s included with the SUMO SU2000VV

Standalone motor with encoder, mounting bracket, drive key, installation hardware, and cable release with operating handle. The DPRO924, radio receiver, photocells, and chain drive are not automatically included with the motor.

NICE SUMO motor, bracket, and supplied installation hardware

Installing the operator

Disconnect the mains power and backup battery before starting work. The door must be mechanically safe and properly balanced, with functional springs, tracks, and stops. The operator will not fix a door that is difficult to move.

Direct shaft mounting

The NICE SUMO SU2000VV operator mounts directly on the sectional door shaft Ø 25.4 mm. For shafts Ø 31.75 / 35 / 40 mm, use NICE CRA9. The mounting bracket is included; choose wall anchors to suit the substrate. The Ø 25.5 mm opening in the motor does not indicate a different recommended shaft diameter.

  1. Remove the cover and prepare the cable glands. During installation, hold the release lever and secure it in the installation position as shown.
  2. Slide the motor onto the shaft, aligning the keyways. Insert the drive key and secure it against slipping out with a suitable collar.
  3. Screw the bracket to the operator and anchor it to the wall so that the operator remains parallel to the wall.
  4. Release the installation lock on the release lever, return it to the operating position, and check the cover and release mechanism.

For steel structures, use M8 class 6.8 or A2-50 screws. Anchoring into other substrates must safely withstand a tensile load of 1,000 N; select the anchor type to suit the structure.

SUMO: cable glands, release lever installation position, drive key, and bracket
SUMO: cable glands, release lever installation position, drive key, and bracket

Offset mounting using a chain

When there is not enough room for direct mounting, use a shaft with an 18-tooth sprocket NICE CRA1 in the operator and a sprocket on the door shaft. The drive uses a 1/2″ × 5/16″ chain NICE CRA3 (1 m) or NICE CRA4 (5 m), with connector NICE CRA2. Use NICE CRA8.

Drive ratioComponents and result
1 : 1NICE CRA1 + NICE CRA7 (18 / 18 teeth). No speed reduction.
1 : 2NICE CRA1 + NICE CRA6 (18 / 36 teeth). The door shaft rotates more slowly; assess the transmitted torque and door construction.

The sprockets must be aligned, the chain correctly tensioned, and protected against fingers or clothing getting caught. Changing the drive ratio does not automatically change the permitted door area. Dimensions, balance, travel, and the complete assembly must be assessed together.

Position the chain at least 2.4 m above the floor and out of reach; if this is not possible, fit a protective guard. Under a load of 4,000 N, the shaft carrying the sprocket must deflect no more than 2 mm.

SUMO: vertical chain drive with CRA1, CRA6, or CRA7 and CRA8 brackets
SUMO: vertical chain drive with CRA1, CRA6, or CRA7 and CRA8 brackets

Chain drive for a suspended sliding gate

For a suspended gate, the loop consists of a shaft with a sprocket NICE CRA1, a tensioner with return sprocket NICE CRA5, chain NICE CRA4 and connectors NICE CRA2. Attach the gate leaf to the upper or lower chain run, depending on the direction of travel. For two oppositely moving leaves, attach one to the upper run and the other to the lower run.

This is a custom-designed chain assembly. The sectional door area limit does not determine the permitted weight or length of a suspended gate leaf. Check the travel resistance, force transmission, travel path, mechanical stops, and protection of crush points.

Suspended gate chain loop and NICE CRA5 tensioner

SUMO: installing a horizontal chain loop for a suspended gate
SUMO: installing a horizontal chain loop for a suspended gate

Manual release and return to motorized operation

The SU2000VV uses the supplied nylon cable with handle for release from floor level; the cable run can be up to 6.5 m. Release only when the gate is stationary and balanced.

  1. Pull the handle down to position 1 as shown.
  2. Move the gate manually with care.
  3. Before operating the gate electrically, return the release mechanism to its original locked position and check that the drive is engaged.

SUMO SU2000VV: floor-level cable release, position 1 for manual operation
SUMO SU2000VV: floor-level cable release, position 1 for manual operation

External release is available separately: NICE KA1 (6 m steel cable) and NICE KIO or NICE KIOMINI. This does not replace the requirement to install the supplied release mechanism correctly; adapt the cable routing and mechanical connection to the operator.

With SUMO and DPRO924, position synchronization must be restored after manual movement. If the control unit was powered on while the drive was disengaged, it will record the disengagement. Restoration is completed by moving to the stored fully closed position; until synchronization is complete, open the gate while holding the command. Keep the gate in view while doing so, and do not bypass the safety devices.

Wiring the SU2000VV with DPRO924

Disconnect both the mains power and the PS224 before starting work. The motor cable and encoder cable are separate circuits. DPRO924 controls one SU2000VV motor on a balanced sectional door.

DPRO924: motor, incremental encoder, commands, relay photocells, warning light and safety circuit
DPRO924: motor, incremental encoder, commands, relay photocells, warning light and safety circuit

Wiring and cable lengths

Cable runCable / maximum length
Mains to DPRO9243 × 1.5 mm² / 30 m. For longer runs, use 3 × 2.5 mm² and connect protective earth at the automation unit.
Motor3 × 2.5 mm² / maximum 10 m; motor conductors as specified by the motor terminals, protective conductor according to the wiring diagram for the specific assembly.
Incremental encoder2 × 1 mm² / maximum 10 m; route separately from power cables.
Warning light2 × 0.5 mm² / 20 m.
Photocells4 × 0.5 mm² / 20 m; wire the individual branches according to the selected diagram.
Command switch2 × 0.25 mm² / 20 m or 4 × 0.5 mm².
AntennaRG58 / maximum 10 m, 5 m or less recommended.

Terminals and accessory polarity

DPRO924 terminalFunction / wiring
MOTOR 1 / 2 / 31 and 2 – 24 V DC motor output; 3 – protective earth. The polarity at the motor output changes with the direction of movement. Do not connect 230 V mains power to the motor terminals.
Incremental encoderTwo encoder signal wires; non-polarised. Not an auxiliary power supply.
GND (1) / 24 V (2)1 GND = negative (−), 2 24 V = positive (+); 24 V DC −30% / +50%, maximum 200 mA for all accessories combined.
Phototest (3)Tested positive supply for TX: 3 = positive (+), GND 1 = negative (−); 24 V DC, max. 200 mA at the Phototest output.
Common / COM SBYPositive common terminal for commands, 24 V DC. Common for SbS remains active; COM SBY for Open/Close/Photo/Photo2 is switched off during Total Stand-by. This is not GND.
SbS / Open / CloseVoltage-free NO contacts: SbS to Common, Open and Close to COM SBY. The contacts themselves are not polarised.
Photo / Photo2Voltage-free NC photocell contact; the common terminal wiring depends on Phototest or Stand-by mode.
STOP Safety EdgeResistive 8.2 kΩ or optical OSE safety edge. OSE: +12 V = positive, GND = negative, SIG = signal.
ALTNC safety circuit. An open contact blocks operation.
OUT1 / OUT2 / OUT3OUT1 – 24 V warning light up to 25 W with independent flashing; OUT2/3 – voltage-free relay contacts, up to 3 A resistive load. Do not assign fictitious +/− polarity to the OUT2/3 contacts.
LIGHT on the cover board1 = negative (−), 2 = positive (+), 24 V DC, maximum 5 W; cable up to 2 m. The output is not short-circuit protected.

Terminal block inside the SU2000VV

SU2000VV: terminals 1/2 are for the motor, 3/4 are for the encoder. Connect 1/2 to the DPRO924 motor output and 3/4 to the Incremental encoder input. Note Terminal 3 on the motor is not PE. According to the SU2000VV wiring diagram, the third conductor of the three-core motor cable is to be safely insulated at the motor end. Protective earth for the DPRO924 mains supply is still mandatory.

SUMO SU2000VV: motor terminals 1/2 and encoder terminals 3/4; the third motor cable conductor is safely insulated
SUMO SU2000VV: motor terminals 1/2 and encoder terminals 3/4; the third motor cable conductor is safely insulated

EPM photocells with Phototest

DPRO924 uses NICE EPM with a standard relay output. For the safety function, connect terminals on the EPM 4 COM and 5 NC; contact 3 NO is not the correct safety contact.

DevicePower supply and contact
TX EPM1 = positive (+), 2 = negative (−). In Phototest mode: TX 1 → Phototest (3) DPRO924, TX 2 → GND (1) DPRO924.
RX EPM1 = positive (+), 2 = negative (−). RX 1 → 24 V (2) DPRO924, RX 2 → GND (1). RX 4 COM → 24 V (2), RX 5 NC → Photo or Photo2. Contact 4/5 is voltage-free; do not use contact 3 NO.
Two pairsAssign each to the correct input. If they interfere with each other, change their positions or use suitable optical shields. EPM synchronisation via SYNC requires an AC power supply; do not use it blindly with the control unit’s DC output.

EPM: TX/RX power supply 1 (+), 2 (−), relay contacts 4 COM and 5 NC
EPM: TX/RX power supply 1 (+), 2 (−), relay contacts 4 COM and 5 NC

DPRO924: RX to GND/24 V and TX to GND/Phototest
DPRO924: RX to GND/24 V and TX to GND/Phototest

Phototest checks the photocells before movement. After wiring it, teach the safety devices. Unused Photo or Photo2 is bridged to Phototest in this diagram; this does not replace the required gate protection.

Alternative: Total Stand-by

Total Stand-by is enabled via Oview; after the set time (1 min by default), it reduces power consumption by switching off the accessories. TX 1 (+), RX 1 (+) and RX 4 COM → COM SBY; TX 2 (−) and RX 2 (−) → GND (1); RX 5 NC → Photo or Photo2. Phototest is not performed with this wiring. Bridge unused Photo/Photo2 to COM SBY. Do not combine the two diagrams.

DPRO924: alternative photocell power supply wiring for Total Stand-by
DPRO924: alternative photocell power supply wiring for Total Stand-by

Safety edge and safety circuit

DPRO924: resistive edge SIG/GND and optical OSE +12 V/SIG/GND
DPRO924: resistive safety edge SIG/GND and optical OSE +12 V/SIG/GND

An active safety edge is required for semi-automatic and automatic operation of the sectional door. Automatic operation also requires photocells. In hold-to-run mode, the operator must have a direct view of the entire door; access to the controls must be restricted according to the installation location.

The 8.2 kΩ resistive safety edge connects between SIG and GND, with no polarity. Optical OSE wiring by designation: brown wire to +12 V, green to SIG, white to GND. If using a different color-coding system, follow the safety edge manufacturer's markings. With this resistive interface, NC contacts are connected in series with the terminating 8.2 kΩ resistor, and NO contacts in parallel with the resistor; the wiring must comply with the safety design. Repeat the learning procedure after making a change. The resistor must not be used to bypass required protection.

Warning beacon and status indicator

For OUT1 the designated device is NICE ELDC with built-in flashing, 24 V, max. 25 W. OUT1 is not an auxiliary GND/24 V pair; do not infer polarity from other connectors. The ELDC power supply pair itself has no specified +/− polarity in its wiring diagram. Connect the antenna to the radio receiver using its connector.

The status indicator on the cover board is separate: LIGHT 1 (−), 2 (+), 24 V DC / 5 W. It goes out when the safety circuit is open, flashes 0.5 s ON / 0.5 s OFF under normal conditions, and follows the OK indicator when there is a fault. The cable may be no longer than 2 m, and the output is not short-circuit protected.

DPRO924: LIGHT 1 (−), 2 (+) on the cover button board
DPRO924: LIGHT 1 (−), 2 (+) on the cover button board

Backup power and service interface

NICE PS224 connects to the designated DPRO924 battery connector only after installation and programming are complete. The number of movements during a power outage is not fixed and depends on the door and battery. Oview connects via NICE IBT4N and allows adjustment of force, sensitivity and deceleration points, as well as diagnostics. Choose accessories for DPRO924, not the old A924.

First start-up of DPRO924 with SUMO

DPRO924: OPEN, STOP and CLOSE buttons on the control unit cover
DPRO924: OPEN, STOP and CLOSE buttons on the control unit cover

On the cover board, the switches enabling the OPEN and CLOSE buttons must be set to ON; STOP is always active. Before learning, the door should be approximately 50 cm above the floor, so the direction can be checked safely. The green OK indicator flashes about once per second; ALT/Photo/Photo2 must match the wiring.

1. Learning the safety devices

At least one safety device must be connected. Learn the devices and positions one after the other, without interruption.

  1. Set A1 to ON; A2/A3/A4 to OFF.
  2. Hold STOP for about 3 s until the OK indicator lights solid red; release it.
  3. When complete, set the switches to OFF and immediately continue with incremental encoder learning.

2. Positions with an incremental encoder

If you do not save a custom partial-opening position, the default position is 1/4 of the travel. It can be changed during learning or via Oview.

  1. Set B2 OFF, B3 OFF; A1 ON, A2/A3/A4 OFF.
  2. Hold STOP for about 3 s until the indicator lights solid red, then release it.
  3. Use OPEN to move the door to the desired open position before the mechanical stop. Confirm by holding STOP for 3 s: one red flash.
  4. Use CLOSE to move the door to the fully closed position. Confirm by holding STOP for 3 s: two red flashes.
  5. To set a custom partial-opening position, use OPEN to move to that point and confirm by holding STOP for 3 s: three red flashes. Otherwise, continue to the next step.
  6. Set A1 to OFF; select A3/A4 according to the operating mode and confirm by pressing P1 for at least 2 s.

If OPEN closes the door, stop, disconnect the mains and battery, swap the motor wires at outputs 1/2, and start the learning procedure again. Do not swap the encoder pair to change direction.

3. Force learning

After learning the positions, perform complete opening and closing cycles without interruption until the unit stops alternating red/green flashes of the OK indicator during movement. An interrupted cycle is not counted. During learning, the unit uses maximum force: the area must be supervised. Repeat learning after changing the speed, deceleration points or sensitivity. Perform safety tests when complete.

The unit initially calculates the RA/RB deceleration points; adjust them via Oview. Repeat force learning after changing the deceleration points.

Setting DPRO924 operating modes

DPRO924: DIP switch group A (1–4) and DIP switch group B (1–3)
DPRO924: DIP switch group A (1–4) and DIP switch group B (1–3)

Switches A and B are on the main board. After changing them, OK may flash alternately red/green and the unit may reject commands: confirm the configuration by pressing P1 for 2 s, and repeat learning of the safety devices if necessary. If these functions are configured via Oview, the corresponding DIP switches must be OFF.

DIP A – operation

SettingMeaning
A1 OFF, A2 OFF, A3 OFF, A4 OFFHold-to-run mode: movement only while a command is held.
A1 ON, A3/A4 OFFLearning the safety devices and positions. For SU2000VV, also set A2 to OFF.
A1 OFF, A2 OFF, A3 OFF, A4 ONIndustrial mode: semi-automatic opening, closing by hold-to-run control.
A1 OFF, A2 OFF, A3 ON, A4 OFFSemi-automatic operation after position learning.
A1 OFF, A2 OFF, A3 ON, A4 ONAutomatic closing with a saved pause time.
A2 ONReverses the absolute encoder; not used with the SU2000VV incremental encoder.

DIP B – sensitivity, speed and motor

SwitchStatus and meaning
B1 – sensitivityOFF = off, ON = on. ON reduces the impact force when an obstacle is detected; after changing it, teach the force limits and perform a measurement.
B2 – speed adjustmentOFF = normal operation; ON = speed setting, OK flashes orange rapidly.
B3 – motor typeOFF for SU2000VV with encoder. ON is for a motor with electromechanical limit switches.

Automatic closing – pause time

  1. After teaching the positions, set A3/A4 to ON and A1/A2 to OFF.
  2. Press and hold P1 for at least 2 seconds.
  3. Send OPEN and wait until the gate is fully open.
  4. From this point, wait for the required pause, then send CLOSE. The time is saved.

To change the pause time, set A4 to OFF and confirm by holding P1 for 2 seconds; this cancels the previous pause time. Then set A4 to ON, confirm by holding P1 for 2 seconds, and repeat the opening, waiting and closing sequence.

Travel and deceleration speed

Opening, slow opening, closing and slow closing are set separately. You can use Oview or the control-board buttons:

  1. Set B2 to ON; OK flashes orange rapidly.
  2. Hold P1 and send OPEN or CLOSE, depending on the direction you want to change.
  3. While holding P1, adjust the current section: OPEN increases the speed by 5% per press; CLOSE decreases it by 5%.. Green OK indicates a normal-speed section; red indicates deceleration.
  4. Release P1; to adjust another movement, start again by holding it down.
  5. Set B2 back to OFF, complete force learning and carry out the tests.

Current monitoring is disabled while P1 is held. Keep the gate under supervision while making this adjustment; do not use it to test the force against an obstacle.

Remote control and antenna

With a supported receiver in extended Mode 2, command 13 electronically unlocks the automation. This removes the electronic lock on the automation; it does not mechanically release the drive. Assign the button as instructed in the manual for the specific receiver.

The radio receiver is inserted into the SM socket with both the mains supply and battery disconnected. Do not confuse the equipment supplied with a standalone drive with a complete kit: choose the receiver and transmitters to match the components actually supplied.

NICE OXIBD supports both unidirectional and bidirectional transmitters; a suitable unidirectional transmitter is the NICE MYGO4. An older installed receiver may use different coding. The same 433.92 MHz frequency alone is not enough.

In standard Mode 1, the receiver outputs are: 1 – step-by-step, 2 – partial opening, 3 – open, 4 – close. Mode 2 lets you assign an individual button to a selected command. For precise pairing and deletion, follow the manual for the specific OXIBD receiver; the control-unit buttons do not erase the receiver's radio memory.

For OXIBD, connect the antenna to the receiver connector as shown in the OXIBD antenna wiring. Connect the coaxial cable's centre conductor to the signal terminal and the shield to the antenna ground. These are not power-supply +/− terminals.

DPRO924 diagnostics

At power-up, two slow green OK flashes indicate a motor with an incremental encoder. One slow red flash confirms a learned 8.2 kΩ edge; two flashes confirm OSE. Rapid green flashing at power-up may indicate that the memory has not been taught.

Red OKCause and check
2 flashesPhotocell: obstruction, optics or relay wiring.
3 flashesForce, sensitivity or a blocked encoder: check for mechanical resistance and inspect the encoder cable.
4 flashesSTOP/ALT or release: secure the motor and check the safety circuit.
5 flashesInternal parameters: press STOP on the cover and wait at least 30 seconds. If the fault persists, contact service; alternatively, reset and teach again.
6 flashesThe permitted number of operations per hour has been exceeded: wait a few minutes for the limit to clear.
7 flashesInternal electrical fault: STOP, disconnect all power sources, and have the board/wiring inspected by a qualified technician.
8 flashesContinuous input command: clear the stuck contact.
9 flashesAutomation electronically locked: use command 13 via a supported receiver to unlock it; radio commands.

Other OK indicator signalsSolution
Red steady + 8 green flashesNo encoder signal. STOP and inspect the separate encoder cable.
Red steady + 10 green flashesTravel time exceeded. STOP; check the mechanism and positions. Adjust the time via Oview.
Red/green alternating while idleDIP settings changed: check the configuration and confirm by holding P1 for at least 2 seconds.
Red/green alternating during movementForce learning in progress; complete the full operating cycles.
Rapid orange flashingB2 is ON; complete the speed setting and set B2 to OFF.

Erasing DPRO924 memory

Resetting erases the settings, positions and learned safety devices. The plug-in radio receiver's memory is separate.

  1. With the gate stationary, set A1/A2/A3/A4 to ON; OK flashes orange rapidly.
  2. Hold STOP for about 3 seconds until OK stays red; release it.
  3. After the reset, OK flashes orange rapidly. Set all DIP A switches back to OFF; OK flashes green.
  4. Set the correct motor type, repeat the safety-device and position learning procedures, learn the force limits, and carry out the tests.

Pre-handover gate checks

  1. With the drive released, check that the gate moves smoothly and is balanced. Manual testing requires a force of no more than 225 N. This is not the motor's torque or the permitted impact force.
  2. After locking the drive, test opening, closing and STOP; the gate must not bind or hit beyond the stored end positions.
  3. Test each pair of photocells at the TX, at the RX and in the centre of the beam, for example using a cylinder 5 cm in diameter and 30 cm long. Check the gate's actual response.
  4. Test the safety edge, safety circuit and emergency release. Measure impact forces with a suitable instrument; repeat the test after changing the force or sensitivity.
  5. Hand over the gate only after successful testing, and provide the identification label, release instructions and maintenance schedule. Pass through only when the gate is fully open and stationary.

Drive and gate maintenance

Disconnect both the mains supply and the battery before each scheduled inspection. Check the bracket, anchors, wedge, shaft, release mechanism, guide components and balance; for chain drives, also check tension, wear and whether lubrication is needed. Use the drive only when the mechanical stops and safety devices are functioning.

For normal residential use, the manufacturer recommends a professional inspection every 6 months. For more frequent use, adjust the interval to suit operating conditions; check and clean the EPM photocells at least every 6 months. Repeat the tests after servicing. A specialist must deal with faults in the springs or load-bearing cables; do not try to compensate by increasing the motor force.

SUMO SU2000VV technical specifications

ParameterValue
Control unitSeparate NICE DPRO924; not included with the SU2000VV.
Motor power supply24 V DC; operating range 15–36 V DC.
Motor current draw / power consumption13 A DC / 500 W. This is not the current drawn from the 230 V mains.
Torque46 Nm.
Speed19.5–42 rpm; setting depends on the control unit and configuration.
Sectional door areaMaximum 15 m².
Duty cycle50%.
Protection rating / temperatureSU2000VV: IP44; −20 to +50 °C.
Shaft / boreShaft Ø 25.4 mm; motor bore Ø 25.5 mm.
Dimensions / weight350 × 270 × 110 mm / 10.5 kg.
Motor insulation thermal classClass B.

SUMO SU2000VV dimensions, shaft bore and bracket range
SUMO SU2000VV dimensions, shaft bore and bracket range

DPRO924 power supply and limits

ParameterValue
Mains supply230 V AC, 50/60 Hz; Class I, grounded.
Maximum mains power consumption500 W.
Accessory output24 V DC −30% / +50%, 200 mA; polarity and terminals.
BackupNICE PS224.
FusesF2 T2 A; F1 automotive fuse 20 A. Use the same type and rating after resolving the cause.
EnclosureIP55 when properly closed; 310 × 210 × 125 mm, approximately 4 kg.

360° view of the drive

 

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Sumo SU2000VV – drive for a sectional garage door or a suspended sliding gate up to 15 m², high speed

Product: NICE Sumo SU2000VV – drive for a sectional garage door or a suspended sliding gate up to 15 m², high speed
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.